- 15 - -6Malfunction Boiler overheats Reason Too intensive combustion. Power outage (for systems with forced circulation). Power outage Boiler does not reach Bad, humid fuel. Poor draught. nominal output Bad fuel. Return watrer temperature Boiler “tears” is too low (>57°C !). Poor draught. Boiler overheats. Protection valve Overpressure in the malfunctions. boiler Expansion tank malfunctions. Removal Close air supply dampers, monitor boiler temperature. When temperature falls return to the regular firing. Call the electrician. During winter when the power is out for a prolonged period of time when there is a risk of system freezing down, drain the system. Use dry fuel, open up ignition damper. Check chimney draught. Use dry fuel. Adjust the mixing valve. Close air supply dampers, monitor boiler temperature. Check and replace in case of necessity protection valve and an expansion tank. 6. Safety precautions It is prohibited to: 3a fig. Boiler to chimney connection. * not less than 60° A - incorrect B – correct 3b fig. Chimney insert installation 3c fig. • Joints have to be well sealed; • Chimney hole has to be cleaned periodically. It is necessary to know that: • Smoke continues to cool in the chimney, vapor condenses on the chimney walls, especially in the unheated loft and on the outside of the building; • Condensate acids and erosion may destroy the chimney in few years; • Not cleaned soot in the chimney may self-combust and become the cause of fire. • Disassemble boiler or electric installation; • Connect boiler to the system without protection valve, that keeps pressure in the system below 0,15MPa (1,5 kgf/cm2); • Close hot or return water valves when boiler is operated; • Store dry fuels or other combustible materials close to or on top of the boiler; • Store fuel closer than 500 mm to boiler; • Ignition fuel with combustible liquids (petroleum, kerosene etc.); • Operate boiler with doors and covers open; • Allow children into the boiler room without adult supervision; • Operate boiler with electric heating devices without having it grounded; • Rapidly open loading doors during combustion (open a little, wait, then slowly open wide); Necessary to: • Monitor grounding efficiency. 7. Consumables Glazing gaskets, secondary air pipe, fire grate and cast iron doors, refractory bricks may all fail during operation. Consumables may be purchase from authorized distributors or the manufacturer of the boiler. KALVIS – 5..., KALVIS – 5...W EN 2009.05.18