Download Neutron Engineering Inc.
Transcript
Neutron Engineering Inc. 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: EMC Emission EN 55103-1:1996 Test Description Test Method Limit Judgment Conducted Emission EN 55022, 30-1000MHz Class B PASS Radiated Emission EN 55022, 0.15-30MHz Class B PASS ------ PASS ------ N/A ------ PASS Class A PASS ------ PASS ------ N/A NOTE (4) ------ N/A NOTE (5) ------ PASS Signal, control and dc power CISPR G recommendation, port emissions 0.15-30MHz 50Hz-50KHz test at 10cm Magnetic Emissions test method outlined in (Rock mount) Annex A of standard 50Hz-50KHz test at 1m test Magnetic Emissions method outlined in Annex A (Non-Rock mount) of standard Harmonic Current Emission EN 61000-3-2:2006 Voltage Fluctuations & Flicker EN 61000-3-3:1995 +A1: 2001+A2:2005 EN 55014 – required if device produces click interference Required on all AC power ports Clicks on AC (Discontinuous interference) In-Rush Current AC power Antenna port conducted emission NOTE: (1) (2) (3) (4) (5) EN 55013,30-1000MHz Remark NOTE (2) NOTE (3) ” N/A” denotes test is not applicable in this Test Report. In accordance with manual instructions, the product need not be rock mount. The power consumption of EUT is less than 75W and no Limits apply. No clicks. No limit, But manufacturer must state the peak inrush current in the user-documentation. Report No.: NEI-EMC-1-1001C020 Page 7 of 80