RECEIPT INSPECTION
Upon receipt of the pump, inspect it carefully for
damage and check it against the issue receipt. Report
any damage or faults immediately to the local
representative of the transporter and send a copy to
IMBIL, which should be received in writing within one
month from the receipt of the equipment. Inspect the
protective layer of the various parts, and if necessary,
apply further protection to the areas where it has
already been torn. Inspect all painted surfaces. If
necessary, retouch the areas where the paint may have
chipped or scratched. Inspect all the lids on the
discharge flanges and pipe connections for damage or
clearance. If necessary, remove the lids and inspect the
accessible inner areas visually for the accumulation of
foreign materials or water. If necessary, clean and
conserve the inner parts, as mentioned above, and
replace the lids and tighten securely.
NOTE: When unpacking, take care not
to drop any boxes or packaging with
accessories or spare parts that may be
attached to the crate
TRANSPORTATION
Lift the entire unit using appropriate lifting techniques
(Fig. A). Properly trained staff should perform the
lifting in accordance
with local regulations. The driver and pump weights are
given in the General Arrangement design of the
purchased equipment.
 The complete pump unit may not be swung when
raised. Always introduce a support so that the pump
does not turn.
 Ensure that the equipment used for lifting is able to
support the weights found, and that the parts are
completely secure before lifting.
 Remove the coupling and the spacer before lifting
the complete unit. Always raise using the 4 lifting
supports supplied at the base for lifting the unit.
 Do not lift the pump, engine and base from the pump
and wing screw on the engine.
To lift the driver: follow the manufacturer's
instructions.
To lift units assembled at the base with or without
drivers: Attach the lifting straps through the lifting
brackets provided at the base (Figure A) with a suitable
lifting device for lifting the unit uniformly, without
turning to one side or the other.
To lift the pump only: Attach the lifting straps to the
bearing blocks of the pump, passing through the cooling
pipe. Raise the pump uniformly (without turning) with
adequate lifting equipment (Fig. b).