Download product specifications - HVAC Warehouse Direct
Transcript
L2 BK R BK M2 M1 PU WH BL BK RD BK 9 8 7 6 5 4 3 2 1 PLM ONE (1) ELEMENT ROWS RD HTR1 TL L1 RD BK L2 FL FL BK M2 BK RD R M1 M4 M3 PU WH BL BK RD RD BK 9 8 7 6 5 4 3 2 1 PLM TWO (2) ELEMENT ROWS RD HTR1 TL HTR2 TL L1 BK RD L2 BK L2 RD M2 BK M2 M4 R2 WH PU BR RD BL BK 9 8 7 6 5 4 3 2 1 PLM THREE (3) ELEMENT ROWS RD YL R1 M1 M3 RD BL RD HTR2 TL YL BK HTR1 TL HTR3 TL M1 BK L1 YL FL FL FL L1 BK RD L2 FL L1 YL BL HTR3 TL HTR2 TL HTR1 TL M2 L2 RD BL BK M6 M5 PU BL YL R2 M8 M7 BL RD BK WH BR RD BL BK FOUR (4) ELEMENT ROWS RD YL R1 M4 M3 BK RD HTR4 TL M1 BK FL FL FL 9 8 7 6 5 4 3 2 1 PLM WH RD IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMBLY IS NECESSARY, USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. COPPER OR ALUMINUM COPPER POWER SUPPLY POWER SUPPLY (SEE(SEE RATING RATINGPLATE) PLATE) USE MIN. 75° FIELD WIRE USE MIN. 75°C CFIELD WIRE RD GR BL RD GR CR RD WH BR 3 1 BL 5 2 4 R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 SEE NOTE 3 BL WH PU PLF PLM TERMINAL BLOCK SHOWN FOR 50HZ MODELS ONLY RD BK RD 2 2 C BK 3 3 BL RD BK RD L2 1 1 BK L1 2 24V 1 5 BL 4 4 GRD 4 3 WH 6 6 RD BK FUSE HOLDER BL TR 240 7 7 BL 8 8 9 9 C L GN EM 123 45 OR BR YL WH PU SEE NOTE 4 SEE NOTE 1 BL RD BR 5 5 EQUIPMENT GROUND EQUIPMENT GROUND USE COPPER OR ALUMINUM WIRE USE COPPER WIRE 4 6 24V 2 5 5 3 4 PLF 3 SEE NOTE 1 1 COLOR CODE WIRING CODE 2 2 CR 4 5 Notes: 1) Red wires to be on transformer terminal "3" for 240 volts and on terminal "2" for 208 volts. 2) See composite wiring diagrams in installation instructions for proper low voltage wiring connections. 3) Confirm speed tap selected is appropriate for application. If speed tap needs to be changed, connect purple wire from terminal 4 of CR relay to appropriate tap at TB 4) Brown and white wires are used with Heat Kits only. TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE EVAPORATOR MOTOR TR TERMINAL BOARD PLF RELAY PLM FL CONTROL RELAY TL ELECTRONIC BLOWER TIME HTR DELAY RELAY COMPONENT CODE GREEN PURPLE BROWN WHITE L2 PLM 2 PLF R C G W1 W2 Y1 Y2 O DH 1 2 3 4 5 1 C L GN EM 208/240 VOLTS BK BLACK GR RD RED PU YL YELLOW BR BL BLUE WH TR EM TB R CR EBTDR 1 PLF 1 PLM L1 FUSE HOLDER SEE NOTE 2 1 2 3 4 5 0140A00037 REV B C EM NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE. MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. L1 BK FL WIRING DIAGRAMS ASPF******BA HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 37