Download Nd-Series - Serrubec
Transcript
ND-Series A New Standard In Grade 1 Security Extra Heavy Duty Commercial INDEX ND-Series locks are for commercial, institutional and industrial use, such as schools, hospitals and factories, where a long life of dependable operation must be combined with a high degree of resistance to physical abuse. Popular functions of all lever designs are also available in Vandlgard , where levers are free-wheeling in the locked position to resist more forceful attacks. ® Performance Features Tested to exceed 3,000,000 cycles, greatly exceeding the 800,000 cycle ANSI Grade 1 requirement. Cylinders 8 Designs & Finishes 4 Door Preparation 3 Door Handing 12 Exploded View 2 Functions 6-7 How to Order 13 Interchangeable Cores 8-9 Latches 10 Performance Features 2 Specifications 3 Strikes 11 ® Exceeds ANSI A156.2 Series 4000 Grade 1 locked lever torque requirements. Vandlgard Features Vandlgard® functions have free-wheeling levers to resist force when locked. Wiring for Electrified Locks 5 12 Independent heavy duty spring cages for effective lever support. Thru-bolted mechanism for positive interlock to door. Concealed mounting screws. Steel Latchbolt. Exploded View Outside lever Rose Outside Spring Cage Assembly Chassis Adjusts for 1 5/8˝ - 2 1/8˝ thick doors Push-Turn Button (Certain Function) Provides visible locking status Cylinder 6-Pin Everest Standard Anti-rotation Plate Inside Spring Cage Assembly Integrated spindle/springcage reduces lever wobble and droop Latch Screws Springcage Screws Rose Inside Lever Latch 1/2˝ Throw Strike 2 Strike Screws On our cove r, the ND-Series OMEGA in Satin Nickel. Specifications Certifications Handing: All ND-Series lever locksets are non-handed. ANSI Meets or exceeds A156.2 Series 4000, Grade 1 strength and operational requirements. Meets A117.1 Accessibility Code. Door Thickness: 1⅝˝ to 2⅛˝ (41mm–54mm) standard including Vandlgard® functions. 1¾˝ - 2˝ for function D85. See accessories (Page 11) for spacers required for 1³ ⁄ 8 ˝ doors. Federal Meets FF-H-106C Series 161. California State Reference Code (CSFH) Backset: 2³⁄₄˝ (70 mm) standard. 2³ ⁄ 8 ˝, 3¾˝ and 5˝ (60 mm, 95 mm, 127 mm) optional. ( Fo rmerly Title 19, California State Fire Marshal Standard ) Faceplate: Brass, bronze or stainless steel. 1⅛˝ x 2¼˝ (29 mm x 57mm) square corner, beveled. M E A Certification All electrified locking (fail-safe, unlocked by switch or power failures) functions accepted for use in New York City by the City of New York, Department of Buildings (MEA 24-04-E). Lock Chassis: Zinc plated for corrosion resistance. Latch Bolt: Steel, ½˝ (12mm) throw, deadlocking on keyed and exterior functions. ³⁄₄˝ (19 mm) throw anti-friction latch available for pairs of fire doors. Exposed Trim: Levers: Pressure cast zinc, plated to match finish symbols. Roses: Solid brass. Strike: ANSI curved lip strike 1¼˝ x 4⅞˝ x 1³⁄₁₆˝ lip to center standard. Optional strikes, lip lengths and ANSI strike box available. See page 12. All levers with less than ½˝ (64mm) returns comply; levers return to within ½˝ of door face. All levers with less than ½˝ (64mm) returns comply with California Fire Safety Codes. 3/4˝ and 1/2˝ throw latch approved for Hurricane Resistance with Miami-Dade County, Florida and the Florida Building Commission. UL / cUL: All locks listed for A label single doors, 4´ x 8´. Letter F and UL symbol Cylinder & Keys: 6-pin Everest C123 keyway standard with two patented nickel silver keys per lock. Keying Options: Interchangeable core and Primus® high security cylinders. Master keying, grand master keying and construction keying. Warranty: Seven-year limited for all functions including Vandlgard®. Door Preparation Lever Designs 1-1/8" 2-3/4" 29mm 70mm 2-1/4" 57mm 1" dia 25mm 5/16" dia. 8mm 2-3/4" 70mm 2-1/8" 54mm 3 Lever Designs & Finishes Lever Designs & Finishes ATHENS Symbol: ATH (L-Series 07) Material: Pressure cast zinc lever; wrought brass rose Finishes: 605, 606, 612, 613, 619, 625, 626 SPARTA Symbol: SPA (L-Series 17) Material: Pressure cast zinc lever; wrought brass rose Finishes: 605, 606, 612, 613, 619, 625, 626 626 606 RHODES Symbol: RHO (L-Series 06) Material: Pressure cast zinc lever; wrought brass rose Finishes: 605, 606, 612, 613, 619, 625, 626 OMEGA Symbol: OME (L-Series Omega) Material: Pressure cast zinc lever; wrought brass rose Finishes: 605, 606, 612, 613, 619, 625, 626 612 619 TUBUL AR (L-Series 03) Symbol: TLR Material: Pressure cast zinc lever; wrought brass rose Finishes: 605, 606, 612, 613, 619, 625, 626 605 Bright Brass 606 Satin Brass 612 Satin Bronze 613 Oil Rubbed Bronze 626 Keyed functions available with Full Size Interchangeable Core options. 619 Satin Nickel 625 Bright Chromium Plated Keyed functions available with Smal l Format Interchangeable Core options. * TACTILE WARNING (KNURLING) Change symbol designation as follows: 8AT for Athens 8RO for Rhodes 8SP for Sparta 8TR for Tubul ar* *Only available with Tubular lever. Only outside lever is knurled unless otherwise specified. 4 Extended Factory Lead Time Not available with Omega trim Finishes 605 Bright Brass 606 Satin Brass 612 Satin Bronze 613 Oil Rubbed Bronze 619 Satin Nickel 625 Bright Chromium Plated 626 Satin Chromium Plated 626 Satin Chromium Plated ND-SERIES VANDLGARD ™ WIT H Schlage ND-Series keyed lever locks with Vandlgard provide vandal resistant technology. Designed for maximum accessibility, security and durability, Vandlgard sets the standard for door hardware in educational facilities and other applications subject to heavy traffic or abuse. The unique features of Vandlgard prevent damage to internal lock components caused by excessive force from persons kicking, hitting or standing on the lever to gain access. Vandlgard functions maintain total key system and architectural design compatibility with Schlage’s regular ND-Series cylindrical locks. Levers have virtually replaced knobs in the marketplace for handicap accessibility. The added grip and leverage has created an increased opportunity for abuse or vandalism. This abuse often renders locks inoperable. In some cases the security of the door is violated leaving computer and laboratory equipment susceptible to theft. While this type of abuse is commonly associated with junior and senior high schools, it also occurs in universities, office buildings, commercial buildings, and public buildings. Locked lever freely rotates up and down while remaining securely locked. The Vandlgard function also increases resistance to over-rotation of the lever. Benefits & Features Superb warranty. All Vandlgard functions have a 7-year warranty. Reduce lever wobble and play. Integrated spindle and spring cage greatly reduces lever sag and wobble. Resists vandalism. Free-wheeling lever eliminates the ability to stand or exe rt excessive force on the end of the leve r. Ease of installation. Installs in under 2 minutes. Inner spindle operates independently of lever when locked ND-Series Vandlgard levers comply with ADA requirements. 5 Functions ANSI A156.2 Series 4000 Grade 1 Non-Keyed Locks Keyed Locks SCHLAGE ANSI SCHLAGE ANSI ND10S F75 Passage Latch Both levers always unlocked. ND50PD F82 Entrance/Office Lock † Push-button locking. Push-button locks outside lever until unlocked with key or by turning inside lever. ND12D F89 Exit Lock Outside lever always fixed. Inside lever always unlocked. ND53PD F109 Entrance Lock † Turn/push-button locking; pushing and turning button locks outside lever, requiring use of key until button is manually unlocked. Push-button locking; pushing button locks outside lever until unlocked by key or by turning inside lever. ND60PD F88 Vestibule Lock † Latch retracted by key from outside when outside lever is locked by key in inside lever. Inside lever is always unlocked. ND66PD F91 Store Lock † * Key in either lever locks or unlocks both levers. ND70PD F84 Classroom Lock † Outside lever locked and unlocked by key. Inside lever always unlocked. ND73PD F90 Corridor Lock † Locked or unlocked by key from outside. Push-button locking from inside. Turning inside lever or closing door releases button. When outside lever is locked by key it can only be unlocked by key. Inside lever is always unlocked. ND12DEL Electrically Locked (Fail Safe) Outside lever continuously locked electrically. Unlocked by switch or power failure. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. ND12DEU Electrically Unlocked (Fail Secure) Outside lever continuously locked until unlocked by electric current. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. ND25D ND40S ND44S ND170 Exit Lock Blank plate outside. Inside lever always unlocked. F76 Bath/Bedroom Privacy Lock Push-button locking. Can be opened f rom outside with small screwdriver. Turning inside lever or closing door releases button. Hospital Privacy Lock Push-button locking. Unlocked f rom outside by turning emergency turn-button. Turning inside lever or closing door releases button. Single Dummy Trim Dummy trim for one side of door. Used for door pull or as matching inactive trim. Safe School Locks 6 ND75PD Classroom Security Lock † Key in either lever locks or unlocks outside lever. Inside lever is always unlocked. † Keyed functions available with 6-pin (PD/LD), SFIC(GD/BD), or FSIC(RD/JD) cylinder. * Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only. Functions ANSI A156.2 Series 4000 Grade 1 Vandlgard Functions Keyed Locks SCHLAGE ANSI SCHLAGE ANSI ND91PD F82 ND80PD F86 ND92PD F109 ND93PD F88 ND94PD F84 ND80PDEL Electrically Locked (Fail Safe) † Outside lever continuously locked electrically. Unlocked by key outside or by switch or power failure. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. Electrically Unlocked (Fail Secure) † Outside lever continuously locked until unlocked by key or electric current. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. ND80PDEU ND82PD Storeroom Lock † Outside lever fixed. Entrance by key only. Inside lever always unlocked. F87 ND85PD Institution Lock † * Both levers fixed. Entrance by key in either lever. Faculty Restroom Lock ** Outside lever fixed. Entrance by key only. Push-button in inside lever activates visual “occupancy” indicator, allowing only emergency master key to operate. Turning inside lever or closing door releases visual occupancy indicator. Rotation of inside spinner-button provides lock-out feature by keeping indicator thrown. ND95PD ND96PD ND96PDEL Safe School Locks † Keyed functions available with 6-pin (PD/LD), SFIC(GD/BD), or FSIC(RD/JD) cylinders. * Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only. ** 85 function locks are not available in Full Size & Small Format Interchangeable Cores. ND96PDEU Entrance/Office Lock † Push-button locking. Push-button disengages outside lever until unlocked with key or by turning inside lever. Vandlgard is designed to disengage outside spindle from latch when in locked condition. Entrance Lock † Turn/push-button locking; pushing and turning button disengages outside lever, requiring use of key until button is manually unlocked. Push-button locking; pushing button disengages outside lever until unlocked by key or by turning inside lever. Vandlgard is designed to disengage outside spindle f rom latch when in locked condition. Vestibule Lock † Latch retracted by key from outside when outside lever is disengaged by key in inside lever. Inside lever is always unlocked. Vandlgard is designed to disengage outside spindle f rom latch when in locked condition. Classroom Lock † Outside lever disengaged and unlocked by key. Inside lever always unlocked. Vandlgard is designed to disengage outside spindle from latch when in locked condition. Classroom Security Lock † Key in either lever locks or unlocks outside lever. Inside lever is always unlocked. F86 Storeroom Lock † Outside lever always disengaged. Entrance by key only. Inside lever always unlocked. Vandlgard is designed to disengage outside spindle f rom latch when in locked condition. Electrically Locked (Fail Safe) † Outside lever continuously disengaged electrically. Unlocked by key outside or by switch or power failure. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. Vandlgard is designed to disengage outside spindle from latch when in locked condition. Electrically Unlocked (Fail Secure) † Outside lever continuously disengaged. until unlocked by key or electric current. Auxiliary latch deadlocks latchbolt when door is closed. Inside lever always free for immediate exit. Vandlgard is designed to disengage outside spindle from latch when in locked condition. 7 Standard Cylinders Full Size Interchangeable Core Schlage® locks are provided with cylinders precision built to extremely close tolerances and the highest standards of accuracy. Using only solid brass plugs, extruded brass shells, phosphor bronze springs, nickel silver keys and pins, ensures long life and ease of operation. For complete listing of cylinder parts, refer to the New ND-Series Service Manual (SC-2058). Schlage® f igure-8 interchangeable core (IC) locksets allow immediate rekeying at the door simply by using a special control key to replace the core. Conventional cylinders are available in Classic keyways or in patented Everest® keyways. Specify keyway to differentiate between Everest and Classic. Example: C (Classic) vs. C123 (Everest). Primus® High Security Cylinders Primus high security cylinders are available to add patented key control and varying degrees of geographical exclusivity to most Schlage 6-pin key systems, whether Everest or Classic keyways. In addition to a conventional pin tumbler mechanism, Primus cylinders incorporate a patented finger pin and sidebar design providing a “dual-locking” cylinder that is virtually pickproof. Resistance to drilling and other physical attack is optional by specifying 20-500 Series UL437 Listed cylinders. Classic Primus cylinders are recommended for upgrading existing Classic key systems. Due to its extended patent life, the newly designed Everest Primus is recommended for new key systems and for upgrading existing Everest® key systems. Specify keyway to differentiate between Everest and Classic. Example: CP (Classic) vs. C123 (Everest). Available in all lever designs, full size interchangeable cores can be integrated into any 5 or 6-pin Schlage key. To order complete locks with full size cores, change suffix f rom PD to RD. Example: ND53RD. To order locks l ess core, change suffix to JD. To order with full size construction core, change suffix to T D. Full Size Interchangeable Cores* Number Description 23-030 Conventional core 20-740 Primus high security core Cylinder for Most Functions *Available 606 and 626 finish only. Everest C123 keyway standard. Driver N123-127 Tailpiece is vertical (shown) for levers. Standard Cylinders* Levers Description 23-065 6-Pin conventional (standard) 20-765 Primus high security 20-565 Primus UL437 Listed high security 23-000 Hotel cylinder N123-042 Temporary construction plug, plastic for functions *Available in 606 and 626 finish only. Everest C123 keyway standard. 8 Small Format Interchangeable Core Available in all lever designs, the small format IC option is designed for Schlage Everest® B Family Restricted keyway cores and is also completely compatible with Best®, Falcon®, and other small format interchangeable cores. To order complete locks with Everest B Family Restricted keyway cores, change product suffix from PD to GD and provide letter of authorization from end user. Example: ND53GD. To order locks less core, change suffix to BD. To order with keyed brass construction cores, change suffix to HD. To order with disposable plastic construction cores, change suffix to BDC. Small Format Core Disposable Construction Core N523-091 Small Format Interchangeable Cores Number Description 80-036 7-Pin uncombinated Everest B Family Restricted keyways 80-037 7-Pin combinated Everest B Family Restricted keyways 80-043 6-pin uncombinated Falcon / Best keyways 80-033 7-pin uncombinated Falcon / Best keyways M204-152* N523-091 Disposable plastic construction core SFIC Driver Available 606 and 626 finish only. Specify keyway for existing systems. 80-033 and 80-043 cores are available in Best A, D, E, F, G, H, J, K, L, and M keyways. Specify keyway by suffixing “B” to keyway letter, e.g. “AB”. 80-036 and 80-037 Restricted keyway cores require a letter of authorization f rom the end user. Schlage assigns the keyway when establishing new Everest Restricted key systems. *M204-152 does not have a finish option. 9 Latches ND-Series latches are adjustable for flat or beveled edge doors. Latches and strikes are furnished in brass, bronze, or chrome f inishes to be compatible with lock trim. When ordering, specify quantity, part number, and finish. All ND-Series latches have ½˝ throw and 1˝ housings except 2⅜˝ backset latches, which includes sleeve G506-815 to fill a 1˝ edge bore. Standard latches are shown in bold type. Long Backsets ND-Series locks with 5˝ backsets are normally furnished with 1⅛˝ faceplates and 1˝ housings. Links installed in metal doors require one A501-567 sleeve and 43-005 (order separately) to join latch and link. 2-3/4˝ Latch Latches 2³⁄₄˝ 70mm (add to 2 ³⁄₄” backset latch) Deadlatch Springlatch ¹⁄₂˝ Throw ¹⁄₂˝ Throw Description 1¹⁄₈˝ (29mm) x 2¹⁄₄˝ (57mm) square corner 1” (25mm) x 2¹⁄₄˝ (57mm) square corner 1¹⁄₈" (29mm) x 2¹⁄₄" (57mm) square corner 1¹⁄₈˝ (29mm) x 2¹⁄₄˝ (57mm), 14-047 14-048 13-047 14-042 – – 13-048 _ 14-028 14-010 ³⁄₄˝ (19mm) throw for pairs of fire doors 3 ³⁄₄˝ 95mm Sleeve (A501-567) (43-005) Backset 2³⁄₈˝ 60mm Extension Link 1¹⁄₈˝ (29mm) x 2¹⁄₄˝ (57mm) Square corner Deadlatch Springlatch Door Reinforcement Schlage 37-001 reinforcing kit is used to reinforce and help prevent the collapse of hollow metal doors when locksets are tightly mounted. This kit should be used with long backsets for ND-Series lock installations in hollow metal doors to prevent lateral movement of the latchbolt. Specify door thickness, 1⅜˝or 1¾˝, when ordering reinforcement kits. ³⁄₄” Throw Anti-Friction Deadlatch for Pairs of Fire Doors Reinforcement Kit (37-001) Sleeve (A501-567) G506-815 Reinforcement 13/4˝ doors (A501-566) or 13/8˝ doors (A501-565) ANSI Strike–Standard Square Corner Box Strike (10-025) (10-013) 1 1/4˝ x 4 7/8˝ x 3/32˝ 1 1/8˝ x 2 3/4˝ x 3/32˝ Strikes All Schlage strikes are furnished complete with screws. The standard ND-Series strike has a 1³⁄₁₆˝ lip. When ordering separately specify quantity, product number, f inish, and lip length. Standard strikes are shown in bold type. Strikes Number Lip Length 10-013 1 1/8˝ (28mm) 1 1/8˝ x 2 3/4˝ (28mm x 70mm) Square corner, box 1 3/4˝ (38mm) 10-016 1 1/8˝ (28mm) 1 1/8˝ x 2 3/4˝ (28mm x 70mm), 3/4˝ (19mm) deep box for 14-042 fire door latch 10-025 1 3/16˝ (30mm) 1 3/8˝ (35mm) 1 1/4˝ x 4 7/8˝ (32mm x 124mm) ANSI K510-066 — 10 Description Box for 10-025 ANSI strike Rabbeted Latch and Strike Kit Rabbeted latch and strike kit finishes: 605, 626. This kit adapts square corner latches and 2 3/ 4˝ (28mm) high strikes for ½˝ (13mm) rabbeted door and frame preparations. Rabbeted Latch and Strike Kit (39-030) Typical Wiring Diagram for Electrified Locks Door Handing AC Power Source – EL or EU All Schlage® locks are reversible. Hand information is necessary to ensure proper finish of latchbolt and strike for split-finish locks. Fo l l ow the diagram to determine the hand of the door. The outside is the secure side or the corridor side. AC Operation Switch (Not Furnished) Rectifier To Lock Transformer (Not Furnished) 24V AC 115V AC Plug LH Left Hand INSIDE RH Right Hand Rectifier used on AC operation unit only. .35A @ 24V (Current requirements per lock) OUTSIDE INSIDE DC Power Source – EL or EU DC Operation Switch (Not Furnished) 24V DC LRB Left Hand Reverse Bevel OUTSIDE RRB Right Hand Reverse Bevel To Lock .15A @ 24V (Current requirements per lock) AC and DC Application Cut as close to plug as possible for DC operation. Plug into solenoid for AC operation. Discard for DC operation. Solenoid Rectifier Accessories 1-3/ 8˝ D-Series Lever Door Spacer* XN12-012 *For installation on 1 ³⁄₈” doors, two (2) spacers are required. Specify finish. 11 How to Order ND-Series Levers To order Schlage® products, descriptive data should be in the same sequence as shown. Line Item 1 1 2 3 Qty Product 2 3 Outside Des Fin 4 5 Inside Des Fin 6 7 Hand 8 Latch Strike 9 10 Door Thickness 11 Ext Dim Additional Details 12 13 14 Line item number Quantity Complete model number with function and cylinder type To order cylinder options, change “PD” at the end of the model number as follows: ND53PD Standard. ND53LD Less standard cylinder. For Primus® cylinder, specify this option and order Primus cylinder separately. ND53CD With temporary plastic construction cylinder. Double cylinder functions ordered less cylinder are furnished with these construction cylinders to maintain timing of key cams. ND53JD Prepared for full size interchangeable core, less core. For Primus core, specify this option and order Primus core separately. ND53RD With full size conventional interchangeable core installed. Order control keys separately. ND53T D With full size (temporary) construction core installed. Order all keys separately. ND53BD Prepared for small format (Falcon®, Best®, etc.) interchangeable core (SFIC), less core. ND53GD With Everest® B Family restricted keyway small format core installed. Order control keys separately. ND53HD With small format keyed brass construction core installed. Order all keys separately. ND53BDCWith small format disposable plastic construction core installed. Outside design / finish. Specify tactile warning (knurling) here as “8AT” for Athens®, “8RO” for Rhodes® or “8SP”for Sparta®. Inside design / finish. Leave blank if same as outside. Hand. Required for keyed knob designs and all split finish locksets. One hand per line item. Latch. Leave blank for standard or specify part number for optional latch. LLL=Less Latch. Strike. Leave blank for standard or specify part number for optional strike. LLL=Less Strike. Door thickness, if non-standard. Example: 200 = 2˝. Extension, to specify whether thick door is extended inside (EI), outside (EO), differently (ED) or equally (EE). Dimension for strike lip lengths. See strike page for availability of specific dimensions with specific strikes. 100 = 1˝ 118 = 1⅛˝ 114 = 1¼˝ 138 = 1⅜˝ 112 = 1½˝ 134 = 1¾˝ 200 = 2˝ 14 Keying detail (e.g. key symbol, keyway, bitting) and other special requirements. 4/5 6/7 8 9 10 11 12 13 EXAMPLE Line Item 1 2 3 Qty Product 24 4 60 ND10S ND50RD ND93PD Outside Des Fin SPA 605 RHO 613 ATH 626 Inside Des Fin Door Thickness 10-013 214 Hand Latch Strike Ext Additional Details EE 138 14-047 Note: Schlage order forms are available at no charge at www.schlage.com/pricing/pricing.htm. 12 Dim C145 245793 E 000000 13 14 15 Ingersoll Rand’s Security Technologies Sector is a leading global provider of products and services that make environments safe, secure and productive. The Sector’s market-leading products include electronic and biometric access control systems; time and attendance and personnel scheduling systems; mechanical locks and portable security, door closers and exit devices, steel doors and frames, architectural hardware and technologies and services for global security markets. www.schlage.com www.ingersollrand.com © 2006 Ingersoll Rand Company Limited Pub No. MS-M/ND Rev. 07/06