Download - Fujitsu
Transcript
On the DC Input Power Model, the "Environmental Status" and Some Part of the "FRU Status" Information Is Not Displayed (CR 6853843) This issue is resolved by updating the system firmware to 7.2.7.b or later. On the DC input power model of SPARC Enterprise T5120 Server, when you execute the prtdiag command of Solaris OS, the "Environmental Status" and some part of the "FRU Status" information is not displayed. Incomplete Data Output Example: ============================ Environmental Status ============================ <-- No data output. ============================ FRU Status ============================ Location Name Status -----------------------------------------------------SYS MB enabled SYS HDD0 enabled SYS HDD1 enabled <-- Part of data is not on display. Workaround: None. From ILOM, check the component information and the status of fan, temperature, power sensor and so on. 114 SPARC Enterprise T5120 and T5220 Servers Product Notes • March 2010