Engine Operating Guidelines
BREAK-IN SERVICE
The engine is ready for normal operation. However,
extra care during the first 100 hours of operation will
result in more satisfactory long-term engine
performance and life. DO NOT exceed 100 hours of
operation with break-in oil.
1. This engine is factory-filled with John Deere Engine
Break-in Oil. Operate the engine at heavy loads
with minimal idling during the break-in period.
2. If the engine has significant operating time at idle,
constant speeds, and/or light load usage, or
makeup oil is required in the first 100 hour period, a
longer break-in period may be required. In these
situations, an additional 100 hour break-in period is
recommended using a new change of John Deere
Engine Break-In Oil and a new John Deere oil filter.
IMPORTANT: DO NOT add makeup oil until the oil
level is BELOW the ADD mark on
dipstick. John Deere Engine Break-In
Oil (TY22041) should be used to make
up any oil consumed during the
break-in period.
3. Check engine oil level more frequently during
engine break-in period. If oil must be added during
this period, John Deere Engine Break-In Oil is
preferred. See ENGINE BREAK-IN OIL, in Fuels,
Lubricants, and Coolant Section.
IMPORTANT: DO NOT use PLUS-50 Engine Oil
during the break-in period of a new
engine or engine that has had a major
overhaul. PLUS-50 oil will not allow a
new or overhauled engine to properly
wear during this break-in period.
RG8009
A
RG7330
ENGINE SPECIFICATIONS*
Oil Pressure at Full Load Rated Speed . . . . . . . . . . . . 345 ± 103 kPa
(3.45 ± 1.03 bar) (50 ± 15 psi)
Minimum Oil Pressure at Rated Speed . . . . . . . . . . . . 275 (2.75 bar)
(40 psi)
IMPORTANT: DO NOT fill above the crosshatch
pattern (A) or the FULL mark,
whichever is present. Oil levels
anywhere within the crosshatch are
considered in the acceptable
operating range.
Minimum Oil Pressure at 850 rpm . . . . . . . . . . . . 103 kPa (1.03 bar)
(15 psi)
Coolant Temperature Range. . . . . . . . . . . . 82°–94° C (180°–202° F)
* At normal operating temperature of 115 ° C (240 ° F) sump.
33