Download Ceiling Cassette Air Conditioner SVC MANUAL(Exploded View)
Transcript
http://biz.lgservice.com Ceiling Cassette Air Conditioner SVC MANUAL(Exploded View) MODEL : LT-H488DLE1 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 1. Specification Indoor Indoor Unit Type Models Decorative Panel Model Power Supply Cooling Capacity Heating Capacity Current Fan Nominal Running Current Motor Type Fan Type Motor Output(W) x No. of Unit Air Flow Rate (H / M / L) External Static Pressure Capacitor Drive Coil Row x Column x FPI Dimensions (W x H x D) Body Decorative Panel Net Weight Body Decorative Panel Air Filter Sound Level (H / M / L / SL) Piping Liquid Connections Gas Drain(OD/ID) Dehumidification Rate Safety Devices Temperature Sensor Referigerant Referigerant Control Connectable Outdoor Unit Power and Transmission Interunit Cable Ceiling Cassette LTNH488DLE1 PT-HDA1 Ø / V / Hz kW Btu/h kW Btu/h A CMM cfm mmAq µF / Vac mm(inch) mm(inch) kg (lbs) kg (lbs) dB(A)+3 mm (inch) mm (inch) mm l/h No. x mm2 3/380~415/50 14 47,770 15.2 51,865 0.4 BLDC Turbo 124*1 31/29/27 1094/1024/953 680/400 Direct 2R*12C*19FPI 840*840*288(33.1*33.1*11.3) 950*950*30(37.4*37.4*1.2) 31/68.3) 5(11) Long Life Filter 45/44/42/41 9.52(3/8) 19.05(3/4) 32/25 2.4 Fuse, Thermal Protector Thermistor R22 Capillary Tube LTUH488DLE1 5* 3.5 ( 5* 0.75) Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB - Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB - Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. 2 Ceiling Cassette Air Conditioner Conversion Formula kW = Btu/h x 0.0002931 cfm = CMM x 35.3 Outdoor Outdoor Unit Nominal Capacity (Min~Rating~Max) Cooling Heating Nominal Input Cooling (Min~Rating~Max) Heating Testing Combination Running Current(Rating) Cooling Heating Starting Current Cooling/Heating Power Supply Power Supply Cable(Outdoor) Power and Transmission Cable (Outdoor to Indoor or Outdoor to BD) Power and Transmission Cable(BD to Indoor) Dimensions WxHxD Net Weight Max. Number of Connectable Indoor Units Compressor (#1) Type Qty x Model Motor type Oil charge volume Oil Type Compressor (#2) Type Qty x Model Motor type Oil charge volume Oil type Compressor (#3) Type Qty x Model Motor type Oil charge volume Oil type Refrigerant Cycle A Charge (at 7.5m) Cycle B Charge (at 7.5m) Type Control Additional Refrigerant Charge Heat Exchanger (Rows x Column x FPI) x No. Defrosting Method Fan Capacitor Drive Discharge Direction(Side/Top) Air Flow RatexNo. of Fan Sound Level(H/L) Sound Pressure Piping Connections Liquid(Cycle A) Gas(Cycle A) Liquid(Cycle B) Gas(Cycle B) High Pressure Gas Max. Interunit Total Piping Piping Length Main Piping Total Branch Piping Each Branch Piping Max. Elevation Outdoor Unit~Indoor Unit Difference Indoor Unit~Indoor Unit Operation Range Cooling (Outdoor) Heating LTUH488DLE1 14 47,770 15.2 51,865 4.9 4.9 8.5 8.7 3/380-415/50 5*3.5(Including Earth) 5*0.75(Including Earth) kW Btu/h kW Btu/h kW kW A A A Ø / V / Hz No. x mm2 No. x mm2 No. x mm2 mm(inch) kg(lbs) cc cc cc g(oz) g(oz) g/m(oz/ft) µF/Vac CMM(cfm) dB(A)+3 mm(inch) mm(inch) mm(inch) mm(inch) mm(inch) m m m m m m °C(°F) °C(°F) 1130*900*370 (44.5 *35.4*14.5) 105(231) 1 SCROLL 1 * SB061YAA Induction 1,650 SUNISO 4GSI 3,700(130.5) R22 Capillary Tube 45(0.48) (2R*22C*18FPI)*2 Reversing Cycle 6/370-400 Direct Side 110(3885) 59 9.52(3/8) 19.05(3/4) 50 30 21~54 -7~24 Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB - Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB - Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without notic for purpose of improvement. Conversion Formula kW = Btu/h x 0.0002931 cfm = CMM x 35.3 Service Manual 3 2. List of Functions Indoor Category Function Air Supply Outlet Airflow Direction Control (left & right) Airflow Direction Control (up & down) Auto Swing (left & right) Auto Swing (up & down) Air flow Airflow Steps(Fan / Cool / Heat) CHAOS Swing CHAOS Wind (Auto wind) Jet Cool (Power Wind) Swirl Wind Deodorizing Filter Air Purifier Plasma Air Purifier Prefilter(Washable / Anti-Fungus) Drain Pump E.S.P. Control Installation Electric Heater(Operation) High Ceiling Operation Hot Start Reliability Self Diagnosis Soft Dry Operation Auto Changeover Auto Cleaning Auto Operation (Artificial Intelligence) Auto Restart Operation Child Lock Convenience Forced Operation Group Control Sleep Mode Timer (On/Off) Timer (weekly) Two Thermistor Control Standard Wired Remote Controller Deluxe Wired Remote Controller Individual Simple Wired Remote Controller Control Wired Remote Controller(for hotel use) Wireless Remote Controller(simple) Wireless LCD Remote Controller General Central Controller(Non LGAP) CAC Dry Contact Network Network Soluation(LGAP) Function PDI(Power Distribution Indicator) PI485 Zone Control Special Function CTIE Kit Electro Thermostat Thermistor Others LTNH488DLE1 4 Auto X O 4/5/4 X O O O X OPTION O O O O O O O X O O O O O O O O O O X X X X ACCESSORY(PQWRHSF0) X OPTION O X ACCESSORY(PMNFP14A0) X X X - Note : O : Applied, X : Not applied, – : No relation Option: Model name & price are different according to options, and assembled in factory with main unit. Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Skip over evaporator sensing means that the function of knock-off to prevent freezing is skipped, when IDU start cooling mode. 4 Ceiling Cassette Air Conditioner Outdoor Category Reliability Convenience CAC Network Function Special Function Kit Others Function Defrost / Deicing High Pressure Switch Low Pressure Switch Phase protection Restart Delay (3-minutes) Self Diagnosis Soft Start Test Function Auto Changeover Auto Restart Operation Central control(LGAP) PDI(Power Distribution Indicator) PI485 Low Ambient Kit Thermistor LTNH488DLE1 O O X O O O X O O O O X X ACCESSORY - Note : O : Applied, X : Not applied, – : No relation Option: Model name & price are different according to options, and assembled in factory with main unit. Accessory: Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. Service Manual 5 3. Piping Diagrams Indoor Unit Outdoor Unit Capillary Tube Th2 Liquid Side Capillary Tube 3-Way Valve Th1 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th3 Gas Side Reversing Valve 3-Way Valve High Pressure S/W Cooling Heating Compressor LOC. Description PCB Connector Th1 Thermistor for indoor air temperature CN_ROOM Th2 Thermistor for evaporating temperature CN_PIPE1 Th3 Thermistor for condensing temperature Deice PCB 6 Ceiling Cassette Air Conditioner 4. Wiring Diagrams Indoor Unit 0.7 CN-POWER CN-DPUMP CN-MOTOR2 CN-FLOAT CN-ROOM CN-PIPE1 CN-REMO CN-VANE2 CN-VANE1 CN-DISP Service Manual 7 Outdoor Unit Anti phase PCB Magnetic Contactor Fuse Fan Capacitor 8 Ceiling Cassette Air Conditioner Deice PCB Connecting wire Terminal block Main Power Terminal Block 5. Exploded View Indoor Unit 130400 249951 W6640 268711 ROOM W49810 354211 PIPE 263230-1 349480 552111 352118 330860 330870 158591 Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,) Service Manual - 9 - Please check the service part of front panel by model name(PT-HDA1) 130412 130911-3 346810 359012 130911-4 130911-2 352150 130911-1 267110 249310 Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,) - 10 - Ceiling Cassette Air Conditioner 552203-2 W6920 430411 566001 435511 437211 435301 435512 559010 137213 546810 549610 447900 554031 649950 W0CZZ 268711 554160 148000 DEICE 552117 561410 552116 263230-4 552115-1 552203-1 552115-2 552115-3 437212 Outdoor Unit Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://biz.Lgservice.com,) Service Manual - 11 - P/NO : MFL33061306 FEBRUARY, 2007 P/NO : MFL33061306 AUGUST, 2007