Troubleshooting Malfunctions with diagnostic message Symptom Cause Solution • Vacuum line between chamber and pressure transducer clogged, disconnected or leaky. • Check, replace if necessary. • Vacuum hose loose, leaky or clogged. • Check, replace if necessary. • Chamber lid gasket not airtight. • Notify the service department. • Pressure transducer is defective. • Notify the service department. • Vacuum pump was not trig• Notify the service department. gered, overload current relay has signalled or vacuum pump is defective. 80 81 • Vacuum pump leaky. • Notify the service department. • Filter in pneumatic line to the sensor is dirty and clogged. • Notify the service department. • Leak in hose connections. • Check, replace if necessary. • Leak in vacuum hose. • Check, replace if necessary. • Leak in pressure transducer and associated measuring line. • Notify the service department. • Sealing diaphragm leaks. • Notify the service department. 8.2 Malfunctions without diagnostic message Symptom Cause Solution Machine does not run. • Machine is switched off. • Switch on the machine. • Power cord is unplugged. • Plug in the power cord. • Chamber lid pressed closed too briefly. • Press chamber lid closed more firmly and for longer. • Chamber lid gasket is dirty. • Clean the chamber lid gasket. • Chamber lid gasket is damaged. • Notify the service department. • Sealing time is set incorrectly. • Correct the sealing time. • Target pressure value incorrectly set. • Correct the target pressure value. Chamber lid does not remain closed despite pump running. Seal seam not airtight pack is slack. 23.03.2010 69