Download 700S and 700H Frame 11 Replacement Power Structures
Transcript
Installation Instructions PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Introduction Use this document to install a replacement power structure on a PowerFlex 700S or 700H frame 11 drive. This document covers the following replacement power structures: Spare Module Catalog PowerFlex 700H String AC Input SK-H1-PWRMOD-E460 20CE460 20CF460 SK-H1-PWRMOD-E502 20CE502 20CF502 SK-H1-PWRMOD-E590 20CE590 20CF590 SK-H1-PWRMOD-D590 20CC590 20CD590 SK-H1-PWRMOD-D650 20CC650 20CD650 SK-H1-PWRMOD-D730 20CC730 20CD730 What You Need to Do PowerFlex 700H DC Input 20CK460 20CM460 20CK502 20CM502 20CK590 20CM590 20CH590 20CJ590 20CH650 20CJ650 20CH730 20CJ730 PowerFlex 700S AC Input 20DE460 20DF460 20DE502 20DF502 20DE590 20DF590 20DC590 20DD590 20DC650 20DD650 20DC730 20DD730 PowerFlex 700S DC Input 20DK460 20DM460 20DK502 20DM502 20DK590 20DM590 20DH590 20DJ590 20DH650 20DJ650 20DH730 20DJ730 ❐ Step 1: Configure new power structure ❐ Step 2: Remove power from existing drive ❐ Step 3: Remove old power structure ❐ Step 4: Install new power structure ❐ Step 5: Connect new power structure to components in drive ❐ Step 6: Install product identification label on new power structure ❐ Step 7: Start drive 2 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Step 1: Configuring the New Power Structure Before configuring the power structure you must remove the protective covers from the drive. Refer to publication PFLEX-IN006…, Installation Instructions - PowerFlex 700S and 700H High Power Drives, for assistance in removing these covers. Configuring a DC Input Drive Power structures are shipped from the factory pre-configured for DC input operation. Connecting an AC Input Drive Power structures are shipped from the factory pre-configured for DC input operation. When installing a replacement power structure on a drive with AC input, you must remove the X2 plug from it’s protective sleeve and plug the cable into the ASIC and Rectifier board(s). Task A Description Remove the cover from the ASIC board assembly. E Disconnect the ASIC fan from the assembly by unplugging the cable from X1 on the ASIC board (see Figure 1 on page 3 for location). Remove the cover from the connector on the loose cable (bundled with the flat gate driver board cables) and connect the cable to the X2 connector on the ASIC board (see Figure 1 on page 3 for location). Connect the other end of the cable connected to X2 on the ASIC board to the X13 connector for the Rectifier board(s) on the V Phase and W Phase (if present) power stack (see Figure 2 on page 3 for location). Connect the fan cable to the X1 connector on the ASIC board. F Install the cover on the ASIC board assembly. B C D PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Figure 1 ASIC Board Connections X6 X9 X15 H1 H2 H3 H4 H5 H6 H7 Connect cable to X2 connector X2 X1 X1 connector H8 H9 H10 H11 H12 H13 X3 X4 X5 Figure 2 Rectifier Board Connectors Cable connected to X2 on ASIC board X13 connectors for Rectifier boards 3 4 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Configuring the EMC Filter Frame 11 size drives are equipped with common mode capacitors. To guard against drive damage, these capacitors should be disconnected depending upon the type of ground system on which the drive is installed. Installation on an Ungrounded Distribution System or High Resistive Ground If you are installing a 400/480V AC input drive on an ungrounded distribution system or high resistive ground, you: • Must move the common mode jumper to the disconnected position refer to Move the Common Mode Jumper to the Disconnected Position on page 6. • Should insulate terminal X4 on the Rectifier circuit board- refer to Insulate Terminal X4 on the Rectifier Circuit Board on page 7. If you are installing a 600/690V AC input drive on an ungrounded distribution system or high resistive ground, you: • Must move the common mode jumper to the disconnected position refer to Move the Common Mode Jumper to the Disconnected Position on page 6. • Must insulate terminal X4 on the Rectifier circuit board- refer to Insulate Terminal X4 on the Rectifier Circuit Board on page 7. Installation on a Grounded B Phase Delta System If you are installing a drive on a grounded B phase Delta system, you: • Must move the common mode jumper to the disconnected position refer to Move the Common Mode Jumper to the Disconnected Position on page 6. • Must insulate terminal X4 on the Rectifier circuit board- refer to Insulate Terminal X4 on the Rectifier Circuit Board on page 7. Note: Refer to Wiring and Grounding Guidelines for Pulse Width Modulated (PWM) AC Drives - Installation Instructions, publication DRIVES-IN001…, for additional information on an ungrounded distribution system or high resistive ground installation. PowerFlex® 700S and 700H Frame 11 Replacement Power Structures 5 The jumper is located on the Rectifying Module(s). For drives with one Rectifying Module, it is located on the upper-right side of the middle power stack (V Phase). For drives with two Rectifying Modules, they are located on the upper-right side of the middle (V Phase) and right-side (W Phase) power stacks. Voltage Class 400/480V AC 600/690V AC Amps 590 650 730 460 502 590 Number of Rectifying Modules 2 2 2 1 1 2 Figure 3 Common Mode Jumper and Rectifier Circuit Board Location Common Mode jumper There is one jumper located on each Rectifying Module. The Rectifying Modules are located on the upper-right side of the center and right side power stack of the drive’s power structure. Front View of Assembly Rectifier Circuit Board 6 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Move the Common Mode Jumper to the Disconnected Position 1. Follow the lettered steps below to move the common mode jumper to the disconnected position (refer to Figure 3 on page 5 for jumper location). Task A Description Loosen the upper screw. B Remove the lower screw. Move the jumper to the horizontal position. C Install and tighten the screws. D A Front View of Power Structure D C B Rectifying Circuit Board PowerFlex® 700S and 700H Frame 11 Replacement Power Structures 7 Insulate Terminal X4 on the Rectifier Circuit Board 1. Follow the lettered steps below to insulate terminal X4 on the Rectifier circuit board (refer to Figure 3 on page 5 for jumper location). Task A Description Remove the screw from the X4 connection on the Rectifier circuit board. B Insulate the top and bottom of the X4 connection on the Rectifier circuit board. Important: Do not install the screw and washer that was removed from this connection. A Side View of Power Structure B X4 X4 X1 X1 X41 X41 Rectifier Circuit Board 8 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Step 2: Removing Power From the Existing Drive ATTENTION: To avoid an electric shock hazard, verify that the voltage on the bus capacitors has discharged before servicing the drive. Check the DC bus voltage at the Power Terminal Block by measuring between the +DC and -DC terminals, between the +DC terminal and the chassis, and between the -DC terminal and the chassis. The voltage must be zero for all three measurements. ! Remove power before making or breaking cable connections. When you remove or insert a cable connector with power applied, an electrical arc may occur. An electrical arc can cause personal injury or property damage by: • sending an erroneous signal to your system’s field devices, causing unintended machine motion • causing an explosion in a hazardous environment Electrical arcing causes excessive wear to contacts on both the module and its mating connector. Worn contacts may create electrical resistance. 1. Turn off and lock out input power. Wait five minutes. 2. Verify that there is no voltage at the drive’s input power terminals. 3. Measure between the +DC and -DC terminals, between the +DC terminal and the chassis, and between the -DC terminal and the chassis. The voltage must be zero for all three measurements. L1 L2 L3 I O Step 3: Removing the Old Power Structure Refer to the PowerFlex 700H/S Frame 11 Hardware Service Manual, publication PFLEX-TG003…, for information about removing the power structure. Step 4: Installing the New Power Structure Refer to the PowerFlex 700H/S Frame 11 Hardware Service Manual, publication PFLEX-TG003…, for information about installing the power structure. PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Step 5: Connecting the Power Structure to Components in the Drive 9 You must connect the power structure to control components on the control frame. If the drive has DC input, you must also connect the precharge circuit. Connections to the 700S Control Frame When installing a power structure in a PowerFlex 700S drive, you must make the following connections between the ASIC and Fiber Optic Interface, Power Supply Voltage Feedback, Common Mode Filter and Rectifier boards. Connect this component: termination point in the Power Structure to … ASIC Board: H1 (fiber optic connector) ASIC Board: H2 (fiber optic connector) ASIC Board: H3 (fiber optic connector) ASIC Board: H4 (fiber optic connector) ASIC Board: H5 (fiber optic connector) ASIC Board: H6 (fiber optic connector) ASIC Board: H7 (fiber optic connector) ASIC Board: X10 ASIC Board: X2 Power Supply Voltage Feedback Board: J8 Power Supply Voltage Feedback Board: J5 (fiber optic connector) Power Supply Voltage Feedback Board: J4 (fiber optic connector) …this component : termination point on the Control Frame Fiber Optic Interface Board: J8 (fiber optic connector) Fiber Optic Interface Board: J9 (fiber optic connector) Fiber Optic Interface Board: J10 (fiber optic connector) Fiber Optic Interface Board: J11 (fiber optic connector) Fiber Optic Interface Board: J12 (fiber optic connector) Fiber Optic Interface Board: J14 (fiber optic connector) Fiber Optic Interface Board: J13 (fiber optic connector) Insulate and do not connect Rectifier Board: X13 (AC input drives only) Common Mode Filter Board: J5 Fiber Optic Interface Board: J6 Fiber Optic Interface Board: J7 Figure 4 Connections for 700S Drives with Phase II Control Make and verify these connections To X13 Connector for Rectifier Board (AC Input Drives Only) ASIC Board X2 H1 (Gate Enable) H2 (U Gate) RJ45 Connector P1 Embedded P2 EtherNet I/P Option Board H3 (V Gate) H4 (W Gate) H5 (ADconv) P1 TX SynchLink Option Board RX H6 (Vbus Tx) RS232 CompactFlash Memory Compact I/O P3 P2 P2 80 H7 (Vbus Rx) P7 P10 P1 Inside Power Structure P1 NetLinx Daughtercard 34 P1 Feedback Option Board 40 34 P3 P12 Main Control Board J2 2 J1 Fiber Optic Interface Board -12 V +5V J6 Tx +24V 8 9 9 8 9 10 P21 P5 TB1 TB2 J4 Tx 80W Power Supply J2 DCDC+ J1 -U -V -W Power Supply Voltage Feedback X2 20-VB00601 J4 J17 2 P4 J5 Rx Fiber J7 Rx 16 P13 J8 2 J5 J3 P6 Second Encoder P3 or Safe Off Option Board J5 +12 V J1 P1 P11 P2 Common Mode Filter Board J8 J9 J10 J11 J12 J14 J13 +24 V Iso 30 P2 Feedback Inputs X10 120 Logix Expansion Board P3 Comm Input Fiber Optic Cables P9 J16 J18 2 J15 X4 DPI Interface X1 Board J2 DPI Bezel X3 J3 J1 HIM DOOR DriveLogix 2 Battery 700S Control Assembly (Phase II) M6 Control Pan Fan M 2 External 24V DC 1 = 24V 3 = Common (75W min) 20 DPI Comm Option PWR STS EXAMPLE: 20-HIM-A3 PORT MOD NET A NET B DPI Assembly HIM EXTERNAL DPI 10 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Figure 5 Termination Points on the ASIC Board Fiber Optic connections to the Fiber Optic Interface board X6 X9 X15 H1 H2 H3 H4 H5 H6 H7 Connect to Pre-charge circuitry on DC input drives X2 X1 Connects to fan on ASIC assembly cover Connects to X13 connector for the Rectifier boards on the center and right side power stacks on AC input drives H8 H9 H10 H11 H12 H13 X3 X4 X5 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures 11 Figure 6 Termination Points on 700S Boards Power Supply Voltage Feedback Board Fiber Optic Interface Board J4 J5 J8 J8 J9 J10 J11 Common Mode Filter Board J12 J14 J13 J1 J6 J7 J5 J5 12 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Connections to the 700H Control Frame When installing a power structure in a PowerFlex 700H drive, you must make eight connections between the ASIC and Fiber Optic Adapter and Rectifier boards. Connect this component: termination point in …this component : termination point on the the Power Structure to … Control Frame ASIC Board: H1 (fiber optic connector) Fiber Optic Adapter Board: H1 (fiber optic connector) ASIC Board: H2 (fiber optic connector) Fiber Optic Adapter Board: H2 (fiber optic connector) ASIC Board: H3 (fiber optic connector) Fiber Optic Adapter Board: H3 (fiber optic connector) ASIC Board: H4 (fiber optic connector) Fiber Optic Adapter Board: H4 (fiber optic connector) ASIC Board: H5 (fiber optic connector) Fiber Optic Adapter Board: H5 (fiber optic connector) ASIC Board: H6 (fiber optic connector) Fiber Optic Adapter Board: H6 (fiber optic connector) ASIC Board: H7 (fiber optic connector) Fiber Optic Adapter Board: H7 (fiber optic connector) ASIC Board: X10 Fiber Optic Adapter Board: X2 ASIC Board: X2 Rectifier Board: X13 Figure 7 Connections Between the Power Structure and Control Frame (700H Drives) Make and verify these connections X10 H1 ASIC Board H2 H3 H4 H5 H6 H7 To X13 Connector for Rectifier Board (AC Input Drives Only) X2 Inside Power Structure Fiber Optic Cables X2 H1 H2 H3 H4 H5 H6 H7 X3 +24V 1 Common 2 Fiber Optic Adapter Board X1 37 X2 X1 700H Control Board X2 (Slot A) 20C-DA1-A (24V dc Digital Input w/ Analog I/O) or 20C-DA1-B (115V ac Digital Input w/ Analog I/O) 10 Analog I/O 8 / 10 Digital Inputs X3 (Slot B) X4 (Slot C) X5 (Slot D) 20C-DO1 (Digital Output Option) Option Board Option Board X7 (RS-232 Programming Port) X6 (Slot E) X1 20C-DPI1 (DPI Communications Option) X3 3 3 Digital Digital Outputs Outputs DPI Interface X1 J2 X4 HIM Bezel X3 20 HIM DPI COMM (Option) PWR STS PORT MOD NET A NET B X2 DPI Assembly 700H Control Assembly J1 J3 HIM PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Figure 8 Termination Points on Fiber Optic Adapter Board (700H Drives) Back View H7 H6 H5 H4 H3 H2 H1 X2 13 14 PowerFlex® 700S and 700H Frame 11 Replacement Power Structures Pre-Charge Connections on Drives with DC Input You must connect the ASIC board connectors X9 and X15 to the X50 terminal block for the pre-charge circuit. The X50 terminal block is located on the Control Frame. Refer to the Installation Instructions - PowerFlex 700S and 700H High Power Drives, publication PFLEX-IN006…, for information regarding the pre-charge circuit. X50 Terminal Block Connections ASIC Board Connector Terminal X9 25 26 X15 21 23 to X50 Terminal ... 1 ... 2 ... 3 ... 4 Pre-Charge Circuit Connection Description Pre-charge Complete Signal (+24V DC) Pre-charge Complete Signal (Common) Charge Relay Contact Charge Relay Contact Figure 9 Sample Pre-charge Wiring Diagram Customer Connections - External precharge circuitry is shown as dashed lines. Terminal Block DC+ M Drive Connections X50 ASIC Board X9 F1 R1 CR2 1 25 2 26 3 21 M DC Source 4 23 Precharge Complete Charge Relay* X15 CR1 Pilot Relay M F2 R2 CR2 DC- *Refer to the “ASIC Board Charge Relay Contact Ratings” table below. CR1 M Main DC Contactor M CR2 Precharge Important: For DC Input Only. Do Not Install on AC Input Drives ASIC Board Charge Relay Contact Ratings Load Rated load Rated carry current Max. switching voltage Max. switching current Max. switching power Failure rate (reference value) Resistance load (cos φ = 1) 8 A at 250 VAC: 5 A at 30 VDC 8A 250 VAC; 30 VDC, (400 VAC) AC 8 A; DC 5 A 2,000 VA; 150 W 5 VDC 10 mA (for gold plating 0.35 µ min.) PowerFlex® 700S and 700H Frame 11 Replacement Power Structures 15 All frame 11 replacement power structures are shipped from the factory Step 6: Installing the Product Identification Label without a product identification label on the drive. If you are installing the power structure in a 700S drive, you should label it with the accompanying on New Power Structure PowerFlex 700S label. If you are installing the power structure in a 700H drive, you should label it with the accompanying PowerFlex 700H label. ! D ANG ER Risk of Disco electric sh nn oc verify ect powe k and de ath. r, wa DC bu it 5 mi Follo nu w ins s voltage tructi befor tes and Earth groun ons in ma e servicin d req uired nual befor g. . e use. OR ! DA NGER Risk of Disco electric shoc nnec t powe k and verify DC bus r, wait death. Follo 5 minu w instru voltage befor tes and Earth ction e servi s grou cing. nd requ in manu al befor ired. e use. Step 7: Starting the Drive 1. Install the protective covers on the drive. Refer to publication PFLEX-IN006…, Installation Instructions - PowerFlex 700S and 700H High Power Drives, for assistance in installing these covers. 2. Start up the drive. Refer to the Start Up procedures in the appropriate publication: – User Manual - PowerFlex 700S Drives with Phase II Control, 20D-UM006…. – Programming Manual - PowerFlex 700H Drives, 20C-PM001…. Reference Materials Allen-Bradley publications are available on the internet at www.rockwellautomation.com/literature. The following manuals are recommended for general drive information: Title Wiring and Grounding Guidelines for Pulse Width Modulated Drives Industrial Automation Wiring and Grounding Guidelines Preventive Maintenance of Industrial Control and Drive System Equipment Safety Guidelines for the Application, Installation and Maintenance of Solid State Control A Global Reference Guide for Reading Schematic Diagrams Guarding Against Electrostatic Damage Publication DRIVES-IN001… 1770-4.1 DRIVES-TD001… SGI-1.1 0100-2.10 8000-4.5.2 The following manuals are recommended for detailed PowerFlex 700H and 700S information: Title Reference Manual - PowerFlex 700S Drives with Phase II Control User Manual - PowerFlex 700S Drives with Phase II Control Programming Manual - PowerFlex 700H Drives Installation Instructions - PowerFlex 700S and 700H High Power Drives Hardware Service Manual - PowerFlex 700S and 700H Frame 11 Drives Publication PFLEX-RM003… 20D-UM006… 20C-PM001… PFLEX-IN006… PFLEX-TG003… For Allen-Bradley Drives Technical Support: Title Allen-Bradley Drives Technical Support Online at... www.ab.com/support/abdrives www.rockwellautomation.com Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204 USA,Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium,Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong,Tel: (852) 2887 4788, Fax: (852) 2508 1846 Publication PFLEX-IN011C-EN-P - August 2008 Supersedes PFLEX-IN011B-EN-P - March 2006 16 360399-P03 Copyright © 2008 Rockwell Automation. All rights reserved. Printed in the U.S.A.