Download fusione-hs-3

Transcript
Chapter 3: System Description
BACK PANEL CONNECTOR FEATURES
ITEM ITEM AS MARKED ON UNIT
1
CN1
2
RS232C
3
AC100 ~ 240 VAC
DESCRIPTION
Twist Lock single connector for tool cable connection. Twist
lock type connector can be connected and disconnected by
twisting the outside ring 90 degrees Clockwise and Counter
Clockwise respectively
DB9 connector for fastening result data Output only. Utilized for
connection to a PLC, printer, personal computer, etc.
Primary power-supply input connection.
Input for 100 ~ 240 VAC single-phase 50/60Hz.
A
AUTO SWITCHING
*DO NOT RUN WITHOUT GROUND CONNECTED!
4
TB1
5
Ground Lug
6
RTC Connection
Connection point for discrete inputs and outputs (I/O). When
wired in, the entire connector can be removed by loosening the
upper and lower retaining screws. Refer to chapter 4 for
detailed descriptions of I/O signal.
.
Ground terminal for connection to the Back Panel Cover’s
ground wire
8 pin plastic connector – Real Time Clock Connection
7
SYNC Connection
4 pin plastic connector – Sync. Connector
8
Interface option Mtg.
9
Breaker
10
Fieldbus Interface slot
11
Ethernet Connection
Interface adapter port – Optional Fieldbus or Ethernet board
Electrical Leakage Breaker / Ground Fault detector.
I=on, 0=off
Optional Slot for Fieldbus Interface [Devicenet, Profibus,
CCLink, Ethernet I/P, Profinet, etc]
Optional Slot for Ethernet interface. Used for Ethernet
connection with the AFC programming/monitoring software PC
and/or Ethernet Data Server
WARNING!: DO NOT RUN THIS SYSTEM WITHOUT A PROPER GROUND CONNECTED
TO THE CONTROLLER. THE CONTROLLER IS SUPPLIED WITH A 3-PRONG AC
CABLE INCLUDING A GROUND CONDUCTOR. DO NOT BYPASS THE GROUND
CONNECTION OR SEVERE INJURY OR SHOCK MAY RESULT!
Page 3-6