Download User Manual - Go Electronic
Transcript
(1) If the low voltage warning alert sounds (refer to the <Remote Controller Power Indicator Status Information>), please replace batteries as soon as possible. (2) Using the incorrect type of battery may prevent a risk of damage. (3) Remove the batteries after use and dispose of them safely. (4) For long term storage, be sure to remove the batteries from the remote controller. 3.3 Remote Controller Power Indicator Status Information Power indicator Sound Remote Controller State None Functioning normally. None Establishing a link between the remote controller and the receiver. B-B-B…… Low voltage (at 3.9V-4.5V), should replace the batteries immediately. BBBB Low voltage (lower than 3.9V). The remote controller will automatically power off. Batteries should be replaced immediately. The remote controller will give a visual indication of an alarm after 15 B-B-B…… minutes of non-operation. The alarm status will disappear once you start operation of the remote controller. The remote controller will blink the LED and sound an alert when the voltage drops below 3.9V and automatically power off after 3 seconds. This process will repeat even if you power cycle the remote controller. If this low voltage warning occurs during flight, the remote controller will automatically power off causing the aircraft to enter Failsafe mode which cannot be interrupted (refer to <Failsafe Function> section for details). It is strongly recommended to replace batteries if the 3.9V-4.5V low voltage warning occurs. 3.4 Antenna Orientation Try to keep the antenna pointing skyward, perpendicular to the ground, in order to achieve the maximum communication range during flight. ©2014 DJI. All Rights Reserved.