Download aero 50 - DAS Audio

Transcript
A50rack user´s guide
Amplification Racks for
aero 50 systems
Introduction
Presets
Array correction
Configurations
Accessories
Ease Focus simulations
www.dasaudio.com
Safety Precautions
A50rack
Keep these instructions. Read them carefully.
Heed all warnings. Follow all instructions.
The exclamation point within an equilateral triangle is intended to alert the user of important operating and
maintenance instructions in the literature accompanying the appliance.
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the product´s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
Do not use this apparatus near water.
Do not expose this devices to rain or moisture.
Do not place any objects containing liquids such a bottles or glasses on top of the unit.
Clean only with a dry cloth.
Class I device.
A50racks require Class 2 ouput wiring.
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce
heat.
Do not block ventilation openings. Install in accordance with the manufacturer´s instructions.
Take into account that the nominal AC voltage is the value shown in the equipment +-10% (according to
IEC60065:2001).
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles and the
point where they exit from the apparatus.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged
in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been
dropped.
TO PREVENT ELECTRIC SHOCK, DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER
SERVICEABLE PARTS INSIDE. REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRONIC SHOCK DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.
THE MAINS PLUG OF THE POWER SUPPLY CORD SHALL RAMAIN READLY ACCESSIBLE.
TO COMPLETELY DISCONNECT THIS EQUIPMENT FROM THE AC MAINS, DISCONNECT THE POWER
SUPPLY CORD PLUG FROM THE AC RECEPTACLE.
In order to avoid noise or hum, and protect the input/output stage of the systems electronics from serious
damage, proper grounding connections of all the components of the system are required. Connect the
components making sure that AC line polarity is maintained, and that all grounds are connected to a common
grounding point using the same gauge cable as the neutral and line cables.
D.A.S. recommends that before powering up any D.A.S. system, test the mains making sure that the voltage
potential difference between the neutral and ground does not exceed 5 VAC.
Introduction
The A50rack is a rugged touring rack that includes
power amplifiers, processors, power distro, input
patch panel and output patch panel for the aero 50
line array systems.
There are two different options for the A50rack.
Option1 (A50rack_1) is assembled with 3 x DAS
Audio D-100 four channel amps and a DAS Audio
DSP-2060A.
The D-100 amplifier is a 4 channel class D
switching power supply amplifier of 2800W per
channel.
In Rack Option 2 (A50rack_2) comprised by 6 x
PowerSoft K-6DSP AESOP amplifiers.
The K-6 DSP includes its own DSP and is a class D
switching power supply 2 channel amp. Power per
channel is 3600W@2ohm.
Input patch panels have 2 or 3 (depending on the
option) input connectors to create separated zones
in the array.
In rack option 1 the output panel of the rack is
always composed of three Speakon NL 8
connectors which will power up to two aero 50 each
one working at 4ohm and up to 4 aero 50 (2ohm
load) in the powersoft case, in rack option 2.
The aero 50 is a three way large format line array
system to be used for live sound applications.
Two 15” loudspeakers with neodymium magnet
assemblies reproduce the Low Frequency range.
Four 8” loudspeakers with neodymium magnet
assemblies reproduce the Mid Frequency range.
Two 3” coil neodymium compression drivers with
1.5” exit reproduce the High Frequency range.
The system has been designed to have a nominal
Horizontal coverage of 90º. In the coupling plane
(vertical) the coverage depends on the frequency
and the splay angles between cabinets, as it is a
true line array system.
To ensure the performance of the system and the
uniformity of the horizontal and vertical dispersion
X-over points must not be changed.
A family of locked presets is provided for different
DSP platforms; DAS DSP-2060A and 4080 and
Lake LM-26 / PLM / K-6 amplifiers.
DAS Audio offers racks with amplifiers and
processors. The processors in the racks adjust the
levels between the ways (LF, MF, HF), the
crossover points, delays and Eqs. These settings
must remain without any variation to ensure the
optimal acoustical performance of the system. (this
is the main reason why they are locked).
Besides basic parametres, inside the processors
clip and rms limiters are set up.
The system´s reliability and dynamic range are
determined by the rms and clip limiter thresholds.
Don´t vary them.
A50 rack
ANALOG AMPS 1&2
IN
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
-2
-2
OUT
PROFESSIONAL
POWER
AMPLIFIER
-4
-2
-2
0
Ch. B
Link
IN
-12
0
Ch. A
Atten. dB
-6
-4
-12
0
OCM
Atten. dB
-6
-4
-12
ANALOG AMPS 5&6
OUT
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
-4
IN
PRC D
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
ANALOG AMPS 3&4
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
OUT
0
Ch. C
Link
Ch. D
Link
AMP1
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
-4
-12
-12
-2
-2
0
-2
0
Ch. B
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten. dB
-6
-4
-12
-2
0
OCM
Atten. dB
-6
-4
-12
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
-4
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
0
Ch. C
Link
Ch. D
Link
AMP2
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
-4
-12
-2
0
Ch. B
-2
0
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten. dB
-6
-4
-12
-2
0
OCM
Atten. dB
-6
-4
-12
-2
Link
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
-4
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
Ch. C
FI-Schalter
0
Link
FI40 30mA 4pol.
Ch. D
AMP3
L1
L2
L3
I
o
power distro
FI-Schalter
FI40 30mA 4pol.
A50rack_1
L1
L2
L3
I
o
A50rack_2
A50rack - 3
The presets
The family of presets available for the three main
different platforms (DAS DSP-2060A/4080,
PowerSoft K-6, Lake Lm26 / PLM) is based on a flat
frequency response of a single aero 50 cabinet. For
updates check the DAS Audio website (aero 50
related downloads).
www.dasaudio.com/en/p/aero-50-2/
Type B: to be used at the FOH DSP-4080
processor. The preset will compensate the array effect
and the number of cabinets used.
These presets will be named as follows:
A50Vx.y 8U
A50Vx.y 10U
A50Vx.y 12U
For instance:
A50V52 16U
preset version
Number of Units
For DAS DSP-2060A and 4080 the presets are
available in AudioCore .xaa format.
http://www.dasaudio.com/DOCUMENTOS_D/SOFT
WARE/AUDIOCORE_V871.ZIP
For the Powersoft K-6 DSP amplifiers presets are
available in Armonia format.
http://www.powersoftaudio.com/en/support/armonia-supportforum.html
For the Lake LM26 /PLM amplifiers, presets are
available in .csm lake format.
http://labgruppen.com/support/software_firmware/
Different High Pass X-overs for the LF are
provided; (a) 45Hz to be used as a full range
system without subs, and (b) with cut at 80Hz to be
used with LX-218C (or CA) subs.
Besides the High Pass X-overs presets are
available for long (LT), mid (MT)and short throw
(ST) zones in the array. To achieve a uniform sound
pressure level across the distance and optimal
acoustical performance a line array system has to
be managed in groups of cabinets with different
presets. For instance the four bottom cabinets
should have to be treated as the downfill or short
throw of the system.
There will be two different types of presets:
Type A: presets to be used in the rack processors
to define all the settings in one cabinet.
Presets for all these platforms: DSP-2060A, LM26
and K6DSP.
Presets will be named as follows:
A50Vx.y LT
A50Vx.y MT
A50Vx.y ST
For instance: A50V5.4 ST
preset version
Long, Mid or Short Throw
A50rack - 4
The Rack presets - type A
DAS DSP-2060A
Presets(loaded in the processors) will be named as follows:
A50Vxy LT+MT (input A for LT, input B for MT)
Long Throw
A50Vxy MT+MT
A50Vxy MT+ST
A50Vxy LT+ST
Mid Throw
Mid Throw
Mid Throw
Mid Throw
Long Throw
Short Throw
Short Throw
- To recall a memory or a preset using the front panel:
press menu -->enter--> global memory-->enter-->recall a memory->enter-->Crossover-->enter and select the desired one.
All the previous listed presets or memories on the DSP-2060A are
X-over type.
- When the DSP is connected to a computer using AudioCore
software, to recall a memory (once the communication between
DSP and computer has been stablished) just do right click on the
DSP main window:
- When the DSP is connected to the computer but is
not including factory presets just connect the unit to
the computer and open the desired audioCore file. For
example open A50V55 LT+MT.xaa
Next step, click On Line and send Settings to the unit.
Once the unit (DSP) has the preset loaded the user
can store it via software or via front panel.
Example: a system with 12 aero 50 per side with 3
different signal groups would be configured as
follows:
LT
LT
LT
LT
MT
MT
MT
MT
ST
ST
ST
ST
Long Throw
Short Throw
preset: A50Vxy LT+MT
Mid Throw
Short Throw
preset: A50Vxy MT+ST
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
Bridge A-B
-4
Power
PRC D
-24 -12 -6 -3 Limit
OCM
-4
-12
-2
-2
0
0
Ch. C
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
Link
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. A
Bridge C-D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. D
Link
PRC C
PRC B
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-12
-2
0
Ch. C
Link
A/P
PRC A
Atten . dB
-6
-4
-12
-2
0
Ch. B
PROFESSIONAL
POWER
AMPLIFIER
OCM
Atten . dB
-6
-4
-12
-2
Link
-24 -12 -6 -3 Limit
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
AMP1
Ch. D
Link
AMP1
Bridge A-B
A/P
Power
Bridge C-D
Bridge A-B
A/P
Power
Bridge C-D
PRC A
PRC B
PRC C
PRC D
PRC A
PRC B
PRC C
PRC D
-24 -12 -6 -3 Limit
-24 -12 -6 -3 Limit
OCM
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-24 -12 -6 -3 Limit
-4
-24 -12 -6 -3 Limit
OCM
-24 -12 -6 -3 Limit
-4
-12
-2
-2
0
0
Ch. C
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
Link
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. A
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. D
Link
OCM
Atten . dB
-6
-12
-2
0
Ch. C
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
Link
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. A
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
AMP2
Ch. D
Link
AMP2
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
Bridge A-B
Ch. C
Power
Ch. B
-4
-12
-2
-2
0
Link
PROFESSIONAL
POWER
AMPLIFIER
OCM
Atten . dB
-6
-4
-12
-2
0
Link
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
-2
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. D
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-12
-2
0
Link
A/P
PRC A
-24 -12 -6 -3 Limit
-4
-12
-2
0
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
OCM
Atten . dB
-6
-4
-12
-2
Link
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
AMP3
Ch. C
0
Link
Ch. D
AMP3
power distro
FI-Schalter
FI4030mA 4pol.
L1
I
o
L2
L3
power distro
FI-Schalter
FI4030mA 4pol.
L1
L2
L3
I
o
A50rack - 5
LM-26 Modules will be named as follows:
A50Vx.y LT
A50Vx.y MT
A50Vx.y ST
Frame presets will be named as:
A50Vx.y LT-MT (in A for LT, in B for MT)
A50Vx.y MT-MT
A50Vx.y MT-ST
A50Vx.y LT-ST
Mid Throw
Long Throw
Mid Throw
Mid Throw
Short Throw
Mid Throw
Short Throw
Long Throw
- To recall a frame preset using the front panel go to menu--> enter--> frame preset --> enter --> select the memory
A50x.y MT-ST -->recall
- To load a module (csm format) in the DSP using the Lake Controller software:
Go to Module Menu--> select recall a module
Select the desired module on module A (LT/MT/ST)--> recall --> Repeat the same procedure on Module B
- Once the two modules have been recalled (in this case LT and MT) the user should store them in the processor as
system presets. To do it go to System Store / Recall folder --> System presets --> tap on both modules--> store with
new name: A50V5.5 LT -MT
A50rack - 6
Example: a system with 12 aero 50 per side with 3
different signal groups would be configured as
follows:
LT
LT
LT
LT
MT
MT
MT
MT
ST
ST
ST
ST
preset: A50Vxy LT+MT
Mid Throw
Long Throw
Short Throw
Mid Throw
preset: A50Vxy MT+ST
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
Bridge A-B
-4
Power
PRC D
-24 -12 -6 -3 Limit
OCM
-4
-12
-2
-2
0
0
Ch. C
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
Link
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. A
Bridge C-D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. D
Link
PRC C
PRC B
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-12
-2
0
Ch. C
Link
A/P
PRC A
Atten . dB
-6
-4
-12
-2
0
Ch. B
PROFESSIONAL
POWER
AMPLIFIER
OCM
Atten . dB
-6
-4
-12
-2
Link
-24 -12 -6 -3 Limit
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
AMP1
Ch. D
Link
AMP1
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
Bridge A-B
-4
Power
PRC D
-24 -12 -6 -3 Limit
OCM
-4
-12
-2
-2
0
0
Ch. C
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
Link
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. A
Bridge C-D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
-2
0
Ch. D
Link
PRC C
PRC B
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-12
-2
0
Ch. C
Link
A/P
PRC A
Atten . dB
-6
-4
-12
-2
0
Ch. B
PROFESSIONAL
POWER
AMPLIFIER
OCM
Atten . dB
-6
-4
-12
-2
Link
-24 -12 -6 -3 Limit
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
AMP2
Ch. D
Link
AMP2
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
Bridge A-B
Ch. C
Power
Ch. B
-4
-12
-2
-2
0
Link
PROFESSIONAL
POWER
AMPLIFIER
OCM
Atten . dB
-6
-4
-12
-2
0
Link
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
-12
-2
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. D
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-12
-2
0
Link
A/P
PRC A
-24 -12 -6 -3 Limit
-4
-12
-2
0
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten . dB
-6
-4
-12
-2
0
Ch. B
OCM
Atten . dB
-6
-4
-12
-2
Link
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
-4
0
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten . dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
AMP3
Ch. C
0
Link
Ch. D
AMP3
power distro
FI-Schalter
FI4030mA 4pol.
L1
I
o
L2
L3
power distro
FI-Schalter
FI4030mA 4pol.
L1
L2
L3
I
o
A50rack - 7
K-6 DSP amplifiers, presets will be named as follows:
A50Vx.y Low -Low
A50Vx.y Mid-High MT
A50Vx.y Mid-High LT
A50Vx.y Mid-High ST
Due to the configuration of the power supply of the amps, Powersoft warns that
both output channels must have a close to identical charge at output stage, since
unbalanced charge will cause problems of excessive temperature rise. We
recommend to follow next arrangement to the amplifier racks and cabling.
Each pack of 2 K6 DSP (LOW-LOW-MID-HIGH) is able to manage up to
4 Aero50 creating a 2 Ohm load configuration.
Since Armonía version 2.3.1, we are able to upload a preset directly from the software by right clicking on the desired amp.
This could be faster but it will not save the preset into the DSP memories.
In order to be able of changing between different types of throws provided by DAS Aero50v5.5 Presets, we recommend the
use of the PRESET MANAGER tab in armonía (A), using the PLST file (B) you can “broadcast” the whole preset family for
all connected amps by one single click (C).
WARNING: Make sure you have muted or unplugged the whole system speakers before doing this, since after spreading
all presets the amps will take number 1 to use, being this one the LOW-LOW this can cause serious damage to high drivers.
A50rack - 8
After armonía loads all presets (this can take a while) you can load the desired preset on each amplifier by doing right
click on it and selecting from “Preset-->Recall” or either disconnect from the Net, and recall desired preset form the
front panel of each Amplifier by “Local Presets” menu.
A50rack - 9
The array correction
Type B presets: to be used at the FOH DSP-4080
With the DSP presets provided the frequency
response of one single cabinet is flat.
DAS Audio SA
LogChirp - Frequency Response
09-05-2012 16.47.53
120.0
dBSPL
110.0
100.0
The preset will correct the array effect and the number of
cabinets used.
These presets will be named as follows:
A50Vx.y 8U
A50Vx.y 10U
A50Vx.y 12U
For instance:
90.0
A50V52 16U
preset version
80.0
70.0
20
CH A
50
dBSPL
1/12 Octave
100
192kHz
200
131K
Rectangular
500
Start 0.00ms
1k
2k
Stop 682.66ms
Hz
5k
FreqLO 1.46Hz
10k
20k
Length 682.66ms
File: PLMV5.2 A 1m corte a 80Hz.mls
Graph shown corresponds to 1 aero 50 measured
at 3m in an indoor room (1/12 octave resolution):
Number of Units
The array correction
DSP
Number of units
EQs
DSP-2060A / 4080
16 units
f =2k57Hz Q=0.59 Gain -8.5dB Low Shelf
f =595Hz Q=20 Gain -3dB Bell
14 units
f =2k57Hz Q=0.59 Gain -7dB Low Shelf
f =595Hz Q=20 Gain -3dB Bell
When coupling or adding more systems the low
and mid ranges couple much more than the high
frequency one. See the the graph below ( 1 aero 50
vs 3 aero 50):
12 units
f =2k57Hz Q=0.59 Gain -6dB Low Shelf
f =595Hz Q=20 Gain -3dB Bell
10 units
f =2k57Hz Q=0.59 Gain -4.4dB Low Shelf
f =595Hz Q=20 Gain -3dB Bell
3 aero 50
8 units
f =2k57Hz Q=0.59 Gain -2.5dB Low Shelf
f =595Hz Q=20 Gain -3dB Bell
1 aero 50
The use of a DSP-4080 at FOH is mandatory to
correct this effect (low an mid range coupling) and
to have different sends to the PA (long throw, mid
throw, short throw) or to other systems (Ffill, subs
etc) as well as to properly time align all of them.
In the graph shown below different array
corrections for different number of aero 50 cabinets
(1/24 octave resolution).
No array correction
Low Shelving -3dB
Low Shelving -6dB
Low Shelving -8dB
Low Shelving filters with different gain values.
See below the electrical curve of the array correction
on the processor for 12 aero 50 units:
A50rack - 10
A50rack_1: 6 x aero50 at 4 ohms
AMPLIFIERS: DAS D-100 or FP10000Q rack (10U rack)
Each rack includes: 1 x DSP-2060A + 3 x D100 (or 3 x FP10000Q) +
1 x power distro 32A in/out
2 independent input signals
Rs485 in/out to be used with audioCore.
Amplifier Gain: 36dB; for DAS D series
Peak limiters D100: LF 0dB, MF 0dB, HF -2dB
Amplifier Gain: 35dB; for FP series from LABGruppen
Peak limiters FP10000Q: LF 121V, MF 121V, HF 101V
DSP input B
Speaker outs: 3 x Speakon 8 for 6 x aero50
these 2 amps use the same signal (input A)
DSP input A
A50 rack
ANALOG AMPS 1&2
IN
Bridge A-B
A/P
Power
Bridge C-D
PRC A
PRC B
PRC C
PRC D
-24 -12 -6 -3 Limit
-24 -12 -6 -3 Limit
OCM
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
IN
OUT
-4
-12
-2
-2
0
0
Ch. C
Link
audioCore
OUT
PROFESSIONAL
POWER
AMPLIFIER
Atten. dB
-6
-4
-12
-2
0
Ch. B
Link
OCM
Atten. dB
-6
-4
-12
-2
0
Ch. A
IN
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
-4
-12
ANALOG AMP 3
OUT
Ch. D
Link
AMP1
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
-4
-4
-12
-12
-2
-2
0
-2
0
Ch. B
Link
0
Ch. C
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten. dB
-6
-4
-12
-2
0
OCM
Atten. dB
-6
-4
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
-12
Ch. D
Link
AMP2
Bridge A-B
Power
A/P
PRC A
-24 -12 -6 -3 Limit
OCM
-4
-12
-12
-2
-2
0
Link
Ch. B
-2
0
Link
PROFESSIONAL
POWER
AMPLIFIER
Atten. dB
-6
-4
-12
-2
0
OCM
Atten. dB
-6
-4
-12
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
-4
Ch. A
PRC D
-24 -12 -6 -3 Limit
OCM
Atten. dB
-6
Bridge C-D
PRC C
PRC B
-24 -12 -6 -3 Limit
Ch. C
0
Link
Ch. D
AMP3
A50 rack
+1 /-1 AMP1 Ch1
+2 /-2 AMP1 Ch2
+3 /-3 AMP1 Ch3
+4 /-4 AMP1 Ch4
+1 /-1 AMP2 Ch1
+2 /-2 AMP2 Ch2
+3 /-3 AMP2 Ch3
+4 /-4 AMP2 Ch4
OUT 1
power distro
FI-Schalter
FI40 30mA 4pol.
L1
L2
+1 /-1 AMP3 Ch1
+2 /-2 AMP3 Ch2
+3 /-3 AMP3 Ch3
+4 /-4 AMP3 Ch4
OUT 2
OUT 3
L3
I
o
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
16A 230V
this amp uses signal (input B)
Presets available on the DSP-2060A:
A50Vxy LT+MT
A50Vxy MT+MT
A50Vxy MT+ST
A50Vxy LT+ST
A50rack - 11
A presets: A50Vx.y LT-ST
-12
-12
PROFESSIONAL
POWER
AMPLIFIER
MIXER_1
-12
-12
-12
0
-4
OCM
-2
Link
-4
-2
OCM
Link
-4
-2
OCM
-12
Atten. dB
-6
Ch. D
PRC D
Bridge C-D
Atten. dB
-6
PRC D
0
0
Atten. dB
-6
-4
-2
OCM
-4
-4
-2
OCM
-2
OCM
-24 -12 -6 -3 Limit
Ch. D
Bridge C-D
-24 -12 -6 -3 Limit
0
PROFESSIONAL
POWER
AMPLIFIER
-12
Atten. dB
-6
0
Atten. dB
-6
Atten. dB
-6
-4
-2
-2
Link
-4
OCM
Link
-4
OCM
Link
-2
OCM
-24 -12 -6 -3 Limit
Ch. A
PRC A
Bridge A-B
0
-24 -12 -6 -3 Limit
Ch. A
PRC A
Bridge A-B
0
-24 -12 -6 -3 Limit
Ch. A
-12
Atten. dB
-6
0
Atten. dB
-6
Atten. dB
-6
-4
-2
-2
Link
-4
OCM
Link
-4
OCM
Link
-2
OCM
-24 -12 -6 -3 Limit
Ch. B
A/P
PRC B
0
-24 -12 -6 -3 Limit
Ch. B
A/P
PRC B
0
-24 -12 -6 -3 Limit
Ch. B
-12
Atten. dB
-6
0
-4
-2
-2
Link
-4
OCM
Link
-4
OCM
Link
-2
OCM
-24 -12 -6 -3 Limit
PRC C
Power
Ch. C
Atten. dB
-6
0
-24 -12 -6 -3 Limit
PRC C
Power
Ch. C
Atten. dB
-6
0
-24 -12 -6 -3 Limit
Ch. C
-12
Atten. dB
-6
PRC D
0
Atten. dB
-6
Atten. dB
-6
-4
-4
-4
-2
OCM
-2
OCM
-2
OCM
-24 -12 -6 -3 Limit
Ch. D
Bridge C-D
PRC D
0
-24 -12 -6 -3 Limit
Ch. D
Bridge C-D
0
-24 -12 -6 -3 Limit
Ch. D
FI40 30mA 4pol.
power distro
FI-Schalter
o
I
L1
L2
MIXER_2
SUBS
FOH DSP4080
IN - A audio - OUT
L3
PROFESSIONAL
POWER
AMPLIFIER
PROFESSIONAL
POWER
AMPLIFIER
PROFESSIONAL
POWER
AMPLIFIER
A presets: A50Vx.y MT-ST
B presets: A50x.y 12U
-12
PRC D
Atten. dB
-6
PRC C
Power
Ch. C
Atten. dB
-6
0
-24 -12 -6 -3 Limit
PRC C
Power
Ch. C
Atten. dB
-6
-24 -12 -6 -3 Limit
-24 -12 -6 -3 Limit
Bridge C-D
-12
Power
-12
-24 -12 -6 -3 Limit
PRC C
-12
A/P
-2
-2
Ch. D
-12
PRC B
-4
OCM
-2
Link
-4
OCM
Link
-4
OCM
Link
-12
PRC A
Atten. dB
-6
Atten. dB
-6
0
-12
Bridge A-B
Atten. dB
-6
0
-24 -12 -6 -3 Limit
Ch. B
A/P
PRC B
0
-24 -12 -6 -3 Limit
Ch. B
A/P
PRC B
-24 -12 -6 -3 Limit
Ch. C
L3
-12
PRC D
-12
Link
PROFESSIONAL
POWER
AMPLIFIER
Bridge C-D
-2
-2
0
-12
Power
-4
OCM
-2
Link
-4
OCM
Link
-4
OCM
Ch. B
-12
PRC C
Atten. dB
-6
Atten. dB
-6
Atten. dB
-6
Link
-12
A/P
L2
PRC B
-12
L1
PRC A
I
o
Bridge A-B
0
-24 -12 -6 -3 Limit
Ch. A
PRC A
Bridge A-B
0
-24 -12 -6 -3 Limit
Ch. A
PRC A
Bridge A-B
0
-24 -12 -6 -3 Limit
Ch. A
FI40 30mA 4pol.
power distro
-12
FI-Schalter
Sample: 12 aero 50 + 12 LX-218C
LONG THROW
LONG THROW
LONG THROW
LONG THROW
MID THROW
MID THROW
MID THROW
MID THROW
SHORT THROW
SHORT THROW
SHORT THROW
SHORT THROW
SUB
SUB
Presets to be used:
At the FOH DSP-4080 processor use A50Vx.y 12U
At the amplifier´s processors use A50Vx.y LT for long throw;
A50x.y.z MT for mid throw and A50x.y ST for short throw
-2
Atten. dB
-6
0
-4
-2
OCM
Link
OCM
-2
Link
-4
-12
0
-2
Link
-4
OCM
Ch. C
Atten. dB
-6
0
-2
Link
-4
OCM
Atten. dB
-6
Ch. D
0
0
-4
Ch. D
Atten. dB
-6
0
-2
OCM
-4
-4
-2
OCM
-2
OCM
-24 -12 -6 -3 Limit
PRC D
Bridge C-D
Ch. D
Atten. dB
-6
-24 -12 -6 -3 Limit
PRC D
-4
OCM
PRC C
Power
Ch. C
Atten. dB
-6
0
-24 -12 -6 -3 Limit
Ch. C
-12
Bridge C-D
0
Link
OCM
-24 -12 -6 -3 Limit
Power
Atten. dB
-6
Atten. dB
-6
-2
Link
-4
-12
PRC C
-2
-24 -12 -6 -3 Limit
A/P
-4
OCM
-12
PRC B
0
Ch. B
A/P
PRC B
0
-24 -12 -6 -3 Limit
Ch. B
-12
PRC A
Atten. dB
-6
Link
OCM
-12
Bridge A-B
-24 -12 -6 -3 Limit
Atten. dB
-6
-2
Link
-4
Ch. B
Atten. dB
-6
o
I
L1
shelf eq: array
correction
-12
Ch. A
PRC A
Bridge A-B
0
-24 -12 -6 -3 Limit
Ch. A
PRC D
-2
Link
-4
OCM
-24 -12 -6 -3 Limit
Bridge C-D
-12
Power
0
-24 -12 -6 -3 Limit
PRC C
-12
A/P
Ch. A
Atten. dB
-6
-24 -12 -6 -3 Limit
PRC B
-12
PRC A
Bridge A-B
-24 -12 -6 -3 Limit
FI40 30mA 4pol.
L2
L3
PROFESSIONAL
POWER
AMPLIFIER
PROFESSIONAL
POWER
AMPLIFIER
PROFESSIONAL
POWER
AMPLIFIER
DSP to send different signals per groups
and correct the low / mid coupling of the
line arrays:
SUB
-12
-12
FI-Schalter
power distro
A50rack - 12
A50rack_2: 12 x aero50 at 2 ohms
AMPLIFIERS: Powersoft K-6DSP AES (10U rack)
Each rack includes: 6 x K-6DSP+AESOP (DSP included in the amplifiers) +
1 x power distro 32A in
3 independent input signals
Speaker outs: 3 x Speakon 8 for 12 x aero50
Remote monitoring with Armonía Software (CAT5 cable)
these 2 amps use the same signal
these 2 amps use the same signal
these 2 amps use the same signal
A50 rack
ANALOG AMPS 1&2
IN
OUT
ANALOG AMPS 3&4
IN
ANALOG AMPS 5&6
OUT
IN
OUT
signal 1
signal 2
signal 2
signal 3
FI-Schalter
FI40 30mA 4pol.
L1
I
o
L2
L3
A50 rack
+1 /-1 AMP1 Ch1
+2 /-2 AMP1 Ch2
+3 /-3 AMP1 Ch3
+4 /-4 AMP1 Ch4
OUT 1
INDU-ELECTRIC
16A 230V
+1 /-1 AMP2 Ch1
+2 /-2 AMP2 Ch2
+3 /-3 AMP2 Ch3
+4 /-4 AMP2 Ch4
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
OUT16A
2 230V
+1 /-1 AMP3 Ch1
+2 /-2 AMP3 Ch2
+3 /-3 AMP3 Ch3
+4 /-4 AMP3 Ch4
INDU-ELECTRIC
16A 230V
INDU-ELECTRIC
16A 230V
OUT 3
INDU-ELECTRIC
16A 230V
A50rack - 13
MIXER_2
Sample: 12 aero 50 + 12 LX-218C
MIXER_1
DSP-4080
Presets to be used:
L3
At the FOH DSP-4080 processor use A50Vx.y 12U
At the amplifier´s processors use A50Vx.y LT for long throw;
A50x.y.z MT for mid throw and A50x.y ST for short throw
A50 rack
L2
LONG THROW
LONG THROW
LONG THROW
LONG THROW
MID THROW
MID THROW
MID THROW
MID THROW
A50 rack
FI40 30mA 4pol.
FI-Schalter
SHORT THROW
SHORT THROW
L1
A50Vx.y Low-Low
A50Vx.y Mid-High LT
o
SHORT THROW
FI40 30mA 4pol.
A50Vx.y Low-Low
A50Vx.y Mid-High MT
I
SUBS
SHORT THROW
FI-Schalter
SUB
A50Vx.y Low-Low
A50Vx.y Mid-High ST
B presets: A50Vx.y 12U
FOH DSP4080
IN - A audio - OUT
shelf eq: array
correction
DSP to send different signals per groups
and correct the low / mid coupling of the
line arrays:
SUB
SUB
I
o
L1
L2
L3
A50rack - 14
Accessories
Speaker cabling
SpkC1 (4 pair 2.5mm2 Speaker cable, 2 x NL8, 1m length)
SpkC20 (pair 2.5mm2 Speaker cable, 2 x NL8, 20m length)
SpkC25 (4 pair 2.5mm2 Speaker cable, 2 x NL8, 25m length)
Note: 25m length valid for 12 to 16 aero 50 per side
20m length valid for 8 to 10 aero 50 per side
Rigging frames
AX-aero50 (one pick up bar + 2 moving side panels)
Weight: 51kg (112.2 lb)
Up to 8 cabinets
For more than 8 cabinets an additional pick up bar must be used
AX-combo12 suspend aero 12A
underneath aero 50
Weight: 19.6kg (43 lb)
19” Power Distros
power distro
FI-Schalter
FI40 30mA 4pol.
FI-Schalter
FI40 30mA 4pol.
L1
I
o
Signal Cables
L1
L2
I
o
L2
L3
L3
A50_ Distro1 (32A 400V 5P in / out + circuit breakers +
LED per phase+ 6 x 16A Schuko)
To be used in racks type 1: D-100 or FP-10000Q amps
A50_ Distro2 (32A 400V 5P in + circuit breakers +
LED per phase+ 6 x cetak 16A)
To be used in racks type 2: K-6 DSP+AESOP amps
SC_05 balanced microphone cable 0.5m length
SC_1 balanced microphone cable 1m length
SC_2 balanced microphone cable 2m length
SC_5 balanced microphone cable 5m length
SC_10 balanced microphone cable 10m length
SC_25 balanced microphone cable 20m length
A50rack - 15
Touring Rack: Rack-T_10U
Weight: 56kg with D-100 amps; 92kg with k-6 amps (184lbs) - 56kg with FP-10000Q
Dimensions:
HxWxD: 70.1 x 58.2 x 87.3cm
873mm
701mm
582mm
Shockproof professional touring rack
9mm birch plywood
High quality hardware
Front/Rear rack profiles (465mm)
100mm Caster wheels rated at a weight limit of 160kg each
20mm high density foam
Front and rear captive doors
Covers
FUN-aero50 is a protective nylon cover for 1 aero 50
FUN-2-LX218C is a protective nylon cover for a stack of 2 LX-218C
FUN-3-LX218C nylon cover for a stack of 3 LX-218C
Dollies
PL-50
The PL-50 dolly is included with
each aero 50 cabinet. It is used to
transport and fly the system.
PL-218C
The PL-218C dolly is used to
transport stacks of 2 or 3 LX-218C.
A50rack - 16
8 x aero 50 @ 50m; pick point height
7.7m
A50rack - 17
10 x aero 50 @ 60m; pick point height
9.2m
A50rack - 18
12 x aero 50 @ 75m; pick point height
10.2m
A50rack - 19