Download 3048A_Option_K21_AM-Detector
Transcript
HP Archive This vintage Hewlett Packard document was preserved and distributed by www. hparchive.com Please visit us on the web ! On-line curator: John Miles, KE5FX m HEWLETT PACKARD OPERATING AND SERVICE MANUAL MODEL 3048A OPTION AM DETECTOR K 2 1 F I L T E R How To Use This Manual This Manual should be used in conjunction w i t h the 3048A Operating Manual, HP Part Number 03048-90001 ( p r i n t e d March 1988), and the 3048A Reference Manual, HP Part Number 03048-90002 ( p r i n t e d June 1988). Applicable Serial Numbers This Manual M o d i f i c a t i o n Insert applies to instruments with s e r i a l number prefixes greater that or equal to 2820A. Updates t o t h i s Manual Insert P e r i o d i c a l l y , changes are made to t h i s Manual Insert to c o r r e c t errors in the o r i g i n a l p r i n t i n g and to include Option improvements. Corrections are indicated by a mark at the right-hand edge of the modified t e s t . The mark used is keyed to the date the c o r r e c t i o n s are added (found on t h i s cover page below the issue d a t e ) . Manual Modification Inset HP Part Number 03048-92035 Issued November 1988 Updated June 1989 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m 3048A Option K21 HEWLETT PACKARD 03048-92035 Page 2 of 21 SECTION I. GENERAL INFORMATION 1-1. INTRODUCTION This manual contains information required to install, operate, and service the Hewlett-Packard Model 3048A Option K21 AM Detector Filter, an optional accessory for the HP 3048A Phase Noise Measurement System. The AM Detector Filter Operating and Service Manual has five sections. The subjects addressed are: SECTION SECTION SECTION SECTION SECTION 1-2. I II III IV V GENERAL INFORMATION OPERATION PERFORMANCE TESTS REPLACEABLE PARTS SERVICE SPECIFICATIONS Instrument specifications are listed in Table 1-1. These specifications are the performance standards or limits against which the instrument may be tested. Table 1-1. Specifications Characteristics Performance Limits MAXIMUM INPUT DC +/-5 V FLATNESS +/-0.5 dB Conditions 1 Hz to 40 MHz Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m HEWLETT PACKARD 3048A Option K21 03048-92035 Page 3 1 1-3. DESCRIPTION The HP Model 3048A Option K21 AM Detector Filter is an accessory to the HP 3048A Phase Noise Measurement System. It contains a DC return for an AM detector, such as the HP 33330C/D, and a DC blocking capacitor. The insertion loss of the AM Detector Filter is typically less than 1.5 dB. The switch on the front cover can be set for either positive or negative AM detector polarity. 1-4. INITIAL INSPECTION Inspect the shipping container. If the container and/or packing material is damaged, it should be kept until the contents of the shipment have been checked mechanically and electrically. If there is mechanical damage or if the instrument does not pass the performance tests, notify the nearest Hewlett-Packard office. Keep the damaged shipping materials (if any) for inspection by the'carrier and a Hewlett-Packard representative. 1-5. ACCESSORIES The accessories supplied with the HP 3048A Opt. K21 are listed below: IMPEDANCE MATCHING NETWORK CALIBRATION LOAD CALIBRATION CABLES (2) ADAPTOR SMA(F) TO SMC(F) (3) ADAPTOR SMA(M) TO SMC(F) (1) 03048-62013 03048-62014 03048-62017 1250-1694 1250-1697 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. of 2] fm 3048A HFWI FTT E nPM t f r r C I r f l Z .KM P A C K A R D SECTION I I . 2-1. p °Pt,0n 03048-92035 4 f 2j OPERATION APPLICATIONS An AM noise measurement can be made with a HP 3048A as described in 'AM Noise Using an HP 33330C on page 3-111 of the HP 3048A Phase Noise Measurement System Operating Manual. The HP 3048A Opt. K21 AM Detector F i l t e r i s substituted f o r the f i l t e r network described in Table 3-22, and shown schematically i n Figure 3 - 3 1 . 2-2. K21 CONNECTIONS To setup the equipment f o r an AM Noise Measurement w i t h the HP 3048A and AM Detector F i l t e r , r e f e r to Figure 2 - 1 . The best r e s u l t s w i l l be obtained when s e m i - r i g i d coaxial cables are used t o connect the components used in the measurement and should be used whenever possible. Ground loops can be a problem in t h i s type of measurement. To minimize ground loops, a DC Block is inserted between the RF source under t e s t and the AM d e t e c t o r . The recommended DC Block i s the Narda 562 (Type-N connectors, 10 MHz to 12.4 GHz) or the Narda 4563 (SMA connectors, 500 MHz to 18 GHz). DC Blocks may also be referred to as Audio Interface Suppressors or Noise Suppressors. A ground loop can be suspected i f the 60 Hz spurs have an amplitude greater than -80 dBc. Connect the AM detector d i r e c t l y to the input connector of the HP 3048A Opt. K21 AM Detector F i l t e r . The output of the AM Detector F i l t e r should be connected d i r e c t l y t o the HP 11848A Phase Noise Interface front-panel 'NOISE INPUT' connector. However, i f a DC Block i s inserted between the RF source under t e s t and the AM d e t e c t o r , i t i s not necessary t o connect the output o f the AM Detector F i l t e r t o the 'NOISE INPUT' of the HP 11848A. A short s e m i - r i g i d cable w i l l be s u f f i c i e n t to make t h i s connection i f a DC Block is used. To connect the AM Detector F i l t e r d i r e c t l y t o the 'NOISE INPUT', connect a N(m) to SMA(m) adaptor (HP part number 12501994, one is supplied with the HP 3048A as part of the Noise Floor F i x t u r e , HP part number 03048-61032) to the HP 11848A 'NOISE INPUT'. Then connect a SMA(m) to SMA(f) r i g h t angle adaptor (HP part number 1250-1249) to the N(m) to SMA(m) adaptor and the HP 3048A Opt. K21 AM Detector F i l t e r output. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane D i v i s i o n East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m 3048A Option K21 HEWLETT PACKARD 03048-92035 Page 5 of 21 HP 3561A DYNAMIC SIGNAL ANALYZER HP I1848A PHASE NOISE INTERFACE HP 33330C/D COAXIAL CRYSTAL DETECTOR HP 3048A OPT. K21 AM DETECTOR FILTER FIGURE 2-1. SETUP FOR AM NOISE MEASUREMENT WITH HP 3048A Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. tma 3048A Option K21 HEWLETT PACKARD SECTION III. 3-1. 03048-92035 Page 6 of 21 PERFORMANCE TESTS INTRODUCTION The procedures in this section test the instrument's electrical performance using the specifications of Table 1-1 as performance standards. All tests are performed without accessing the interior of the instrument. NOTE For greatest accuracy, allow the test warm up at least one-half hour. 3-2. equipment to PERFORMANCE TEST RESULTS Results of the performance tests may be tabulated in the Test Results Tables at the end of each procedure. The Test Results Tables list all of the tests specifications and acceptable limits. The results recorded at incoming inspection, can be used for comparison in periodic maintenance, troubleshooting, and after repairs. 3-3. CALIBRATION CYCLE This instrument requires periodic verification of performance. Depending on the use and environmental conditions, the instrument should be checked using the following performance test at least once every year. 3-4. SPECIAL EQUIPMENT A Calibration Load and Impedance Matching Network are required to run these Performance Tests. One of each is supplied with the HP 3048A Opt. K21 AM Detector Filter. Service information on these devices and an easy method to build replacements if the originals are lost or damaged are given starting on page 16 of this manual. 3-5. PERFORMANCE TESTING No abbreviation of the performance testing is recommended. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. 3048A Option K21 03048-92035 Page 7 of 21 WKS% HEWLETT \L'HM PACKARD PERFORMANCE TEST 1 100 KHZ TO 40 MHZ FLATNESS TEST DESCRIPTION This t e s t measures the f l a t n e s s of the HP 3048A Opt. K21 AM Detector F i l t e r from 100 kHz to 40 MHz w i t h a HP 3585A/B. A reference i s taken w i t h the HP 3585A/B t r a c k i n g generator connected by a short cable to the impedance matching network and c a l i b r a t i o n l o a d . The c a l i b r a t i o n load output i s connected t o the 50 ohm input of the HP 3585A/B w i t h a short cable. Once the reference trace is measured and stored in the HP 3585A/B memory, the reference load i s replaced w i t h the device under t e s t (DUT). The r e s u l t s are then measured and recorded in Table 3 - 1 . EQUIPMENT SPECTRUM ANALYZER IMPEDANCE MATCHING NETWORK CALIBRATION LOAD CALIBRATION CABLES (2) HP 3585A/B 03048-62013 03048-62014 03048-62017 PROCEDURE 1. Connect the equipment up as shown in Figure 3 - 1 . HP 3585A/B SPECTRUM ANALYZER HWOONG t»>o»u-iroo FIGURE 3-1. SETUP FOR REFERENCE MEASUREMENT WITH HP 3585A/B Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. tvi 3048A Option K21 HEWLETT PACKARD 03048-92035 Page 8 of 21 2. Press the green [INSTR PRESET] key on the HP 3585A/B. 3. Setup the HP 3585A/B as follows: START FREQ STOP FREQ dB/DIV 100 kHz 40 MHz 1 dB REFERENCE LEVEL AUTO RANGE -30 dBm OFF 4. The trace should be in the upper h a l f of the HP 3585A/B d i s p l a y . I f the trace looks good, press the [STORE A -> B] key on the HP 3585A/B. 5. Press the [A-B] key on the HP 3585A/B t o a c t i v a t e the t r a c e . 6. Turn o f f the B trace by pressing the [VIEW B] key on the HP 3585A/B. There should only be one trace on the HP 3585A/B CRT and i t should be a s t r a i g h t l i n e i n the middle o f the screen. 7. Replace the C a l i b r a t i o n Load w i t h the Opt. K21 AM Detector F i l t e r as shown in Figure 3-2. HP 3585A/B SPECTRUM ANALYZER HP 030*8-62013 IMPEDANCE MATCHING NEW** HP 0 3 0 * 8 - 62017 CAUBOATON CAfllf MP3048A OPT. K21 AM D 6 T E C T O R FILTER FIGURE 3-2. SETUP FOR FLATNESS TEST WITH HP 3585A/B. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. 3048A Option K21 03048-92035 Page 9 of 21 WhatHEWLETT mL'HM PACKARD 8. Set the 'DETECTOR POLARITY' switch on the HP 3048A Opt. K21 AM Detector Filter to the 'POS' position. 9. Use the rotory knob on the HP 3585A/B to position the cursor within 700 Hz of the frequencies listed in Table 3-1. Record the cursor level under the 'POS DETECTOR POLARITY' in Table 3-1. 10. Set the 'DETECTOR POLARITY' switch to the 'NEC position and repeat Step 9. Record the results under 'NEG DETECTOR POLARITY' in Table 3-1. TABLE 3-1. FLATNESS TEST RESULTS FROM 100 kHz TO 40 MHz MEASURED RESULTS FREQ (MHz) .1 4.0 8.0 12.0 16.0 20.0 24.0 28.0 32.0 36.0 40.0 POS DETECTOR POLARITY NEG DETECTOR POLARITY LEVEL (dB) LEVEL (dB) LOWER LIMIT (dB) UPPER LIMIT (dB) -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 LOWER LIMIT (dB) UPPER LIMIT (dB) -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 -0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. What 3048A Option K21 03048-92035 Page 10 of 21 HEWLETT MlfnM PACKARD PERFORMANCE TEST 2 ,1 HZ TO 10 HZ FLATNESS TEST DESCRIPTION This test measures the flatness of the HP 3048A Opt. K21 from .1 Hz to 10 Hz with a HP 3561A. A reference is taken with the HP 3561A Noise Source (rear panel) connected with a BNC cable to the impedance matching network and calibration load. The calibration load output is connected to the HP 3561A input through a 50 ohm feed-thru with a short cable. After the reference trace is measured and stored in the HP 3561A's memory, the reference load is replaced with the device under test (DUT). The results are measured and recorded in Table 3-2. EQUIPMENT SPECTRUM ANALYZER IMPEDANCE MATCHING NETWORK CALIBRATION LOAD CALIBRATION CABLE (2) 50 OHM FEEDTHRU BNC CABLE BNC ADAPTOR HP 3561A 03048-62013 03048-62014 03048-62017 HP 10100C 8120-1840 1250-0080 PROCEDURE 1. Connect the equipment as shown in Figure 3-3. HP 3S6IA DYNAMIC SGNAL ANALYZER -OCA M X K 1 0UTW1W*«I BWCCABtf BNC M W t t n . K K M — / ~~ ■oNG M TWO- FIGURE 3-3. \ " - •• » H <■-.-■ CKIOAO SETUP FOR REFERENCE MEASUREMENT WITH HP 3561A Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m HEWLETT r,«rC(7rriZ PACKARD 2. 3048A ° p t i ° n K21 03048-92035 Page 11 of 21 Press the green [PRESET] key on the HP 3561A. 3. Setup the HP 3561A as follows: FORMAT FREQ SINGLE START 0 Hz 10 Hz SPAN FREQ AXIS to log WINDOW UNIFORM SOURCE PERIODIC NOISE 0 dB ATTN RANGE AUTO RNG off perform SINGLE AUTO RNG INPUT RMS 4 AVGS START start a measurement sweep 4. Wait for the HP 3561A to complete the sweep of 4 averages and then continue the setup of the HP 3561A as follows: VERT SCALE STORE/RECALL DEFINE TRACE SINGLE AUTO SCL STORE IN Ml MATH FCN SELECT MAG / Ml VERT SCALE perform SINGLE AUTO SCL 2 dBV FULL SCALE 5. The trace should be a straight line in the center of the HP 3561A display. 6. Replace the Calibration Load with the AM Detector Filter as shown in Figure 3-4 and set the 'DETECTOR POLARITY' switch to the 'POS' position. 7. Press the [START] key on the HP 3561A and wait for the HP 3561A to complete the measurement. 8. Position the HP 3561A marker to each of the frequencies listed in Table 3-2 by pressing [MKR], (DEFINE MKR POS), frequency to be measured (in hertz), and (Hz) on the HP 3561A. Record the marker level for each frequency under 'POS DETECTOR POLARITY' in Table 3-2. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m 3048A Option K21 03048-92035 Page 12 of 21 HEWLETT PACKARD 9. Set the 'DETECTOR POLARITY' switch to the 'NEC position. Repeat Steps 7 and 8. Record the results under 'NEG DETECTOR POLARITY' in Table 3-2. HP 3561A DYNAMIC SIGNAL ANALYZER f * x t SOURCE OUT PUU HEAP) BNCCABlf BCO-B40 " B « ADAPTER «0-O0M •*• 03048-620" HP W04B-4J013 CAIORA'CN CADU «*PtD*MC£ M A T C H * UtTWiCfl" MP»48A OPT. K21 AMOEUCTOnrWEf FIGURE 3-4. SETUP FOR FLATNESS TEST WITH HP 3561A TABLE 3-2. FLATNESS TEST RESULTS FROM .1 HzTO 10 Hz MEASURED RESULTS FREQ (MHz) POS DETECTOR POLARITY LEVEL (dB) 0.1 1.0 5.0 10.0 LOWER LIMIT (dB) UPPER LIMIT (dB) -5.0 -0.5 -0.5 -0.5 -2.0 0.5 0.5 0.5 NEG DETECTOR POLARITY LEVEL (dB) LOWER LIMIT (dB) UPPER LIMIT (dB) -5.0 -0.5 -0.5 -0.5 -2.0 0.5 0.5 0.5 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. LV1 3048A Option K21 03048-92035 Page 13 of 21 HEWLETT PACKARD PERFORMANCE TEST 3 DC LEAKAGE TEST DESCRIPTION This t e s t measures the leakage current of the capacitors in the AM Detector F i l t e r . A 5V supply i s applied to the input. The output is connected through a 50 ohm feed-thru to the input of a v o l t m e t e r . The leakage current is measured by measuring the voltage dropped across the 50 ohm f e e d - t h r u . EQUIPMENT VOLTMETER POWER SUPPLY 50 OHM FEED-THRU HP 3478A HP 6205B HP 10100C PROCEDURE 1. Connect the equipment up as shown in Figure 3-5. 2. Set the 'DETECTOR POLARITY' switch to the 'POS' position. 3. Turn on the power supply and set it for +5 Volts. 4. Wait for 2 minutes and then read the voltmeter. Record the voltmeter reading below: Voltmeter reading spec: < 3.5 mV ,.»,, .... FIGURE 3-5. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m 3048A Option K21 03048-92035 Page 14 of 21 HEWLETT PACKARD SECTION IV. REPLACEABLE PARTS Table 4-1 l i s t s the replaceable p a r t s . I t is organized w i t h the e l e c t r i c a l components f i r s t , in alphabetical order by reference designator, followed by mechanical p a r t s . The f o l l o w i n g information i s given f o r each part: a. b. c. d. e. the the the the the reference designator; HP Part Number; total quantity (Qty) used in the instrument; part number check digit (CD); and description of the parts. TABLE 4-1. REPLACEABLE PARTS REFER. DESIG. HP PART NUMBER Al A1C1 A1C2 A1C3 A1C4 A1C5 A1C6 A1C7 A1C8 A1C9 A1C10 A1C11 A1C12 A1C13 A1C14 A1C15 A1C16 A1CR1 A1CR2 A1CR3 A1J1 03048-62101 0160-4380 0160-3873 0160-5469 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 0180-2144 1901-0880 1901-0880 1901-0731 1250-2091 QTY 1 1 1 1 13 2 1 2 C D DESCRIPTION 3 0 3 9 4 4 4 4 4 4 4 4 4 4 4 4 4 5 5 5 5 AM DETECTOR FILTER ASSEMBLY CAPACITOR-FXD 1PF 1.25PF 200V CER CAPACITOR-FXD 4.7PF + .5F 200V CER CAPACITOR-FXD 1UF ±10% 50VDC MET-POLYE CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL CAPACITOR-FXD 200UF +75-10% 25VDC AL DIODE-GEN PRP 125MA DO-35 DIODE-GEN PRP 125MA DO-35 DIODE-PWR RECT 400V 1A CONNECTOR-RF SMA FEM PC 50-OHM Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. tvi 3048A Option K21 HEWLETT PACKARD 03048-92035 Page 15 of 21 TABLE 4- 1. REFER. DESIG. HP PART NUMBER A1J2 A1J3 A1J4 A1J5 A1J6 A1J7 A1J8 A1J9 A1J10 A1J11 A1J12 A1J13 A1J14 A1L1 A1MP1 A1R1 A1R2 A1R3 A1R4 A1R5 A1R6 A1R7 A1R8 A1S1 1250-2091 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 1251-1998 9100-2249 5041-0201 0757-0346 0757-0416 0698-7260 0757-0346 0757-0346 0757-0346 0757-0346 0757-0346 3101-2252 08640-20230 2200-0139 2200-0139 2200-0139 2200-0139 2200-0139 2200-0139 6960-0016 6960-0016 MP1 MP2 MP3 MP4 MP5 MP6 MP7 MP8 MP9 QTY 12 1 1 6 1 1 1 1 6 4 REPLACEABLE PARTS (cont'd) C D DESCRIPTION 5 3 3 3 3 3 3 3 3 3 3 3 3 6 6 2 7 2 2 2 2 2 2 3 6 6 6 6 6 6 6 0 0 CONNECTOR-RF SMA FEM PC 50-OHM CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BSC-SZ CONNECTOR-SGL CONT SKT .025-IN-BDC-SZ INDUCTOR RF-CH-MLD 150NH ±10% PUSHBUTTON 1/4 CHINA WHITE RESISTOR 10 1% -125W TF TC=0+100 RESISTOR 511 1% .125W TF TC=0±100 RESISTOR 10K 1% .05W TF TC=0±100 RESISTOR 10 1% -125W TF TC=0±100 RESISTOR 10 1% .125W TF TC=0±100 RESISTOR 10 1% .125W TF TC=0+100 RESISTOR 10 1% .125W TF TC=0±100 RESISTOR 10 1% .125W TF TC=0±100 SWITCH-PB DPDT ALTNG 4A 250 VAC FILTER OR AMPLIFIER HOUSING SCREW-MACH 4-40 .25-IN-LG PAN-HD-POZI SCREW-MACH 4-40 .25-IN-LG PAN-HD-POZI SCREW-MACH 4-40 .25-IN-LG PAN-HD-POZI SCREW-MACH 4-40 .25-IN-LG PAN-HD-POZI SCREW-MACH 4-40 .25-IN-LG PAN-HD-POZI SCREW-MACH 4-40 .25-IN-LG PAN-HD-POZI PLUG-HOLE TR-HD FOR .125-D-HOLE NYL PLUG-HOLE TR-HD FOR .125-D-HOLE NYL Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m 3048A Option K21 HEWLETT PACKARD 03048-92035 Page 16 of 21 TABLE 4-1. REFER. DESIG. MP10 MP11 MP12 MP13 MP14 MP15 MP16 MP17 MP18 HP PART NUMBER REPLACEABLE PARTS (cont'd) QTY 6960-0016 6960-0016 03048-02011 08665-21006 08665-21006 1250-0569 1250-0569 1250-2280 1250-2280 1 2 2 2 C D 0 0 8 7 7 8 8 4 4 DESCRIPTION PLUG-HOLE TR-HD FOR .125-D-HOLE NYL PLUG-HOLE TR-HD FOR .125-D-HOLE NYL AM DETECTOR FILTER HOUSING COVER SPACER SPACER NUT-RF CONN, 1/4-36 THD, 5/16-IN NUT-RF CONN, 1/4-36 THD, 5/16-IN WASHER-RF CONN WASHER-RF CONN SECTION V. SERVICE 5-1. INTRODUCTION This section contains information for troubleshooting and repairing the AM Detector Filter. Also included in this section are schematics and parts lists for the Impedance Matching Network and Calibration Load required to run the Performance Tests. 5-2. IMPEDANCE MATCHING NETWORK The Impedance Matching Network requires no periodic maintenance. If servicing is required, refer to the schematic diagram in Figure 5-1 on page 18 of this manual. 5-3. CALIBRATION LOAD The Calibration Load requires no periodic maintenance. If servicing is required, refer to the schematic diagram in Figure 5-3 on page 19 of this manual. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. r tvi 3048A Option K21 „.^7rJI PACKARD 5-4. 03048-92035 page 17 of 21 REPLACEMENTS Replacements for the Impedance Matching Network and Calibration Load can be built with the following procedure: 1. The parts required to build these devices are listed on pages 18 and 19. 2. Solder two SMC right angle pc board connectors (1250-0836) together as shown in Figures 5-2 and 5-4. 3. Cut the inside ground posts from the connectors. 4. Solder the resistors to the center and ground posts. 5. A resistor lead or buss wire must be connected between the two center posts and soldered as shown in Figure 5-4. 5-5. FUSES To protect the AM Detector Filter from a large dc voltage at the input, A1R1 acts as a fuse. If A1R1 is damaged, A1R4 through A1R8 are spare and can be used to replace A1R1. A1R1 and A1R4 through A1R8 are inserted into sockets for easy removal and replacement. Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. LV1 3048A Option K21 HEWLETT PACKARD 03048-92035 Page 18 of 21 FIGURE 5 - 1 . IMPEDANCE MATCHING NETWORK SCHEMATIC CUT GROUND POSTS R2 CUT GROUND POSTS SOLDER CONNECTORS TOGETHER FIGURE 5-2. REPLACEMENT IMPEDANCE MATCHING NETWORK TABLE 5-1. REFER. DESIG. Rl R2 REPLACEMENT IMPEDANCE MATCHING NETWORK PARTS LIST HP PART NUMBER QTY C D 0698-7205 0698-7244 1250-0836 1250-0836 1250-1694 1250-1697 1 1 2 2 1 1 0 7 2 2 2 5 DESCRIPTION RESISTOR 51.1 1% .05W TF TC=0±100 RESISTOR 2.15K 1% .05W TF TC=0±100 CONNECTOR-RF SMC M PC 50-OHM CONNECTOR-RF SMC M PC 50-OHM ADAPTER-COAX STR F-SMA F-SMC ADAPTER-COAX STR M-SMA F-SMC Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. 3048A Option K21 03048-92035 Page 19 of 21 tvi HEWLETT PACKARD FIGURE 5-3. CALIBRATION LOAD SCHEMATIC CUI GROUND POSTS SOLDER CONNECTORS TOGETHER CUT GROUND POSTS FIGURE 5-4. REPLACEMENT CALIBRATION LOAD TABLE 5-2. REPLACEMENT CALIBRATION LOAD PARTS REFER. DESIG. Rl R2 HP PART NUMBER 0698-7229 0698-7260 1250-0836 1250-0836 1250-1694 1250-1694 QTY 1 1 2 2 C D 8 7 2 2 2 2 DESCRIPTION RESISTOR 511 1% .05W TF TC=0±100 RESISTOR 10K 1% .05W TF TC=0+100 CONNECTOR-RF SMC M PC 50-OHM CONNECTOR-RF SMC M PC 50-OHM ADAPTER-COAX STR F-SMA F-SMC ADAPTER-COAX STR F-SMA F-SMC Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. tvi 3048A Option K21 03048-92035 HEWLETT PACKARD Page 20 of 21 » tt IX 02 <H H? h> <H M l« o| Hi H">l R6 |o Rf to C4 B o- C5 l l e C6 l! o C7 • 1 a c> o| HB to e I j C13 ' C11 e 1 1 C15 ■ CI6 - o / ■ ■ FIGURE 5-5. Al COMPONENT LOCATOR Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A. m HEWLETT PACKARD 3048A Option K21 03048-92035 Page 21 of 21 Copyright 1988 - HEWLETT-PACKARD COMPANY - Spokane Division East 24001 Mission Avenue, TAF-C-34, Spokane, WA 99220 U.S.A.