5. Technical data
Dimensions W x H x D
38 mm x 110 mm x 79 mm (MM2-...)
38 mm x 110 mm x 119 mm (MM3-..., MM4-...)
38 mm x 110 mm x 79 bzw. 119 mm (MM20-..., MM21-..., MM22-..., MM23-..., MM30-..., MM33-...)
Humidity
Atmospheric pressure
Pollution degree
Laser protection
Protection type
EMV interference proof
EN 61000-4-2, Discharge of static electricity
10% to 95% (non condensing)
up to 2000 m (795 hPa, higher altitudes on demand)
2
Class 1 conforming to EN 60825-1: 2007
IP 20
A 1)
Contact discharge: test level 3
4 kV
Air discharge: test level 3
8 kV
Test level 3 (80 - 2000 MHz)
10 V/m
- Power line
2 kV
- Data line
1 kV
- Power line, line/line: test level 2
0,5 kV
- Power line, line/earth: test level 3
1 kV
- Data line: test level 3
1 kV
10 kHz - 150 kHz
3V
150 kHz - 80 MHz
10 V
Test level 4
-
EN 61000-4-3, Electromagnetic fields
EN 61000-4-4, Fast transients (burst),
Test level 3, x
EN 61000-4-5 Surge voltage
EN 61000-4-6 Cable-based RF faults,
Test level 3
EN 61000-4-9 Impulse shaped magnetic fields
EMV emitted immunity
EN 55022
FCC 47 CFR Part 15
German Lloyd
Stability
Vibration
IEC 60068-2-6
German Lloyd
B 1)
8 kV
15 kV
20 V/m
4 kV
4 kV
1 kV
2 kV
4 kV
3V
10 V
300 A/m
H 1)
8 KV
15 kV
20 V/m
4 kV
4 kV
1 kV
2 kV
4 kV
3V
10 V
300 A/m
A 1)
Class A
Yes
Class A
Yes
Rules for Classifikation and Construction VI-7-3 - Yes
Part 1 Ed. 2001
B 1)
Yes
Yes
Yes
H 1)
Yes
Yes
Test FC, test level in line with IEC 61131-2V
Guidelines for the Performance
of Type Tests Part 1
Normal Installation in line with EN 61850-3
Test Ea, test level in line with IEC 61131-2
Normal Installation in line with EN 61850-3
Yes
-
Yes
Yes
Yes
Yes
Yes
-
Yes
Yes
Yes
Yes
Yes
Yes
IEC 870-2-2 Table 3
IEC 60068-2-27
IEC 870-2-2 Table 3
1) Product code A: Certification = CE, UL
Product code B: Certification = CE, UL, GL, Railway (along track), Substation, ATEX
Product code H: Certification = CE, UL, GL, Railway (along track), Substation
The media modules in Table 1 to 3 (see page 5) have the certification “A”.
Shock
Network size
AUI port
Length of a AUI cable
TP/TX port 10/100/1000BASE-T/TX
Length of a twisted pair segment
F/O port 10BASE-FL
Product code Wave length
-M4
MM
850 nm
-M4
MM
850 nm
50 m max.
100 m (328 ft) max. (cat5e cable with 1000BASE-T)
Fiber
50/125 µm
62.5/125 µm
System attenuation
0-9.5 dB
0-12.5 dB
F/O port 100BASE-FX
Product code
Wave length
Fiber
System attenuation
-M2, -M4
MM
1300 nm
50/125 µm
0-8 dB
-M2, -M4
MM
1300 nm
62.5/125 µm
0-11 dB
-S2
SM
1300 nm
9/125 µm
0-16 dB
-L2
LH
1550 nm
9/125 µm
7-29 dB
-P9
MM POF 650 nm
980/1000 µm
0-14.0 dB
-G2
LH+
1550 nm
9/125 µm
14-47 dB
F/O port 100BASE-FX (SFP Fiberoptic Fast ETHERNET Transceiver)
Product code
Wave length
Fiber
System attenuation
M-FAST-SFP-...
-MM/LC (EEC) MM
1310 nm
50/125 µm
0-11 dB
-MM/LC (EEC) MM
1310 nm
62.5/125 µm
0-8 dB
-SM/LC (EEC) SM
1310 nm
9/125 µm
0-13 dB
-SM+/LC (EEC) SM
1310 nm
9/125 µm
10-29 dB
-LH/LC
SM
1550 nm
9/125 µm
10-29 dB
F/O port 1000BASE-FX (SFP Fiberoptic Gigabit ETHERNET Transceiver)
Product code Wave length
Fiber
System attenuation
M-SFP-...
-SX/LC (EEC) MM
850 nm
50/125 µm
0-7.5 dB
850 nm
62.5/125 µm
0-7.5 dB
-SX/LC (EEC) MM
-MX/LC
MM
1310 nm
50/125 µm
0-8 dB
-MX/LC
MM
1310 nm
62,5/125 µm
0-8 dB
-LX/LC (EEC) SM
1310 nm 1)
50/125 µm
0-11 dB
1)
1310 nm
62.5/125 µm
0-11 dB
-LX/LC (EEC) SM
Expansion
0-2,000 m
0-3,000 m
Fiber data
3.0 dB/km; 400 MHz*km
3.2 dB/km; 200 MHz*km
Expansion
0-5 km
0-4 km
0-30 km
24-86 km
0-55 m
67-176 km
Fiber data
1.0 dB/km; 800 MHz*km
1.0 dB/km; 500 MHz*km
0.4 dB/km; 3.5 ps/(nm*km)
0.3 dB/km; 19 ps/(nm*km)
200 dB/km; 10 MHz*km
0.25 dB/km; 19 ps/(nm*km)
Expansion
Fiber data
0-5 km
0-4 km
0-25 km
25-65 km
40-104 km
1.0 dB/km; 800 MHz*km
1.0 dB/km; 500 MHz*km
0.4 dB/km; 3.5 ps/(nm*km)
0.4 dB/km; 3.5 ps/(nm*km)
0.25 dB/km; 19 ps/(nm*km)
Expansion
Fiber data
0-550 m
0-275 m
2 km
1 km
0-550 m
0-550 m
3.0 dB/km; 400 MHz*km
3.2 dB/km; 200 MHz*km
1.0 dB/km, 500 MHz*km
1.0 dB/km, 500 MHz*km
1.0 dB/km; 800 MHz*km
1.0 dB/km; 500 MHz*km