6.5 Starting Automatic Operation and Overdrive Function Test
To activate automatic operation, proceed as follows:
1. Press the DOWN (70°)  key and
keep it held down until the module
surface is in an inclined position.
2. Detach the manual control unit.
3. Insert the fuse in the SOLTRK (see fig-
ure to right).
CAUTION!
Risk of injury or material damage!
The sonnen_system travel in overdrive mode can cause injuries and material damage.
When one or more sonnen_systems are installed, only start the overdrive
test as described under steps 4 and 5 after all SOLTRK units have been set
up and nobody is working on the sonnen_systems any longer.
4. Operate the overdrive switch S2 (3S1) in
the DC power supply safeguard. (See
figure to the right). The module surface
must travel to 0° position.
5. Operate the overdrive switch in the DC
power supply safeguard again.
6. Set the toggle switch in the SOLTRK to
“AUTO”. The SOLTRK switches to automatic operation. The Sunny WebBox
user interface then displays at spot value
“(Mode)” the value “Auto” for automatic
operation.
7. Screw the cover back onto the SOLTRK. Ensure that the cover fits correctly to
ensure a tight seal.