Download MODEL TR - 25A

Transcript
MOHAWK MODEL TR - 25A
New Slab Recommendations
File: New-slab.xls
Rev Date: 10/12/01
NEW SLABS MUST BE 12" THICK MINIMUM !!
W
Lift Model
L
Slab Width, Slab Length,
R
S
D
I
Reinforcement
Reinforcement
Wej-it
Wej-it
(Feet)
(Feet)
Size, (Inch)
Spacing, (Inch)
Dia, (Inch)
Length, (Inch)
A-7
4'
14'
#3 (3/8") *
8"
3/4"
5 1/2"
Tomahawk
4'
14'
#3 (3/8") *
8"
3/4"
5 1/2"
System IA
4'
14'
#3 (3/8") *
8"
3/4"
5 1/2"
LMF-12
6'
15'
#3 (3/8") *
8"
3/4"
6 1/4"
TP-15
6'
15'
#3 (3/8") *
8"
3/4"
6 1/4"
TP-18
6'
16'
#3 (3/8") *
8"
3/4"
6 1/4"
TP-20
6'
16'
#3 (3/8") *
8"
3/4"
6 1/4"
TP-26
N/A**
N/A**
N/A**
N/A**
N/A**
N/A**
TP-30
N/A**
N/A**
N/A**
N/A**
N/A**
N/A**
TR-19****
2'
2'
N/A***
N/A***
3/4"
5 1/2"
FL-25****
2'
2'
N/A***
N/A***
3/4"
5 1/2"
TR-25****
2'
2'
N/A***
N/A***
3/4"
5 1/2"
TR-33****
6'
6'
N/A***
N/A***
3/4"
5 1/2"
TR-35****
6'
6'
N/A***
N/A***
3/4"
5 1/2"
TR-50****
6'
6'
N/A***
N/A***
3/4"
5 1/2"
TR-75****
6'
6'
N/A***
N/A***
3/4"
5 1/2"
*
An Acceptable Alternative is to use 4 x 4 Wire Mesh at same specified location.
**
See Subframe Installation Instructions
*** No Reinforcement Required (4 x 4 Wire Mesh Recommended)
**** Four Separate Slabs Formed at each Post.
53