14.3.3
7-segment "Status" display
Encoded errors are displayed in a 7-segment display on the CPS3. The display alternates between the first
and second digit at brief intervals:
Display
Duration
Pause
1st digit
0.5 s
0.2 s
2nd digit
0.5 s
1s
1st digit
0.5 s
0.2 s etc.
A period (.) in the display means NO error.
If several errors occur, the error with the highest priority is displayed, i.e. with the lowest number.
No information about faults and malfunctions that are detected by the CPS3 is transmitted to the
mPro400GC-M by ARCNET and displayed in the screen there.
Display
14
Error
Description
Possible causes
Measures and
remedies
0-0
Error loading the intermediate circuit capacitors
after switching on
Short circuit in the intermediate
circuit CPS3
➔
Replace the CPS3
•
Cables
➔
Check the cables for short
circuiting between contacts
1 and 2 on the plug connectors and replace if necessary
•
TSE/TUSE
➔
Replace the TSE/TUSE
•
Main relay (Q4 or Q5 in PM)
does not switch
➔
Check the main relay,
replace if necessary
➔
Check phases
➔
Check mains supply
Safety relay PNOZ K2 in the
power module has triggered an
emergency stop
➔
Check the emergency stop
circuit
➔
Read the operating
instructions for the
PNOZ type X3P
Relay Q2 or Q3 has not
switched
➔
Check the relay,
replace if necessary
Supply voltage
➔
Check the supply voltage
•
➔
Check mains supply
0-1
Faulty supply 3 x 270 VAC
Phases missing
•
58
is too high,
U phase – phase > 300 VAC
too low,
U phase – phase < 240 VAC
0-2
Excess current or short
circuit on braking chopper
Braking current > 200 A:
Short circuit in the braking
resistor
➔
Replace the CPS3
0-4
Braking chopper overload
Braking resistor is overloaded.
The braking power is
> 100 Weff.
Excessive number of DGD-IS.
➔
Reduce the number of
mPro400GC-M
P2077SB/EN 2010-11
DGD-IS is powered externally
➔
Check the mechanics
of the fastening station
77l_Fehlersuche-en.fm, 16.12.2010