Download EMC TEST REPORT
Transcript
PEP Testing Laboratory 12-3Fl, No. 27-1, Lane 169, Kang-Ning St., Hsi-Chih, Taipei Hsien, Taiwan, R. O. C. TEL: 886-2-26922097 FAX: 886-2-26956236 REPORT NO. : E940698 8.5 Radiated Disturbance Test Data Model No. : UC232R Frequency range : 30MHz to 1GHz Temperature : 33 o C Antenna polarization : Over Freq. (MHz) Level Limit (dBuV/m) (dB) 110.780 131.007 150.131 170.311 209.036 327.780 21.99 20.42 22.24 22.45 20.06 19.93 -8.01 -9.58 -7.76 -7.55 -9.94 -17.07 Limit Detector Humidity HORIZONTAL ; Read 29.62 26.70 26.04 27.73 28.05 25.03 Test distance : Antenna Cable Line Level Factor (dBuV/m) (dBuV) (dB) 30.00 30.00 30.00 30.00 30.00 37.00 : Quasi-Peak Value : 61 % 11.86 13.08 15.40 13.85 10.81 13.30 Loss (dB) 0.81 0.94 1.10 1.17 1.40 1.79 Preamp Factor (dB) Azimuth (̓angle) Antenna High(m) 20.30 20.30 20.30 20.30 20.20 20.19 283.0 195.0 244.0 304.0 274.0 185.0 4.0 4.0 4.0 3.9 3.7 3.4 ! ! ! ! Note : 1. 2. Level = Read Level + Antenna Factor + Cable Loss – Preamp Factor Over Limit = Level – Limit Line Page 21 of 79 10m ;