DC Messages DC271002 Aborting task 000000nn Reason: This message is informational only and might be seen during CA Dispatch shutdown. It is normal and no cause for concern. Action: None DC466003 Process module dates do not match -- Source not displayed Reason: The date in the dialog load module does not match the date stored in the MODULE-067 record in the dictionary for this process. Therefore, the source lines for the abend have not been displayed on the Dialog Abort Information screen. Action: None. DC466014 Abort occurred in dialog <dialog-name> process <process-name> version <version-number> Reason: An error occurred in the <process-name version-number> of dialog <dialog-name>, which caused abnormal termination of the dialog. The messages that follow in the print log give additional diagnostic information. Action: None if prior message DC171017 was issued with RC=14; otherwise, contact Technical Support and provide the text of the message. Chapter 5: DC Messages 171