Download Industrial Computing Solutions Video Intelligent Surveillance NViS

Transcript
NEXCOM International Co., Ltd.
Industrial Computing Solutions
Video Intelligent Surveillance
NViS 3540/3540H/3540P4/3540P8
User Manual
NEXCOM International Co., Ltd.
Published July 2012
www.nexcom.com
Contents
Contents
Preface
Precautions............................................................................................15
Jumper Settings.....................................................................................16
Locations of the Jumpers and Connectors..............................................17
Jumpers.................................................................................................19
Clear CMOS......................................................................................19
Connectors Pin Definitions.....................................................................20
External I/O Interface - Front Panel.....................................................20
USB Ports......................................................................................20
eSATA Ports..................................................................................20
Status Indicators...........................................................................21
LAN1/LAN2 Link/Active LED..........................................................21
ATX Power On/Off Switch.............................................................22
External I/O Interface - Rear Panel......................................................23
Remote Power On/Off Switch.......................................................23
PS/2 Keyboard/Mouse Port............................................................23
9V-30V DC Input..........................................................................24
GPIO Connector...........................................................................24
Serial Interface (COM 1 - COM 4).................................................25
LAN Ports.....................................................................................27
USB Ports......................................................................................28
VGA Port......................................................................................28
DVI-I Port......................................................................................29
Speaker-out Jack...........................................................................29
Mic-in Jack...................................................................................30
Internal Connectors...........................................................................31
ATX Power Output Connector.......................................................31
Copyright ............................................................................................... v
Disclaimer ............................................................................................... v
Acknowledgements ................................................................................ v
Regulatory Compliance Statements ......................................................... v
Declaration of Conformity........................................................................ v
RoHS Compliance................................................................................... vi
Warranty and RMA.................................................................................vii
Safety Information ................................................................................viii
Installation Recommendations................................................................viii
Safety Precautions................................................................................... ix
Technical Support and Assistance............................................................. x
Conventions Used in this Manual............................................................. x
Global Service Contact Information......................................................... xi
Package Contents..................................................................................xiv
Ordering Information..............................................................................xv
Chapter 1: Product Introduction
Overview.................................................................................................1
Hardware Specifications...........................................................................5
Getting to Know NViS 3540 Series...........................................................7
Mechanical Dimensions..........................................................................12
Chapter 2: Jumpers And Connectors
Before You Begin...................................................................................15
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
ii
NViS 3540/3540H/3540P4/3540P8 User Manual
Contents
Reset Connector...........................................................................31
SMBus DATA/CLK Pin Header........................................................32
LVDS Backlight Power Select.........................................................32
LVDS Channel A Connector..........................................................33
LVDS Channel B Connector...........................................................33
LVDS Backlight Connector.............................................................34
SATA Ports....................................................................................35
SATA Power Connectors...............................................................35
SATA DOM Power Connectors......................................................36
USB Port Connector......................................................................36
COM4 RI Pin Header.....................................................................37
GPIO LED Connector.....................................................................37
Line-in Connector.........................................................................38
Internal Power/HDD/LAN Power/LAN Active LED...........................38
Smart Fan Connectors..................................................................39
COM5 Connector.........................................................................39
Parallel Connector........................................................................40
Legends.................................................................................................58
BIOS Setup Utility...................................................................................59
Chapter 5: AMT Settings
Enable Intel® AMT in the AMI BIOS........................................................73
Configure the Intel® ME Setup...............................................................74
Unconfigure AMT/ME............................................................................92
Appendix A: Power Consumption......................... 94
Appendix B: GPI/O Programming Guide............... 96
Appendix C: Watchdog Timer Setting................... 97
Appendix D:Intel Embedded AMT Management
Express KVM...................................... 99
Chapter 3: System Setup
Appendix E: Intel Manageability Command Tool KVM.................................................... 106
Removing the Chassis Cover .................................................................41
Installing a DIMM...................................................................................42
Installing the CPU..................................................................................44
Installing a SATA Hard Drive...................................................................47
Installing a Half Length SATA DOM with SATA HD..................................50
Installing a Full Length SATA DOM.........................................................52
Connecting to the Power Ignition Module (NISKIG120)..........................54
Appendix F: PoE Device Setup................................ 112
Appendix G: Voltage Low Shut-down Setting
(NISKIG120)......................................... 119
Appendix H: DC Input & Output Setting (NISKIG120)......................................... 120
Chapter 4: BIOS Setup
About BIOS Setup..................................................................................57
When to Configure the BIOS..................................................................57
Default Configuration............................................................................58
Entering Setup.......................................................................................58
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
iii
NViS 3540/3540H/3540P4/3540P8 User Manual
Contents
Appendix I: Power On/Off Delay Timer Setting
(NISKIG120)......................................... 121
Appendix J: MCU Programming (NISKIG120)......... 122
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
iv
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Preface
Copyright
Regulatory Compliance Statements
This publication, including all photographs, illustrations and software, is
protected under international copyright laws, with all rights reserved. No
part of this manual may be reproduced, copied, translated or transmitted
in any form or by any means without the prior written consent from
NEXCOM International Co., Ltd.
This section provides the FCC compliance statement for Class B devices
and describes how to keep the system CE compliant.
Declaration of Conformity
FCC
Disclaimer
This equipment has been tested and verified to comply with the limits for
a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area (domestic environment) is likely to cause harmful interference, in which case the user will be required to correct the interference
(take adequate measures) at their own expense.
The information in this document is subject to change without prior notice
and does not represent commitment from NEXCOM International Co., Ltd.
However, users may update their knowledge of any product in use by constantly checking its manual posted on our website: http://www.nexcom.
com. NEXCOM shall not be liable for direct, indirect, special, incidental, or
consequential damages arising out of the use of any product, nor for any
infringements upon the rights of third parties, which may result from such
use. Any implied warranties of merchantability or fitness for any particular
purpose is also disclaimed.
CE
Acknowledgements
The product(s) described in this manual complies with all applicable European Union (CE) directives if it has a CE marking. For computer systems to
remain CE compliant, only CE-compliant parts may be used. Maintaining
CE compliance also requires proper cable and cabling techniques.
NViS 3540/3540H/3540P4/3540P8 is a trademark of NEXCOM International Co., Ltd. All other product names mentioned herein are registered
trademarks of their respective owners.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
v
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
RoHS Compliance
How to recognize NEXCOM RoHS Products?
For existing products where there are non-RoHS and RoHS versions, the suffix “(LF)” will be added to the compliant product name.
NEXCOM RoHS Environmental Policy and Status
Update
All new product models launched after January 2006 will be RoHS compliant. They will use the usual NEXCOM naming convention.
NEXCOM is a global citizen for building the digital infrastructure. We are committed to providing green products
and services, which are compliant with European Union
RoHS (Restriction on Use of Hazardous Substance in Electronic Equipment)
directive 2002/95/EU, to be your trusted green partner and to protect our
environment.
RoHS restricts the use of Lead (Pb) < 0.1% or 1,000ppm, Mercury (Hg)
< 0.1% or 1,000ppm, Cadmium (Cd) < 0.01% or 100ppm, Hexavalent
Chromium (Cr6+) < 0.1% or 1,000ppm, Polybrominated biphenyls (PBB) <
0.1% or 1,000ppm, and Polybrominated diphenyl Ethers (PBDE) < 0.1% or
1,000ppm.
In order to meet the RoHS compliant directives, NEXCOM has established an
engineering and manufacturing task force in to implement the introduction
of green products. The task force will ensure that we follow the standard
NEXCOM development procedure and that all the new RoHS components
and new manufacturing processes maintain the highest industry quality
levels for which NEXCOM are renowned.
The model selection criteria will be based on market demand. Vendors and
suppliers will ensure that all designed components will be RoHS compliant.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
vi
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Warranty and RMA
NEXCOM Warranty Period
?? Any products returned by NEXCOM to other locations besides the customers’ site will bear an extra charge and will be billed to the customer.
NEXCOM manufactures products that are new or equivalent to new in
accordance with industry standard. NEXCOM warrants that products will
be free from defect in material and workmanship for 2 years, beginning
on the date of invoice by NEXCOM. HCP series products (Blade Server)
which are manufactured by NEXCOM are covered by a three year warranty
period.
Repair Service Charges for Out-of-Warranty Products
NEXCOM will charge for out-of-warranty products in two categories, one
is basic diagnostic fee and another is component (product) fee.
System Level
?? Component fee: NEXCOM will only charge for main components such
as SMD chip, BGA chip, etc. Passive components will be repaired for
free, ex: resistor, capacitor.
NEXCOM Return Merchandise Authorization (RMA)
?? Customers shall enclose the “NEXCOM RMA Service Form” with the
returned packages.
?? Items will be replaced with NEXCOM products if the original one cannot
be repaired. Ex: motherboard, power supply, etc.
?? Customers must collect all the information about the problems encountered and note anything abnormal or, print out any on-screen messages,
and describe the problems on the “NEXCOM RMA Service Form” for
the RMA number apply process.
?? Replace with 3rd party products if needed.
?? If RMA goods can not be repaired, NEXCOM will return it to the customer without any charge.
?? Customers can send back the faulty products with or without accessories (manuals, cable, etc.) and any components from the card, such as
CPU and RAM. If the components were suspected as part of the problems, please note clearly which components are included. Otherwise,
NEXCOM is not responsible for the devices/parts.
Board Level
?? Component fee: NEXCOM will only charge for main components, such
as SMD chip, BGA chip, etc. Passive components will be repaired for
free, ex: resistors, capacitors.
?? Customers are responsible for the safe packaging of defective products,
making sure it is durable enough to be resistant against further damage
and deterioration during transportation. In case of damages occurred
during transportation, the repair is treated as “Out of Warranty.”
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
?? If RMA goods can not be repaired, NEXCOM will return it to the customer without any charge.
vii
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Warnings
Installation Recommendations
Read and adhere to all warnings, cautions, and notices in this guide and
the documentation supplied with the chassis, power supply, and accessory
modules. If the instructions for the chassis and power supply are inconsistent with these instructions or the instructions for accessory modules,
contact the supplier to find out how you can ensure that your computer
meets safety and regulatory requirements.
Ensure you have a stable, clean working environment. Dust and dirt can
get into components and cause a malfunction. Use containers to keep
small components separated.
Adequate lighting and proper tools can prevent you from accidentally
damaging the internal components. Most of the procedures that follow
require only a few simple tools, including the following:
Cautions
Electrostatic discharge (ESD) can damage system components. Do the described procedures only at an ESD workstation. If no such station is available, you can provide some ESD protection by wearing an antistatic wrist
strap and attaching it to a metal part of the computer chassis.
•
•
•
•
Safety Information
Using your fingers can disconnect most of the connections. It is recommended that you do not use needlenose pliers to disconnect connections
as these can damage the soft metal or plastic parts of the connectors.
Before installing and using the device, note the following precautions:
▪▪ Read all instructions carefully.
▪▪ Do not place the unit on an unstable surface, cart, or stand.
▪▪ Follow all warnings and cautions in this manual.
▪▪ When replacing parts, ensure that your service technician uses parts
specified by the manufacturer.
▪▪ Avoid using the system near water, in direct sunlight, or near a heating
device.
▪▪ The load of the system unit does not solely rely for support from the
rackmounts located on the sides. Firm support from the bottom is highly
necessary in order to provide balance stability.
▪▪ The computer is provided with a battery-powered real-time clock circuit.
There is a danger of explosion if battery is incorrectly replaced. Replace
only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
A Philips screwdriver
A flat-tipped screwdriver
A grounding strap
An anti-static pad
viii
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Safety Precautions
12. If the equipment is not used for a long time, disconnect it from the
power source to avoid damage by transient overvoltage.
1.
2. Keep this User Manual for later reference.
13. Never pour any liquid into an opening. This may cause fire or electrical shock.
3. Disconnect this equipment from any AC outlet before cleaning. Use a
damp cloth. Do not use liquid or spray detergents for cleaning.
14. Never open the equipment. For safety reasons, the equipment should
be opened only by qualified service personnel.
4. For plug-in equipment, the power outlet socket must be located near
the equipment and must be easily accessible.
15. If one of the following situations arises, get the equipment checked
by service personnel:
5. Keep this equipment away from humidity.
a. The power cord or plug is damaged.
6. Put this equipment on a stable surface during installation. Dropping
it or letting it fall may cause damage.
b. Liquid has penetrated into the equipment.
c. The equipment has been exposed to moisture.
7.
d. The equipment does not work well, or you cannot get it to work
according to the user’s manual.
e. The equipment has been dropped and damaged.
8. The openings on the enclosure are for air convection to protect the
equipment from overheating. DO NOT COVER THE OPENINGS.
f. The equipment has obvious signs of breakage.
9. Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.
17. The unit uses a three-wire ground cable which is equipped with a
third pin to ground the unit and prevent electric shock. Do not defeat
the purpose of this pin. If your outlet does not support this kind of
plug, contact your electrician to replace your obsolete outlet.
Read these safety instructions carefully.
Do not leave this equipment in either an unconditioned environment
or in a above 40oC storage temperature as this may damage the
equipment.
16. Do not place heavy objects on the equipment.
10. Place the power cord in a way so that people will not step on it. Do
not place anything on top of the power cord. Use a power cord that
has been approved for use with the product and that it matches the
voltage and current marked on the product’s electrical range label.
The voltage and current rating of the cord must be greater than the
voltage and current rating marked on the product.
18. CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY
REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE
RECOMMENDED BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS.
11. All cautions and warnings on the equipment should be noted.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
19. The computer is provided with CD drives that comply with the appropriate safety standards including IEC 60825.
ix
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Technical Support and Assistance
Conventions Used in this Manual
1. For the most updated information of NEXCOM products, visit NEXCOM’s website at www.nexcom.com.
Warning: Information about certain situations, which if not
observed, can cause personal injury. This will prevent injury to
yourself when performing a task.
2. For technical issues that require contacting our technical support team
or sales representative, please have the following information ready
before calling:
Caution: Information to avoid damaging components or losing
data.
– Product name and serial number
– Detailed information of the peripheral devices
– Detailed information of the installed software (operating system,
version, application software, etc.)
– A complete description of the problem
– The exact wordings of the error messages
Note: Provides additional information to complete a task easily.
Warning!
1. Handling the unit: carry the unit with both hands and handle it with
care.
2. Maintenance: to keep the unit clean, use only approved cleaning products or clean with a dry cloth.
3. CompactFlash: Turn off the unit’s power before inserting or removing a
CompactFlash storage card.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
x
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Global Service Contact Information
Headquarters
Taiwan
Germany
Leopoldstraße Business Centre, Leopoldstraße 244
80807 Munich, Germany
Tel: +49-89-208039-278
Fax: +49-89-208039-279
http://www.nexcom.eu
15F, No. 920, Chung-Cheng Rd., ZhongHe District,
New Taipei City, 23586, Taiwan, R.O.C.
Tel: +886-2-8226-7786
Fax: +886-2-8226-7782
http://www.nexcom.com.tw
Italy
USA
Via Gaudenzio Ferrari 29,
21047 Saronno (VA), Italia
Tel: +39 02 9628 0333
Fax: +39 02 9619 8846
http://www.nexcom.eu
3758 Spinnaker Court,
Fremont, CA 94538, USA
Tel: +1-510-656-2248
Fax: +1-510-656-2158
http://www.nexcom.com
United Kingdom
10 Vincent Avenue, Crownhill Business Centre,
Milton Keynes, Buckinghamshire
MK8 0AB, United Kingdom
Tel: +44-1908-267121
Fax: +44-1908-262042
http://www.nexcom.eu
France
NEXCOM France
La Grande Arche-Paroi Nord,
92044 Paris La Défense, France
Tel: +33 (0)1 40 90 33 35
Fax: +33 (0)1 40 90 31 01
http://www.nexcom.eu
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
xi
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
China
NEXCOM China
China-Wuhan Office
2F, Block 4, Venus Plaza, Building 21,
ZhongGuanCun Software Park, No. 8,
Dongbeiwang West Road, Haidian District,
Beijing, 100193, China
Tel: +86-10-8282-5880
Fax: +86-10-8282-5955
http://www.nexcom.cn
1-C1804/1805, Mingze Liwan,
No. 519 South Luoshi Rd., Hongshan District,
Wuhan, 430070, China
Tel: +86-27-8722-7400
Fax: +86-27-8722-7400
http://www.nexcom.cn
China-Shanghai Office
Western Room 708, Block 210,
Tairan Industry & Trading Place, Futian Area,
Shenzhen, 518040, China
TEL: +86-755-833 7203
FAX: +86-755-833 7213
http://www.nexcom.cn
China-Shenzhen Office
Room 1505, Greenland He Chuang Building,
No. 450 Caoyang Rd.,
Shanghai, 200062, China
Tel: +86-21-6150-8008
Fax: +86-21-3251-6358
http://www.nexcom.cn
China-Chengdu Office
China-Nanjing Office
9F, Shuxiangxie, Xuefu Garden,
No.12 Section 1, South Yihuan Rd.,
Chengdu, 610061,China
Tel: +86-28-8523-0186
Fax: +86-28-8523-0186
http://www.nexcom.cn
Hall C, Block 17, Tian Xing Cui Lang Building,
No. 49 Yunnan North Rd.,
Nanjing, 210018, China
Tel: +86-25-8315-3486
Fax: +86-25-8315-3489
http://www.nexcom.cn
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
xii
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Japan
9F, Tamachi Hara Bldg.,
4-11-5, Shiba Minato-ku,
Tokyo, 108-0014 Japan
Tel: +81-3-5419-7830
Fax: +81-3-5419-7832
http://www.nexcom-jp.com
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
xiii
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Package Contents
Before continuing, verify that the NViS 3540/3540H/3540P4/3540P8 package that you received is complete. Your package should have all the items listed in
the following table.
Item
Part Number
1
60233POW33X00
DC Power Cable
1
2
6023344361X00
DB44 to 4x DB9 COM port cable
1
3
6029900037X00
DOW CORNING 340 Silcone Heat Sink Compound (3g)
1
4
4NCPM00203X00
2 Pin Phoenix Contact: MC 1.5/2-ST-3.81(1803578), 3.81mm pitch
1
5
50311F0110X00
Flat Head Screw for HDD F3x5 ISO+NYLOK NIGP
4
6
602DCD0269X00
NISB3500 CD DRIVER VER:1.0
1
7
7800000014X00
DVI-I TO VGA Adapter
1
8
5060600087X00
Mylar for PCI bracket
1
9
60177A0205X00
NISB3500 Quick Reference Guide VER:A
1
10
50311P0001X00
Plastic Screw for PCI card use
1
11
60233MK202X00
PS/2 Y Cable for Keyboard / Mouse, L:150mm
1
12
50322P0001X00
Plastic Nut for PCI card use
1
1. D-Type integrated cable Video & Audio input x4 TV-out x2
2. Surveillance system user manual
3. Surveillance CD/driver
1
13
Description
Qty
Note: For NViS 3540H only.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
xiv
NViS 3540/3540H/3540P4/3540P8 User Manual
Preface
Ordering Information
The following provides ordering information for NViS 3540/3540H/3540P4/3540P8.
• Barebone
NViS 3540 (P/N: 10C0035400X0) RoHS Compliant
- Mobile Surveillance with Intel® Core™ i7/ i5 System
- 1 PCIe x1 expansion slot
- 19V, 120W AC/DC power adapter w/o power cord (P/N: 7410120002X00)
NViS 3540H (P/N: 10C03540H00X0) RoHS Compliant
- 4-channel Mobile Surveillance with Intel® Core™ i7/ i5 System
- 19V, 120W AC/DC power adapter w/o power cord
(P/N: 7410120002X00)
NViS 3540P4 (P/N: 10C0354P0X0) RoHS Compliant
-Intel® Core™ i7/i5 system
- 4 PoE ports
- 2180 24V, 180W power adapter w/o power core
(P/N:7400180002x00)
NViS 3540P8 (P/N:10C03540P01X0) RoHS Compliant
- Mobile NVR Surveillance with Intel® Core™ i7/ i5 System
- 8 PoE ports
- 24V, 180W AC/DC power adapter w/o power cord
(P/N:7400180002X00)
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
xv
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Chapter 1: Product Introduction
Overview
NViS 3540
Front
Rear
Key Features
• Intel® Core™ i7/i5 socket processor
• Mobile Intel® QM57 PCH
• Dual Intel® Gigabit Ethernet ports
• Dual VGA or VGA/DVI Independent Display
• 3x RS232 and 1x RS232/422/485 with Auto Flow
Control
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
• Fanless
• 1 PCI expansion slot
• Onboard DC to DC power design to support
9V to 30V DC power input
1
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
NViS 3540H
Front
Rear
Key Features
• Intel® Core™ i7/i5 socket processor
• Mobile Intel® QM57 PCH
• Dual Intel® Gigabit Ethernet ports
• Dual VGA or VGA/DVI Independent Display
• 3x RS232 and 1x RS232/422/485 with Auto Flow
Control
• Fanless
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
• Onboard DC to DC power design to support 9V to
30V DC power input
• 4-Channel Full D1 (720x480 NTSC, 720x576 PAL)
Display/Recording
• Total 120 FPS (NTSC), 1000 FPS (PAL)
• NViS Hybrid Software
2
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
NViS 3540P4
Front
Rear
Key Features
• Intel® Core™ i7/i5 socket processor
• Mobile Intel® QM57 PCH
• Dual Intel® Gigabit Ethernet ports
• Dual VGA or VGA/DVI Independent Display
• 3x RS232 and 1x RS232/422/485 with Auto Flow
Control
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
• Smart fan
• 4 ports PoE switch
• Onboard DC to DC power design to support 9V to
30V DC power input
3
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
NViS 3540P8
Front
Rear
Key Features
• Intel® Core™ i7/i5 socket processor
• Mobile Intel® QM57 PCH
• Dual Intel® Gigabit Ethernet ports
• Dual VGA or VGA/DVI Independent Display
• 3x RS232 and 1x RS232/422/485 with Auto Flow
Control
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
• Smart fan
• 8 ports PoE switch
• Onboard DC to DC power design to support 9V to
30V DC power input
4
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Hardware Specifications
I/O Interface - Rear
• 2-pin Remote Power on/off switch
• 9 ~ 30V DC input
• 1 x PS/2 for Keyboard/Mouse
• 1 x DB15 male connector for GPIO (4x digital-input and 4x digital-output)
• 1 x DB44 Serial Port for 4x RS232
(COM2: RS232/422/485 with Auto Flow Control)
• 2 x Gbe LAN ports
• 4 x USB 2.0 ports
• 1 x DB15 VGA port
• 1 x DVI-D Port
• 1 x Speaker-out
• 1 x Mic-in
Main Board
• NISB 3500
• Onboard Mobile Intel® QM57 Platform Controller Hub
• Supports Intel® Core™ i7-620M PGA Processor (2.66GHz, 4M Cache)
• Supports Intel® Core™ i5-520M PGA Processor (2.4GHz, 3M Cache)
• Supports Intel® P4500 PGA Processor (1.86GHz, 2M Cache)
Main Memory
• 2x 240-pin memory DIMM, up to 4GB DDR3 800/1066MHz SDRAM,
unbuffered and non-ECC
Note: The actual memory size is dynamic. It is based on the OS I/O resource allocation.
Device
• 2x 2.5” HDD drive bays (NViS 3540P8 only)
• 1x 2.5” HDD drive bay and 1x 2.5” hot swappable drive bay (NViS
3540/3540H/3540P4 only)
I/O Interface - Front
• ATX power on/off switch
• HDD Access / Power status LEDs
• 2x USB 2.0 ports
• 2x eSATA ports
• 1x 2.5” HDD with Hot Swap (NViS 3540/3540H/3540P4 only)
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
Expansion
• 1 PCI expansion slot (NViS 3540 only)
• 1x 4-channel Hybrid capture card (NViS 3540H only)
• 4 ports PoE switch (NViS 3540P4 only)
• 8 ports PoE switch (NViS 3540P8 only)
5
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Power Requirements
• ATX power mode
• Onboard DC to DC power support from 9V to 30V DC
• Optional power adapter
Dimensions
• 195mm (W) x 268mm (D) x 80mm (H) - NViS 3540/3540H only
• 235mm (W) x 268 mm (D) x 80mm (H) - NViS 3540P4/3540P8 only
Construction
• Aluminum chassis
- Fanless (NViS 3540/3540H only)
- With Smart Fan (NViS 3540P4/3540P8 only)
Environment
• Operating temperature:
Ambient with airflow: -5°C to 55°C
(According to IEC60068-2-1, IEC60068-2-2, IEC60068-2-14)
• Storage temperature: -20°C to 80°C
• Relative humidity: 10% to 93% (Non-Condensing)
Certifications
• CE approval
• FCC Class B
• e13 Mark
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
6
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Getting to Know NViS 3540 Series
Front Panel
LAN LEDs
Power LED
Power on/off
switch
USB
eSATA
HDD LED
Hot swappable
2.5” HDD bay
USB
Used to connect USB 2.0/1.1 devices.
LAN LEDs
Indicate the status of the LAN ports.
eSATA
Used to connect eSATA devices.
Power On/Off Switch
Press to power-on or power-off the system.
Hot Swappable 2.5” HDD Bay (NViS 3540/3540H/3540P4 only)
Used to install a hot swappable 2.5” HDD drive.
Power LED
Indicates the power status of the system.
HDD LED
Indicates the status of the hard drive.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
7
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Rear Panel of NViS 3540
LAN
Used to connect the system to a local area network.
PS/2 KB/Mouse GPIO LAN/USB VGA
USB
Used to connect USB 2.0/1.1 devices.
Output for
remote power
on/off swtich
Speaker-out
Mic-in
9V-30V
DC Input
Power
Ignition
VGA
Used to connect an analog VGA monitor.
DVI
Used to connect a digital LCD panel.
Expansion
card slots
COM1-COM4
Speaker-out
Used to connect a headphone or a speaker.
DVI
Mic-in
Used to connect an external microphone.
Output for Remote Power On/Off Switch
Used to connect a remote to power on/off the system.
Expansion Slots
One PCI expansion slot.
PS/2 Keyboard/Mouse
Used to connect a PS/2 keyboard and PS/2 mouse via a cable.
Power Ignition
Used to connect to power ignition module (NISKIG120).
9V-30V DC Input
Used to plug a DC power cord.
GPIO
The GPIO connector supports 4 digital input and 4 digital output.
COM1 to COM4
The DB44 port supports 3 RS232 and 1 RS232/422/485 compatible serial
devices.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
8
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Rear Panel of NViS 3540H
LAN
Used to connect the system to a local area network.
PS/2 KB/Mouse GPIO LAN/USB VGA
DVI
Output for
remote power
on/off swtich
VGA
Used to connect an analog VGA monitor.
Speaker-out
Mic-in
9V-30V
DC Input
Power
Ignition
USB
Used to connect USB 2.0/1.1 devices.
DVI
Used to connect a digital LCD panel.
Expansion
card slot
COM1-COM4
Speaker-out
Used to connect a headphone or a speaker.
Capture card connector
for cameras
Mic-in
Used to connect an external microphone.
Output for Remote Power On/Off Switch
Used to connect a remote to power on/off the system.
Capture Card
Supports 4-channel full-D1 SD feature.
PS/2 Keyboard/Mouse
Used to connect a PS/2 keyboard and PS/2 mouse via a cable.
Power Ignition
Used to connect to power ignition module (NISKIG120).
9V-30V DC Input
Used to plug a DC power cord.
GPIO
The GPIO connector supports 4 digital input and 4 digital output.
COM1 to COM4
The DB44 port supports 3 RS232 and 1 RS232/422/485 compatible serial
devices.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
9
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Rear Panel of NViS 3540P4
LAN
Used to connect the system to a local area network.
PS/2 KB/Mouse GPIO LAN/USB VGA
USB
Used to connect USB 2.0/1.1 devices.
Output for
remote power
on/off swtich
Speaker-out
Mic-in
9V-30V
DC Input
Power
Ignition
VGA
Used to connect an analog VGA monitor.
DVI
Used to connect a digital LCD panel.
Expansion
card slot
COM1-COM4
Speaker-out
Used to connect a headphone or a speaker.
DVI
4 ports PoE
switch
Mic-in
Used to connect an external microphone.
Output for Remote Power On/Off Switch
Used to connect a remote to power on/off the system.
4 Ports PoE Switch
Allows connecting 4 IP security cameras.
PS/2 Keyboard/Mouse
Used to connect a PS/2 keyboard and PS/2 mouse via a cable.
Power Ignition
Used to connect to power ignition module (NISKIG120).
9V-30V DC Input
Used to plug a DC power cord.
GPIO
The GPIO connector supports 4 digital input and 4 digital output.
COM1 to COM4
The DB44 port supports 3 RS232 and 1 RS232/422/485 compatible serial
devices.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
10
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Rear Panel of NViS 3540P8
LAN
Used to connect the system to a local area network.
PS/2 KB/Mouse GPIO LAN/USB VGA
DVI
Output for
remote power
on/off swtich
VGA
Used to connect an analog VGA monitor.
Speaker-out
Mic-in
9V-30V
DC Input
Power
Ignition
USB
Used to connect USB 2.0/1.1 devices.
DVI
Used to connect a digital LCD panel.
8 ports PoE
switch
Speaker-out
Used to connect a headphone or a speaker.
COM1-COM4
Output for Remote Power On/Off Switch
Used to connect a remote to power on/off the system.
Mic-in
Used to connect an external microphone.
PS/2 Keyboard/Mouse
Used to connect a PS/2 keyboard and PS/2 mouse via a cable.
8 Ports PoE Switch
Allows connecting 8 IP security cameras.
9V-30V DC Input
Used to plug a DC power cord.
Power Ignition
Used to connect to power ignition module (NISKIG120).
GPIO
The GPIO connector supports 4 digital input and 4 digital output.
COM1 to COM4
The DB44 port supports 3 RS232 and 1 RS232/422/485 compatible serial
devices.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
11
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
Mechanical Dimensions
184,00
224,00
264,00
268,00
NViS 3540/3540H
101,00
107,00
195,00
207,00
219,00
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
12
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
NViS 3540P4
101.00
107.00
184.00
224.00
268.00
255.00
243.00
235.00
255.00
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
13
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 1: Product Introduction
NViS 3540P8
101.00
107.00
184.00
224.00
268.00
255.00
243.00
235.00
255.00
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
14
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Chapter 2: Jumpers and Connectors
This chapter describes how to set the jumpers on the motherboard. Note
that the following procedures are generic for all NViS 3540 series.
tronic components. Humid environment tend to have less static electricity than dry environments. A grounding strap is warranted whenever
danger of static electricity exists.
Before You Begin
Precautions
• Ensure you have a stable, clean working environment. Dust and dirt can
Computer components and electronic circuit boards can be damaged by
discharges of static electricity. Working on the computers that are still connected to a power supply can be extremely dangerous.
get into components and cause a malfunction. Use containers to keep
small components separated.
• Adequate lighting and proper tools can prevent you from accidentally
Follow the guidelines below to avoid damage to your computer or yourself:
damaging the internal components. Most of the procedures that follow
require only a few simple tools, including the following:
• Always disconnect the unit from the power outlet whenever you are
• A Philips screwdriver
working inside the case.
• A flat-tipped screwdriver
• If possible, wear a grounded wrist strap when you are working inside
• A set of jewelers Screwdrivers
the computer case. Alternatively, discharge any static electricity by
touching the bare metal chassis of the unit case, or the bare metal body
of any other grounded appliance.
• A grounding strap
• An anti-static pad
• Using your fingers can disconnect most of the connections. It is recom-
• Hold electronic circuit boards by the edges only. Do not touch the com����
mended that you do not use needle-nosed pliers to disconnect connections as these can damage the soft metal or plastic parts of the connectors.
ponents on the board unless it is necessary to do so. Don’t flex or stress
the circuit board.
• Leave all components inside the static-proof packaging that they
• Before working on internal components, make sure that the power
shipped with until they are ready for installation.
is off. Ground yourself before touching any internal components, by
touching a metal object. Static electricity can damage many of the elec-
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
• Use correct screws and do not over tighten screws.
15
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Jumper Settings
A jumper is the simplest kind of electric switch. It consists of two metal
pins and a cap. When setting the jumpers, ensure that the jumper caps are
placed on the correct pins. When the jumper cap is placed on both pins,
the jumper is short. If you remove the jumper cap, or place the jumper
cap on just one pin, the jumper is open.
Refer to the illustrations below for examples of what the 2-pin and 3-pin
jumpers look like when they are short (on) and open (off).
Two-Pin Jumpers: Open (Left) and Short (Right)
Three-Pin Jumpers: Pins 1 and 2 Are Short
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
16
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Locations of the Jumpers and Connectors
NISB 3500
The figure below is the top view of the NISB 3500 main board which is the main board used in the NViS 3540 Series system. It shows the locations of the
jumpers and connectors.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
17
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
The figure below is the bottom view of the NISB 3500 main board.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
18
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Jumpers
Clear CMOS
Connector size: 1x3 3-pin header, 2.54 mm pitch
Connector location: JP4
3
1
Pin
Settings
1-2 On
*Normal
2-3 On
CMOS Clear
1-2 On: default
Pin
Definition
1
RTCRST#_PU
2
RTCRST#
3
CLR_CMOS
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
19
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Connector Pin Definitions
External I/O Interface - Front Panel
USB Ports
eSATA Ports
Connector type: Dual USB port
Connector location: CN10
Connector type: eSATA port
Connector location: CON2A and CON2B
Pin
1
Pin
Definition
Definition
GND
Pin
Definition
5
SATA_RXN4
Pin
Definition
2
SATA_TXP4
6
SATA_RXP4
7
USB1+
3
SATA_TXN4
7
GND
USB0-
8
GND
4
GND
USB0+
22
GND
4
GND
23
GND
5
+5V
26
GND
6
USB1-
27
GND
1
+5V
2
3
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
20
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Status Indicators
LAN1/LAN2 Link/Active LED
Connector location: LED1 and LED2
PWR
LINK1
LINK2
ACT1
ACT2
HDD
Status
LED Color
PWR
Green
Pin
Definition
HDD
Yellow
C1
LAN2_LINK_N
C2
LAN2_ACT_N
A1
LAN2_LINK_P
A2
LAN2_ACT_P
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
21
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
ATX Power On/Off Switch
Connector location: SW1
Pin
Definition
On
Blue light
Off
Red light
Pin
Definition
Pin
Definition
1
GND
2
PBT_PU
3
PBT_PU
4
GND
A1
PWRLED_N
C1
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
PWRLED_P
22
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
External I/O Interface - Rear Panel
Remote Power On/Off Switch
PS/2 Keyboard/Mouse Port
Connector type: 2-pin switch
Connector location: J3
Connector type: PS/2, Mini-DIN-6, JST-2.0mm-M-180
Connector location: J5
1
6
4
2
Pin
GND
2
PBT_PU
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
6
1
2 1
Definition
1
5
3
Pin
23
Definition
Pin
Definition
1
5VSB
2
KDAT
3
KCLK
4
MDAT
5
MCLK
6
GND
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
9V-30V DC Input
GPIO Connector
(4 digital input and 4 digital output)
Connector type: POWER-F-90
Connector location: CN1
Connector type:DB-15 port, 2x5 10-pin header, 2.0 mm-M-180
Connector location: JP2
2
4
1
3
1
2
9
10
Pin
Definition
Pin
1
VIN
2
VIN
Pin
3
GND
4
GND
1
5
GND
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
5
1
15
11
Definition
24
Definition
VCC5
Pin
2
Definition
GND
3
SIO_GPO24
4
SIO_GPI20
5
SIO_GPO25
6
SIO_GPI21
7
SIO_GPO26
8
SIO_GPI22
9
SIO_GPO27
10
SIO_GPI23
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Serial Interface (COM 1 - COM 4)
Pin
Connector type: 44-pin D-Sub, 2x22 (12.55mm x 53.04mm)
Connector location: CN4
30
1
15
44
44-pin D-Sub
1
16
31
The 44-pin D-Sub connector is used to connect 4 external serial devices.
Use the COM ports on the provided “DB44 to 4x DB9 COM port cable”
(included in the package) to connect the devices.
6
1
5
9
COM port
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
25
Definition
CN10_1
Pin
2
Definition
CN10_2
3
CN10_3
4
CN10_4
5
GND
6
CN10_6
7
CN10_7
8
CN10_8
9
CN10_9
10
GND
11
CN10_11
12
CN10_12
13
CN10_13
14
CN10_14
15
GND
16
CN10_16
17
CN10_17
18
CN10_18
19
CN10_19
20
GND
21
CN10_21
22
CN10_22
23
CN10_23
24
CN10_24
25
GND
26
CN10_26
27
CN10_27
28
CN10_28
29
CN10_29
30
GND
31
CN10_31
32
CN10_32
33
CN10_33
34
CN10_34
35
GND
36
CN10_36
37
CN10_37
38
CN10_38
39
SP4_RI_TI
40
GND
41
NC
42
NC
43
NC
44
NC
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
COM1 (RS232) labelled “A“ on DB9 Cable Connector
COM1 (RS232) labelled “D“ on DB9 Cable Connector
DB44 Pin #
DB9 Pin #
Def.
DB44 Pin #
DB9 Pin #
Def.
DB44 Pin #
DB9 Pin #
Def.
DB44 Pin #
DB9 Pin #
Def.
1
1
DCD1
2
2
RXD1
31
1
DCD1
32
2
RXD1
3
3
TXD1
4
4
DTR1
33
3
TXD1
34
4
DTR1
5
5
GND
6
6
DSR1
35
5
GND
36
6
DSR1
7
7
RTS1
8
8
CTS1
37
7
RTS1
38
8
CTS1
9
9
RI1
10
39
9
RI1
40
GND
COM2 (RS232) labelled “B“ on DB9 Cable Connector
DB44 Pin #
DB9 Pin #
Def.
DB44 Pin #
DB9 Pin #
Def.
11
1
DCD2
12
2
RXD2
13
3
TXD2
14
4
DTR2
15
5
GND
16
6
DSR2
17
7
RTS2
18
8
CTS2
19
9
RI2
20
COM2 (RS422) labelled “B“ on DB9 Cable Connector
GND
COM3 (RS232) labelled “C“ on DB9 Cable Connector
DB44 Pin #
DB9 Pin #
Def.
DB44 Pin #
DB9 Pin #
Def.
21
1
DCD3
22
2
RXD3
23
3
TXD3
24
4
DTR3
25
5
GND
26
6
DSR3
27
7
RTS3
28
8
CTS3
29
9
RI3
30
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
GND
Note: Pin 39 is defined as an external power source, which can be selected for 5V
or 12V using JP10.
DB44 Pin #
DB9 Pin #
Def.
DB44 Pin #
DB9 Pin #
Def.
11
1
TXD-
12
2
TXD+
13
3
RXD+
14
4
RXD-
15
5
GND
16
6
RTS-
17
7
RTS#
18
8
CTS+
19
9
CTS-
20
GND
GND
26
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
LAN Ports
COM2 (RS485) labelled “B“ on DB9 Cable Connector
DB44 Pin #
DB9 Pin #
11
1
Def.
DB44 Pin #
DB9 Pin #
TXD-
12
2
RXD-
Connector type: RJ45 port with LEDs
Connector location: CN3B and CN6B
Def.
TXD+
RXD+
13
3
Reserved
14
4
Reserved
15
5
Reserved
16
6
Reserved
17
7
Reserved
18
8
Reserved
19
9
Reserved
20
Act
Link
Reserved
Act
Status
Link
Status
Orange
Blinking
Data Activity
Green
Always Lighted
Linked
Off
No Acitivity
Off
No Link
Pin
09
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
27
Definition
LAN1_M0P
Pin
10
Definition
LAN1_M0N
11
LAN1_M1P
12
LAN1_M2P
13
LAN1_M2N
14
LAN1_M1N
15
LAN1_M3P
16
LAN1_M3N
17
LAN1_LED1P
18
LAN1_LED_ACT#
19
LAN1_LED2P
20
LAN1_LINK#
21
GND
24
GND
25
GND
28
GND
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
USB Ports
VGA Port
Connector type: Dual USB port
Connector location: CN3A and CN6A
Connector type: DB-15 port, 15-pin D-Sub
Connector location: CN9B
Pin
Definition
Pin
Definition
1
+5V
7
USB1+
2
USB0-
8
GND
3
USB0+
22
GND
4
GND
23
GND
5
+5V
26
GND
6
USB1-
27
GND
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
5
1
15
11
Pin
25
28
Definition
RED_VGA
Pin
Definition
26
GREEN_VGA
27
BLUE_VGA
28
GND
29
GND
30
GND
31
GND
32
GND
33
VGA_+5V
34
GND
35
GND
36
DATA_V
37
HS_VGA
38
VS_VGA
39
CLK_V
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
DVI-I Port
Speaker-out Jack
Connector type: 30-pin D-Sub, 2.0mm-M-180
Connector location: CN9A
Connector type: 5-pin jack
Connector location: CN11B
1
8
17
24
2
34
1
33
Pin
Pin
Function
Pin
Function
Definition
1
GND
SPK_Out_R
01
HDMI_DATA2_N
2
HDMI_DATA2_P
2
03
DVI_GND
4
NC
3
NC
NC
SPK_Out_L
05
NC
6
HDMI_CTL_CLK
4
07
HDMI_CTL_SDA
8
DC_VSYNC_VGA
5
09
HDMI_DATA1_N
10
HDMI_DATA1_P
11
DVI_GND
12
NC
13
NC
14
HDMIC_PWR_S
15
DVI_GND
16
HDMIC_HPDET
17
HDMI_DATA0_N
18
HDMI_DATA0_P
19
DVI_GND
20
DC_DATA_VGA
21
DC_CLK_VGA
22
NC
23
HDMI_LKP
24
HDMI_LKN
C1
DC_RED_VGA
C2
DC_GREEN_VGA
C3
DC_BLUE_VGA
C4
DC_HSYNC_VGA
DVI_GND
C5B
DVI_GND
C5A
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
29
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Mic-in Jack
Connector size: 5-pin jack, 25.9x12.6x17.0mm
Connector location: CN11A
Pin
Definition
1
AU_GND
2
MIC_OUT-L
3
AU_GND
4
MIC_JD1
5
MIC_OUT-R
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
30
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Internal Connectors
ATX Power Output Connector
Reset Connector
Connector type:2x2 Aux power connector
Connector location: CON1
Connector type: 1x2 2-pin header, JST 2.5mm-M-90
Connector location: J2
1
3
2
4
1
2
Pin
Definition
1
GND
2
GND
3
VIN
4
VIN
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
31
Pin
Definition
1
RESET#
2
GND
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
SMBus DATA/CLK Pin Header
LVDS Backlight Power Select
Connector type:1x3 3-pin header 2.54mm-M-180
Connector location: J8
Connector type:1x3 3-pin header 2.54mm-M-180
Connector location: JP3
1
1
3
3
Pin
Definition
Pin
Definition
1
SMB_CLK
1
VCC5
2
SMB_DATA
2
PANEL1_VDD
3
GND
3
VCC3
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
32
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
LVDS Channel A Connector
LVDS Channel B Connector
Connector type: LCD-1.25mm-M-180
Connector location: CN7
Connector type: LCD-1.25mm-M-180
Connector location: CN8
MH1
MH1
1
19
1
19
2
20
2
20
MH2
MH2
Pin
Definition
Pin
1
L_DDC_CLK
2
L_DDC_DATA
Definition
3
VDD
4
LA_DATAP0
3
VDD
4
LB_DATAP0
5
LA_DATAP3
6
LA_DATAN0
5
LB_DATAP3
6
LB_DATAN0
7
LA_DATAN3
8
VDD
7
LB_DATAN3
8
VDD
9
GND_LVDS
10
LA_DATAP1
9
GND_LVDS
10
LB_DATAP1
11
LA_CLKP
12
LA_DATAN1
11
LB_CLKP
12
LB_DATAN1
13
LA_CLKN
14
GND_LVDS
13
LB_CLKN
14
GND_LVDS
15
GND_LVDS
16
PANEL1_BACKLIGHT
15
GND_LVDS
16
PANEL1_BACKLIGHT
17
LA_DATAP2
18
PANEL1_BACKLIGHT
17
LB_DATAP2
18
PANEL1_BACKLIGHT
19
LA_DATAN2
20
GND_LVDS
19
LB_DATAN2
20
GND_LVDS
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
33
Pin
Definition
Pin
1
L_DDC_CLK
2
Definition
L_DDC_DATA
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
LVDS Backlight Connector
Connector type: 1x7 7-pin header JST-2.5mm-M-180
Connector location: J13
7
1
Pin
Definition
1
VCC5
2
PANEL1_BACKLIGHT
3
PANEL1_BACKLIGHT
4
L_BKLTCTL_R
5
GND
6
GND
7
L_BKLTEN
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
34
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
SATA Ports
SATA Power Connectors
Connector type: Standard Serial ATAII 7P (1.27mm, SATA-M-180)
Connector location: CN12 and CN13
Connector type: 4-pin Wafer, 2.54mm-M-180
Connector location: CN14 and CN15
1
7
1
4
Pin
Definition
1
GND
2
SATA_TXP1
1
+12V
3
SATA_TXN1
2
GND
4
GND
3
GND
5
SATA_RXN1
4
VCC5
6
SATA_RXP1
7
GND
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
Pin
35
Definition
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
SATA DOM Power Connectors
USB Port Connector
Connector type:1x2 2-pin JST wafer, 2.54mm pitch
Connector location: J16 and J17
Connector type:6-pin boxed header, JST-2.0mm-M-180
Connector location: J12
1
1
2
Pin
Definition
1
+12V
2
GND
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
6
Pin
36
Definition
1
+5V
2
GND
3
USB10+
4
USB11-
5
USB11+
6
USB2_GND
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
COM4 RI Pin Header
GPIO LED Connector
Connector type:1x5 5-pin header 2.0mm -M-180
Connector location: J9
Connector type:2x2 4-pin 2.0mm -M-180
Connector location: JP1
1
3
1
2
4
Pin
5
Definition
1
GPO_LED0
2
GND
VCC5
3
GPO_LED1
2
SP4_RI_T
4
GND
3
+12V
4
SP4_RI_T
5
SP4_R
Pin
1
Definition
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
37
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Line-in Connector
Internal Power/HDD/LAN Power/LAN Active LED
Connector type:1x4 4-pin header 2.5mm-M-180
Connector location: J15
Connector type:2x7 14-pin header 2.54mm-M-180
Connector location: J4
4
1
2
14
1
13
Pin
Definition
1
LINE1-LP
2
GND
3
LINE1-JD
1
LED_PWRN
2
LED_PWRP
4
LINE1-RP
3
HD_LEDN
4
LED_HDDP
5
LAN1_LINK#
6
LAN1_LINKP
7
LAN1_LED_ACT#
8
LAN1_ACTP
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
Pin
38
Description
Pin
Description
9
LAN2_LINK#
10
LAN2_LINKP
11
LAN2_LED_ACT#
12
LAN2_ACTP
13
NC
14
NC
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Smart Fan Connectors
COM5 Connector
Connector size: 4-pin Wafer, 2.54mm-M-180
Connector location: J1 and J14
Connector type:2x5 10-pin boxed header, 2.0mm-M-180
Connector location: CN5
4
2
1
10
9
1
Pin
Pin
Definition
1
Definition
SP5_DCD
Pin
2
Definition
SP5_RXD
1
GND
3
SP5_TXD
4
SP5_DTR
2
+12V
5
GND
6
SP5_DSR
3
CPUFANIN_P
7
SP5_RTS
8
SP5_CTS
4
CPUFANOUT_R
9
SP5_RI
10
GND
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
39
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 2: Jumpers and Connectors
Parallel Connector
Connector size: 2x13 26-pin box header, 2.0mm-M-180
Connector location: CN4
26
13
14
1
Pin
Definition
Pin
Definition
1
LPT_RP_STB#
14
LPT_AFD#R
2
LPT_RP_PRD0
15
LPT_ERR#
3
LPT_RP_PRD1
16
LPT_INIT#R
4
LPT_RP_PRD2
17
LPT_SLIN#R
5
LPT_RP_PRD3
18
GND_LPT
6
LPT_RP_PRD4
19
GND_LPT
7
LPT_RP_PRD5
20
GND_LPT
8
LPT_RP_PRD6
21
GND_LPT
9
LPT_RP_PRD7
22
GND_LPT
10
LPT_ACK#R
23
GND_LPT
11
LPT_BUSY
24
GND_LPT
12
LPT_PE
25
GND_LPT
13
LPT_SLCT
26
NC
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
40
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Chapter 3: System Setup
Removing the Chassis Cover
3. Lift up the cover and then remove it from the chassis.
Prior to removing the chassis cover, make sure the unit’s power is
off and disconnected from the power sources to prevent electric
shock or system damage.
1. The screws on the cover are used to secure the cover to the chassis.
2. Remove these screws and then put them in a safe place for later use.
The dots denote the locations of the screws.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
41
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Installing a DIMM
2. Note how the module is keyed to the socket. Grasping the module by
its edges, align the module with the socket so that the “notch” on the
module is aligned with the “key” on the socket. The key ensures the
module can be plugged into the socket in only one direction.
1.Push the ejector tabs which are at the ends of the socket outward. This
indicates that the socket is unlocked.
Ejector
tab
DIMM
sockets
Notch on the
module
Key on the
socket
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
42
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
3. Seat the module vertically, pressing it down firmly until it is completely
seated in the socket. The ejector tabs at the ends of the socket will automatically snap into the locked position to hold the module in place.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
43
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Installing the CPU
1. The CPU socket is readily accessible after you have removed the chassis
cover.
2. Make sure the screw is in its unlock position. If it’s not, use a screwdriver to turn the screw to its unlock position.
Screw in unlocked
position
CPU socket
• Make sure all power cables are unplugged before you install the
CPU.
• The CPU socket must not come in contact with anything other
than the CPU. Avoid unnecessary exposure.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
44
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
3. Position the CPU above the socket. The gold triangular mark on the
CPU must align with pin 1 of the CPU socket.
4. Insert the CPU into the socket until it is seated in place. The CPU will fit
in only one orientation and can easily be inserted without exerting any
force. Use a screwdriver to turn the screw to its lock position.
Screw in locked
position
Pin 1
Gold triangular mark
Do not force the CPU into the socket. Forcing the CPU into the
socket may bend the pins and damage the CPU.
Handle the CPU by its edges and avoid touching the pins.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
45
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
5. Before you install the heat sink, apply thermal paste onto the top of
the CPU. Do not spread the paste all over the surface. When you later
place the heat sink on top of the CPU, the compound will disperse
evenly.
6. Align the mounting holes of the heat sink with the mounting studs on
the board and then secure the heat sink with the provided screws.
Mounting stud
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
46
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Installing a SATA Hard Drive
1. With the bottom side of the chassis facing up, remove the screws of
the bottom cover.
3. Remove the drive bay. The drive bay is used to hold a SATA hard drive.
2. Remove the 4 mounting screws that secure the drive bay to the chassis.
If you are installing one SATA drive only, the system will allow you
to install an optional CompactFlash card, a half length SATA DOM
or a full length SATA DOM.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
47
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
4. Place the SATA hard drive on the drive bay. Make sure the connector
side of the SATA drive is facing the opening of the drive bay.
6. Connect the SATA data cable and SATA power cable to the connectors
on the SATA drive.
5. Align the mounting holes that are on the sides of the SATA drive with
the mounting holes on the drive bay then use the provided mounting
screws to secure the drive in place.
SATA power
cable
SATA data
cable
Connector side of
the SATA drive
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
48
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
7. Use the provided mounting screws to secure the drive bay to the chassis.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
49
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Installing a Half Length SATA DOM with SATA HD
If you intend to install a half length SATA DOM, you may install
one SATA hard drive only.
2. Locate for the SATA connector on the board.
1. Prior to installing the SATA DOM, you must first place the drive bay
shown below into the chassis.
SATA
connector
Drive bay
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
50
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
3. Align the SATA connector located on the solder side of the SATA DOM
to the SATA connector that is on the board and then press it down
firmly. Secure the SATA DOM with the provided mounting screw.
SATA DOM
Mounting screw
SATA connector
Solder side of
SATA DOM
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
51
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Installing a Full Length SATA DOM
If you intend to install a full length SATA DOM, you may install
one SATA hard drive only.
4. Before installing the single drive bay back, you must first replace the 4
mounting studs.
1. Prior to installing the full length SATA DOM, remove any drive bay that
may have been previously installed.
Now place the single drive bay by aligning the mounting holes of the
drive bay with the mounting studs.
2. Locate for the SATA connector on the board.
3. Align the SATA connector located on the solder side of the SATA DOM
to the SATA connector that is on the board and then press it down
firmly. Secure the SATA DOM with the provided mounting screw.
Mounting
hole
SATA DOM
Mounting screw
SATA connector
Solder side of
SATA DOM
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
52
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
5. Secure the drive bay with the provided mounting screws.
Mounting
screw
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
53
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Connecting to the Power Ignition Module (NISKIG120)
Introduction
The NISKIG120 is an external power ignition module that provides stable power to NViS 3540 series. Using this module will ensure that the device is well
shielded against premature failure at boot/shutdown phase. The following instructions will guide you on how to connect the NISKIG120 to the vehicle’s battery/ignition and NViS 3540 series.
Close-up view of the power input:
The following instructions use NViS 3540P8 as an example, but
can be applied to all other NViS 3540 series.
1. Connect the vehicle battery and ignition to the module’s power input
socket, refer to the pin/wiring definition table below:
5
1
Recommended wire gauge range: minimum of 10 AWG or above,
maximum length of 3 meters.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
54
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
Close-up view of the DC output:
2. Connect the module’s DC output to NViS 3540’s DC input, refer to the
pin/wiring definition table below:
6
6
1
1
Recommended wire gauge range: minimum of 16 AWG or above,
maximum length of 3 meters.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
55
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 3: System Setup
3. Connect the S3 control port to the Power Ignition port, refer to the pin/
wiring definition table below:
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
56
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Chapter 4: BIOS Setup
This chapter describes how to use the BIOS setup program for the NViS
3540 series. The BIOS screens provided in this chapter are for reference
only and may change if the BIOS is updated in the future.
The settings made in the setup program affect how the computer performs. It is important, therefore, first to try to understand all the Setup
options, and second, to make settings appropriate for the way you use the
computer.
To check for the latest updates and revisions, visit the NEXCOM Web site
at www.nexcom.com.tw.
When to Configure the BIOS
About BIOS Setup
This program should be executed under the following conditions:
▪▪ When changing the system configuration
The BIOS (Basic Input and Output System) Setup program is a menu driven
utility that enables you to make changes to the system configuration and
tailor your system to suit your individual work needs. It is a ROM-based
configuration utility that displays the system’s configuration status and
provides you with a tool to set system parameters.
▪▪ When a configuration error is detected by the system and you are
prompted to make changes to the Setup program
▪▪ When resetting the system clock
▪▪ When redefining the communication ports to prevent any conflicts
▪▪ When making changes to the Power Management configuration
▪▪ When changing the password or making other changes to the security
These parameters are stored in non-volatile battery-backed-up CMOS RAM
that saves this information even when the power is turned off. When the
system is turned back on, the system is configured with the values found
in CMOS.
setup
Normally, CMOS setup is needed when the system hardware is not consistent with the information contained in the CMOS RAM, whenever the
CMOS RAM has lost power, or the system features need to be changed.
With easy-to-use pull down menus, you can configure such items as:
▪▪ Hard drives, diskette drives, and peripherals
▪▪ Video display type and display options
▪▪ Password protection from unauthorized use
▪▪ Power management features
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
57
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Default Configuration
Legends
Most of the configuration settings are either predefined according to
the Load Optimal Defaults settings which are stored in the BIOS or are
automatically detected and configured without requiring any actions.
There are a few settings that you may need to change depending on your
system configuration.
Key
Entering Setup
When the system is powered on, the BIOS will enter the Power-On Self
Test (POST) routines. These routines perform various diagnostic checks; if
an error is encountered, the error will be reported in one of two different
ways:
▪▪ If the error occurs before the display device is initialized, a series of
beeps will be transmitted.
▪▪ If the error occurs after the display device is initialized, the screen will
display the error message.
Powering on the computer and immediately pressing <Del> allows you
to enter Setup. Another way to enter Setup is to power on the computer
and wait for the following message during the POST:
TO ENTER SETUP BEFORE BOOT
PRESS <CTRL-ALT-ESC>
Press the <Del> key to enter Setup:
Function
Right and Left arrows
Moves the highlight left or right to select a
menu.
Up and Down arrows
Moves the highlight up or down between submenus or fields.
<Esc>
Exits to the BIOS Setup Utility.
+ (plus key)
Scrolls forward through the values or options of
the highlighted field.
- (minus key)
Scrolls backward through the values or options
of the highlighted field.
Tab
Selects a field.
<F1>
Displays General Help.
<F10>
Saves and exits the Setup program.
<Enter>
Press <Enter> to enter the highlighted submenu.
Scroll Bar
When a scroll bar appears to the right of the setup screen, it indicates that
there are more available fields not shown on the screen. Use the up and
down arrow keys to scroll through all the available fields.
Submenu
When “u“ appears on the left of a particular field, it indicates that a
submenu which contains additional options are available for that field. To
display the submenu, move the highlight to that field and press <Enter>.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
58
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
BIOS Setup Utility
Memory Information
Displays the detected system memory information.
Once you enter the AMI BIOS Setup Utility, the Main Menu will appear on
the screen. The main menu allows you to select from six setup functions
and one exit choices. Use arrow keys to select among the items and press
<Enter> to accept or enter the submenu.
System Date
The date format is <day>, <month>, <date>, <year>. Day displays a day,
from Sunday to Saturday. Month displays the month, from January to December. Date displays the date, from 1 to 31. Year displays the year, from
1999 to 2099.
Main
The Main menu is the first screen that you will see when you enter the
BIOS Setup Utility.
Main
Advanced
BIOS SETUP UTILITY
PCIPnP
Boot
Security
BIOS Information
BIOS Vendor
Core Version
Project Version
Build Date
American Megatrends
4.6.3.7
N350-010 x64
07/28/2010 16:52:57
Memory Information
Total Memory
1024 MB (DDR3 1066)
System Date
System Time
[Wed 08/11/2010]
[16:51:35]
Access Level
Administrator
Chipset
System Time
The time format is <hour>, <minute>, <second>. The time is based on the
24-hour military-time clock. For example, 1 p.m. is 13:00:00. Hour displays
hours from 00 to 23. Minute displays minutes from 00 to 59. Second displays seconds from 00 to 59.
Exit
Use [ENTER], [TAB]
or [SHIFT-TAB] to
select a field.
Use [+] or [-] to
configure system Time.
→ ←:
↑↓: Select Screen
Select Item
Enter:Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
BIOS Information
Displays the detected BIOS information.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
59
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Advanced
CPU Configuration
This section is used to configure the CPU. It will also display detected CPU
information.
The Advanced menu allows you to configure your system for basic operation. Some entries are defaults required by the system board, while others,
if enabled, will improve the performance of your system or let you set
some features according to your preference.
SATA Configuration
This section is used to configure the SATA drives.
Setting incorrect field values may cause the system to malfunction.
Main
Advanced
Legacy OpROM Support
Launch PXE OpROM

S5 RTC Wake Settings

CPU Configuration

SATA Configuration

Intel IGD SWSCI OpRegion

Intel TXT(LT) Configuration

USB Configuration

Super IO Configuration

H/W Monitor

Thermal Configuration

AMT Configuration
BIOS SETUP UTILITY
PCIPnP
Boot
Security
[Disabled]
Chipset
Intel IGD SWSCI OpRegion
Configures the Intel graphics display.
Intel TXT(LT) Configuration
Configures the Intel Trusted Execution technology.
Exit
Enable or Disable Boot
Option for Legacy
Network Devices.
USB Configuration
Configures the USB devices.
Super IO Configuration
This section is used to configure the I/O functions supported by the onboard Super I/O chip.
→ ←:
↑↓: Select Screen
Select Item
Enter:Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
H/W Monitor
This section is used to configure the hardware monitoring events such as
temperature, fan speed and voltages.
Thermal Configuration
Configures the intelligent power sharing function.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Launch PXE OpROM
Enables or disables the boot option for legacy network devices.
AMT Configuration
Configures the AMT function.
S5 RTC Wake Settings
Configures the S5 RTC wake up setting.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
60
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
S5 RTC Wake Settings
CPU Configuration
This section is used to configure the wake up function.
This section is used to configure the CPU. It will also display detected
CPU information.
BIOS SETUP UTILITY
Advanced
Wake System with Fixed Time
BIOS SETUP UTILITY
[Disabled]
Advanced
Enable or Disable
system wake on alarm
event. When enabled,
system will wake on the
hr::min::sec specified.
CPU Configuration
Intel(R) Core(TM) i5 CPU M 540 @ 2.53GHz
Supported
EMT64
2527 MHz
Processor Speed
20652
Processor Stepping
9
Microcode Revision
2
Processor Cores
Supported
Intel HT Technology
→ ←:
↑↓: Select Screen
Select Item
Enter:Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Hyper-Threading
Active Processor Cores
Limit CPUID Maximum
Hardware Prefetcher
Adjacent Cache Line Prefetch
Intel Virtualization Technology
Power Technology
TDC Limit
TDP Limit
[Enabled]
[A11]
[Disabled]
[Enabled]
[Enabled]
[Disabled]
[Energy Efficient]
0
0
Enabled for Windows XP
and Linux (OS optimized
for Hyper-Threading
Technology) and Disabled
for other OS (OS not
optimized for
Hyper-Threading
Technology). When
Disabled only one thread
per enabled core is
enabled.
→ ←:
↑↓: Select Screen
Select Item
Enter:Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Wake System with Fixed Time
Hyper-Threading
Enables or disables the system’s wake on alarm event. When enabled, the
system will wake up on the specified time.
Enable this field for Windows XP and Linux which are optimized for HyperThreading technology. Select disabled for other OSes not optimized for
Hyper-Threading technology. When disabled, only one thread per enabled
core is enabled.
Active Processor Cores
Used to enter the number of cores to enable in each processor package.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
61
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Limit CPUID Maximum
SATA Configuration
The CPUID instruction of some newer CPUs will return a value greater
than 3. The default is Disabled because this problem does not exist in the
Windows series operating systems. If you are using an operating system
other than Windows, this problem may occur. To avoid this problem, enable this field to limit the return value to 3 or lesser than 3.
This section is used to configure the SATA drives.
BIOS SETUP UTILITY
Advanced
SATA Configuration
SATA Port
SATA Port
SATA Port
SATA Port
Hardware Prefetcher
1
2
3
4
SATA Mode
Turns on or off the MLC streamer prefetcher.
Adjacent Cache Line Prefetch
Not
Not
Not
Not
Present
Present
Present
Present
(1) IDE Mode.
(2) AHCI Mode.
(3) RAID Mode.
[IDE Mode]
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Enables or disables the adjacent cache line prefetch.
Intel Virtualization Technology
When this field is set to Enabled, the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Power Technology
SATA Mode
Configures the power management features.
IDE Mode This option configures the Serial ATA drives as Parallel ATA
storage devices.
AHCI Mode This option allows the Serial ATA devices to use AHCI (Advanced Host Controller Interface).
RAID Mode This option allows you to create RAID or Intel Matrix Storage configuration on Serial ATA devices.
TDC Limit
Used to select the TDC limit.
TDP Limit
Used to select the TDP limit.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
62
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Intel IGD SWSCI OpRegion
Intel TXT(LT) Configuration
This section is used to configure the Intel graphics display.
This section is used to configure the Intel Trusted Execution technology.
BIOS SETUP UTILITY
BIOS SETUP UTILITY
Advanced
Advanced
Intel IGD SWSCI OpRegion Configuration
DVMT/FIXED Memory
IGD - Boot Type
LCD Panel Type
[256MB]
[CRT + DVI]
[VBIOS Default]
Intel Trusted Execution Technology Configuration
Select DVMT/FIXED
Mode Memory size used
by Internal Graphics
Device
→ ←: Select
↑↓: Select
Intel TXT(LT) Support
[Disabled]
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
DVMT/FIXED Memory
Intel TXT(LT) Support
Selects the DVMT/FIXED mode memory size used by the internal graphics
device.
The options are Enabled and Disabled.
IGD - Boot Type
Selects the video device that will be activated during POST. This will not
affect any external graphics that may be present.
LCD Panel Type
Selects the LCD panel used by the internal graphics device.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
63
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
USB Configuration
Super IO Configuration
This section is used to configure USB devices.
This section is used to configure the I/O functions supported by the onboard Super I/O chip.
BIOS SETUP UTILITY
Advanced
BIOS SETUP UTILITY
USB Configuration
USB Devices:
1 Mouse, 1 Hub
Legacy USB Support
EHCI Hand-off
Device Reset Timeout
[Enabled]
[Enabled
[20 Sec]
Advanced
Enables Legacy USB
support. AUTO option
disables legacy support if
no USB devices are
connected. DISABLE
option will keep USB
devices available only for
EFI applications.
Super IO Configuration
Super IO Chip
Serial Port 0 Configuration
Serial Port 1 Configuration
Serial Port 2 Configuration
Serial Port 3 Configuration
Serial Port 4 Configuration
Parallel Port Configuration
ITE IT8783F
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Set Parameters of Serial
Port 1 (COMA)
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Legacy USB Support
Serial Port 0 Configuration to Serial Port 4 Configuration
Enabled Enables legacy USB.
Auto Disables support for legacy when no USB devices are connected.
Disabled Keeps USB devices available only for EFI applications.
Selects the IO/IRQ setting of the I/O devices.
Parallel Port Configuration
Configures the parallel port.
EHCI Hand-off
This is a workaround for OSes that does not support EHCI hand-off. The
EHCI ownership change should be claimed by the EHCI driver.
Device Reset Timeout
Selects the USB mass storage device start unit command timeout.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
64
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
H/W Monitor
CPU:Vcore to +12V
This section is used to configure the hardware monitoring events such as
temperature, fan speed and voltages.
Detects and displays the output voltages.
BIOS SETUP UTILITY
Advanced
PC Health Status
Fan Setting
System Temperature
CPU Temperature
System FAN Speed
CPU FAN Speed
CPU:Vcore
+3.3V
+5V
+12V
[Always Full Speed]
: +30 C
: +28 C
: N/A
: N/A
: +1.056V
: +3.296 V
: +4.915V
: +11.932 V
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Fan Setting
Selects the speed of the fan.
System Temperature and CPU Temperature
Detects and displays the internal temperature of the system and the current
temperature of the CPU.
System Fan Speed to CPU Fan Speed
Detects and displays the current system fan and CPU fan speed in RPM
(Revolutions Per Minute).
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
65
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Thermal Configuration
This section is used to configure the intelligent power sharing function.
BIOS SETUP UTILITY
Advanced
Intelligent Power Sharing
[Disabled]
Intelligent power sharing
configuration menu. Note:
DTS must be enabled for
Power Sharing to function.
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Intelligent Power Sharing
Enables or disables the power sharing function.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
66
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
AMT Configuration
OS Watchdog Timer
This section is used to configure the AMT function.
Selects the time interval of the OS Watchdog Timer.
BIOS Watchdog Timer
BIOS SETUP UTILITY
Advanced
AMT
Unconfigure AMT/ME
Watchdog Timer
OS Watchdog Timer
BIOS Watchdog Timer
[Enabled]
[Disabled]
[Disabled]
0
0
Selects the time interval of the BIOS Watchdog Timer.
AMT Help
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
AMT
Enables or disables the AMT function.
Unconfigure AMT/ME
Select Enabled to unconfigure the AMT/ME function without the need for
a password.
Watchdog Timer
Enables or disables the Watchdog Timer function.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
67
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Chipset
Initiate Graphic Adapter
This section is used to configure the system based on the specific features
of the chipset.
Selects the graphics controller to use as the primary boot device.
VT-d
Setting incorrect field values may cause the system to malfunction.
The options are Enabled and Disabled.
IGD Memory
Selects the internal graphics device’s shared memory size.
North Bridge
BIOS SETUP UTILITY
Chipset
CPU Type
Arrandale
Total Memory
1024 MB (DDR3 1066)
Memory Slot 0
Memory Slot 1
1024 MB (DDR3 1066)
0 MB (DDR3 1066)
CAS# Latency (tCL)
RAS# Active Time (tRAS)
Row Precharge Time (tRP)
RAS# to CAS# Delay (tRCD)
Write Recovery Time (tWR)
Row Refresh Cycle Time (tRFC)
Write to Read Delay (tWTR)
Active to Active Delay (tRRD)
Read CAS# Precharge (tRTP)
7
20
7
7
8
60
4
4
5
Initiate Graphic Adapter
[PEG/IGD]
VT-d
[Disabled]
IGD Memory
[32M]
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
68
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
South Bridge
Restore AC Power Loss
Off When power returns after an AC power failure, the system’s power is
off. You must press the Power button to power-on the system.
On When power returns after an AC power failure, the system will automatically power-on.
BIOS SETUP UTILITY
Chipset
SB Chipset Configuration
SMBus Controller
GbE Controller
Wake On Lan From S5
[Enable]
[Enable]
[Enable]
Restore AC Power Loss
[Power On]
Azalia HD Audio
Audio Configuration
Azalia HD Audio
Azalia Internal HDMI Codec
[Enabled]
[Enabled]
Enables or disables the Azalia HD audio.
High Precision Event Timer Configuration
High Precision Timer
[Enabled]
 USB
Azalia Internal HDMI Codec
Configuration
Enables or disables the Azalia internal HDMI codec.
High Precision Timer
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Enables or disables the high precision event timer.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
SMBus Controller
Enables or disables the SMBus controller.
GbE Controller
Enables or disables the Gigabit LAN controller.
Wake On Lan From S5
When enabled, it allows the system to wake up from S5 via the network
LAN.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
69
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
USB Configuration
Intel ME Configuration
BIOS SETUP UTILITY
BIOS SETUP UTILITY
Advanced
Chipset
USB Configuration
All USB Devices
[Enabled]
EHCI Controller 1
EHCI Controller 2
[Disabled]
[Enabled]
Enable/Disable All USB
Devices
ME Subsystem Help
Intel ME Subsystem Configuration
ME Version
6.0.3.1195
ME Subsystem
End of Post Message
Execute MEBx
[Enabled]
[Enabled]
[Enabled]
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
All USB Devices
ME Subsystem
Enables or disables all USB devices.
The options are Enabled and Disabled.
EHCI Controller 1 and EHCI Controller 2
End of the POST Message
Enables or disables the Enhanced Host Controller Interface (USB 2.0).
The options are Enabled and Disabled.
Execute MEBx
The options are Enabled and Disabled.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
70
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Boot
Bootup NumLock State
This allows you to determine the default state of the numeric keypad. By
default, the system boots up with NumLock on wherein the function of
the numeric keypad is the number keys. When set to Off, the function of
the numeric keypad is the arrow keys.
BIOS SETUP UTILITY
Main
Advanced
Chipset
Boot
Security
Save & Exit
Boot Configuration
Quiet Boot
Fast Boot
Setup Prompt Timeout
[Disabled]
[Disabled]
1
Bootup NumLock State
[On]
CSM16 Module Version
07.60
GateA20 Active
Option ROM Messages
Interrupt 19 Capture
[Upon Request]
[Force BIOS]
[Disabled]
Boot Option Priorities
Boot Option #1
Boot Option #2
[SATA: FUJITSU MH...]
[Built-in EFI Shell]
Hard Drive BBS Priorities
Enables/Disables Quiet
Boot option
Gate A20 Active
Configures the Gate A20 function.
Option ROM Messages
← →: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Configures the ROM messages.
Interrupt 19 Capture
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
When enabled, it allows the optional ROM to trap interrupt 19.
Quiet Boot
Boot Option #1 and Boot Option #2
Enables or disables the quiet boot function.
Selects the boot sequence of the hard drives.
Fast Boot
Hard Drive BBS Priorities
Enables or disables boot with initialization of a minimal set of devices
required to launch active boot option. This doesn’t affect the BBS boot
options.
Sets the order of the legacy devices in this group.
Setup Prompt Timeout
Selects the number of seconds to wait for the setup activation key.
65535(0xFFFF) denotes indefinite waiting.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
71
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 4: BIOS Setup
Security
Save & Exit
BIOS SETUP UTILITY
BIOS SETUP UTILITY
Main
Advanced
Chipset
Boot
Security
Main
Save & Exit
Password Description
If only the Administrator’s password is set, then
this only limits access to Setup and is only asked
for when entering Setup.
If only the User’s password is set, then this is
a power on password and must be entered to
boot or enter setup. In Setup the User will have
Administrator rights.
Advanced
Chipset
Boot
Save Changes and Exit
Discard Changes and Exit
Save Changes and Reset
Discard Changes and Reset
Set Setup Administrator
Password.
Security
Save & Exit
Reset the system after
saving the changes.
Save Options
Save Changes
Discard Changes
Restore Defaults
Save as User Defaults
Restore User Defaults
Administrator Password
User Password
→ ←: Select
↑↓: Select
Screen
Item
Boot Override
SATA: FUJITSU MHZ2080BH G2
Built-in EFI Shell
Reset System with ME Disable Mode
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
← →: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Administrator Password
Save Changes and Exit
Sets the administrator password.
User Password
To save the changes and exit the Setup utility, select this field then press
<Enter>. A dialog box will appear. Confirm by selecting Yes. You can also
press <F10> to save and exit Setup.
Sets the user password.
Discard Changes and Exit
To exit the Setup utility without saving the changes, select this field then
press <Enter>. You may be prompted to confirm again before exiting. You
can also press <ESC> to exit without saving the changes.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
72
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
Chapter 5: AMT Settings
Enable Intel® AMT in the AMI BIOS
1. In the Advanced menu, select AMT Configuration.
Main
Advanced
Legacy OpROM Support
Launch PXE OpROM

S5 RTC Wake Settings

CPU Configuration

SATA Configuration

Intel IGD SWSCI OpRegion

Intel TXT(LT) Configuration

USB Configuration

Super IO Configuration

H/W Monitor

Thermal Configuration

AMT Configuration
BIOS SETUP UTILITY
PCIPnP
Boot
Security
[Disabled]
2. In the AMT field, select Enabled.
BIOS SETUP UTILITY
Chipset
Advanced
Exit
AMT
Unconfigure AMT/ME
Watchdog Timer
OS Watchdog Timer
BIOS Watchdog Timer
Enable or Disable Boot
Option for Legacy
Network Devices.
→ ←:
↑↓: Select Screen
Select Item
Enter:Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
AMT Help
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
[Enabled]
[Disabled]
[Disabled]
0
0
73
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
Configure the Intel® ME Setup
2. You will be prompted for a password. The default password is “admin”.
Enter the default password in the space provided under Intel(R) ME Password and then press Enter.
1. When the system reboots, the following message will be displayed. Press
<Ctrl-P> as soon as the message is displayed; as this message will be displayed for only a few seconds.
Intel(R) Management Engine BIOS Extension v6.0.3.0019
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
Intel(R) ME Firmware version 6.0.3.1195
Press <CTRL-ALT F1> to enter Remote Assistance
Press <CTRL-P> to enter Intel(R) ME Setup
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit


Intel(R) ME Password
*****
[ESC] : Exit
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
74
[ENTER] : Submit
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
3. Enter a new password in the space provided under Intel(R) ME New
Password and then press Enter. The new password must be based on the
following rules to create a strong password security.
•
•
4. You will be asked to verify the password. Enter the same new password in
the space provided under Verify Password and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
Password length - at least 8 characters and not longer than 32.
Password complexity - the password must include the following.
- At least one digit character (0, 1, ...9)
- At least one 7-bit ASCII non alpha-numeric character (e.g. !, $, ;) but
excluding : , and ” characters
- At least one lowercase letter (‘a’, ‘b’...’z’) and at least one uppercase
letter (‘A’, ‘B’...’Z’)
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit


Verify Password


[ESC] : Exit
[ENTER] : Submit
Intel(R) ME New Password
[ESC] : Exit
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
[ENTER] : Submit
75
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
5.Select Intel(R) ME General Settings and then press Enter.
6.Select Intel(R) ME State Control and then press Enter.
Select Enabled and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit
[ESC] : Exit
[↑↓] : Select
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Intel(R) ME State Control
Change ME Password
Password Policy
Network Setup 
Activate Network Access
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings 


[ENTER] : Access
[ESC] : Exit
[↑↓] : Select
[ENTER] : Access
[*] DISABLED
[*] ENABLED
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
76
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
7.Select Network Setup and then press Enter.
8. In the Intel(R) Network Setup menu, select Intel(R) ME Network Name
Settings then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Intel(R) ME State Control
Change ME Password
Password Policy
Network Setup 
Activate Network Access
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings 
[ESC] : Exit
[↑↓] : Select
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) NETWORK SETUP ]
Intel(R) ME Network Name Settings TCP/IP Settings
Previous Menu
[ENTER] : Access
[ESC] : Exit
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.


77
[↑↓] : Select
[ENTER] : Access
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
9. In the Intel(R) ME Network Name Settings menu, select Host Name and
then press Enter.
Enter the computer’s host name (for example: QM57) and then press Enter.
Select Previous Menu and then press Enter.
10. In the Network Setup menu, select TCP/IP Settings and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) NETWORK SETUP ]
Intel(R) ME Network Name Settings TCP/IP Settings
Previous Menu
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.9.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[
INTEL(R) ME NETWORK NAME SETTINGS
Host Name
Domain Name
Shared/Dedicated FQDN
Dynamic DNS Update
Previous Menu
[↑↓] : Select
[ESC] : Exit
]
[ESC] : Exit
[↑↓] : Select


[ENTER] : Access
[ENTER] : Access
Computer host name
QM57
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
78
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
11. In the TCP/IP Settings menu, select Wired LAN IPV4 Configuration and
then press Enter.
12.Select DHCP Mode and then press Enter.
Select Enabled or Disabled and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ TCP/IP SETTINGS ]
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[
WIRED LAN IPV4 CONFIGURATION
Wired LAN IPV4 Configuration 
Wired LAN IPV6 Configuration 
Previous Menu
[ESC] : Exit
[↑↓] : Select
]
DHCP Mode
Previous Menu
[ENTER] : Access
[ESC] : Exit
[↑↓] : Select
[ENTER] : Access
[*] DISABLED
[*] ENABLED
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
79
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
13. A list of options in the Wired LAN IPV4 Configuration menu will appear.
14.Select Subnet Mask Address and then press Enter.
Select IPV4 Address and then press Enter. Enter an IP Address then
press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.9.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[
WIRED LAN IPV4 CONFIGURATION
Enter the subnet mask address and then press Enter.
[
WIRED LAN IPV4 CONFIGURATION
]
]
DHCP Mode
IPV4 Address
Subnet Mask Address
Default Gateway Address
Preferred DNS Address
Alternate DNS Address
Previous Menu
DHCP Mode
IPV4 Address
Subnet Mask Address
Default Gateway Address
Preferred DNS Address
Alternate DNS Address
Previous Menu
[ESC] : Exit
[↑↓] : Select
[ENTER] : Access
Subnet mask (e.g. 255.255.255.0)
IP address (e.g. 123.123.123.100)
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
80
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
15.Select Default Gateway Address and then press Enter.
16.Select Previous Menu and then press Enter.
Enter the default gateway address and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) NETWORK SETUP ]
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[
WIRED LAN IPV4 CONFIGURATION
]
Intel(R) ME Network Name Settings TCP/IP Settings
Previous Menu
DHCP Mode
IPV4 Address
Subnet Mask Address
Default Gateway Address
Preferred DNS Address
Alternate DNS Address
Previous Menu
[ESC] : Exit
[↑↓] : Select
[ESC] : Exit
[↑↓] : Select


[ENTER] : Access
[ENTER] : Access
Default Gateway Address
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
81
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
17. Select Previous Menu until you return to the Intel(R) ME Platform Configuration menu.
18.Type Y and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Intel(R) ME State Control
Change ME Password
Password Policy
Network Setup 
Activate Network Access
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings 
Select Activate Network Access and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Intel(R) ME State Control
Change ME Password
Password Policy
Network Setup 
Activate Network Access
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings 
[ESC] : Exit
[↑↓] : Select
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
[ESC] : Exit
[↑↓] : Select
[ENTER] : Access
[Caution]
Activates the current network settings
and opens the ME network interface
Continue: (Y/N)
[ENTER] : Access
82
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
19. In the Intel(R) ME Platform Configuration menu, select Unconfigure
Network Access and then press Enter. Clear all network settings.
20. In the Intel(R) ME Platform Configuration menu, select Power Control
and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Intel(R) ME State Control
Change ME Password
Password Policy
Network Setup 
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings 
Set PRTC
[ESC] : Exit
[↑↓] : Select
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Change ME Password
Password Policy
Network Setup 
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings

Set PRTC
Power Control 
[ESC] : Exit
[ENTER] : Access
83
[↑↓] : Select
[ENTER] : Access
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
21. In the Intel(R) ME Power Control menu, select Intel(R) ME ON in Host
Sleep States and then press Enter.
22.Select Previous Menu and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME PLATFORM CONFIGURATION ]
Password Policy
Network Setup 
Unconfigure Network Access
Remote Setup and Configuration 
FW Update Settings

Set PRTC
Power Control 
Previous Menu
Select Mobile: ON in S0 and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) ME POWER CONTROL ]
Intel(R) ME ON in Host Sleep States
Idle Timeout
Previous Menu
[ESC] : Exit
[ESC]=Exit
[↑↓]=Select
[↑↓] : Select
[ENTER] : Access
[ENTER]=Access
[*] Mobile: ON in S0
[*] Mobile: ON in S0, ME Wake in S3, S4-5 (AC only)
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
84
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
23. Select Previous Menu until you return to the Main Menu. Select Intel(R)
AMT Configuration.
24. The message below will appear.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit


[ESC]=Exit
[ESC]=Exit
[↑↓]=Select
[↑↓]=Select


[ENTER]=Access
[ENTER]=Access
Update network settings in the General Settings menu
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
85
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
25. In the Intel(R) AMT Configuration menu, select SOL/IDER and then press
Enter.
26. In the SOL/IDER menu, select Username & Password and then press
Enter.
Select Enabled and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) AMT CONFIGURATION ]
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ SOL/IDER ]
Username & Password
SOL
IDER
Legacy Redirection Mode
Previous Menu
Manageability Feature Selection
SOL/IDER
KVM Configuration
Previous Menu
[ESC]=Exit
[↑↓]=Select
[ENTER]=Access
[ESC]=Exit
[↑↓]=Select
[ENTER]=Access
[*] DISABLED
[*] ENABLED
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
86
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
27. In the SOL/IDER menu, select SOL and then press Enter.
28. In the SOL/IDER menu, select IDER and then press Enter.
Select Enabled and then press Enter.
Select Enabled and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ SOL/IDER ]
Username & Password
SOL
IDER
Legacy Redirection Mode
Previous Menu
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ SOL/IDER ]
Username & Password
SOL
IDER
Legacy Redirection Mode
Previous Menu
[ESC]=Exit
[↑↓]=Select
[ESC]=Exit
[ENTER]=Access
[ENTER]=Access
[*] DISABLED
[*] ENABLED
[*] DISABLED
[*] ENABLED
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
[↑↓]=Select
87
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
29. In the SOL/IDER menu, select Legacy Redirection Mode and then press
Enter.
30.Select Enabled and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.31195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ SOL/IDER ]
Username & Password
SOL
IDER
Legacy Redirection Mode
Previous Menu
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.31195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ SOL/IDER ]
Username & Password
SOL
IDER
Legacy Redirection Mode
Previous Menu
[ESC]=Exit
[ESC]=Exit
[↑↓]=Select
[ENTER]=Access
[↑↓]=Select
[ENTER]=Access
[*] DISABLED
[*] ENABLED
Redirection Mode must be enabled when using
a legacy SMB Redirection Console
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
88
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
31. Select Previous Menu until you return to the Intel(R) AMT Configuration menu.
32. In the KVM Configuration menu, select KVM Feature Selection and
then press Enter.
Select KVM Configuration and then press Enter.
Select Enabled and then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ INTEL(R) AMT CONFIGURATION ]
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ KVM CONFIGURATION ]
KVM Feature Selection
User Opt-in
Opt-in Configurable from remote IT
Previous Menu
Manageability Feature Selection
SOL/IDER
KVM Configuration
Previous Menu
[ESC]=Exit
[↑↓]=Select
[ESC]=Exit
[ENTER]=Access
[↑↓]=Select
[ENTER]=Access
[*] DISABLED
[*] ENABLED
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
89
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
33. In the KVM Configuration menu, select User Opt-in and then press
Enter.
34. In the KVM Configuration menu, select Opt-in Configurable from
Remote IT and then press Enter.
Select User Consent is required for KVM Session and then press Enter.
Select Enable Remote Control of KVM Opt-in Policy and then press
Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ KVM CONFIGURATION ]
KVM Feature Selection
User Opt-in
Opt-in Configurable from remote IT
Previous Menu
[ESC]=Exit
[↑↓]=Select
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ KVM CONFIGURATION ]
KVM Feature Selection
User Opt-in
Opt-in Configurable from remote IT
Previous Menu
[ENTER]=Access
[ESC]=Exit
[*] User Consent is not required for KVM Session
[*] User Consent is required for KVM Session
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
[↑↓]=Select
[ENTER]=Access
[*] Disable Remote Control of KVM Opt-in Policy
[*] Enable Remote Control of KVM Opt-in Policy
90
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
35.Select Previous Menu.
36. Select Previous Menu until you return to the Main Menu. Select Exit and
then press Enter.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ KVM CONFIGURATION ]
KVM Feature Selection
User Opt-in
Opt-in Configurable from remote IT
Previous Menu
The following message will be displayed on the screen.
[CONFIRM EXIT]
Are you sure you want to exit? (Y/N):
Press Y.
Intel(R) Management Engine BIOS Extension v6.0.3.0019/Intel(R) ME v6.0.3.1195
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ESC]=Exit
[↑↓]=Select
[ENTER]=Access
Intel(R) ME General Settings
Intel(R) AMT Configuration Exit
[ESC] : Exit
[↑↓] : Select


[ENTER] : Access
[ CONFIRM EXIT ]
Are you sure you want to exit? (Y/N):
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
91
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
Unconfigure AMT/ME
1. In the Advanced menu, select AMT Configuration.
Main
Advanced
Legacy OpROM Support
Launch PXE OpROM

S5 RTC Wake Settings

CPU Configuration

SATA Configuration

Intel IGD SWSCI OpRegion

Intel TXT(LT) Configuration

USB Configuration

Super IO Configuration

H/W Monitor

Thermal Configuration

AMT Configuration
BIOS SETUP UTILITY
PCIPnP
Boot
Security
[Disabled]
2. In the Unconfigure AMT/ME field, select Enabled. Clear all ME settings.
Chipset
BIOS SETUP UTILITY
Exit
Advanced
Enable or Disable Boot
Option for Legacy
Network Devices.
AMT
Unconfigure AMT/ME
Watchdog Timer
OS Watchdog Timer
BIOS Watchdog Timer
→ ←:
↑↓: Select Screen
Select Item
Enter:Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
AMT Help
→ ←: Select
↑↓: Select
Screen
Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save ESC: Exit
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
[Enabled]
[Enabled]
[Disabled]
0
0
Version 2.00.1201. Copyright (C) 2009 American Megatrends, Inc.
92
NViS 3540/3540H/3540P4/3540P8 User Manual
Chapter 5: AMT Settings
3. The message below will appear. Type Y.
Intel(R) Management Engine BIOS Extension v6.0.3.0019
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
Found unconfigure of Intel(R) ME
Continue with unconfiguration (Y/N)
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
93
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix A: Power Consumption
Appendix A: Power Consumption
Test Configuration
System Configuration
Sys#1
Sys#2
Sys#3
Chassis
CHASSIS NViS 3540 Ver. A
CHASSIS NViS 3540 Ver. A
CHASSIS NViS 3540 Ver. A
CPU
Intel® Core™ i7-620M Processor (4M Cache, 2.66
GHz) 35W
Intel CPU Celeron Processor P4500 (2M Cache,
1.86 GHz)
Intel® Core™ i5-520M Processor (3M Cache, 2.4
GHz) 35W
Memory
Transcend DDR3 1066 2Gx2
Transcend DDR3 1066 2Gx2
Transcend DDR3 1066 2Gx2
HDD
Hitachi HTS23225L9A360 250GB
Hitachi HTS23225L9A360 250GB
Hitachi HTS23225L9A360 250GB
FDD
N/A
N/A
N/A
CD-ROM
N/A
N/A
N/A
Compact Flash device
N/A
N/A
N/A
Power Supply
POWER ADAPTER SPI:G.P FSP120-AAB(N091)
POWER ADAPTER SPI:G.P FSP120-AAB(N091)
POWER ADAPTER SPI:G.P FSP120-AAB(N091)
Add-on Card
D-LINK LAN Card
D-LINK LAN Card
D-LINK LAN Card
CPU Cooler
NViS 3540 HEATSINK
NViS 3540 HEATSINK
NViS 3540 HEATSINK
System Fan
N/A
N/A
N/A
Keyboard
LEMEL B-5201-P
LEMEL B-5201-P
LEMEL B-5201-P
Mouse
GENIVS EASY MOUSE PS/2
GENIVS EASY MOUSE PS/2
GENIVS EASY MOUSE PS/2
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
94
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix A: Power Consumption
Power Consumption Measurement
Test Data
Purpose
Sys #1
The purpose of the power consumption test is to verify the power dissipation of the system and the load of the power supply.
Full-Loading Mode
Test Equipment
PROVA CM-07 AC/DC CLAMP METER
Sys #2
+19V
+19V
2.97A
2.43A
Total
56.43W
46.17W
Standby Mode
1.025A
0.99A
19.475W
18.81W
Total
Device Under Test
DUT: Sys #1 / Sys #2
Test Procedure
1.Power up the DUT and then boot Windows XP.
2.Enter the standby mode (HDD power down).
3.Measure the power consumption and record it.
4.Run the Burn-in test program to apply 100% full loading.
5.Run the Intel Kpower program.
5.Run the LAN Packet Counter and Receive program.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
95
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix B: GPI/O Programming Guide
Appendix B: GPI/O Programming guide
IO base address : 800h
NISB3500 GPIO
PIN
Description
PIN
Description
1
+5V
2
GND
3
GPO24
4
GPI20
5
GPO25
6
GPI21
7
GPO26
8
GPI22
9
GPO27
10
GPI23
Bit0 : GPI20
Bit1 : GP I21
Bit2 : GP I22
Bit3 : GP I23
Bit4 : GPO24
Bit5 : GPO25
Bit6 : GPO26
Bit7 : GPO27
1. Read/Write GPIO data by I/O port 801h
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
96
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix C: Watchdog Timer Setting
Appendix C: Watchdog Timer Setting
Start
Step 1
See “SetupWDT” procedure
#Setup Watchdog Timer Environment
Step 2
See “TimeBaseWDT” procedure
#Initial Watchdog Timer
Users can select second or minute
Step 3
See “TimeCountWDT” procedure
#Set Watchdog Timer Time-out Value
Users can set time-out value
Step 4
See ExitSetup procedure
#Exit Setup Environment
End
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
97
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix C: Watchdog Timer Setting
c:\>debug [enter]
-o 2e 87 ;Enter the Extended Function Mode
-o 2e 01
-o 2e 55
-o 2e 55
-o 2e 07 ;Logical Device Number Reg
-o 2f 07 ;LDN=7
-o 2e 72 ;Watch dog configuration
-o 2f XX ;minute mode or second mode
-o 2e 73 ;LSB for Watch dog tme out value
-o 2f YY
-o 2e 74 ;MSB for Watch dog tme out value
-o 2f ZZ
XX: 90 : Second mode
10 : minute mode
ex:
10 second timeout:
xx=90
yy=0a
zz=00
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
98
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
Appendix D: Intel Embedded AMT Management Express KVM
1. After installing the Intel Embedded AMT Management Express utility,
the Intel Embedded AMT Management Express icon will appear on
your desktop.
3. When the Intel Embedded AMT Management Express dialog box appears, click Accept.
2. Double-click the icon to run Intel Embedded AMT Management Express.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
99
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
4. Click the first icon in the toolbar (top row).
5. Enter a range of IP addresses that is within the network to find iAMT
computers.
6. Click the Start Scan icon.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
100
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
8.Click Add Device. A dialog box will appear.
7. The iAMT computers that were detected within the network will appear under the Discovered Devices list.
Enter the ME BIOS’ username “admin” and password. Click OK.
9. After you have added the iAMT computer, a dialog box will appear
informing you that the device was added successfully. Click OK.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
101
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
10. In the Intel Embedded AMT Management Express main menu, you
will notice the Device-1 icon in the Device section.
11. Click the 5th icon (Connect to Selected Device) in the toolbar to connect to the remote iAMT computer.
Move the cursor to Device-1 and you will see the remote iAMT computer’s IP address.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
102
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
12. In the Connection dialog box, enter the remote computer’s IP address,
ME BIOS’ username “admin” and password.
13. Once the server is connected to the remote computer, the message
Connection Status: Connection Established will appear at the bottom of the screen.
Click the Connect icon to connect to the remote computer.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
103
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
14. In the Intel Embedded AMT Management Express main menu, click
the KVM icon.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
15. The Remote KVM screen will appear. In the KVM Password field, enter
the ME BIOS admin’s password and then click the Start Session icon.
104
You will be prompted to enter the VNC’s password.
Enter the 6-character password that appeared on the remote computer.
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix D: Intel Embedded AMT Management Express KVM
16. When the server is connected to the remote iAMT computer, the
server will be able to see the remote computer’s current image.
If you entered the wrong password thrice, a message will appear notifying you that the server and remote computer’s VNC
connection failed. You must click the KVM icon again and then
select KVM Viewer Redirect Port to reconnect.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
105
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix E: Intel Manageability Command Tool-KVM
Appendix E: Intel Manageability Command Tool - KVM
1. After installing the Intel Manageability Commander Tool, the Manageability Commander Tool icon will appear on your desktop.
3. Enter a range of IP addresses that is within the network. Enter the
Start IP address and End IP address.
4.Click Start to search for iAMT computers that are in the designated
range.
2. Double-click the icon to run Manageability Commander Tool.
The Network Discovery screen allows you to scan to find iAMT computers (with the ME BIOS configured) on the specified range of IP addresses.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
106
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix E: Intel Manageability Command Tool-KVM
5. The detected iAMT computer will appear in the Discovered Computers
field.
6. After adding the iAMT computer, a dialog box will appear. Enter the
username “admin” and password used by the ME BIOS of the iAMT
computer.
You can either click Add Known Computer to add the iAMT computer to the Network list on the left column or double-click the computer
name under the Discovered Computers list.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
Click OK.
107
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix E: Intel Manageability Command Tool-KVM
7. The newly added iAMT computer with its IP address will appear under
the Network list located at the left column of the screen.
8. On the left column, under Network, select the iAMT computer. The
Connect & Control screen will appear on the right side.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
108
Select the Connection tab and then click Connect. The Manageability
Commander Tool will connect the iAMT computer with the server.
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix E: Intel Manageability Command Tool-KVM
9. The iAMT computer’s icon under the Network list will turn from gray to
blue. The server and iAMT computer are now connected.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
10. Display the hierarchical structure of the iAMT computer’s files and
folders. This will allow you to view the remote computer’s hardware
status and configuration.
109
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix E: Intel Manageability Command Tool-KVM
11. On the right side of the screen, select the Remote Control tab.
13. The Edit KVM Settings Form dialog box will appear. In the KVM State
field, click the scroll down arrow and then select Enabled - All Ports.
Click OK.
12. Under the KVM section, check whether the Remote KVM Setting’s
status is All Parts Enabled. If not, click the â arrow beside it.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
110
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix E: Intel Manageability Command Tool-KVM
14. The Remote KVM screen will appear. Select KVM Viewer Redirect
Port. The server will prompt you to enter the VNC’s password.
15. After the server entered the 6-character password provided by the
remote computer’s screen, the server will be able to see the remote
computer’s current image.
The remote iAMT’s computer will at the same time display the Intel
KVM Remote Assistance Application program’s 6-character password.
If you entered the wrong password thrice, a message will appear notifying you that the server and remote computer’s VNC
connection failed. You must click the KVM icon again and then
select KVM Viewer Redirect Port to reconnect.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
111
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Appendix F: PoE Device Setup
PoE Device Configuration
1. The system will automatically detect the PoE switch device (Realtek
RTL8139).
2. Connect the IP camera and then set its IP address.
Example:
IP CAM IP address:192.168.0.30
Fill out the PoE switch device’s
local IP address as 192.168.0.xx
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
112
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Wireless/LAN Bridge Configuration
1. Wireless LAN can be useful in many scenarios. Refer to the illustration
below on how to connect the PoE switch to the Internet.
wAN
2. Bridge the Intel LAN and PoE switch device. In the Network Connections dialog box, select the Local Area Connection devices and then
right click the selected devices. Select Bridge Connections.
ADSL connected to LAN1
192.168.0.2
Set PoE switch to bridge
with LAN1
192.168.0.3
192.168.0.4
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
113
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Hybrid DVR Configuration (NViS 3540H only)
Connect Surveillance Cameras
1. The 25-pin connector on the capture card is used to connect surveillance cameras.
2. Connect the D-sub end of the provided cable to the 25-pin connector
and the other ends to surveillance cameras.
25-pin
connector
Black BNC connector for TV out
Yellow BNC connector for CCVT
Red AV connector for Audio
D-sub end:
connect to the
25-pin connector
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
114
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
3. Set the IP address to 192.168.0.x.
Analog camera
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
4. Select the IP Camera Channel Setup.
IP camera
115
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
5. In the IP Camera Channel Setup dialog box, select 1.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
6. Select Preferences.
116
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
7. Select the Camera tab and then select the IP4 tab. Click Setting.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
8. Select the IP address and then click Add.
117
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
8. Enter the IP address:192.168.0.30 (default setting).
8. In the IP Camera field, select 192.168.0.30 MESSOA –NIC836(MPEG4).
Under Camera Model, select MESSOA – NIC836(MPEG4) and then click
OK.
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
118
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Appendix G: Voltage Low Shut-down Setting (NISKIG120)
Voltage Low Shut-down Setting (24V DC Input)
Voltage Low Shut-down Setting (12V DC Input)
SW1
DIP Switch 1
DIP Switch 2
Start-Up
Shut-Down
Note
SW1
DIP Switch 1
DIP Switch 2
Start-Up
Shut-Down
Note
00
0=OFF
0=OFF
11.5V
10.5V
Default
00
0=OFF
0=OFF
23V
21V
Default
01
0=OFF
1=ON
12V
11V
01
0=OFF
1=ON
24V
22V
10
1=ON
0=OFF
12.5V
11V
10
1=ON
0=OFF
25V
22V
11
1=ON
1=ON
12.5V
11.5V
11
1=ON
1=ON
25V
23V
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
119
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Appendix H: DC Input & Output Setting (NISKIG120)
DC Output Setting
DC Input Setting
SW1
DIP Switch 3
DIP Switch 4
Function Setting
Note
SW1
DIP Switch 7
DIP Switch 8
Function Setting
Note
00
0=OFF
0=OFF
12V DC input
Default
00
0=OFF
0=OFF
Disable
Default
01
0=OFF
1=ON
24V DC input
01
0=OFF
1=ON
24V Output
10
1=ON
0=OFF
Reserved only
10
1=ON
0=OFF
19V Output
11
1=ON
1=ON
9~36V Power module without Igni-
11
1=ON
1=ON
12V Output
tion function
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
120
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Appendix I: Power On/Off Delay Timer Setting (NISKIG120)
Delay Timer Setting
Power On Delay Timer
DIP Switch 3, 4, 5
SW2
DIP Switch 1
Function Setting
Note
0
0=OFF
Disable (default 3 seconds)
Default
1
1=ON
Enable (DIP Switch 3,4,5)
DIP Switch 6, 7, 8
POWER ON Delay Timer Select
Power Off Delay Timer
POWER OFF Delay Timer Select
000
10sec
000
20sec
100
30sec
100
1min
010
1min
010
5min
110
5min
110
10min
001
10min
001
30min
SW2
DIP Switch 2
Function Setting
Note
101
15min
101
1hour
0
0=OFF
Disable (default 0 second)
Default
011
30min
011
6hour
1
1=ON
Enable (DIP Switch 6,7,8)
111
1hour
111
18hour
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
121
NViS 3540/3540H/3540P4/3540P8 User Manual
Appendix F: PoE Device Setup
Appendix J: MCU Programming (NISKIG120)
J1
1
J1 : MCU programming port (RS232 signal)
J2
4 1 3
J2 : System port
1
GND
1
GND
2
COM TX (Output)
2
Power ON Button (Output)
3
COM RX (Input)
3
SLP_S3 IN (Input)
4
N/A
4
N/A
Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
122
NViS 3540/3540H/3540P4/3540P8 User Manual