Download Installer manual
Transcript
Menu 5.1.1 - hot water settings Menu 5.1.3 - max diff flow line temp. economy max diff compressor Setting range start temp. economy: 15 – 52 °C Setting range: 1 – 25 °C Factory setting start temp. economy: 40 °C Default value: 10 °C Setting range stop temp. economy: 15 – 55 °C max diff addition Factory setting stop temp. economy: 45 °C Setting range: 1 – 24 °C normal Default value: 7 °C Setting range start temp. normal: 15 - 52 °C Factory setting start temp. normal: 45 °C Setting range stop temp. normal: 15 - 55 °C Factory setting stop temp. normal: 50 °C luxury Setting range start temp. lux: 15 – 62 °C Factory setting start temp. lux: 49 °C Setting range stop temp. lux: 15 – 65 °C Factory setting stop temp. lux: 54 °C stop temp. per. increase Setting range: 55 – 70 °C Default values: 55 °C Here you set the maximum permitted difference between the calculated and actual supply temperature during compressor respectively add. heat mode. Max diff. additional heat can never exceed max diff. compressor max diff compressor When the current supply temperature deviates from the set value compared to that calculated, the heat pump is forced to stop irrespective of the degreeminute value. If the current supply temperature exceeds the calculated flow with set value, the degree minute value is set to 0. The compressor in the heat pump stops when there is only a heating demand. max diff addition Here you set the start and stop temperature of the hot water for the different comfort options in menu 2.2 as well as the stop temperature for periodic increase in menu 2.9.1. If "addition” is selected and activated in menu 4.2 and the present supply temp exceeds the calculated with set value, the additional heat is forced to stop. With "high power" activated the hot water is charged with greater power than standard mode and therefore has a greater hot water capacity Menu 5.1.4 - alarm actions Menu 5.1.2 - max flow line temperature The different alternatives are that the heat pump stops producing hot water (default setting) and/or reduces the room temperature. climate system Select how you want the heat pump to alert you that there is an alarm in the display here. Setting range: 20-70 °C Caution Default value: 60 °C If no alarm action is selected, it can result in higher energy consumption in the event of an alarm. Set the maximum supply temperature for the climate system here. If the installation has more than one climate system, individual maximum flow temperatures can be set for each system. Menu 5.1.5 - fan sp. exhaust air Caution normal and speed 1-4 Underfloor heating systems are normally max flow line temperature set between 35 and 45 °C. Setting range: 0 – 100 % Check the max floor temperature with your floor supplier. Set the speed for the five different selectable speeds for the fan here. Caution An incorrectly set ventilation flow can damage the house and may also increase energy consumption. 48 Chapter 8 | Control - Menus NIBE™ F750