Portable Air Conditioner
SVC MANUAL(Exploded View)
MODEL : GP120CE(TWC121ZBMM0)
CAUTION
Before Servicing the unit, read the safety precautions in Standard SVC manual.
Only for authorized service personnel.
1. Specification
Models
Cooling Capacity
Heating Capacity
Electric Heater Capacity
Power Input
Cooling/Heating
Running Current
Cooling/Heating
Starting Current
Cooling/Heating
Electric Heater Current
EER
COP
Power Supply
Power Factor
Air Flow Rate
Moisture Removal
Sound Level
Refrigerant & Charge
Compressor
Fan
Power Supply Cable
Dimension
Net Weight
Tool Code(Chassis)
Functions
Type
Model
Motor Type
Oil Type
Oil Charge
O.L.P Name
Type(In/Out)
Motor Type
Motor Output
W*H*L
Indoor
kW
Btu/h
kW
Btu/h
kW
Btu/h
W
A
A
A
W/W
Btu/h.W
W/W
Ø / V / Hz
%
cmm(cfm)
l/h
dB(A)+3
g(oz)
cc
W
No.*mm2
mm
kg
Temperature Control
Energy Saver Switch
Prefilter(washable/anti-fungus)
Plasma Filter
Steps, Fan/Cool/Heat
Airflow Direction Control(up&down)
Airflow Direction Control(left&right)
Remocon Type
Setting Temperature
Cooling
Range
Heating
Auto Operation (Micom Control)
Panel Touch Type
Timer
Air Discharge
Air Ventilation
Deice Control(Defrost)
Hot Start
Look
Cabinet Type(Chassis Type)
Special Function
GP120CE
3.52
12,000
1,300
11
2.71
9.20
1Ø / 115V / 60Hz
97.1
7.0(247)
2.8
55/53/51
R22,500(17.7)
Rotary(Non Tropical)
K1-C176ABBC-A
PSC
SUNISO 4GSI(or NM56m)
315
MRA12151-12027
Blower/Blower
AC Induction
50/135
3*2.1(AWG 14)
500*840*350
33
WZ
Thermistor
O
O
3/3/Wireless simple
60˚F~86˚F(16˚C~30˚C)
Micom
24h, On/Off
Inclinded and Top
B-Look
-
Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.
Some of functions are slightly different depending upon models.
The specification may be subject to change without notice for purpose of improvement.
2 Portable Air Conditioner
Copyright 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes.
LGE Internal Use Only
2. Piping Diagrams
Capillary Tube
Heat
Exchanger
(Condenser)
Heat
Exchanger
(Evaporator)
Accumulator
Compressor
Service Manual 3
3. Wiring Diagrams
CNWT
COMP
CNPT
CNRT
CNRCV
CNDISP
DOWN SWING CN-WAT
FAN
4 Portable Air Conditioner
UPER
FAN
4. Exploded View
359012B
346810B
731270
146811
352380A
354210
147582A
359012C
435300
131111
147582B
152500B
264110
145200A
152302
235512
135515
W0CZZB
346810A
W50060C
152500A
261704
268711B
268711A
W0CZZC
359012A
352380B
567480
135312
349011
267120
554030
346811
554160
266001
552101
145200B
35211A
352113
130410
352390
W50060B
147581
W50060A
135511
W0CZZA
267110
144410
148000
Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://biz.Lgservice.com,)
Service Manual 5
P/NO : MFL38891311
JANUARY, 2008