Download HDS Powersports User Guide

Transcript
Honda POWERSPORTS HDS USER GUIDE
SHIFT CONTROL MOTOR MINUS TERMINAL
VOLTAGE
Shift Control Motor Minus (-) Terminal Voltage
Reference values: 0 - 24.5 V
SHIFT CONTROL MOTOR PLUS TERMINAL
VOLTAGE
Shift Control Motor Plus (+) Terminal Voltage
Reference values: 0 - 24.5 V
NO. 1 LINEAR SOLENOID VALVE CURRENT
No. 1 Linear Solenoid Valve Current
Reference values: 0 - 2.0 Amp
0~5 V/0~2 A converted, No. 1 linear solenoid valve current signal.
NO. 2 LINEAR SOLENOID VALVE CURRENT
No. 2 Linear Solenoid Valve Current
Reference values: 0 - 2.0 Amp
0~5 V/0~2 A converted, No. 1 linear solenoid valve current signal.
SHIFT SPINDLE ANGLE SENSOR
Shift Spindle Angle Sensor
Reference values: 0 - 5.0 V
Shift spindle angle sensor detects shift spindle angle and converts
the information into a voltage signal that is sent to PCM.
NO. 1 CLUTCH GEAR POSITION
Reference values: NEUTRAL/1st/HALF NEUTRAL/3rd/UNDER
SHIFT/5th
(i)
No.1 clutch gear position
(ii) No.2 clutch gear position
(iii)
(A)
(B)
(1)
(2)
(3)
(4)
(5)
Gear position
Neutral
Half neutral
1st
2nd
3rd
4th
5th
No. 1 clutch gear position is output. Gear position is determined
according to No. 1 and No. 2 clutch gear position combination.
49