Supplement B: Diagnostic Message Description 1-71
DIAX04 AHS-03VRS
C704 - Attributes
C7/04
H1 Display :
Diag. mess.:
DE C704 Parameter nicht kopierbar
EN C704 Parameters not copyable
FR C704 Les paramètres ne peuvent pas être copiés.
ES C704 Parametros no se pueden copiar.
IT
C704 Parametri non copiabili
Mess. no.:
C704 (hex)
Class:
Command
C705 Locked with password
The parameter S-0-0267, Password offers the possibility to set a write
protection for the drive parameters. The diagnostic message C705
Locked with password indicates, that the command C700 Basic Load
has been started, although the drive parameters are protected with the
customer password.
See also the functional description: "Error Conditions of the Load Default
Settings Procedure"
C705 - Attributes
C7/05
H1 Display :
Diag. mess.:
DE C705 Verriegelt mit Passwort
EN C705 Locked with password
FR C705 Bloqué avec mot de passe
ES C705 Bloqueado con contraseña
IT
C705 Bloccato con parola chiave
Mess. no.:
C705 (hex)
Class:
Command
C800 Default parameter load
How to start the command:
This command can be started in 2 ways:
1. When "PL" is displayed on the drive controller (appears after a
change in firmware version), by pressing the S1 button beneath the
display.
2. By starting the P-0-4094, C8 Default parameter load
What the command does:
All the parameters are cleared and preset with their default (initial) value.
Process blocks and control loop settings are overwritten, too.
Default parameters:
Default values are stored in the drive for all parameters which figure in
the list S-0-0192, IDN-list of backup operation data. They define a
basic state of the drive that permits the drive to be switched "ready for
operation" (display "bb“). Mechanical components like gear and load as
well as the control loop settings therefore are not taken into
consideration.
See also the functional description: "Basic parameter block".
DOK-DIAX04-AHS-03VRS**-FK01-EN-P