Download Complimentary Reference Material
Transcript
OPTICAL MEASURING INSTRUMENTS • MW0967B high-resolution unit Wavelength*1 850/1300 nm ±15 nm Fiber under measurement*10 50/125 µm GI multimode fiber (NA0.2) ITU-T G.651 Optical connector*11 FC, DIAMOND, ST, DIN, SC Pulse width Dynamic range oneway back-scattered light level*3,*4 5 ns 20 ns 100 ns 500 ns 2 µs Effective 9.0/7.0 dB 12.0/10.0 dB 15.5/13.5 dB 19.0/17.0 dB 21.5/20.0 dB 15.0/13.0 dB 18.5/16.5 dB 22.0/20.0 dB 24.5/23.0 dB SNR=1 12.0/10.0 dB Dynamic range (4% Fresnel reflection)*4 Effective 27/29 dB SNR=1 30/32 dB Near-end dead zone*5,*6 Fresnel reflection Spatial resolution*5,*7 32/34 dB 1.5 m 1.5 m 1.5 m 1.5 m Back-scattered light 3m 4.5 m 15 m 60 m 220 m Fresnel reflection 2m 4m 15 m 60 m 220 m Back-scattered light 2m 4m 15 m 60 m 220 m Not provided Variable optical output power function Provided Distance range (km)*5 10, 25, 50, 100 2.5, 5, 10, 25, 50, 100, 250, 500, 1 km (10 km range) 2.5, 5, 10, 25, 50, 100, 250, 500, 1 km, 2.5 km (25 km range) 2.5, 5, 10, 25, 50, 100, 250, 500, 1 km, 2.5 km, 5 km (50 km range) 2.5, 5, 10, 25, 50, 100, 250, 500, 1 km, 2.5 km, 5 km, 10 km (100 km range) Sampling resolution: 5 cm to 20 m Read-out resolution: 5 cm to 200 m Scale (m/div) Horizontal axis*5 Resolution Accuracy ±1m ±measured value (m) x 2 x 10–5 (does not include uncertainty fiber index of refraction) Scale (dB/div) 0.1, 0.25, 0.5, 1, 2.5, 5 Readout resolution 0.001 dB Linearity ±0.05 dB/dB Ambient temperature –10° to +55°C (spec. meet), –40° to +75°C (storage) Mass ≤2.5 kg Not applicable in the variable optical output power mode *1:2: Please specify one of these types when ordering. Please contact us for other * connectors. (However, the dynamic range is degraded by 0.5 dB for DIAMOND * 29/31 dB 1.5 m Mask function Vertical axis * and D4 connectors.) 3: Dynamic range (one-way back-scattered light) Effective: The difference between the level of the point which is 0.3 dB higher than the peak noise level and the level of the point where near-end back-scattering occurs. SNR=1: The level difference between the RMS noise level and the level where near end back-scattering occurs. resolution *7: Spatial Fresnel reflection: The width of an unsaturated Fresnel reflection pulse at the point that is 1.5 dB less than the peak value. Back-scattered light: The distance between the points where the beginning and ending levels at a splice etc. (≤1 dB) are within ±0.1 dB of their initial and final values, respectively. Spatial resolution (Fresnel reflection) Level Effective 1.5 dB SNR = 1 0.3 dB ±0.1 dB Distance are obtained using smoothing (level 6). With no smoothing, all values are *4: Values reduced by 2 dB. the index of refraction is set to 1.500000. *5:6: When Near-end dead zone * Fresnel reflection: The minimum distance at which the 4% Fresnel reflection generated by the fault can be detected. (MW0944B with built-in variable optical output power function used.) Back-scattered light: The near-end dead zone (for back-scattered light) is the distance at which the near-end back-scattered light level approaches ±0.5 dB of its final value. — For the MW0944B: This specification represents the values for the FC-PC connector (when return loss ≥25 dB). When a fiber with an FC connector (flat polished) is measured, the dead zone may be larger than the specified value. The variable near-end mask width function can be used to suppress dead zone widening to 2 to 3 m. ≤1 dB ±0.1 dB Spatial resolution (back-scattered light) masks including the near-end mask (except MW0945B, MW0946B and *8: All MW0947B) are OFF in the variable optical output mode. 9: Please specify one of these types when ordering. Please contact us for other * connectors. (However, the dynamic range is degraded by 0.5 dB for DIAMOND, D4, and AT&T Biconic connectors.) ±0.5 dB The dynamic range is increased by about 1.5 dB when measuring 62.5/125 µm *10: (NA 0.29) fibers. The transmission loss measurement result may differ from that obtained with NA 0.29 by as much as 0.1 dB/km. Level Please specify one of these types when ordering. Please contact us for other *11: connectors. Distance Dead zone (back-scattered light) 62