Download miniBATTEN - te
Transcript
TE-X24RGB miniBATTEN 2.3 SETT ING UP WITH A D MX512 CONT ROLLER 2.3-1 DMX512 ADDRESSING WITHOUT ID ADDR ESSING (STAGE 1 MOD E) ● Conne ct the DMX512 controller to the units i n series . has 10 DMX channels so th e DMX Addr ess es should incr ease by incr ements of 10 (e.g. 1,11,21,31... ) ●T he ID addr es s has no t been set so th er efore when u sing the contro ller Ch9 must be inactiv e ( CH9=0 ) . ● Each D MX Address may be used as many times as r equired. ● Any DMX address in t he range fr om 001 to 512 may be used. ● Each u nit Exampl e : .... ........ DM X512 CON TR OLL ER The figur e above sh ows a simple D MX512 layo ut with the s tart ing address of the first uni t set at 1, with th e second set at 11 and so o n... ( Note that when used in this way, the CH9 ID function must be inacti v e (CH9=0)) 2.3-2 DMX512 ADDRESSING WITH ID ADDRESS (STAGE 1 M ODE) ● Conne ct the DMX512 controller to the units i n series has 10 DMX channels so th e DMX Addr ess es should incr ease by incr ements of 10 (e.g. 1,11,21,31... ) ● Each D MX Address may be used as many times as r equired. ● Any DMX address in t he range fr om 001 to 512 may be used. ● Each D MX addr ess may carry up to 66 separate ID a ddresses. ● 【ID】should be s et in the menu on each unit in asce nding values (i .e. 1,2,3...) ● ID add resses ar e accessible fr om Ch 9 on the DMX512 controller. ● Each u nit 7 ADD : 19 Lacist St. Wesbrark, Maine, U.S.A. (04092) Phonel : (1) 207-712-3004 [email protected] http://www.te-lighting.com