Download geoTHERM - Vaillant

Transcript
Appendix 17
17
Appendix
Sensor characteristics
External heat pump temperature sensors VR 10
Internal heat pump temperature sensors VR 11
Temperature (°C)
Resistance (ohms)
Temperature (°C)
Resistance (ohms)
-40
87879
-40
327344
-35
63774
-35
237193
-30
46747
-30
173657
-25
34599
-25
128410
-20
25848
-20
95862
-15
19484
-15
72222
-10
14814
-10
54892
-5
11358
-5
42073
0
8778
0
32510
5
6836
5
25316
10
5363
10
19862
15
4238
15
15694
20
3372
20
12486
25
2700
25
10000
30
2176
30
8060
35
1764
35
6535
40
1439
40
5330
45
1180
45
4372
50
973
50
3605
55
807
55
2989
60
672
60
2490
65
562
65
2084
70
473
70
1753
75
400
75
1481
80
339
80
1256
85
289
85
1070
90
247
90
916
95
212
95
786
100
183
100
678
105
158
105
586
110
137
110
509
115
120
115
443
120
104
120
387
125
92
125
339
130
81
130
298
135
71
135
263
140
63
140
232
145
56
145
206
150
50
150
183
155
44
155
163
17.1 Appendix, VR 10 sensor characteristics
Installation instructions geoTHERM 0020051574_03
17.2 Appendix, VR 11 sensor characteristics
121