Download user manual
Transcript
1.3.2 • • 1.3.3 Safety Appliances and Precautions The focus cannot be opened without tools; It must be excluded that the fans can be contacted with the hand. Therefore, air ducts must be connected to the focus. The minimum length of the pipelines is 900 mm. Used Symbols The following symbols are used in this manual: Caution, special note! Risk of: - injury of the user or the installer - damages to the device - impairment of the operation of the device if the instructions are not carried out properly 2 Notes for the User and the Installer This section describes how to handle focus. 2.1 2.1.1 Brief Description Limitations of Use The device is applicable for the ventilation in the living and office area (with restrictions in the industrial area) at air temperatures of -20°C to +40°C and normal air humidity. Any other type of use is considered as use for purposes other than intended. It is especially prohibited to use the device for the exhaustion of flammable and explosive gases. The installation is required in the frost-free area. For pre-heating of the outside air (in winter), an applicable plant-specific frost protection equipment should be connected upstream to the device. 2.1.2 Equipment Configuration The focus is designed and manufactured for controlled home ventilation. The focus 200 in the standard design has a patented reverse flow channel heat exchanger without moisture recovery. The device model focus (F) 200 is equipped with a membrane moisture heat exchanger. The compact ventilation device is designed for the wall fastening or on a mounting frame. The focus is delivered in the versions “RIGHT“ or “LEFT“. The design type is specified at the identification plate on the device. The housing consists of the coated sheet, the sidewalls in the colour anthracite, and the detachable hood in aluminium white. The internal lining made of high-quality polypropylene provides the necessary insulation and the device noise protection. 2.1.3 Heat Exchanger The highly efficient reverse flow channel heat exchanger (German and European patent) made of plastic is designed so that the exhaust air and supply air ducts are arranged in the chequer-board pattern and, therefore, a duplication of the heat exchange surface can be achieved towards the plate heat exchangers. With the moisture heat exchanger also humidity is transmitted besides the heat due to the chemical and physical properties of the heat exchanger membrane. The air types that flow past each other are divided for both types of heat exchangers. 2.1.4 Fans The focus includes two maintenance-free 230 VAC radial fans with the integrated power supply unit and electronic commutation. The volume flow constant fans keep the air quantity at a constant speed for each selected fan rotary speed. The air quantity is also not affected by soiled filters. 5