The SolarTrak® Controller System
An Incremental Encoder (Open-Loop feedback) utilizes the accumulation of electronic
pulses. These electronic pulses are, in this context, referred to as Counts . This incremental
system is necessarily based on a mechanical or electronic Reference Point (RP) within or at the
end of the range of motion of each axis. An electrical (power interrupting) limit switch
preventing further motion, a magnetic position sensor or a reference pulse from an encoder
generally creates this repeatable mechanical position. The array position is reported as the
Reference Offset (in counts) based on where the zero is established by the RP.
Each morning or evening the controller performs a Reference Check to establish the
Zero’th count by finding the Reference Point. As the day progresses and the Sun position is recomputed, the ideal (computed) position (in counts) is compared to the current actual position. If
the difference between the ideal and actual positions is greater than the specified allowable
‘Deadband’ the controller updates the mechanical position. The elapsed time between updates
varies throughout the day on non-Polar/Declination geometries because update timing is based
on the projection of the sun-speed vector on each axis rather than on a timed update
computation.
Sun Angle Computations:
The following steps compute the Sun’s angle with respect to a specific position on
Earth’s surface and at a specific local solar time:
1. Modify ‘Local Solar Time’ by Time Zone to get GMT.
2. Compute Sun’s Right Ascension and Declination at zero latitude equator) and
longitude (Greenwich, UK).
3. Modify angles for Local Latitude and Longitude.
The National Observatory publishes the equations that produce the Earth’s position with
respect to the Sun. Within the SolarTrak®, the effects of all bodies out to Jupiter are
incorporated into these equations.
The Request Position is then calculated from:
Sun Position (Counts from R.P.) = Sun Angle (radians) * Gear Ratio (counts/radian) +
Reference Offset (Counts from R.P.)
Use of Screwjacks (linear actuators):
When using screwjacks for motion the term ‘Sun Angle’ in the above ‘Sun Position’
equation is replaced by a conversion equation when screwjacks are used. The equation utilizes
the Law of Cosines to express the angle of one side of a triangle as a function of the length of
another side. The Gear Ration is then expressed in Counts-per-Unit Length.
Length =
C3 + C2 * COS[S1 + C1].
See ‘Appendix C’ for diagrams and computations.
Range of Motion Issues: