Vision introduces a new level of simplicty and flexibility to Security Control Systems. Vision’s advanced design gives Users and Installers greater utility and easier operation from their security system.
Please read this manual carefully to ensure that you receive the maximum benefit from Vision’s unique
features.
Vision has four factory-set programming templates built-in. For a quick and easy installation, pick the
programming template (Menu 0, Option 2) that most closely resembles your installation. Then program
the communicator and make whatever customizations are appropriate for your application.
Vision’s Quad Key is an excellent way to customize your system to meet your customer’s needs. In
Menu 3, Section 2, you can select Zone Type, Mode, or Area Arming of the system. This programming
area also allows you to activate Vision’s convenient Night By-Pass feature.
Vision can be programmed by using an LCD keypad, a field programmer, or a computer, using the
Remote Programming Utility (RPU) software with either a telephone connection or a direct connection
on-site (an INT module is required for direct connect).
Thank you for purchasing Vision. We’re committed to your Security and your Satisfaction.
Wiring Data - Terminal Block 2 (TB2)
Terminal #
1
2&3
4 (+) & 5 (-)
Description
Earth Ground
• You must use a minimum 18 gauge wire.
• Do not connect to chassis, electrical or telephone ground.
AC Input
Use 16.5VAC, 40VA Basler Electric BE116240CAA Class 2 transformer only.
Installation of incorrect transformer may undercharge battery.
Use only unswitched electrical outlet.
•
•
•
12VDC Bell Output
Connect 12VDC indicating devices to these terminals while observing polarity.
•
6, 7, 8, 9
Keypad Input
• A total of four keypads can be connected to the alarm system.
• You may mix LCD and LED keypads in the same installation.
• Terminal 6 Data (yellow wire)
• Terminal 7 Clock (green wire)
• Terminal 8 Ground (black wire)
• Terminal 9 Positive voltage (red wire)
• These terminals provide an output voltage of approximately 13.5VDC.
• Maximum keypad wire lengths:
AWG 18 AWG 20 AWG 22 – 2,000 feet