Download E-Series, Extended Range and E
Transcript
TROUBLESHOOTING Electronic Fuel Pump Relay (A/B) U0109, U016C — Lost Communication with Fuel Pump Control Module A/B Description The SRM repeats the signal from the second EFPR to the PCM over the CAN bus. The PCM monitors this communication. If there is a lack of communication for a long enough period of time, a fault is set. Possible Causes 앫 Wire fault between the EFPR and SRM 앫 Wire fault between SRM and PCM 앫 No power to the EFPR 앫 SRM fault 앫 CAN bus fault 앫 Blown fuse 앫 Refer to the Ford Powertrain Control/Emissions Diagnosis Service Manual for a list of other causes. Symptom — Diagnostic Aid — Action Refer to the Fuel Pump Control Module Electrical Continuity Test procedure and also the Smart Relay Module Electrical Test procedure in Diagnostic Tests and Procedures. P025A, P027A — Fuel Pump Control Module Circuit Range/Performance Description The SRM receives the output of the second fuel pump monitor line and repeats the output over the CAN bus to the PCM. The PCM monitors the commanded output versus the monitor’s feedback. If the monitor is out-of-range, a fault is set. Possible Causes Refer to the Ford Powertrain Control/Emissions Diagnosis Service Manual for a list of other causes. Symptom Poor starts, rough idle, hesitation/surge. Diagnostic Aid — Action Refer to the Fuel Pump Control Module Electrical Continuity Test procedure in Diagnostic Tests and Procedures. Page 15