15.Commissioning Cont.
0
21
3
18
6
9
15
12
Figure 15.29
Turning knob 7 can change the heating
delivery temperature ± 27°F (15°C) with
respect to the one set by the external probe
K coefficient.
Figure 15.31
Press the button
to display the K REG
window (Figure 15.32).
C.h. flow
temperature °F
176
+ 15 °C
158
140
122
K = 1,5
Figure 15.32
104
-15 °C
86
68
68
59
50
41
32
23 14 5
-4 -13
External temperature °F
Figure 15.30
The temperature trend as the knob position
is changed with K 1.5 is shown in Figure
15.30.
Sequence for setting the K coefficient
with the remote connected
Programming the REMOTE, the K coefficient
setting can be selected.
• Power the boiler electrically.
• Press the button for more than 3 seconds
to enter the mode
(Figure 15.31).
51 RIVA ADVANCE COMBI MANUAL
The buttons
and
can be used to
change the value.
Press the button to exit the mode
(Figure 15.32).