Download User Manual, MC-ENCODER Absolut Value
Transcript
9 Class 3 / 4 Isochronouser Operation 9.3 Telegram 861 9.3 Telegram 861 In cyclical data exchange, the position values are also transferred isochronously for telegram 861. As for DPV0 (Class 2 functionality), any arbitrary preset value can be activated during the data exchange by setting bit 31. Input data (absolute value encoder on the master): 4 bytes Position value - 32-bit unsigned integer Byte 0 MSB Byte 1 Byte 2 Byte 3 LSB Output data (absolute value encoder on the master): 4 bytes Preset - 32-bit unsigned integer Byte 31 Preset control Byte 30 .........................................................................Byte 0 Preset value < overall resolution Absolute Value Encoder with PROFIBUS-DP User Manual - 08/2014, 6SN1197-0AB10-0BP5 9-63