Download User`s Manual - Power Electronics

Transcript
SD100| Functions List
LED
Parameter name
display
F25
F26
F27
F28
F29
F30
F31
F32
F33
F34
F35
F36
F37
F38
Min/Max
range
Description
This parameter sets high limit of the run
Frequency
0/400 frequency.
high limit
[Hz]
It cannot be set above F21 – [Max
frequency].
This parameter sets low limit of the run
Frequency low 0/400 frequency.
It cannot be set above F25 - [Frequency
limit
[Hz]
high limit] and below F23 – [Start
frequency].
Torque Boost
0 Manual torque boost
0/1
select
1 Auto torque boost
This parameter sets the amount of
Torque boost
torque boost applied to a motor during
in forward
0/15 [%] forward run.
direction
It is set in percent of Max output voltage.
This parameter sets the amount of
Torque boost
torque boost applied to a motor during
in reverse
0/15 [%] reverse run.
direction
It is set as a percent of Max output
voltage
0 Linear
V/F pattern
0/2
1 Square
2 User V/F
User V/F
0/400
[Hz]
frequency 1
User V/F
0/100 [%]
voltage 1
This parameter is active when F30 –
User V/F
0/400
[Hz] [V/F pattern] is set to 2 {User V/F}.
frequency 2
It cannot be set above F21 – [Max
User V/F
0/100 [%] frequency].
voltage 2
The value of voltage is set in percent of
User V/F
0/400 [Hz] H70 – [Motor rated voltage].
frequency 3
The values of the lower-numbered
User V/F
0/100 [%] parameters cannot be set above those of
voltage 3
higher-numbered.
User V/F
0/400 [Hz]
frequency 4
User V/F
voltage 4
0/100 [%]
Factory
defaults
Adjustable
during run
60.0
X
0.5
X
0
X
5
X
5
X
0
X
15.0
X
25
X
30.0
X
50
X
45.0
X
75
X
60.0
X
100
X
23