Download Nd-Series - Serrubec

Transcript
ND-Series
A New Standard In Grade 1 Security
Extra Heavy Duty Commercial
INDEX
ND-Series locks are for commercial, institutional and industrial
use, such as schools, hospitals and factories, where a long life of
dependable operation must be combined with a high degree
of resistance to physical abuse.
Popular functions of all lever designs are also available in
Vandlgard , where levers are free-wheeling in the locked
position to resist more forceful attacks.
®
Performance Features
Tested to exceed 3,000,000 cycles, greatly exceeding the 800,000 cycle ANSI
Grade 1 requirement.
Cylinders
8
Designs & Finishes
4
Door Preparation
3
Door Handing
12
Exploded View
2
Functions
6-7
How to Order
13
Interchangeable Cores
8-9
Latches
10
Performance Features
2
Specifications
3
Strikes
11
®
Exceeds ANSI A156.2 Series 4000 Grade 1 locked lever torque requirements.
Vandlgard Features
Vandlgard® functions have free-wheeling levers to resist force when locked.
Wiring for Electrified Locks
5
12
Independent heavy duty spring cages for effective lever support.
Thru-bolted mechanism for positive interlock to door.
Concealed mounting screws.
Steel Latchbolt.
Exploded View
Outside lever
Rose
Outside Spring Cage Assembly
Chassis
Adjusts for 1 5/8˝ - 2 1/8˝ thick doors
Push-Turn Button (Certain Function)
Provides visible locking status
Cylinder
6-Pin Everest Standard
Anti-rotation Plate
Inside Spring Cage Assembly
Integrated spindle/springcage reduces lever
wobble and droop
Latch Screws
Springcage Screws
Rose
Inside Lever
Latch
1/2˝ Throw
Strike
2
Strike Screws
On our cove r, the ND-Series OMEGA in Satin Nickel.
Specifications
Certifications
Handing:
All ND-Series lever locksets are non-handed.
ANSI
Meets or exceeds A156.2 Series 4000, Grade 1 strength
and operational requirements. Meets A117.1
Accessibility Code.
Door Thickness:
1⅝˝ to 2⅛˝ (41mm–54mm) standard including
Vandlgard® functions. 1¾˝ - 2˝ for function D85.
See accessories (Page 11) for spacers required
for 1³ ⁄ 8 ˝ doors.
Federal
Meets FF-H-106C Series 161.
California State Reference Code (CSFH)
Backset:
2³⁄₄˝ (70 mm) standard. 2³ ⁄ 8 ˝, 3¾˝ and
5˝ (60 mm, 95 mm, 127 mm) optional.
( Fo rmerly Title 19, California State Fire Marshal Standard )
Faceplate:
Brass, bronze or stainless steel. 1⅛˝ x 2¼˝
(29 mm x 57mm) square corner, beveled.
M E A Certification
All electrified locking (fail-safe, unlocked by switch or
power failures) functions accepted for use in New York
City by the City of New York, Department of Buildings
(MEA 24-04-E).
Lock Chassis:
Zinc plated for corrosion resistance.
Latch Bolt:
Steel, ½˝ (12mm) throw, deadlocking on keyed and
exterior functions. ³⁄₄˝ (19 mm) throw anti-friction latch
available for pairs of fire doors.
Exposed Trim:
Levers: Pressure cast zinc, plated to match finish symbols.
Roses: Solid brass.
Strike:
ANSI curved lip strike 1¼˝ x 4⅞˝ x 1³⁄₁₆˝ lip to center
standard. Optional strikes, lip lengths and ANSI strike
box available. See page 12.
All levers with less than ½˝ (64mm) returns comply;
levers return to within ½˝ of door face.
All levers with less than ½˝ (64mm) returns comply with
California Fire Safety Codes.
3/4˝ and 1/2˝ throw latch approved for Hurricane
Resistance with Miami-Dade County, Florida and
the Florida Building Commission.
UL / cUL:
All locks listed for A label single doors, 4´ x 8´.
Letter F and UL symbol
Cylinder & Keys:
6-pin Everest C123 keyway standard with two patented
nickel silver keys per lock.
Keying Options:
Interchangeable core and Primus® high security cylinders.
Master keying, grand master keying and construction
keying.
Warranty:
Seven-year limited for all functions including
Vandlgard®.
Door Preparation
Lever Designs
1-1/8" 2-3/4"
29mm 70mm
2-1/4"
57mm
1" dia
25mm
5/16" dia.
8mm
2-3/4"
70mm
2-1/8"
54mm
3
Lever Designs & Finishes
Lever Designs & Finishes
ATHENS
Symbol: ATH (L-Series 07)
Material: Pressure cast
zinc lever; wrought brass rose
Finishes:
605, 606, 612,
613, 619, 625,
626
SPARTA
Symbol: SPA (L-Series 17)
Material: Pressure cast
zinc lever; wrought brass rose
Finishes:
605, 606, 612,
613, 619, 625,
626
626
606
RHODES
Symbol: RHO (L-Series 06)
Material: Pressure cast
zinc lever; wrought brass rose
Finishes:
605, 606, 612,
613, 619, 625,
626
OMEGA
Symbol: OME (L-Series Omega)
Material: Pressure cast
zinc lever; wrought brass rose
Finishes:
605, 606, 612,
613, 619, 625,
626
612
619
TUBUL AR (L-Series 03)
Symbol: TLR
Material: Pressure cast
zinc lever; wrought brass rose
Finishes:
605, 606, 612,
613, 619, 625,
626
605
Bright Brass
606
Satin Brass
612
Satin Bronze
613
Oil Rubbed
Bronze
626
Keyed functions available with Full Size Interchangeable Core options.
619
Satin Nickel
625
Bright Chromium
Plated
Keyed functions available with Smal l Format Interchangeable Core options.
*
TACTILE WARNING
(KNURLING)
Change symbol designation as follows:
8AT for Athens
8RO for Rhodes
8SP for Sparta
8TR for Tubul ar*
*Only available with Tubular lever.
Only outside lever is knurled unless
otherwise specified.
4
Extended Factory Lead Time
Not available with Omega trim
Finishes
605 Bright Brass
606 Satin Brass
612 Satin Bronze
613 Oil Rubbed Bronze
619 Satin Nickel
625 Bright Chromium Plated
626 Satin Chromium Plated
626
Satin Chromium
Plated
ND-SERIES VANDLGARD
™
WIT H
Schlage ND-Series keyed lever locks with Vandlgard provide vandal resistant technology.
Designed for maximum accessibility, security and durability, Vandlgard sets the standard for
door hardware in educational facilities and other applications subject to heavy traffic or abuse.
The unique features of Vandlgard prevent damage to internal lock components caused by
excessive force from persons kicking, hitting or standing on the lever to gain access. Vandlgard
functions maintain total key system and architectural design compatibility with Schlage’s
regular ND-Series cylindrical locks.
Levers have virtually replaced knobs in the marketplace for handicap accessibility. The added
grip and leverage has created an increased opportunity for abuse or vandalism. This abuse often
renders locks inoperable. In some cases the security of the door is violated leaving computer and
laboratory equipment susceptible to theft. While this type of abuse is commonly associated with
junior and senior high schools, it also occurs in universities, office buildings, commercial
buildings, and public buildings.
Locked lever freely
rotates up and down while
remaining securely locked.
The Vandlgard function also
increases resistance to
over-rotation of the lever.
Benefits & Features
Superb warranty.
All Vandlgard functions have a 7-year warranty.
Reduce lever wobble and play.
Integrated spindle and spring cage greatly reduces lever sag and wobble.
Resists vandalism.
Free-wheeling lever eliminates the ability to stand or exe rt excessive force on the end of the leve r.
Ease of installation.
Installs in under 2 minutes.
Inner spindle operates
independently of lever when locked
ND-Series Vandlgard levers comply with ADA requirements.
5
Functions
ANSI A156.2 Series 4000 Grade 1
Non-Keyed Locks
Keyed Locks
SCHLAGE
ANSI
SCHLAGE
ANSI
ND10S
F75
Passage Latch
Both levers always unlocked.
ND50PD
F82
Entrance/Office Lock †
Push-button locking. Push-button
locks outside lever until unlocked
with key or by turning inside lever.
ND12D
F89
Exit Lock
Outside lever always fixed. Inside
lever always unlocked.
ND53PD
F109
Entrance Lock †
Turn/push-button locking; pushing
and turning button locks outside lever,
requiring use of key until button is
manually unlocked. Push-button
locking; pushing button locks outside
lever until unlocked by key or by
turning inside lever.
ND60PD
F88
Vestibule Lock †
Latch retracted by key from outside
when outside lever is locked by key in
inside lever. Inside lever is always
unlocked.
ND66PD
F91
Store Lock † *
Key in either lever locks or unlocks
both levers.
ND70PD
F84
Classroom Lock †
Outside lever locked and unlocked by
key. Inside lever always unlocked.
ND73PD
F90
Corridor Lock †
Locked or unlocked by key from
outside. Push-button locking from
inside. Turning inside lever or closing
door releases button. When outside lever
is locked by key it can only be unlocked
by key. Inside lever is always unlocked.
ND12DEL
Electrically Locked (Fail Safe)
Outside lever continuously locked
electrically. Unlocked by switch or
power failure. Auxiliary latch
deadlocks latchbolt when door is
closed. Inside lever always free for
immediate exit.
ND12DEU
Electrically Unlocked (Fail
Secure)
Outside lever continuously locked
until unlocked by electric current.
Auxiliary latch deadlocks latchbolt
when door is closed. Inside lever
always free for immediate exit.
ND25D
ND40S
ND44S
ND170
Exit Lock
Blank plate outside. Inside lever
always unlocked.
F76
Bath/Bedroom Privacy Lock
Push-button locking. Can be opened
f rom outside with small screwdriver.
Turning inside lever or closing door
releases button.
Hospital Privacy Lock
Push-button locking. Unlocked
f rom outside by turning emergency
turn-button. Turning inside lever or
closing door releases button.
Single Dummy Trim
Dummy trim for one side of door.
Used for door pull or as matching
inactive trim.
Safe School Locks
6
ND75PD
Classroom Security Lock †
Key in either lever locks or unlocks
outside lever. Inside lever is always
unlocked.
† Keyed functions available with 6-pin (PD/LD),
SFIC(GD/BD), or FSIC(RD/JD) cylinder.
* Caution: Double cylinder locks on residences and any
door in any structure which is used for egress are a life
safety hazard in times of emergency and their use is not
recommended. Installation should be in accordance with
existing codes only.
Functions
ANSI A156.2 Series 4000 Grade 1
Vandlgard Functions
Keyed Locks
SCHLAGE
ANSI
SCHLAGE
ANSI
ND91PD
F82
ND80PD
F86
ND92PD
F109
ND93PD
F88
ND94PD
F84
ND80PDEL
Electrically Locked (Fail Safe) †
Outside lever continuously locked
electrically. Unlocked by key outside
or by switch or power failure.
Auxiliary latch deadlocks latchbolt
when door is closed. Inside lever
always free for immediate exit.
Electrically Unlocked (Fail
Secure) †
Outside lever continuously locked
until unlocked by key or electric
current. Auxiliary latch deadlocks
latchbolt when door is closed. Inside
lever always free for immediate exit.
ND80PDEU
ND82PD
Storeroom Lock †
Outside lever fixed. Entrance by key
only. Inside lever always unlocked.
F87
ND85PD
Institution Lock † *
Both levers fixed. Entrance by key in
either lever.
Faculty Restroom Lock **
Outside lever fixed. Entrance by key
only. Push-button in inside lever
activates visual “occupancy”
indicator, allowing only emergency
master key to operate. Turning inside
lever or closing door releases visual
occupancy indicator. Rotation of
inside spinner-button provides
lock-out feature by keeping indicator
thrown.
ND95PD
ND96PD
ND96PDEL
Safe School Locks
† Keyed functions available with 6-pin (PD/LD),
SFIC(GD/BD), or FSIC(RD/JD) cylinders.
* Caution: Double cylinder locks on residences and any
door in any structure which is used for egress are a life
safety hazard in times of emergency and their use is not
recommended. Installation should be in accordance with
existing codes only.
** 85 function locks are not available in Full Size
& Small Format Interchangeable Cores.
ND96PDEU
Entrance/Office Lock †
Push-button locking. Push-button
disengages outside lever until
unlocked with key or by turning
inside lever. Vandlgard is designed to
disengage outside spindle from latch
when in locked condition.
Entrance Lock †
Turn/push-button locking; pushing
and turning button disengages outside
lever, requiring use of key until button
is manually unlocked. Push-button
locking; pushing button disengages
outside lever until unlocked by key or
by turning inside lever. Vandlgard is
designed to disengage outside spindle
f rom latch when in locked condition.
Vestibule Lock †
Latch retracted by key from outside
when outside lever is disengaged by
key in inside lever. Inside lever is
always unlocked. Vandlgard is
designed to disengage outside spindle
f rom latch when in locked condition.
Classroom Lock †
Outside lever disengaged and
unlocked by key. Inside lever always
unlocked. Vandlgard is designed to
disengage outside spindle from latch
when in locked condition.
Classroom Security Lock †
Key in either lever locks or unlocks
outside lever. Inside lever is always
unlocked.
F86
Storeroom Lock †
Outside lever always disengaged.
Entrance by key only. Inside lever
always unlocked. Vandlgard is
designed to disengage outside spindle
f rom latch when in locked condition.
Electrically Locked (Fail Safe) †
Outside lever continuously
disengaged electrically. Unlocked by
key outside or by switch or power
failure. Auxiliary latch deadlocks
latchbolt when door is closed. Inside
lever always free for immediate exit.
Vandlgard is designed to disengage
outside spindle from latch when in
locked condition.
Electrically Unlocked (Fail Secure) †
Outside lever continuously disengaged.
until unlocked by key or electric
current. Auxiliary latch deadlocks
latchbolt when door is closed. Inside
lever always free for immediate exit.
Vandlgard is designed to disengage
outside spindle from latch when in
locked condition.
7
Standard Cylinders
Full Size Interchangeable Core
Schlage® locks are provided with cylinders precision built to
extremely close tolerances and the highest standards of accuracy.
Using only solid brass plugs, extruded brass shells, phosphor
bronze springs, nickel silver keys and pins, ensures long life
and ease of operation. For complete listing of cylinder parts,
refer to the New ND-Series Service Manual (SC-2058).
Schlage® f igure-8 interchangeable core (IC) locksets allow
immediate rekeying at the door simply by using a special
control key to replace the core.
Conventional cylinders are available in Classic keyways or
in patented Everest® keyways. Specify keyway to differentiate
between Everest and Classic.
Example: C (Classic) vs. C123 (Everest).
Primus® High Security Cylinders
Primus high security cylinders are available to add patented key
control and varying degrees of geographical exclusivity to most
Schlage 6-pin key systems, whether Everest or Classic keyways.
In addition to a conventional pin tumbler mechanism, Primus
cylinders incorporate a patented finger pin and sidebar design
providing a “dual-locking” cylinder that is virtually pickproof. Resistance to drilling and other physical attack is
optional by specifying 20-500 Series UL437 Listed cylinders.
Classic Primus cylinders are recommended for upgrading
existing Classic key systems. Due to its extended patent life, the
newly designed Everest Primus is recommended for new key
systems and for upgrading existing Everest® key systems.
Specify keyway to differentiate between Everest and Classic.
Example: CP (Classic) vs. C123 (Everest).
Available in all lever designs, full size interchangeable cores
can be integrated into any 5 or 6-pin Schlage key.
To order complete locks with full size cores, change suffix
f rom PD to RD. Example: ND53RD. To order locks l ess core,
change suffix to JD. To order with full size construction core,
change suffix to T D.
Full Size Interchangeable Cores*
Number
Description
23-030
Conventional core
20-740
Primus high security core
Cylinder for Most Functions
*Available 606 and 626 finish only. Everest C123 keyway standard.
Driver
N123-127
Tailpiece is vertical (shown) for
levers.
Standard Cylinders*
Levers
Description
23-065
6-Pin conventional (standard)
20-765
Primus high security
20-565
Primus UL437 Listed high security
23-000
Hotel cylinder
N123-042
Temporary construction plug, plastic for functions
*Available in 606 and 626 finish only. Everest C123 keyway standard.
8
Small Format Interchangeable Core
Available in all lever designs, the small format IC
option is designed for Schlage Everest® B Family Restricted
keyway cores and is also completely compatible with Best®,
Falcon®, and other small format interchangeable cores.
To order complete locks with Everest B Family Restricted
keyway cores, change product suffix from PD to GD
and provide letter of authorization from end user.
Example: ND53GD. To order locks less core,
change suffix to BD. To order with keyed brass construction
cores, change suffix to HD. To order with disposable plastic
construction cores, change suffix to BDC.
Small Format Core
Disposable Construction Core
N523-091
Small Format Interchangeable Cores
Number
Description
80-036
7-Pin uncombinated Everest B Family Restricted keyways
80-037
7-Pin combinated Everest B Family Restricted keyways
80-043
6-pin uncombinated Falcon / Best keyways
80-033
7-pin uncombinated Falcon / Best keyways
M204-152*
N523-091
Disposable plastic construction core
SFIC Driver
Available 606 and 626 finish only. Specify keyway for existing systems.
80-033 and 80-043 cores are available in Best A, D, E, F, G, H, J, K, L, and M
keyways. Specify keyway by suffixing “B” to keyway letter, e.g. “AB”.
80-036 and 80-037 Restricted keyway cores require a letter of authorization
f rom the end user. Schlage assigns the keyway when establishing new
Everest Restricted key systems.
*M204-152 does not have a finish option.
9
Latches
ND-Series latches are adjustable for flat or beveled edge doors.
Latches and strikes are furnished in brass, bronze, or chrome
f inishes to be compatible with lock trim. When ordering,
specify quantity, part number, and finish. All ND-Series latches
have ½˝ throw and 1˝ housings except 2⅜˝ backset latches,
which includes sleeve G506-815 to fill a 1˝ edge bore.
Standard latches are shown in bold type.
Long Backsets
ND-Series locks with 5˝ backsets are normally furnished with
1⅛˝ faceplates and 1˝ housings. Links installed in metal doors
require one A501-567 sleeve and 43-005 (order separately) to
join latch and link.
2-3/4˝ Latch
Latches
2³⁄₄˝
70mm
(add to 2 ³⁄₄”
backset
latch)
Deadlatch Springlatch
¹⁄₂˝ Throw ¹⁄₂˝ Throw
Description
1¹⁄₈˝ (29mm) x 2¹⁄₄˝ (57mm) square corner
1” (25mm) x 2¹⁄₄˝ (57mm) square corner
1¹⁄₈" (29mm) x 2¹⁄₄" (57mm) square corner
1¹⁄₈˝ (29mm) x 2¹⁄₄˝ (57mm),
14-047
14-048
13-047
14-042
–
–
13-048
_
14-028
14-010
³⁄₄˝ (19mm) throw for pairs of fire doors
3 ³⁄₄˝
95mm
Sleeve (A501-567)
(43-005)
Backset
2³⁄₈˝
60mm
Extension
Link
1¹⁄₈˝ (29mm) x 2¹⁄₄˝ (57mm) Square corner
Deadlatch
Springlatch
Door Reinforcement
Schlage 37-001 reinforcing kit is used to
reinforce and help prevent the collapse of
hollow metal doors when locksets are
tightly mounted.
This kit should be used with long backsets for ND-Series
lock installations in hollow metal doors to prevent lateral
movement of the latchbolt. Specify door thickness,
1⅜˝or 1¾˝, when ordering reinforcement kits.
³⁄₄” Throw Anti-Friction Deadlatch for Pairs of Fire Doors
Reinforcement Kit
(37-001)
Sleeve
(A501-567)
G506-815
Reinforcement
13/4˝ doors (A501-566) or
13/8˝ doors (A501-565)
ANSI Strike–Standard
Square Corner Box Strike
(10-025)
(10-013)
1 1/4˝ x 4 7/8˝ x 3/32˝
1 1/8˝ x 2 3/4˝ x 3/32˝
Strikes
All Schlage strikes are furnished complete with screws.
The standard ND-Series strike has a 1³⁄₁₆˝ lip.
When ordering separately specify quantity, product number,
f inish, and lip length. Standard strikes are shown in bold type.
Strikes
Number
Lip Length
10-013
1 1/8˝ (28mm)
1 1/8˝ x 2 3/4˝ (28mm x 70mm) Square corner, box
1 3/4˝ (38mm)
10-016
1 1/8˝ (28mm)
1 1/8˝ x 2 3/4˝ (28mm x 70mm), 3/4˝ (19mm) deep
box for 14-042 fire door latch
10-025
1 3/16˝ (30mm)
1 3/8˝ (35mm)
1 1/4˝ x 4 7/8˝ (32mm x 124mm) ANSI
K510-066
—
10
Description
Box for 10-025 ANSI strike
Rabbeted Latch and Strike Kit
Rabbeted latch and strike kit finishes: 605, 626.
This kit adapts square corner latches and 2 3/ 4˝ (28mm) high
strikes for ½˝ (13mm) rabbeted door and frame preparations.
Rabbeted Latch
and Strike Kit
(39-030)
Typical Wiring Diagram for Electrified Locks
Door Handing
AC Power Source – EL or EU
All Schlage® locks are reversible. Hand information is
necessary to ensure proper finish of latchbolt and strike
for split-finish locks. Fo l l ow the diagram to determine
the hand of the door. The outside is the secure side or the
corridor side.
AC Operation
Switch
(Not Furnished)
Rectifier
To Lock
Transformer
(Not Furnished)
24V AC
115V AC
Plug
LH
Left Hand
INSIDE
RH
Right Hand
Rectifier used on AC operation unit only.
.35A @ 24V (Current requirements per lock)
OUTSIDE
INSIDE
DC Power Source – EL or EU
DC Operation
Switch
(Not Furnished)
24V DC
LRB
Left Hand
Reverse Bevel
OUTSIDE
RRB
Right Hand
Reverse Bevel
To Lock
.15A @ 24V (Current requirements per lock)
AC and DC Application
Cut as close to plug as
possible for DC operation.
Plug into solenoid
for AC operation.
Discard for DC operation.
Solenoid
Rectifier
Accessories
1-3/ 8˝ D-Series Lever Door Spacer*
XN12-012
*For installation on 1 ³⁄₈” doors, two (2) spacers are required. Specify finish.
11
How to Order ND-Series Levers
To order Schlage® products, descriptive data should be in the same sequence as shown.
Line
Item
1
1
2
3
Qty
Product
2
3
Outside
Des Fin
4
5
Inside
Des Fin
6
7
Hand
8
Latch Strike
9
10
Door
Thickness
11
Ext
Dim
Additional Details
12
13
14
Line item number
Quantity
Complete model number with function and cylinder type
To order cylinder options, change “PD” at the end of the model number as follows:
ND53PD Standard.
ND53LD Less standard cylinder. For Primus® cylinder, specify this option and order Primus cylinder separately.
ND53CD With temporary plastic construction cylinder. Double cylinder functions ordered less cylinder are
furnished with these construction cylinders to maintain timing of key cams.
ND53JD Prepared for full size interchangeable core, less core. For Primus core, specify this option and order
Primus core separately.
ND53RD With full size conventional interchangeable core installed. Order control keys separately.
ND53T D With full size (temporary) construction core installed. Order all keys separately.
ND53BD Prepared for small format (Falcon®, Best®, etc.) interchangeable core (SFIC), less core.
ND53GD With Everest® B Family restricted keyway small format core installed. Order control keys separately.
ND53HD With small format keyed brass construction core installed. Order all keys separately.
ND53BDCWith small format disposable plastic construction core installed.
Outside design / finish. Specify tactile warning (knurling) here as “8AT” for Athens®, “8RO” for Rhodes® or “8SP”for Sparta®.
Inside design / finish. Leave blank if same as outside.
Hand. Required for keyed knob designs and all split finish locksets. One hand per line item.
Latch. Leave blank for standard or specify part number for optional latch. LLL=Less Latch.
Strike. Leave blank for standard or specify part number for optional strike. LLL=Less Strike.
Door thickness, if non-standard. Example: 200 = 2˝.
Extension, to specify whether thick door is extended inside (EI), outside (EO), differently (ED) or equally (EE).
Dimension for strike lip lengths. See strike page for availability of specific dimensions with specific strikes.
100 = 1˝
118 = 1⅛˝
114 = 1¼˝
138 = 1⅜˝
112 = 1½˝
134 = 1¾˝
200 = 2˝
14 Keying detail (e.g. key symbol, keyway, bitting) and other special requirements.
4/5
6/7
8
9
10
11
12
13
EXAMPLE
Line
Item
1
2
3
Qty
Product
24
4
60
ND10S
ND50RD
ND93PD
Outside
Des Fin
SPA 605
RHO 613
ATH 626
Inside
Des Fin
Door
Thickness
10-013
214
Hand Latch Strike
Ext
Additional Details
EE
138
14-047
Note: Schlage order forms are available at no charge at www.schlage.com/pricing/pricing.htm.
12
Dim
C145 245793
E 000000
13
14
15
Ingersoll Rand’s Security Technologies Sector is a leading global provider of products and services that make environments safe,
secure and productive. The Sector’s market-leading products include electronic and biometric access control systems; time and
attendance and personnel scheduling systems; mechanical locks and portable security, door closers and exit devices, steel
doors and frames, architectural hardware and technologies and services for global security markets.
www.schlage.com www.ingersollrand.com
© 2006 Ingersoll Rand Company Limited
Pub No. MS-M/ND Rev. 07/06