• Outdoor Units • R-410A • REQ-B7 TABLE OF CONTENTS REQ-B7 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 4 5 8 3 Options 4 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 10 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5 Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 6 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound power spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 7 8 9 .......... ........... .......... .......... .......... .......... . 9 10 15 16 Installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 • Split Sky Air • Outdoor Units 1 • Outdoor Units • R-410A • REQ-B7 o a7t o B0 i d 1- l t4Q puE- SR1 O 1 • Outdoor units for pair and twin application • • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. • The sevice valves are hidden inside the casing. • Outdoor units are fitted with a scroll compressor, renowned for low noise and high energy efficiency. • A special acryl precoated fin for anti-corrosion treatment on the heat exchanger ensures greater resistance against severe weather conditions 1 1 Features • Split Sky Air • Outdoor Units The piping connections can be accessed from underneath, front, side or rear. • Outdoor Units • R-410A • REQ-B7 2 Specifications 3 2-1 TECHNICAL SPECIFICATIONS Casing Dimensions Colour Material Packing Unit Weight Heat Exchanger Fan Motor Fan Motor Fan Compressor Oper ation Range Sound Level (nominal) Height Width Depth Height Width Depth mm mm mm mm mm mm kg kg mm Machine Weight Gross W eight Dimensions Length Nr of Rows Fin Pitch mm Nr of Passes Face m² Area Nr of Stages Tube type Fin Type Treatment Type Discharge direction Quantity Air Flow Rate Cooling m³/min (nominal) Heating m³/min Motor Quantity Model Position Speed Steps (nominal at 230V) Motor Output W Drive Position Speed Steps (nominal at 230V) Motor Output W Drive Quantity Motor Model Type Motor W Output Starting Method Crankcas W e Heater Cooling Min °CDB Max °CDB Heating Min °CWB Max °CWB Cooling Sound dBA Power Sound dBA Pressure R EQ71B7 V3 B REQ7 1B7W1 B R EQ100B 7V3B 900 980 420 770 900 320 83 87 857 2 2.00 6 0.641 900 980 420 770 900 320 83 87 857 2 2.00 6 0.641 Daikin W hite Painted galvanized steel plate 1300 980 420 1170 900 320 102 107 857 2 2.00 10 0.980 34 34 1 48.0 43.0 1 1 48.0 43.0 1 3 3 65 65 REQ1 00B7W1B REQ125B7 W1B 2 1300 980 420 1170 900 320 100 105 857 2 2.00 10 0.980 1300 980 420 1170 900 320 108 113 857 2 2.00 10 0.980 52 52 1 55.0 50.0 1 2 89.0 80.0 1 3 3 Lower 3 90 direct drive 90 85 52 Hi-XSS cooling tube Non- symmetric waffle louvre Anti-corrosion tr eatment (PE) Direct Drive Propeller Hor izontal 1 55.0 50.0 1 P47L11S 1 Upper 3 1 JT90G- V1N 2200 1 1 1 JT90G-YE JT125G-V1N JT125G-YE Hermetically sealed scroll compressor 2200 3000 3000 65 dir ect drive 1 JT160G -YE 3750 33 33 Dir ect 33 33 33 10.0 46.0 -10.0 15.0 65.0 10.0 46.0 -10.0 15.0 65.0 10.0 46.0 -10.0 15.0 70.0 10.0 46.0 -10.0 15.0 70.0 10.0 46.0 -10.0 15.0 70.0 53.0 53.0 57.0 57.0 57.0 • Split Sky Air • Outdoor Units 2 • Outdoor Units • R-410A • REQ-B7 2-1 TECHNICAL SPECIFICATIONS Refr iger ant Refr iger ant Oil 1 2 Piping connections Type Char ge Control Nr of Circuits Type Char ged Volume Liquid (OD) Quantity Type Diameter (O D) Gas Quantity Type Diameter (O D) Drain Quantity Type Diameter (O D) Piping Length Minimum Maximum Equivalen t Char gele ss Installation Maximum height difference Max. internunit level difference Heat Insulation Defr ost Method Defr ost Control Capacity Contr ol Method Safety Devices Standard Accessories Notes 3 Item Quantity Item Quantity kg REQ71B 7V3B REQ71B7W1B 2.50 2.50 1 1 l 1.5 1 1.5 1 mm 9.52 9.52 1 1 15.9 15.9 3 3 mm 26 m m m mm REQ100 B7V3B REQ100B7W1B R-410A 3.60 Expansion valve ( electr onic type) 1 Daphne FVC68D 1.5 1 Flare connection 9.52 1 Flare connection 15.9 R EQ125B 7W1B 3.60 3.60 1 1 1.5 1 1.5 1 9.52 9.52 1 1 15.9 15.9 3 3 26 3 Hole 26 26 26 5 50 70 5 50 70 5 50 70 5 50 70 5 50 70 m 7.5 7.5 7.5 7.5 7.5 m 30.0 30.0 30.0 30.0 30.0 m 0.5 0.5 0.5 0.5 0.5 Both liquid and gas pipes Reversed cycle Sensor for outdoor heat exchanger temperature None Reverse phase protector PC board fuse Over cur rent relay (compressor) Low pressure switch High pr essur e switch Fan motor thermal protector Declar ation of conformity 1 1 1 1 1 Installation manual 1 1 1 1 1 Sound pressur e level is a r elative value, depending on the distance and acoustic environment. For mor e details, please refer to sound level dr awings of this chapter. The sound power level is an absolute value indicating the power which a sound source gener ates. Sound values are measured in a semi- anechoic room. In case of drain piping for outdoor unit, drain piping kit (option) is needed. Nominal cooling capacities are based on : indoor temperature : 27° CDB, 19°CWB, outdoor temperature : 35° CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. Nominal heating capacities are based on : indoor temperatur e : 20°CDB, outdoor temperature : 7°CDB, 6° CW B, equivalent refrigerant piping : 7.5m, level difference : 0m • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B7 2-2 ELECTRICAL SPECIFICATIONS Power Supply Cur rent Voltage range Wiring connections Name Phase Frequency Voltage Z-max Text Recomended fuses Minimum Maximum For Power Quantity Supply Remark For connection Quantity with indoor Remark Power Supply Intake Hz V A V V R EQ71B7 V3 B REQ7 1B7W1 B V3 1 50 230 0,06+j0,04 32 207 253 1 3 wires (ear th wire included) 1 W1 3N 50 400 0,35+j0,22 16 360 440 1 5 wires (earth wir e included) 1 R EQ100B 7V3B REQ1 00B7W1B V3 W1 1 3N 50 50 230 400 0,04+j0,02 0,31+j0,19 40 16 207 360 253 440 1 1 3 wires (earth wire 5 wires (earth wire included) included) 1 1 4 wir es (earth wir e included) Outdoor unit only REQ125B7 W1B W1 3N 50 400 0,26+j0,16 20 360 440 1 5 wires (earth wire included) 1 3 1 2 NOTES • Split Sky Air • Outdoor Units 4 • Outdoor Units • R-410A • REQ-B7 2-3 Electrical data REQ71B7 Unit combination Indoor unit Outdoor unit Hz-Volts Power supply Voltage range Compressor LRA RLA MCA TOCA MFA 16.6 23.3 32 75.5 16.8 23.2 32 17.4 23.5 OFM IFM kW FLA kW FLA 12.2 0.065 0.6 0.045 0.7 75.5 12.5 0.065 0.6 0.062 0.6 32 75.5 12.7 0.065 0.6 0.125 0.9 FCQ71 REQ71B7V3B 50-230 1 FHQ71 REQ71B7V3B 50-230 2 FBQ71 REQ71B7V3B 50-230 FDEQ71 REQ71B7V3B 50-230 15.4 23.5 32 75.5 11.1 0.065 0.6 0.125 0.9 FCQ71 REQ71B7W1B 50-400/230 7.3 11.3 16 41.1 4.8 0.065 0.6 0.045 0.7 FHQ71 REQ71B7W1B 50-400/230 7.5 11.2 16 41.1 5.0 0.065 0.6 0.062 0.6 FBQ71 REQ71B7W1B 50-400/230 8.1 11.5 16 41.1 5.3 0.065 0.6 0.125 0.9 FDEQ71 REQ71B7W1B 50-400/230 6.8 11.5 16 41.1 4.2 0.065 0.6 0.125 0.9 Max. 50Hz-253V Min. 50Hz-207V Max. 50Hz-440/253V Min. 50Hz-360/207V 3TW26599-9 MCA TOCA MFA LRA RLA OFM IFM FLA kW 5 : : : : : : : : : SYMBOLS Min. Circuit Amps Total Over Current Amps Max. Fuse Amps (see note 7) Locked Rotor Amps Rated Load Amps Outdoor Fan Motor Indoor Fan Motor Full Load Amps Rated motor output • Split Sky Air • Outdoor Units NOTES 1. RLA is based on the following conditions: Indoor temp.: 27°CDB/19.5°CWB Outdoor temp. : 35°CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 16A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select ’’Daikin Documentation’’ and select ’’conditional connection’’, ’’the requested product type’’ and ’’English’’ from the drop down lists, click the search button. Finally, click on the document title of your choice. • Outdoor Units • R-410A • REQ-B7 REQ100B7 Unit combination Indoor unit Outdoor unit Hz-Volts Power supply Voltage range Compressor LRA RLA MCA TOCA MFA 23.8 34.8 40 98.5 25.3 34.5 40 23.2 34.8 OFM IFM kW FLA kW FLA 17.6 0.090 0.8 0.090 1.0 98.5 19.0 0.090 0.8 0.130 0.7 40 98.5 17.1 0.090 0.8 0.135 1.0 1 2 FCQ100 REQ100B7V3B 50-230 FHQ100 REQ100B7V3B 50-230 FBQ100 REQ100B7V3B 50-230 FDEQ100 REQ100B7V3B 50-230 24.2 34.8 40 98.5 17.9 0.090 0.8 0.135 1.0 FCQ100 REQ100B7W1B 50-400/230 9.2 11.8 16 48.2 5.9 0.090 0.8 0.090 1.0 FHQ100 REQ100B7W1B 50-400/230 9.4 11.5 16 48.2 6.3 0.090 0.8 0.130 0.7 FBQ100 REQ100B7W1B 50-400/230 8.9 11.8 16 48.2 5.7 0.090 0.8 0.135 1.0 FDEQ100 REQ100B7W1B 50-400/230 9.6 11.8 16 48.2 6.2 0.090 0.8 0.135 1.0 Max. 50Hz-253V Min. 50Hz-207V Max. 50Hz-440/253V Min. 50Hz-360/207V 3 3TW26619-9 MCA TOCA MFA LRA RLA OFM IFM FLA kW : : : : : : : : : SYMBOLS Min. Circuit Amps Total Over Current Amps Max. Fuse Amps (see note 7) Locked Rotor Amps Rated Load Amps Outdoor Fan Motor Indoor Fan Motor Full Load Amps Rated motor output • Split Sky Air • Outdoor Units NOTES 1. RLA is based on the following conditions: Indoor temp.: 27°CDB/19.5°CWB Outdoor temp. : 35°CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 16A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select ’’Daikin Documentation’’ and select ’’conditional connection’’, ’’the requested product type’’ and ’’English’’ from the drop down lists, click the search button. Finally, click on the document title of your choice. 6 • Outdoor Units • R-410A • REQ-B7 REQ125B7 Unit combination Indoor unit Outdoor unit 1 Hz-Volts Power supply Voltage range MCA TOCA MFA Compressor LRA RLA OFM IFM kW FLA kW FLA FCQ125 REQ125B7W1B 50-400/230 12.4 15.3 20 63 8.1 0.065 + 0.085 0.6 + 0.7 0.09 1.0 FHQ125 REQ125B7W1B 50-400/230 12.3 15.0 20 63 8.2 0.065 + 0.085 0.6 + 0.7 0.13 0.7 2 Max. 50Hz-440/253V Min. 50Hz-360/207V FBQ125 REQ125B7W1B 50-400/230 12.2 15.7 20 63 7.6 0.065 + 0.085 0.6 + 0.7 0.225 1.4 FDEQ125 REQ125B7W1B 50-400/230 12.6 15.7 20 63 7.9 0.065 + 0.085 0.6 + 0.7 0.225 1.4 3TW26639-9 MCA TOCA MFA LRA RLA OFM IFM FLA kW 7 : : : : : : : : : SYMBOLS Min. Circuit Amps Total Over Current Amps Max. Fuse Amps (see note 7) Locked Rotor Amps Rated Load Amps Outdoor Fan Motor Indoor Fan Motor Full Load Amps Rated motor output • Split Sky Air • Outdoor Units NOTES 1. RLA is based on the following conditions: Indoor temp.: 27°CDB/19.5°CWB Outdoor temp. : 35°CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 16A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://www.daikineurope.com/extranet, select ’’Daikin Documentation’’ and select ’’conditional connection’’, ’’the requested product type’’ and ’’English’’ from the drop down lists, click the search button. Finally, click on the document title of your choice. • Outdoor Units • R-410A • REQ-B7 2-4 Safety device settings 3 REQ71~125B7 Model Safety device REQ71B7V3B REQ100B7V3B REQ71B7W1B REQ100B7W1B LPS Max discharge temperature Overcurrent relay 1 Off 135 ±5°C Fan motor thermal protector HPS REQ125B7W1B On 95 ±15°C +0 0,10 Mpa +0,15 - 0,15 Mpa Off 4,15 On 3.2 +0,02 0,02 Off -0.03 - 2 Mpa On 0.05 +0,03 - 0,03 Mpa By thermistor and software control By overcurrent sensor and software control 4TW26321-2B • Split Sky Air • Outdoor Units 8 • Outdoor Units • R-410A • REQ-B7 3 1 3 Options REQ71~125B7 Name of option Central drain plug Kit name REQ71B7 REQ100B7 REQ125B7 KKPJ5F180 4TW26599-1 9 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B7 4 Dimensional drawing & centre of gravity 4-1 Dimensional drawing 3 unit (mm) REQ71B7 Hole for anchor bolt 4-M12 1 2 3 4 5 6 7 8 Gas pipe connection J15.9 flare Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock hole J34) Control wiring intake (knock hole J27) Drain outlet 1 4 3TW26324-1 unit (mm) REQ100B7 Hole for anchor bolt 4-M12 1 2 3 4 5 6 7 8 Gas pipe connection J15.9 flare Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock hole J34) Control wiring intake (knock hole J27) Drain outlet 3TW26344-1 • Split Sky Air • Outdoor Units 10 • Outdoor Units • R-410A • REQ-B7 unit (mm) REQ125B7 1 2 3 4 5 6 7 8 Hole for anchor bolt 4-M12 1 Gas pipe connection J15.9 flare Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock hole J34) Control wiring intake (knock hole J27) Drain outlet 4 3TW26364-1 4-2 Centre of gravity REQ71B7 Model REQ71B7 A 267 3TW26329-5C 11 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B7 REQ100B7 3 1 4 Model REQ100B7 A 390 3TW26349-5C REQ125B7 Model REQ125B7 A 390 3TW26369-5C • Split Sky Air • Outdoor Units 12 • Outdoor Units • R-410A • REQ-B7 5 1 Piping diagram REQ71~125B7 (Pair) Electronic expansion valve Solenoid valve 5 One way valve One way valve One way valve One way valve Filter Heat exchanger Filter Service port 5/16† Strainer Receiver Capillary tube Heat exchanger One way valve 4-way valve Filter High pressure switch Low pressure switch Muffler Field piping J9.5 C122OT-O Service port 5/16† Filter Field piping J15.9 C122OT-O Compressor Indoor unit Stop valve (with service port 1/4 †flare) Outdoor unit Heating Cooling O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 3TW26325-1 REQ71~125B7 (Twin) Solenoid valve Heat exchanger Electronic expansion valve One way valve One way valve Filter Heat exchanger Filter One way valve Service port 5/16† Strainer Field piping Filter One way valve Receiver Field piping Capillary tube Indoor unit One way valve 4-way valve Filter Heat exchanger Low pressure switch High pressure switch Muffler Field piping J9.5 Service port 5/16† Branch pipe (Option) Field piping J15.9 Compressor Field piping Filter Indoor unit Field piping Stop valve (with service port 5/16 †flare) Outdoor unit O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe 13 • Split Sky Air • Outdoor Units Heating Cooling 3TW26325-2 • Outdoor Units • R-410A • REQ-B7 6 Wiring diagram 6-1 Wiring diagram 3 REQ71-100B7V3B Power supply 1~50Hz 230V A1P BS1 C1R C3R DS1 E1HC F1U HAP K1M K1R K2R K3R K4R K5R,K6R,K7R M1C M1F PC Q1DI Q1M R1T R2T R3T RC S1PH S1LP SD T1A TC X1M,X2M Y1E Y1S Y2S CT Printed circuit board Push button (forced defrost-pump down) Capacitor (M1F) Capacitor (M1C) DIP switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) Magnetic relay (K1M) Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Motor compressor Motor fan Power circuit Earth leakage breaker (30mA) Thermo switch (M1F) Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer Signal transmission circuit Terminal strip Expansion valve (electronic type) 4-way valve Solenoid valve Current transformer 1 Indoor 6 Outdoor ON OFF Switch box (Outdoor) Position of compressor terminal Note: Wire entrance Confirm the method of setting the DIP switch (DS1) by service manual when the unit is shipped by factory all switches are set to be off. g Field wiring D : Terminal F : Connector b : Protective earth (screw) L : Live N : Neutral : Terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow 2TW26326-1B REQ71-100B7W1B Switch box (Outdoor) Indoor Outdoor Power supply 3N~50Hz 400V ON Note: OFF Confirm the method of setting the DIP switch (DS1) by service manual when the unit is shipped by factory all switches are set to be off. g Field wiring D : Terminal F : Connector b : Protective earth (screw) L : Live N : Neutral : Terminal Position of compressor terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow A1P BS1 C1 DS1 E1HC F1U, F2U HAP K1M K1R Printed circuit board Push button (forced defrost-pump down) Capacitor (M1F) DIP switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) Magnetic relay (K1M) Wire entrance K2R K3R K4R K5R,K6R,K7R M1C M1F PC Q1DI Q1M Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Motor compressor Motor fan Power circuit Earth leakage breaker (30mA) Thermo switch (M1F) Q1RP R1T R2T R3T RC S1HP S1LP SD T1A Phase reverse circuit Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer • Split Sky Air • Outdoor Units TC X1M,X2M Y1E Y1S Y2S CT Signal transmission circuit Terminal strip Expansion valve (electronic type) 4-way valve Solenoid valve Current transformer 2TW26336-1B 14 • Outdoor Units • R-410A • REQ-B7 REQ125B7W1B Switch box (Outdoor) Indoor 1 Outdoor 6 Power supply 3N~50Hz 400V ON OFF Note: Confirm the method of setting the DIP switch (DS1) by service manual when the unit is shipped by factory all switches are set to be off. g Field wiring D : Terminal F : Connector b : Protective earth (screw) L : Live N : Neutral : Terminal Position of compressor terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow A1P BS1 C1 C2 DS1 E1HC F1U, F2U HAP K1M Printed circuit board Push button (forced defrost-pump down) Capacitor (M1F) Capacitor (M2F) DIP switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) 6-2 Wire entrance K1R K2R K3R K4R K5R,K6R,K7R K8R,K9R,K10R M1C M1F, M2F PC Magnetic relay (K1M) Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Magnetic relay (M2F) Motor compressor Motor fan Power circuit Q1D Q1M Q2M Q1RP R1T R2T R3T RC S1PH Earth leakage breaker (30mA) Thermo switch (M1F) Thermo switch (M2F) Phase reverse circuit Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) S1LP SD T1A TC X1M,X2M Y1E Y1S Y2S CT Pressure switch (low) Safety devices input Current transformer Signal transmission circuit Terminal strip Expansion valve (electronic type) 4-way valve Solenoid valve Current transformer 2TW26366-1B External connection diagram REQ71~125B7 Field wire Symbol explication I II III M S 1 2 3 = = = = = = = = Pair Twin Triple Master Slave Earth leak detector Fuse Remote control 4TW26329-7 15 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B7 7 Sound data 7-1 Sound pressure spectrum REQ71B7 - Heating Sound pressure level [dB(A)] 3TW26597-2 Octave band center frequency (Hz) 3TW26597-1 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ71B7 in cooling mode 1 2 3 4 5 Measuring location (discharge side) REQ100B7 - Heating 4 5 7-2 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ71B7 in heating mode 1 2 3 Measuring location (discharge side) 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ100B7 in cooling mode Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ100B7 in heating mode 3TW26637-1 3TW26637-2 Octave band center frequency (Hz) NOTES 1 2 3 Measuring location (discharge side) 4 5 Measuring location (discharge side) REQ125B7 - Heating Sound pressure level [dB(A)] Octave band center frequency (Hz) NOTES Octave band center frequency (Hz) NOTES REQ125B7 - Cooling Sound pressure level [dB(A)] 3TW26617-2 1 2 3 3TW26617-1 Sound pressure level [dB(A)] 4 5 Octave band center frequency (Hz) 7 NOTES NOTES 1 2 3 1 REQ100B7 - Cooling Sound pressure level (dB) Sound pressure level (dB) REQ71B7 - Cooling 3 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ125B7 in cooling mode Octave band center frequency (Hz) NOTES 1 2 3 Measuring location (discharge side) 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ125B7 in heating mode Measuring location (discharge side) Sound power spectrum • Split Sky Air • Outdoor Units 16 • Outdoor Units • R-410A • REQ-B7 1 7 Sound pressure level [dB(A)] REQ71B7 - Cooling 3TW26597-3 Octave band center frequency (Hz) NOTES 1 2 3 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ71B7 in cooling mode Sound pressure level [dB(A)] REQ100B7 - Cooling 3TW26617-3 Octave band center frequency (Hz) NOTES 1 2 3 4 5 17 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ100B7 in cooling mode • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B7 REQ125B7 - Cooling Sound pressure level [dB(A)] 3 1 7 3TW26637-3 Octave band center frequency (Hz) NOTES 1 2 3 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20µPa Curve for REQ125B7 in cooling mode • Split Sky Air • Outdoor Units 18 • Outdoor Units • R-410A • REQ-B7 8 Installation 8-1 Installation method REQ71~125B7 1 Oil trap Indoor unit 8 Oil trap Outdoor unit Liquid piping Install trap at each difference in eight of 15m Gas piping NOTE: Since there is fear of the oil held inside the riser piping flowing back into the compressor when stopped and causing liquid compression phenomenon, or cases of deterioration of oil return, it well be necessary to provide a trap at an appropriate place in the riser gas piping. A trap is not necessary when the outdoor unit is installed in a higher position than the indoor unit. 4TW25149-8 19 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B7 REQ71~125B7 A. Non stacked installation Legend Suction side obstacle Discharge side obstacle Left side obstacle 3 1 8 Right side obstacle Top side obstacle Obstacle is present In these cases, close the bottom of the installation frame to prevent discharged air from being bypassed. In these cases, only 2 units can be installed. This situation is not allowed. Figures between ( ) indicate the dimensions only for the 100-125 class models. B. Stacked installation 1. Obstacles exist in front of the outlet side 2. Obstacles exist in front of the air inlet Do not stack more than one unit. About 100mm is required as the dimension for laying the upper outdoor unit’s drain pipe. Get the portion A sealed so that air from the outlet does not bypass. C. Multiple-row installation 1. Installation of one unit per row 2. Installing multiple units (2 units or more) in lateral connection per row Relation of dimensions of H, A, and L are shown in the table below. L£H H<L L A 0 < L £ 1/2 H 150 (250) 1/2 H < L 200 (300) Installation impossible 3TW25149-4A • Split Sky Air • Outdoor Units 20 • Outdoor Units • R-410A • REQ-B7 9 1 Operation range REQ71~125B7 Model name Cooling 9 REQ71B7V3B REQ100B7V3B REQ71B7W1B REQ100B7W1B REQ125B7W1B Indoor temp. (°CWB) Notes: - Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). - To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind. 21 • Split Sky Air • Outdoor Units Operation range Allowable range of operation (warming-up) Outdoor temp. (°CWB) Allowable range of operation (pull-down) Operation range Outdoor temp. (°CDB) Heating Indoor temperature (°CDB) 3TW26593-1