Download product specifications - HVAC Warehouse Direct

Transcript
L2
BK
R
BK
M2
M1
PU
WH
BL
BK
RD
BK
9
8
7
6
5
4
3
2
1
PLM
ONE (1) ELEMENT ROWS
RD
HTR1 TL
L1
RD
BK
L2
FL
FL
BK
M2
BK
RD
R
M1
M4
M3
PU
WH
BL
BK
RD
RD
BK
9
8
7
6
5
4
3
2
1
PLM
TWO (2) ELEMENT ROWS
RD
HTR1 TL
HTR2 TL
L1
BK
RD
L2
BK
L2
RD
M2
BK
M2
M4
R2
WH
PU
BR
RD
BL
BK
9
8
7
6
5
4
3
2
1
PLM
THREE (3) ELEMENT ROWS
RD
YL
R1
M1
M3
RD
BL
RD
HTR2 TL
YL
BK
HTR1 TL
HTR3 TL
M1
BK
L1
YL
FL
FL
FL
L1
BK
RD
L2
FL
L1
YL
BL
HTR3 TL
HTR2 TL
HTR1 TL
M2
L2
RD
BL
BK
M6
M5
PU
BL
YL
R2
M8
M7
BL
RD
BK
WH
BR
RD
BL
BK
FOUR (4) ELEMENT ROWS
RD
YL
R1
M4
M3
BK RD
HTR4 TL
M1
BK
FL
FL
FL
9
8
7
6
5
4
3
2
1
PLM
WH
RD
IF REPLACEMENT OF THE ORIGINAL WIRES
SUPPLIED WITH THIS ASSEMBLY IS NECESSARY,
USE WIRE THAT CONFORMS TO THE
NATIONAL ELECTRIC CODE.
COPPER
OR ALUMINUM
COPPER
POWER
SUPPLY
POWER SUPPLY
(SEE(SEE
RATING
RATINGPLATE)
PLATE)
USE
MIN.
75°
FIELD WIRE
USE MIN. 75°C CFIELD
WIRE
RD
GR
BL
RD
GR
CR
RD
WH
BR
3
1
BL
5
2
4
R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5
SEE
NOTE 3
BL
WH
PU
PLF
PLM
TERMINAL BLOCK SHOWN
FOR 50HZ MODELS ONLY
RD
BK
RD
2
2
C
BK
3
3
BL
RD
BK
RD
L2
1
1
BK
L1
2
24V
1
5
BL
4
4
GRD
4
3
WH
6
6
RD
BK
FUSE
HOLDER
BL
TR
240
7
7
BL
8
8
9
9
C L GN
EM
123 45
OR BR YL
WH PU
SEE
NOTE 4
SEE NOTE 1
BL
RD
BR
5
5
EQUIPMENT
GROUND
EQUIPMENT GROUND
USE COPPER
OR ALUMINUM
WIRE
USE COPPER
WIRE
4
6
24V
2
5
5
3
4 PLF
3
SEE NOTE 1
1
COLOR CODE
WIRING CODE
2
2
CR
4
5
Notes:
1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts.
2) See composite wiring diagrams in installation instructions
for proper low voltage wiring connections.
3) Confirm speed tap selected is appropriate for application. If speed tap needs
to be changed, connect purple wire from terminal 4 of CR relay to appropriate tap
at TB
4) Brown and white wires are used with Heat Kits only.
TRANSFORMER
FEMALE PLUG CONNECTOR
MALE PLUG CONNECTOR
FUSE LINK
THERMAL LIMIT
HEAT ELEMENTS
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
EVAPORATOR MOTOR
TR
TERMINAL BOARD
PLF
RELAY
PLM
FL
CONTROL RELAY
TL
ELECTRONIC BLOWER TIME
HTR
DELAY RELAY
COMPONENT CODE
GREEN
PURPLE
BROWN
WHITE
L2
PLM 2
PLF
R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5
1
C L GN
EM
208/240 VOLTS
BK BLACK
GR
RD RED
PU
YL YELLOW BR
BL BLUE
WH
TR
EM
TB
R
CR
EBTDR
1 PLF
1 PLM
L1
FUSE
HOLDER
SEE NOTE 2
1
2
3
4
5
0140A00037
REV B
C
EM
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE
PROVIDED ABOVE.
MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
L1
BK
FL
WIRING DIAGRAMS
ASPF******BA
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
37