Download "service manual"

Transcript
• Outdoor Units • R-410A • REQ-B7
TABLE OF CONTENTS
REQ-B7
1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
4
5
8
3
Options
4
Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . .
10
Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
5
Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
6
Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound power spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
7
8
9
.......... ........... .......... .......... .......... .......... . 9
10
15
16
Installation method
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Operation range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
• Split Sky Air • Outdoor Units
1
• Outdoor Units • R-410A • REQ-B7
o a7t o B0 i d 1- l t4Q puE- SR1
O
1
•
Outdoor units for pair and twin application
•
•
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
•
The sevice valves are hidden inside the casing.
•
Outdoor units are fitted with a scroll compressor, renowned for low
noise and high energy efficiency.
•
A special acryl precoated fin for anti-corrosion treatment on the heat
exchanger ensures greater resistance against severe weather
conditions
1
1
Features
• Split Sky Air • Outdoor Units
The piping connections can be accessed from underneath, front, side
or rear.
• Outdoor Units • R-410A • REQ-B7
2
Specifications
3
2-1 TECHNICAL SPECIFICATIONS
Casing
Dimensions
Colour
Material
Packing
Unit
Weight
Heat
Exchanger
Fan
Motor
Fan
Motor
Fan
Compressor
Oper ation
Range
Sound Level
(nominal)
Height
Width
Depth
Height
Width
Depth
mm
mm
mm
mm
mm
mm
kg
kg
mm
Machine Weight
Gross W eight
Dimensions
Length
Nr of Rows
Fin Pitch mm
Nr of Passes
Face
m²
Area
Nr of Stages
Tube type
Fin
Type
Treatment
Type
Discharge direction
Quantity
Air Flow Rate Cooling
m³/min
(nominal)
Heating
m³/min
Motor
Quantity
Model
Position
Speed
Steps
(nominal at
230V)
Motor
Output
W
Drive
Position
Speed
Steps
(nominal at
230V)
Motor
Output
W
Drive
Quantity
Motor
Model
Type
Motor
W
Output
Starting Method
Crankcas W
e Heater
Cooling
Min
°CDB
Max
°CDB
Heating
Min
°CWB
Max
°CWB
Cooling
Sound
dBA
Power
Sound
dBA
Pressure
R EQ71B7 V3 B
REQ7 1B7W1 B
R EQ100B 7V3B
900
980
420
770
900
320
83
87
857
2
2.00
6
0.641
900
980
420
770
900
320
83
87
857
2
2.00
6
0.641
Daikin W hite
Painted galvanized steel plate
1300
980
420
1170
900
320
102
107
857
2
2.00
10
0.980
34
34
1
48.0
43.0
1
1
48.0
43.0
1
3
3
65
65
REQ1 00B7W1B
REQ125B7 W1B
2
1300
980
420
1170
900
320
100
105
857
2
2.00
10
0.980
1300
980
420
1170
900
320
108
113
857
2
2.00
10
0.980
52
52
1
55.0
50.0
1
2
89.0
80.0
1
3
3
Lower
3
90
direct drive
90
85
52
Hi-XSS cooling tube
Non- symmetric waffle louvre
Anti-corrosion tr eatment (PE)
Direct Drive Propeller
Hor izontal
1
55.0
50.0
1
P47L11S
1
Upper
3
1
JT90G- V1N
2200
1
1
1
JT90G-YE
JT125G-V1N
JT125G-YE
Hermetically sealed scroll compressor
2200
3000
3000
65
dir ect drive
1
JT160G -YE
3750
33
33
Dir ect
33
33
33
10.0
46.0
-10.0
15.0
65.0
10.0
46.0
-10.0
15.0
65.0
10.0
46.0
-10.0
15.0
70.0
10.0
46.0
-10.0
15.0
70.0
10.0
46.0
-10.0
15.0
70.0
53.0
53.0
57.0
57.0
57.0
• Split Sky Air • Outdoor Units
2
• Outdoor Units • R-410A • REQ-B7
2-1 TECHNICAL SPECIFICATIONS
Refr iger ant
Refr iger ant Oil
1
2
Piping
connections
Type
Char ge
Control
Nr of Circuits
Type
Char ged Volume
Liquid (OD)
Quantity
Type
Diameter
(O D)
Gas
Quantity
Type
Diameter
(O D)
Drain
Quantity
Type
Diameter
(O D)
Piping Length Minimum
Maximum
Equivalen
t
Char gele
ss
Installation
Maximum
height
difference
Max. internunit level
difference
Heat Insulation
Defr ost Method
Defr ost Control
Capacity Contr ol Method
Safety Devices
Standard
Accessories
Notes
3
Item
Quantity
Item
Quantity
kg
REQ71B 7V3B
REQ71B7W1B
2.50
2.50
1
1
l
1.5
1
1.5
1
mm
9.52
9.52
1
1
15.9
15.9
3
3
mm
26
m
m
m
mm
REQ100 B7V3B
REQ100B7W1B
R-410A
3.60
Expansion valve ( electr onic type)
1
Daphne FVC68D
1.5
1
Flare connection
9.52
1
Flare connection
15.9
R EQ125B 7W1B
3.60
3.60
1
1
1.5
1
1.5
1
9.52
9.52
1
1
15.9
15.9
3
3
26
3
Hole
26
26
26
5
50
70
5
50
70
5
50
70
5
50
70
5
50
70
m
7.5
7.5
7.5
7.5
7.5
m
30.0
30.0
30.0
30.0
30.0
m
0.5
0.5
0.5
0.5
0.5
Both liquid and gas pipes
Reversed cycle
Sensor for outdoor heat exchanger temperature
None
Reverse phase protector
PC board fuse
Over cur rent relay (compressor)
Low pressure switch
High pr essur e switch
Fan motor thermal protector
Declar ation of conformity
1
1
1
1
1
Installation manual
1
1
1
1
1
Sound pressur e level is a r elative value, depending on the distance and acoustic environment. For mor e details,
please refer to sound level dr awings of this chapter.
The sound power level is an absolute value indicating the power which a sound source gener ates.
Sound values are measured in a semi- anechoic room.
In case of drain piping for outdoor unit, drain piping kit (option) is needed.
Nominal cooling capacities are based on : indoor temperature : 27° CDB, 19°CWB, outdoor temperature : 35° CDB,
equivalent refrigerant piping : 7.5m, level difference : 0m.
Nominal heating capacities are based on : indoor temperatur e : 20°CDB, outdoor temperature : 7°CDB, 6° CW B,
equivalent refrigerant piping : 7.5m, level difference : 0m
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B7
2-2 ELECTRICAL SPECIFICATIONS
Power Supply
Cur rent
Voltage range
Wiring
connections
Name
Phase
Frequency
Voltage
Z-max
Text
Recomended fuses
Minimum
Maximum
For Power
Quantity
Supply
Remark
For connection Quantity
with indoor
Remark
Power Supply Intake
Hz
V
A
V
V
R EQ71B7 V3 B
REQ7 1B7W1 B
V3
1
50
230
0,06+j0,04
32
207
253
1
3 wires (ear th wire
included)
1
W1
3N
50
400
0,35+j0,22
16
360
440
1
5 wires (earth wir e
included)
1
R EQ100B 7V3B
REQ1 00B7W1B
V3
W1
1
3N
50
50
230
400
0,04+j0,02
0,31+j0,19
40
16
207
360
253
440
1
1
3 wires (earth wire
5 wires (earth wire
included)
included)
1
1
4 wir es (earth wir e included)
Outdoor unit only
REQ125B7 W1B
W1
3N
50
400
0,26+j0,16
20
360
440
1
5 wires (earth wire
included)
1
3
1
2
NOTES
• Split Sky Air • Outdoor Units
4
• Outdoor Units • R-410A • REQ-B7
2-3
Electrical data
REQ71B7
Unit combination
Indoor unit
Outdoor unit
Hz-Volts
Power supply
Voltage range
Compressor
LRA
RLA
MCA
TOCA
MFA
16.6
23.3
32
75.5
16.8
23.2
32
17.4
23.5
OFM
IFM
kW
FLA
kW
FLA
12.2
0.065
0.6
0.045
0.7
75.5
12.5
0.065
0.6
0.062
0.6
32
75.5
12.7
0.065
0.6
0.125
0.9
FCQ71
REQ71B7V3B
50-230
1
FHQ71
REQ71B7V3B
50-230
2
FBQ71
REQ71B7V3B
50-230
FDEQ71
REQ71B7V3B
50-230
15.4
23.5
32
75.5
11.1
0.065
0.6
0.125
0.9
FCQ71
REQ71B7W1B
50-400/230
7.3
11.3
16
41.1
4.8
0.065
0.6
0.045
0.7
FHQ71
REQ71B7W1B
50-400/230
7.5
11.2
16
41.1
5.0
0.065
0.6
0.062
0.6
FBQ71
REQ71B7W1B
50-400/230
8.1
11.5
16
41.1
5.3
0.065
0.6
0.125
0.9
FDEQ71
REQ71B7W1B
50-400/230
6.8
11.5
16
41.1
4.2
0.065
0.6
0.125
0.9
Max. 50Hz-253V
Min. 50Hz-207V
Max. 50Hz-440/253V
Min. 50Hz-360/207V
3TW26599-9
MCA
TOCA
MFA
LRA
RLA
OFM
IFM
FLA
kW
5
:
:
:
:
:
:
:
:
:
SYMBOLS
Min. Circuit Amps
Total Over Current Amps
Max. Fuse Amps (see note 7)
Locked Rotor Amps
Rated Load Amps
Outdoor Fan Motor
Indoor Fan Motor
Full Load Amps
Rated motor output
• Split Sky Air • Outdoor Units
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.5°CWB
Outdoor temp. : 35°CDB
2. TOCA means the total value of each OC set
3. Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed
operation range limits
4. Maximum allowable voltage unbalance between phases is 2%.
5. MCA/MFA
MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA
(next lower standard fuse rating Min. 16A)
6. Select wire size based on the larger value of MCA or TOCA
7. Instead of fuse, use circuit breaker
8. For more details concerning conditional connections, see
http://www.daikineurope.com/extranet, select ’’Daikin
Documentation’’ and select ’’conditional connection’’, ’’the
requested product type’’ and ’’English’’ from the drop down
lists, click the search button.
Finally, click on the document title of your choice.
• Outdoor Units • R-410A • REQ-B7
REQ100B7
Unit combination
Indoor unit
Outdoor unit
Hz-Volts
Power supply
Voltage range
Compressor
LRA
RLA
MCA
TOCA
MFA
23.8
34.8
40
98.5
25.3
34.5
40
23.2
34.8
OFM
IFM
kW
FLA
kW
FLA
17.6
0.090
0.8
0.090
1.0
98.5
19.0
0.090
0.8
0.130
0.7
40
98.5
17.1
0.090
0.8
0.135
1.0
1
2
FCQ100
REQ100B7V3B
50-230
FHQ100
REQ100B7V3B
50-230
FBQ100
REQ100B7V3B
50-230
FDEQ100
REQ100B7V3B
50-230
24.2
34.8
40
98.5
17.9
0.090
0.8
0.135
1.0
FCQ100
REQ100B7W1B
50-400/230
9.2
11.8
16
48.2
5.9
0.090
0.8
0.090
1.0
FHQ100
REQ100B7W1B
50-400/230
9.4
11.5
16
48.2
6.3
0.090
0.8
0.130
0.7
FBQ100
REQ100B7W1B
50-400/230
8.9
11.8
16
48.2
5.7
0.090
0.8
0.135
1.0
FDEQ100
REQ100B7W1B
50-400/230
9.6
11.8
16
48.2
6.2
0.090
0.8
0.135
1.0
Max. 50Hz-253V
Min. 50Hz-207V
Max. 50Hz-440/253V
Min. 50Hz-360/207V
3
3TW26619-9
MCA
TOCA
MFA
LRA
RLA
OFM
IFM
FLA
kW
:
:
:
:
:
:
:
:
:
SYMBOLS
Min. Circuit Amps
Total Over Current Amps
Max. Fuse Amps (see note 7)
Locked Rotor Amps
Rated Load Amps
Outdoor Fan Motor
Indoor Fan Motor
Full Load Amps
Rated motor output
• Split Sky Air • Outdoor Units
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.5°CWB
Outdoor temp. : 35°CDB
2. TOCA means the total value of each OC set
3. Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed
operation range limits
4. Maximum allowable voltage unbalance between phases is 2%.
5. MCA/MFA
MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA
(next lower standard fuse rating Min. 16A)
6. Select wire size based on the larger value of MCA or TOCA
7. Instead of fuse, use circuit breaker
8. For more details concerning conditional connections, see
http://www.daikineurope.com/extranet, select ’’Daikin
Documentation’’ and select ’’conditional connection’’, ’’the
requested product type’’ and ’’English’’ from the drop down
lists, click the search button.
Finally, click on the document title of your choice.
6
• Outdoor Units • R-410A • REQ-B7
REQ125B7
Unit combination
Indoor unit
Outdoor unit
1
Hz-Volts
Power supply
Voltage range
MCA
TOCA
MFA
Compressor
LRA
RLA
OFM
IFM
kW
FLA
kW
FLA
FCQ125
REQ125B7W1B
50-400/230
12.4
15.3
20
63
8.1
0.065
+
0.085
0.6
+
0.7
0.09
1.0
FHQ125
REQ125B7W1B
50-400/230
12.3
15.0
20
63
8.2
0.065
+
0.085
0.6
+
0.7
0.13
0.7
2
Max. 50Hz-440/253V
Min. 50Hz-360/207V
FBQ125
REQ125B7W1B
50-400/230
12.2
15.7
20
63
7.6
0.065
+
0.085
0.6
+
0.7
0.225
1.4
FDEQ125
REQ125B7W1B
50-400/230
12.6
15.7
20
63
7.9
0.065
+
0.085
0.6
+
0.7
0.225
1.4
3TW26639-9
MCA
TOCA
MFA
LRA
RLA
OFM
IFM
FLA
kW
7
:
:
:
:
:
:
:
:
:
SYMBOLS
Min. Circuit Amps
Total Over Current Amps
Max. Fuse Amps (see note 7)
Locked Rotor Amps
Rated Load Amps
Outdoor Fan Motor
Indoor Fan Motor
Full Load Amps
Rated motor output
• Split Sky Air • Outdoor Units
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.5°CWB
Outdoor temp. : 35°CDB
2. TOCA means the total value of each OC set
3. Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above listed
operation range limits
4. Maximum allowable voltage unbalance between phases is 2%.
5. MCA/MFA
MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA
(next lower standard fuse rating Min. 16A)
6. Select wire size based on the larger value of MCA or TOCA
7. Instead of fuse, use circuit breaker
8. For more details concerning conditional connections, see
http://www.daikineurope.com/extranet, select ’’Daikin
Documentation’’ and select ’’conditional connection’’, ’’the
requested product type’’ and ’’English’’ from the drop down
lists, click the search button.
Finally, click on the document title of your choice.
• Outdoor Units • R-410A • REQ-B7
2-4
Safety device settings
3
REQ71~125B7
Model
Safety device
REQ71B7V3B
REQ100B7V3B
REQ71B7W1B
REQ100B7W1B
LPS
Max discharge temperature
Overcurrent relay
1
Off 135 ±5°C
Fan motor thermal protector
HPS
REQ125B7W1B
On 95 ±15°C
+0
0,10
Mpa
+0,15
- 0,15
Mpa
Off 4,15 On 3.2
+0,02
0,02
Off -0.03 -
2
Mpa
On 0.05 +0,03
- 0,03 Mpa
By thermistor and software control
By overcurrent sensor and software control
4TW26321-2B
• Split Sky Air • Outdoor Units
8
• Outdoor Units • R-410A • REQ-B7
3
1
3
Options
REQ71~125B7
Name of option
Central drain plug
Kit name
REQ71B7
REQ100B7
REQ125B7
KKPJ5F180
4TW26599-1
9
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B7
4
Dimensional drawing & centre of gravity
4-1
Dimensional drawing
3
unit (mm)
REQ71B7
Hole for anchor bolt
4-M12
1
2
3
4
5
6
7
8
Gas pipe connection J15.9 flare
Liquid pipe connection - J9.5 flare
Service port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake (knock hole J34)
Control wiring intake (knock hole J27)
Drain outlet
1
4
3TW26324-1
unit (mm)
REQ100B7
Hole for anchor bolt
4-M12
1
2
3
4
5
6
7
8
Gas pipe connection J15.9 flare
Liquid pipe connection - J9.5 flare
Service port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake (knock hole J34)
Control wiring intake (knock hole J27)
Drain outlet
3TW26344-1
• Split Sky Air • Outdoor Units
10
• Outdoor Units • R-410A • REQ-B7
unit (mm)
REQ125B7
1
2
3
4
5
6
7
8
Hole for anchor bolt
4-M12
1
Gas pipe connection J15.9 flare
Liquid pipe connection - J9.5 flare
Service port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake (knock hole J34)
Control wiring intake (knock hole J27)
Drain outlet
4
3TW26364-1
4-2
Centre of gravity
REQ71B7
Model
REQ71B7
A
267
3TW26329-5C
11
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B7
REQ100B7
3
1
4
Model
REQ100B7
A
390
3TW26349-5C
REQ125B7
Model
REQ125B7
A
390
3TW26369-5C
• Split Sky Air • Outdoor Units
12
• Outdoor Units • R-410A • REQ-B7
5
1
Piping diagram
REQ71~125B7 (Pair)
Electronic expansion
valve
Solenoid valve
5
One way valve
One way valve
One way valve
One way valve
Filter
Heat exchanger
Filter
Service
port 5/16†
Strainer
Receiver
Capillary tube
Heat exchanger
One way valve
4-way valve
Filter
High pressure
switch
Low pressure
switch
Muffler
Field piping J9.5 C122OT-O
Service
port 5/16†
Filter
Field piping J15.9 C122OT-O
Compressor
Indoor unit
Stop valve
(with service port 1/4 †flare)
Outdoor unit
Heating
Cooling
O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe
3TW26325-1
REQ71~125B7 (Twin)
Solenoid valve
Heat exchanger
Electronic expansion
valve
One way valve
One way valve
Filter
Heat exchanger
Filter
One way valve
Service
port 5/16†
Strainer
Field piping
Filter
One way valve
Receiver
Field piping
Capillary tube
Indoor unit
One way valve
4-way valve
Filter
Heat exchanger
Low pressure
switch
High pressure
switch
Muffler
Field piping J9.5
Service
port 5/16†
Branch pipe
(Option)
Field piping J15.9
Compressor
Field piping
Filter
Indoor unit
Field piping
Stop valve
(with service port 5/16 †flare)
Outdoor unit
O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe
13
• Split Sky Air • Outdoor Units
Heating
Cooling
3TW26325-2
• Outdoor Units • R-410A • REQ-B7
6
Wiring diagram
6-1
Wiring diagram
3
REQ71-100B7V3B
Power supply
1~50Hz
230V
A1P
BS1
C1R
C3R
DS1
E1HC
F1U
HAP
K1M
K1R
K2R
K3R
K4R
K5R,K6R,K7R
M1C
M1F
PC
Q1DI
Q1M
R1T
R2T
R3T
RC
S1PH
S1LP
SD
T1A
TC
X1M,X2M
Y1E
Y1S
Y2S
CT
Printed circuit board
Push button (forced defrost-pump down)
Capacitor (M1F)
Capacitor (M1C)
DIP switch
Crankcase heater
Fuse (T6.3/250V)
Light emitting diode (service monitor green)
Magnetic contactor (M1C)
Magnetic relay (K1M)
Magnetic relay (Y2S)
Magnetic relay (E1HC)
Magnetic relay (Y1S)
Magnetic relay (M1F)
Motor compressor
Motor fan
Power circuit
Earth leakage breaker (30mA)
Thermo switch (M1F)
Thermistor (air)
Thermistor (coil)
Thermistor (discharge pipe)
Signal receiver circuit
Pressure switch (high)
Pressure switch (low)
Safety devices input
Current transformer
Signal transmission circuit
Terminal strip
Expansion valve (electronic type)
4-way valve
Solenoid valve
Current transformer
1
Indoor
6
Outdoor
ON
OFF
Switch box
(Outdoor)
Position of
compressor
terminal
Note:
Wire
entrance
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g Field wiring
D : Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
2TW26326-1B
REQ71-100B7W1B
Switch box
(Outdoor)
Indoor
Outdoor
Power supply
3N~50Hz
400V
ON
Note:
OFF
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g Field wiring
D : Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Position of
compressor
terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
A1P
BS1
C1
DS1
E1HC
F1U, F2U
HAP
K1M
K1R
Printed circuit board
Push button (forced defrost-pump down)
Capacitor (M1F)
DIP switch
Crankcase heater
Fuse (T6.3/250V)
Light emitting diode (service monitor green)
Magnetic contactor (M1C)
Magnetic relay (K1M)
Wire
entrance
K2R
K3R
K4R
K5R,K6R,K7R
M1C
M1F
PC
Q1DI
Q1M
Magnetic relay (Y2S)
Magnetic relay (E1HC)
Magnetic relay (Y1S)
Magnetic relay (M1F)
Motor compressor
Motor fan
Power circuit
Earth leakage breaker (30mA)
Thermo switch (M1F)
Q1RP
R1T
R2T
R3T
RC
S1HP
S1LP
SD
T1A
Phase reverse circuit
Thermistor (air)
Thermistor (coil)
Thermistor (discharge pipe)
Signal receiver circuit
Pressure switch (high)
Pressure switch (low)
Safety devices input
Current transformer
• Split Sky Air • Outdoor Units
TC
X1M,X2M
Y1E
Y1S
Y2S
CT
Signal transmission circuit
Terminal strip
Expansion valve (electronic type)
4-way valve
Solenoid valve
Current transformer
2TW26336-1B
14
• Outdoor Units • R-410A • REQ-B7
REQ125B7W1B
Switch box
(Outdoor)
Indoor
1
Outdoor
6
Power supply
3N~50Hz
400V
ON
OFF
Note:
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g Field wiring
D : Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Position of
compressor
terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
A1P
BS1
C1
C2
DS1
E1HC
F1U, F2U
HAP
K1M
Printed circuit board
Push button (forced defrost-pump down)
Capacitor (M1F)
Capacitor (M2F)
DIP switch
Crankcase heater
Fuse (T6.3/250V)
Light emitting diode (service monitor green)
Magnetic contactor (M1C)
6-2
Wire
entrance
K1R
K2R
K3R
K4R
K5R,K6R,K7R
K8R,K9R,K10R
M1C
M1F, M2F
PC
Magnetic relay (K1M)
Magnetic relay (Y2S)
Magnetic relay (E1HC)
Magnetic relay (Y1S)
Magnetic relay (M1F)
Magnetic relay (M2F)
Motor compressor
Motor fan
Power circuit
Q1D
Q1M
Q2M
Q1RP
R1T
R2T
R3T
RC
S1PH
Earth leakage breaker (30mA)
Thermo switch (M1F)
Thermo switch (M2F)
Phase reverse circuit
Thermistor (air)
Thermistor (coil)
Thermistor (discharge pipe)
Signal receiver circuit
Pressure switch (high)
S1LP
SD
T1A
TC
X1M,X2M
Y1E
Y1S
Y2S
CT
Pressure switch (low)
Safety devices input
Current transformer
Signal transmission circuit
Terminal strip
Expansion valve (electronic type)
4-way valve
Solenoid valve
Current transformer
2TW26366-1B
External connection diagram
REQ71~125B7
Field wire
Symbol explication
I
II
III
M
S
1
2
3
=
=
=
=
=
=
=
=
Pair
Twin
Triple
Master
Slave
Earth leak detector
Fuse
Remote control
4TW26329-7
15
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B7
7
Sound data
7-1
Sound pressure spectrum
REQ71B7 - Heating
Sound pressure level [dB(A)]
3TW26597-2
Octave band center frequency (Hz)
3TW26597-1
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ71B7 in cooling mode
1
2
3
4
5
Measuring location
(discharge side)
REQ100B7 - Heating
4
5
7-2
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ71B7 in heating mode
1
2
3
Measuring location
(discharge side)
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ100B7 in cooling mode
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ100B7 in heating mode
3TW26637-1
3TW26637-2
Octave band center frequency (Hz)
NOTES
1
2
3
Measuring location
(discharge side)
4
5
Measuring location
(discharge side)
REQ125B7 - Heating
Sound pressure level [dB(A)]
Octave band center frequency (Hz)
NOTES
Octave band center frequency (Hz)
NOTES
REQ125B7 - Cooling
Sound pressure level [dB(A)]
3TW26617-2
1
2
3
3TW26617-1
Sound pressure level [dB(A)]
4
5
Octave band center frequency (Hz)
7
NOTES
NOTES
1
2
3
1
REQ100B7 - Cooling
Sound pressure level (dB)
Sound pressure level (dB)
REQ71B7 - Cooling
3
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ125B7 in cooling mode
Octave band center frequency (Hz)
NOTES
1
2
3
Measuring location
(discharge side)
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ125B7 in heating mode
Measuring location
(discharge side)
Sound power spectrum
• Split Sky Air • Outdoor Units
16
• Outdoor Units • R-410A • REQ-B7
1
7
Sound pressure level [dB(A)]
REQ71B7 - Cooling
3TW26597-3
Octave band center frequency (Hz)
NOTES
1
2
3
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ71B7 in cooling mode
Sound pressure level [dB(A)]
REQ100B7 - Cooling
3TW26617-3
Octave band center frequency (Hz)
NOTES
1
2
3
4
5
17
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ100B7 in cooling mode
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B7
REQ125B7 - Cooling
Sound pressure level [dB(A)]
3
1
7
3TW26637-3
Octave band center frequency (Hz)
NOTES
1
2
3
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20µPa
Curve for REQ125B7 in cooling mode
• Split Sky Air • Outdoor Units
18
• Outdoor Units • R-410A • REQ-B7
8
Installation
8-1
Installation method
REQ71~125B7
1
Oil trap
Indoor unit
8
Oil trap
Outdoor unit
Liquid piping
Install trap at each difference in eight of 15m
Gas piping
NOTE:
Since there is fear of the oil held inside the riser piping flowing back into the compressor when stopped and causing liquid
compression phenomenon, or cases of deterioration of oil return, it well be necessary to provide a trap at an appropriate
place in the riser gas piping.
A trap is not necessary when the outdoor unit is installed in a higher position than the indoor unit.
4TW25149-8
19
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B7
REQ71~125B7
A. Non stacked installation
Legend
Suction side obstacle
Discharge side obstacle
Left side obstacle
3
1
8
Right side obstacle
Top side obstacle
Obstacle is present
In these cases, close the
bottom of the installation
frame to prevent discharged
air from being bypassed.
In these cases, only 2 units can
be installed.
This situation is not allowed.
Figures between ( ) indicate
the dimensions only for the
100-125 class models.
B. Stacked installation
1. Obstacles exist in front of the outlet side
2. Obstacles exist in front of the air inlet
Do not stack more than one unit.
About 100mm is required as the dimension for laying the upper outdoor unit’s drain pipe.
Get the portion A sealed so that air from the outlet does not bypass.
C. Multiple-row installation
1. Installation of one unit per row
2. Installing multiple units (2 units or more) in
lateral connection per row
Relation of dimensions of H, A, and L are shown in the
table below.
L£H
H<L
L
A
0 < L £ 1/2 H
150 (250)
1/2 H < L
200 (300)
Installation impossible
3TW25149-4A
• Split Sky Air • Outdoor Units
20
• Outdoor Units • R-410A • REQ-B7
9
1
Operation range
REQ71~125B7
Model name
Cooling
9
REQ71B7V3B
REQ100B7V3B
REQ71B7W1B
REQ100B7W1B
REQ125B7W1B
Indoor temp. (°CWB)
Notes:
- Depending on operation and installation conditions, the indoor unit can change over to freeze-up
operation (indoor de-icing).
- To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the
outdoor unit in a location not exposed to wind.
21
• Split Sky Air • Outdoor Units
Operation range
Allowable range of operation
(warming-up)
Outdoor temp. (°CWB)
Allowable range of operation (pull-down)
Operation range
Outdoor temp. (°CDB)
Heating
Indoor temperature (°CDB)
3TW26593-1