3.2. TECHNICAL DATA
Voltage:
110, 220 or 240 V A.C. (according customer's requirement), 50/60 Hz
Board diameters:
325 x 133 x 55 mm
Protective relay:
1 relay (RL 20), which switches off all outlets of the control system in the case of
Output:
19 relay outputs with a switching capacity up to 240 V A.C.,2 A
Input:
8 optically insulated inputs, 12 D.C.
Analog inputs:
2 analog inputs - one for a temperature sensor, the second one for a pressure
sensor of water level measuring.
MACHINES WITH A FREQUENCY CONTROL:
THE SERIAL PORT IS EQUIPPED FOR THE FREQUENCY INVERTOR
CONTROLLING.
Microprocessor:
NEC D78CP18CW
Memory:
1 k byte static RAM and 32 k byte PROM to D 78 CP18 CW
Display:
LCD with 32 symbols, LED illuminated background; the height of symbols 8,5 mm
Languages:
Display messages can be performed in four different languages: English, French,
German and Dutch - according customer's order.
Software
contains pre-set wash programmes, all texts from programming and operation
modes in four languages; works in 3 modes:
1. INITIALIZATION MODE - only for qualified workers! (details in paragraph 8.6.)
Programmer switch SW 1 is switched to 0-9 for a given machine, the programmer must be initialized for a
given machine type only once (details in chapter 4.)
2. PROGRAMMING MODE
After initialization, a program pre-selection, composition or change of washing can be realized (details in
chapter 5.).
3. OPERATION MODE
After initialization, the machine can be used.
6
PROGRAMMING MANUAL
503 838 PUB DATE 04/99