11 Fault diagnosis and rectification 11.6 Other errors/malfunctions Malfunction sign Possible cause Solution The auxiliary heating system does not work even though it has been enabled by the controller (e. g. during the switch-off time by the power supply operator (energy supply company switch-off time)), the heating system or the DHW tank do not reach the desired temperature. The auxiliary heating system is connected on a low-rate tariff and this tariff has just been blocked by the power supply operator. > Check whether the auxiliary heating is on a low-rate tariff and a power company blockage is in effect. The auxiliary heating safety thermostat has triggered. > Release the safety thermostat by pressing the pushbutton. Possible causes if the thermostat trips again: Air in the heating system. Blocked dirt filter in the return of the heating system. > Bleeding heating circuit. Clean the blocked dirt filters. The heating pump has stopped or is running too slowly. > Check the heating pump and replace if necessary. Air in the heating circuit. > Bleeding heating circuit. Dirt in the heating circuit. > Flush the heating circuit. Bivalent temperature incorrectly set. > Change the bivalent temperature (Menu A3) ¬ Tab. 9.9. Pump output of the external heating pump has dropped or pump is faulty. > Check functioning of the pump; replace if necessary. The condensate drain is blocked. > Condensate inside the unit is collected in the condensate pan and may be discharged under the heat pump (not a fault). Check the line insulation inside the unit, and re-insulate if necessary in order to reduce condensate formation. Leaks in the heating circuit. > Check the heating circuit components (pump, auxiliary heating system, pipes) for leaks. > If necessary, retighten the screw couplings and replace the seals. Outside temperature indicates -60 ºC. Outside temperature sensor not connected or faulty. > Check outside temperature sensor. Temperatures in the heating circuit too low or too high. Target room temperature not optimally set. > Change the target room temperature (Menu 1, ¬ operating instructions). Night set back temperature not optimally set. > Change the night set back temperature (Menu 1, ¬ operating instructions). Heating curve not optimally set. > Change the heating curve (Menu C2) ¬ Tab. 9.6 Noise in the heating circuit. Traces of water under or next to the heat pump. 11.5 Other errors/malfunctions 108 Installation instructions geoTHERM 0020051574_03