Download LG Large Duct-Type Air Conditioner
Transcript
LG Large Duct-Type Air Conditioner SERVICE MANUAL MODELS: AB-H1208VA0 Contents Model Number Nomenclature...............................................................................................2 General Data ..........................................................................................................................3 Dimensions ............................................................................................................................5 Wiring Diagram ......................................................................................................................6 Troubleshooting Guide .........................................................................................................7 Features of Controller .........................................................................................................24 Exploded View and Replacement Parts List .....................................................................28 Model Number Nomenclature AB-H1208VA0 Development Sequence A: Basic Type Chassis Name V: BV Chassis Electric Standard (Volts / Freq. / Phase) 8: 380-415V, 50Hz, 3Ø Cooling Capacity 120: 120,000 Btu/h Model Type H: Heat Pump Type of Air Conditioner A: Changwon, R-410A B: Duct -2- General Data Indoor units Indoor unit type Ducted Type Model AB-H1208VA0 [B120AH SV0] Power supply Gross cooling capacity Net cooling capacity Heating capacity Current Fan Ø/V/Hz 3 / 380 - 415 / 50 kW 34.3 Btu/h 117,000 kW 32.8 Btu/h 112,000 kW 38.1 Btu/h 130,000 A 2.05 Rated running current Motor type BLDC Fan type Sirocco fan Motor output (W) x Number of unit 1,491 x 1 Air flow rate(H/M/L) CMM 105/97/90 CFM 3,708/3,426/3,179 External static pressure mmAq 20 Capacitor µF/V(ac) - Drive Coil Rows x Column x FPI Dimensions(WxHxD) Body Weight Body Direct drive mm 3R x 24C x 17 mm(inch) 1,600 x 720 x 800(63.0 x 28.3 x 31.5) kg(lbs) 130(287) Air filter prefilter Sound level (H/M/L) dB(A)+3 53/51/49 Piping Liquid mm(inch) 15.88(5/8) connections Gas mm(inch) 28.58(11/8) mm 34/28 l/h 10 Drain(OD/ID) Dehumidification rate Safety devices - Temperature sensor Thermistor Referigerant R410A Referigerant control LEV Connectable outdoor unit Single Power supply cable (indoor) No.x mm2 4 x 1.25 Transmission interunit cable(indoor to outdoor) No.x mm2 2 x 1.25 Note : 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB - Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB - Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. Gross cooling capacity = Net cooling capacity + Heat of evaporator fan motor. -3- Conversion Formula kW = Btu/h × 0.0002931 CFM = CMM × 35.3 General Data Outdoor units AB-H1208VA0 [B120AH SV0] Outdoor unit Rated capacity Gross cooling Net cooling Heating Rated input Cooling Heating kW Btu/h kW Btu/h kW Btu/h kW kW 34.3 117,000 32.8 112,000 38.1 130,000 14.5 12.5 - A A A A Ø / V / Hz No. x mm2 No. x mm2 24 21 3 / 380 - 415 / 50 5 x 8.5 2 x 1.25 mm(inch) 1,280 x 1,520 x 730(50.4 x 59.8 x 28.7) kg(lbs) 300(661) Energy label Running current Starting current Cooling Heating Cooling Heating Power supply Power supply cable (outdoor) Transmission interunit cable (outdoor to indoor) Dimensions WxHxD Net weight 1 Max. number of connectable indoor units Scroll Type 1 x AR073YAB Compressor (Constant) Qty x model 1 x AR081YAB PSC Motor type Oil charge volume 2,325 x 2 cc FVC68D(PVE) Oil type Charge(at 7.5m) Refrigerant Type Heat Exchanger Rows x Column x FPI 8,000(282.2) g(oz) R410A LEV Control 2R x 88C x 17 Reversing cycle Defrosting method µF/V(ac) 10/450 Discharge direction Side / Top Top discharge Air flow rate x No. of fan CMM(CFM) 180(6,400) dB(A)+3 65 Capacitor Fan Sound level Piping connections Direct drive Drive Sound pressure at 1m Liquid(Ø) mm(inch) 15.88(5/8) Gas(Ø) mm(inch) 28.58(11/8) Max. piping length Indoor unit~Outdoor unit m 50 Max. elevation Indoor unit~Outdoor unit m 30 Note : 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB - Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB - Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB Piping Length - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. Gross cooling capacity = Net cooling capacity + Heat of evaporator fan motor -4- Conversion Formula kW = Btu/h × 0.0002931 CFM = CMM × 35.3 Dimensions Model No.: AB-H1208VA0[B120 SV0] 1700 1600 798 837 1. Indoor Unit 1392.4 2. Outdoor Unit 662 712 509 398 544 900(bolt hole) 190 690 Air outlet 48 730 700(bolt hole) 15 1280 190 Air inlet 1444 1555 Air inlet 670 Service Panel 33 63 100 160 Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe) 45 Knockout hole (For the control wiring, the power supply, refrigerant connecting pipe) -5- 60 Wiring Diagram 1. Indoor Unit REACTOR BLDC DRIVER CN_ROOM MAIN PCB CN_U CN_V CN_W RETURN AIR THERMISTOR CN_POWER CN_ REACTOR2 RD CN_REMO CN_ REACTOR1 YL BR CN_PWR THERMISO EVA IN CN_START EVA OUT CN_N THERMISO CN_T CN_PIPE2 CN_S CN_BLDC CN_COMM CN_R CN_PIPE1 CN_SER INDOOR MOTOR 1 2 3 4 5 6 BR RD YL NOISE FILTER N2 N1 T2 T1 S2 S1 R2 R1 FIRE ALARM FUSE (600V,15A) REMOTE CONTROLLER 1(R) NOTE FIELD WIRING FACTORY WIRING BK:BLACK RD:RED BR:BROWN WH:WHITE OR:ORANGE YL:YELLOW BL:BLUE 3854A21016A 2(S) 3(T) 4(N) 5(C) To Outdoor Unit Notes: BK BR BL BLACK BROWN BLUE FACTORY WIRING OR RD GN/YL ORANGE RED GREEN/YELLOW OPTIONAL WIRING YL WH COMP 2. Outdoor Unit LEV1 LEV2 M M Relay for Outdoor Motor Magnetic Contactor CN_3PHASE CN_COMP Crankcase Heater CN_LE V1 CN_LE V2 BK WH V RD W Compressor (A) 2 1 4 CN_FAN1 U 3 6 5 A1 A2 CN_FAN2 RD WH BK 1 2 3 4 5 6 7 8 BL BL BK Capacitor TB1 BL BK Capacitor OR BL BK BR YL OR BL BK BR YL Outdoor Motor 1 OR BL BK BR YL OR BL BK BR YL Outdoor Motor 2 BL BK BK Magnetic Contactor CN_4,S RD MAIN PCB BK WH YL BL RD SV Solenoid Valve 2 SV Solenoid Valve 1 BK TB2 BK BL BK BL BK BK Crankcase Heater BK WH V RD W Compressor (B) 2 1 4 3 6 5 A1 A2 BK 4WV CN_PRESS U WH CN_COM CN_TH1 Condenser Thermistor RD BK WH CN_POWER Air Thermistor CN_TH2 Compressor Discharge Pipe Thermistor 1 4-Way Valve BL High Pressure Switch BL CN_TH3 Compressor Suction Pipe Thermistor Compressor Discharge Pipe Thermistor 2 GN/YL NOTE R S T N R S T N C BK : BLACK WH : WHITE RD : RED BL : BLUE BR : BROWN YL : YELLOW GN/YL : GREEN/YELLOW Power Supply 3 380~415V 50Hz To Indoor Unit -6- 3854A20684A YELLOW WHITE COMPRESSOR FIELD WIRING Troubleshooting Guide 1-1. General Information DC Link Volt. DC Link Volt Detector IPM EEPROM On_board Rewrite U,V,W Output Communication Parts Hall Sensor Input Voltage Input (R,S,T,N) Current Detector PWM ENABLE -7- SMPS Magnet On/Off Output Error Indicator Communication LED Troubleshooting Guide IPM ( Motor Drive IC) Hall sensor Input Input Voltage Detection SMPS AC->DC converter DC Link Detection Input Current Detection 3•’ Input EMC (Noise Filter) -8- Troubleshooting Guide 1. Error indicator • The function is to self-diagnosis air conditioner and express the troubles if there is any trouble. • Error mark is displayed on wired-remote controller and LED of outdoor unit control board. • If more than two troubles occur simultaneously, lower number of error code is first displayed. • After error occurs, if error is released, error LED is also released simultaneously. ❈ Indoor Error Contents Error Code Case of error Indoor Status 1 Air sensor (open/short) Open / Short Off 2 Inlet pipe sensor Open / Short Off 3 Communication(Indoor ↔ Wired R/Control) Communication Poorly Off 4 Drain pump/ Float switch Float switch Open Off 5 Communication(Indoor ↔ Outdoor) Communication Poorly Off 6 Outlet pipe sensor Open / Short Off 7 Different mode operation Different mode operation Off 9 EEPROM check sum Check sum mismatching Off 10 BLDC motor fan lock Motor not operation Off 15 Communication(indoor ↔ Fan) Communication Poorly Off ❈ Outdoor Error Contents Error Code Case of error Indoor Status 24 High Pressure Switch operation High P/S operates 5times for1hour Off 33 D-Pipe Temp. High D-Pipe Temp ≥120°C Off 44 Air Sensor(open/short) Open/Short Off 45 Outlet Pipe Sensor(open/short) Open/Short Off 47 D-Pipe Sensor(open/short) Open/Short Off 48 S-Pipe Sensor(open/short) Open/Short Off 51 Excess Capacity Indoor load excesses 120K Off 54 Phase error Continually 5times error Off -9- Troubleshooting Guide 2. Error indicator(Fan Board) When CH10 or CH15 error occurs, check error indication LED on fan borad. ❈ Fan board Error Ex) Error 21 (IPM fault) 2 Times 2 Times 2 Times LED01G (RED) 1 Sec. 1 Sec. 1 Time 1 Sec. 1 Time 1 Time LED02G (GREEN) 2 Sec. 2 Sec. Contents Error Code LED01G (Red) LED02G (Green) Case of error Fan malfunction, Locking Outdoor Status 10 Fan Lock 1time 21 IPM Fault (Over current) 2time 1time Fan malfunction, Over Current Off 22 CT 2(Max. Current) 2time 2time Current is 6AÆ Off 23 DC Link Low Volt. 2time 3time DC Link volt. Is 280V Off 40 CT Circuit 4time CT Circuit malfunction (20AÆ ) Off 52 Communication Error 5time Communication Poorly Off 60 EEPROM Check Sum Error 6time Check sum mismatching Off 2time - 10 - Status Troubleshooting Guide 3. Control Parts 1) Troubleshooting CH10 • When CH10 error occurs , check error indication LED on FAN BOARD. Fan board Error LED 10 Title BLDC Fan Lock Cause of error • Mechanical Locking • Miss connection 21 IPM Fault (Over current) • Mechanical Locking • Miss connection • Instant over current • Over Rated current • Poor insulation of IPM 22 CT 2 (Max.Current) • Over current (6A°Ë) 23 DC Link Low Volt • DC link volt. is 280Vdc°È. 40 CT Circuit OPEN/SHORT 60 EEPROM Check Sum Error Check point • The abnormal connection of Hall sensor • The abnormal connection of U,V,W • Mechanical Locking of Fan • Miss connection - The abnormal connection of Hall sensor - The abnormal connection of U,V,W • Instant Overcurrent. - RMS current 20AÆ - Peak current 24AÆ • Poor insulation of Fan • Overload - Mechanical Locking of Fan • Check the overload condition - Mechanical Locking of Fan • Check the drop of power source • Check the power source. • Check the components. • Faulty sensor ( CT Open/short ) • Malfunction of External power • Malfunction of current detection circuit. (Open / Short) • The voltage of “C01N” Is 4.0Vdc (20A)Æ . • Check the drop of power source . • Check sum error • Check the connection port. • Check the poor soldering. 2) Troubleshooting CH15 Fan board Error LED 52 Title Communication Error Cause of error Check point • Connector connection error • Connection of wire • Noise interference • Faulty PCB • Connection wire break - 11 - Troubleshooting Guide In general, possible trouble is classified in two causes. The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application. Unit runs but ineffective cooling Ineffective Cooling or Heating Check of cold (warm) air circulation for smooth flow. Check of outdoor coil (heat exchanger) & the fan operation. Dirty indoor coil (heat exchanger.) Check gas leakage. Check heat load increase in cooling operation. Unexpected residue Added electrical utencil Malfunction of fan. Repair gas leak. Clogging of air filter. Replacement of unit if the unit is beyond repair. Obstruction at air outlet. Check of inside gas pressure. Adjust refrigerant charge. Countermeasure against above trouble. Malfunction of compressor. Check clogging in refrigeration circuit. Repair clogging in refrigeration circuit. Satisfactory operation with temperature difference of inlet & outlet air ; COOLING : 7~10°C HEATING : 15~17°C - 12 - Replacement of compressor Troubleshooting Guide Fails to Start Check power source. Check of circuit breaker and fuse. Check control switch setting. Check control switch. Compressor only fails to start. Fan only fails to start. Electric heater is not energized Improper wiring. Drop of power voltage. Loose terminal connection. Improper wiring Defect of fan motor capacitor. Irregular motor resistance (Ω) Irregular motor insulation (Ω) Replacement of fan motor. Improper electric heater Irregular motor resistance ( Ω ) Regular but fails to start. Replacement of electric heater. Irregular motor insulation ( Ω ) Replacement of compressor. Replacement of compressor - 13 - Troubleshooting Guide VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 380 - 415 V 342 V 456 V 1. No cooling and heating operation performed 1) Both the blower and the compressor do not work WHAT TROUBLED Other parts except the unit COMPLAINTS HOW TO CHECK REMEDY • Electric supply interrupted • Defective power wiring • Cut off power fuse Measure power sypply with a tester in case that the same power source is supplied to other equipment except the unit, what and where troubled can be discovered by checking the operation of other equipment. Too low voltage Measure it with a tester. Check the power source. Use a thick cable if necessary. Magnetic switch for compressor & fan motor Control point is on condition of "OFF" due to trouble. Make short-circuit, then measure it with tester. Replace it if necessary. Operating switch Troubled or defective contactor Check it with the eyes or tester. Repair or replace it. • Repair a switch box and relative instrument. • Replacement of fuse • Request a power supplier to repair. 2) Only Indoor blowers do not work WHAT TROUBLED Motor Reactor Electric wiring COMPLAINTS HOW TO CHECK REMEDY • Over heated • Wiring short Check it with tester Repair or replace it. Defected Check it with a tester. Replace it. • Cut- OFF of wiring • Short circuited on operation Check it with a tester. Rewiring or Repair. - 14 - Troubleshooting Guide 3) Only outdoor fan does not work WHAT TROUBLED COMPLAINTS HOW TO CHECK REMEDY Motor • Over-heated • Wire short Check how it is insulated. Repair or replace it. Electric Wiring Cut off of wiring Check it with a tester. Rewiring or repair. Short circuited on operation 4) Only compressor does not work WHAT TROUBLED COMPLAINTS HOW TO CHECK REMEDY Magnetic switch for compressor motor Defective contact, magnetic coil troubled. Check it with the eyes on with a tester. Repair or replace it. Compressor motor Troubled over-heated (layer short) Check how it is insulated. Replace or repair the compressor. High pressure switch (Option part) Troubled or defective contact or operating Check it with a tester. Replace it if necessary. Electric circuit Defective connection or disconnection of the circuit for compressor. Check it with a tester. Rewiring or push reset button. - 15 - Troubleshooting Guide 2. The Units discontinue after the operation started WHAT TROUBLED COMPLAINTS HOW TO CHECK REMEDY Outdoor coil Coil is dirty *1 Checking Wash it by means of something like chemical washing. In-condensable gas blended. Air intruded into the refrigerant pipe line *1 In the event that difference between the saturating temperature corresponding to high pressure and the temperature of air discharged from the outdoor coil is more than 15°C, incondensable gas may be blended. Extract air by vacuum pump, then replenish (charge) the refrigerant. High pressure switch (Option part) Improper adjustment Check it with a pressure gauge. Read just it to normal operating pressure. (Note) Don't alternate the specified adjusting pressure. If the adjusted pressure exceed the specified range, it will cause a great accident. Outdoor Fan Reverse rotation of fan Obstacle Confirm the wind blowing out upward. Air short circuit *1 Check it with eyes. If reversed, connect interchanged wires to each terminal. Power wirings. Note: Use an appropriate measuring instrument for readjustment. *1: High-pressure switch moves. - 16 - Troubleshooting Guide 3. The unit is working, but not cooling and heating sufficiently (Both blower and compressor are working) WHAT TROUBLED COMPLAINTS HOW TO CHECK REMEDY Load Much Cooling or Heating load Heat load increased. Window or door has many cracks or gaps. Do necessary disposal respectively. Air flow Obstacle disturbs Intake of uniform airflow. Checking Correct it. Short air volume Reverse rotation of blower. Checking Correct it. Refrigerant Shortage in the charged refrigerant. Coil inlet pipe is frosted Recharge it. (Repair the leakage spot). Air passage Improper or foreign bodies Checking Correct or clear the foreign bodies. Air filter Clogged with dust Checking Cleaning 4. All the functions are performed as specified, but very noisy and vibrant WHAT TROUBLED Compressor Blower COMPLAINTS HOW TO CHECK REMEDY Liquid refrigerant flooding back from the evaporator. • Check for refrigerant over-charge. • Check to see if the intake air temperature is extremely cold. • Check for insufficient air flow quantity. Faulty Discharge valve and suction valve. • Checking • Replace the compressor Fan broken. Checking Repair or replace it. Clear the foreign bodies. Foreign matters intruded. Screws Looseness or fail-off of screws Checking Correct Electric troubles (Magnetic contactor) Defective contact. Defective contact point. Rusting and foreign matters in the iron core contact face. Defective contact of the operating switch. Checking Repair and clean or replace it. Others Improper installation Checking Correct it. - 17 - Electronic parts Troubleshooting Guide Possible trouble 1 Is the input voltage of transformer AC220V? : The unit does not operate. NO 1. Check the Fuse. 2. Check the wiring of AC220V. NO 1. Exchange the transformer. 2. Check the connector of transformer. YES Is the output voltage of transformer AC24V & AC13V? YES Is the output voltage of IC02D(7805) on the main PCB DC5V? NO 1. Exchange IC02D(7805) on the main PCB. 2. Check the D01D~D05D, R05C on the main PCB. YES Is the output voltage of IC01D(7812 ) on the main PCB DC12V? NO 1. Exchange IC01D(7812) on the main PCB. 2. Check the D01D~D05D, R05C on the main PCB. YES Is the output voltage of IC01A(7036) on the main PCB DC5V? NO 1. Exchange IC01A(7036) on the main PCB. YES OSC vibration? NO 1. Exchange OSC. 2. Check the pattern around OSC on the main PCB. YES 1. Exchange main PCB ASS'Y Possible trouble 2 Is the power ON? : The remote-controller does not operate. NO 1. Exchange or exchange FUSE. 2. Check the input voltage of Main PCB ASS'Y. YES Is the input voltage of remote-controller DC12V? NO 1. Check or exchange the IC01D on the Main PCB. 2. Check or exchange the Connector (RED, BROWN) of the remote controller. YES 1. Exchange remote-controller 2. Check or exchange the Main PCB ASS'Y. - 18 - Electronic parts Troubleshooting Guide Possible trouble 3 Is the connection between MAIN PCB and remote-controller correct? : Key input of remote-controller does not respond. 1. Check or repair Connector wiring. 2. Exchange the Connector. NO YES Is any key on the remote-controller keeping pressed? 1. Replace the pressed key. 2. Exchange the Knob or Key. YES NO Is there Check(F**) on the remote controller LCD? YES 1. Remove cause of Check. 2. Reenergize the power supply. NO Is the input power voltage of remote-controller DC12V? NO 1. Check or exchange IC01D (7812) on the MAIN PCB. YES Is there OSC vibration on the remote-controller PCB? NO 1. Exchange OSC 2. Check the pattern around OSC on the remote-controller PCB. YES Do Keys have troubles? YES 1. Check Keys. 2. Repair or exchange Key. NO Exchange remote-controller. Possible trouble 4 Are there trouble in LCD parts? : LCD display on the remote-controller shows some trouble. YES 1. Check crack, damage of LCD. 2. Check LCD pattern. NO Is there trouble in the remote-controller PCB ASS'Y? YES 1. Check or repair all IC with dust or moisture on the PCB. 2. Exchange remote-controller PCB. NO Exchange remote-controller. - 19 - Electronic parts Troubleshooting Guide Possible trouble 5 Is the unit operating? : No cooling operation performed. NO 1. Press power ON/OFF button. YES Is the cooling mode? NO 1. Press cooling operation key. 2. After reenergizing power supply, press power "ON/OFF" button. NO 1. Set flowing. 'Set Temp. < Room Temp.' YES Set Temp. < Room Temp.? YES Is the output voltage of Micom's 4PIN on the MAIN PCB DC0V? NO 1. Check or exchange IC02D. 2. Check 3-minutes time delay. YES Is the voltage between 1PIN of CN-COMP and NEUTRAL 220V? NO 1. Check or exchange RY4. YES Is the magnetic contactor for compressor OK? NO 1. Check the wiring of Magnetic contactor. 2. Exchange Magnetic contactor. YES 1. Check Compressor and Capacitor for Compressor. NOTE: 3ø model has not capacitor for compressor. - 20 - Electronic parts Troubleshooting Guide Possible trouble 6 Is the heater operation? : No heater operation performed. NO 1. Select heater operation mode. YES Is the heater LCD "ON"? NO 1. Reconnetting power supply. press Heater Key. NO 1. Set following. 'Set temp. > Room temp.' NO 1. Check or exchange IC01D, IC02D on the MAIN PCB. YES Set temp. > Room temp.? YES Is the output voltage of Micom's 13PIN on the MAIN PCB 5V? YES Is the voltage between 1PIN of CN6 and NEUTRAL 220V? NO 1. Check or exchange RY13. YES Is the magnetic contactor for heater OK? NO 1. Check the wiring of Magnetic contactor. 2. Exchange Magnetic contactor. YES Check or exchange E/Heater. - 21 - Electronic parts Troubleshooting Guide Possible trouble 7 Is the indoor fan operation? : No humidifier operation performed. 1. Press cooling or fan operation or heater operation key. NO YES Is the HUMID LCD "ON"? NO 1. Press humidifier Key. YES Is the output voltage of Micom's 3PIN on the MAIN PCB 5V? 1. Check or exchange IC02D on the MAIN PCB. NO YES Is the voltage between 1PIN of CN5 and NEUTRAL 220V? NO 1. Check or exchange RY3. YES Is the magnetic contactor for humidifier OK? NO 1. Check the wiring or Magnetic contactor. 2. Exchange Magnetic contactor. YES Check the humidifier. - 22 - Electronic parts Troubleshooting Guide Possible trouble 8 Is the unit operating? : Indoor motor does not operate. NO 1. Press power ON/OFF button. 2. Reconnect the power supply. YES Is the output voltage of Micom's 10PIN on the MAIN PCB 5V? NO 1. Check or exchange IC01D, IC02D on the main PCB. YES Is the voltage between 1PIN of CN8 and NEUTRAL 220V? NO 1. Check or exchange RY10. YES Is the "Power relay" for indoor motor OK? NO 1. Check the wiring of "Power relay". 2. Exchange "Power relay". YES Check the indoor motor. Possible trouble 9 Is it cooling operation? : Outdoor motor does not operate. NO 1. Press power "ON/OFF" button. 2. Select cooling operation. YES Is the compressor operating? NO 1. Set following. Set temp. < Room temp. 2. Wait, if the unit has operating with 3-minute time delay. YES 1. Check wiring for outdoor motor and magnetic contactor. 2. Check outdoor motor & capacitor. - 23 - Features of Controller 1. Circuit Diagram of Indoor PCB - 24 - 2. Circuit Diagram of BLDC Driver - 25 - 3. Circuit Diagram of Outdoor PCB - 26 - 4. Error Mode & Corrective Method Error mode Cause of error CH01 OPEN/SHORT of Room Temp .sensor CH02 OPEN/SHORT of Indoor Pipe sensor CH03 Communication Error between indoor PCB and Remote controller CH05 Communication Error between indoor PCB & outdoor PCB CH24 High Pressure Switch Trip Sensing condition of error CH33 CH44 CH45 CH47 CH48 CH54 - 27 - Method of SVC Remark Exploded View and Replacement Parts List 1. Indoor Unit • Exploded View (AB-H1208VA0) 342800 349600 336610 344170-2 344170-1 359012 354210 349610 152302 268714-1 268714-2 WOFZZ 658740 330870 566001-1 W6200 249951 263230-4 267110 263230-5 263230-6 - 28 - Exploded View and Replacement Parts List • Replacement Parts List AB-H1208VA0 LOCATION No. PART No. DESCRIPTION AB-H1208VA0 336610 344170-1 344170-2 349610 359012 349600 342800 330870 354210 152302 267110 249951 268714-1 268714-2 658740 566001-1 WOFZZ W6200 263230-4 263230-5 HOUSING ASSEMBLY ROTOR ASSEMBLY STATOR ASSEMBLY MOUNT ASSEMBLY, MOTOR FAN ASSEMBLY, BLOWER BRACKET ASSEMBLY BEARING DRAIN PAN ASSEMBLY EVAPORATOR ASSEMBLY FILTER(MECH) REMOTE CONTROLLER ASSEMBLY CONTROL BOX ASSEMBLY, INDOOR PCB ASSEMBLY PCB ASSEMBLY REACTOR MAGNETIC CONTACTOR FUSE FILTER(CIRC),EMC THERMISTOR ASSEMBLY THERMISTOR ASSEMBLY 3661A10031A 4413A20001A 4417A20001B 4961A10014A 5835A20003G 4811A10003B 4A00131C 3087A20032A 5421A20217A 5230A30017B 6711A20127B 4995A20526A 6871A00012A 6871A10222A 5874A90003H 6600B000039 0FZZA90001M 6200J000125 6323A30004L 6323AQ3226Y 263230-6 THERMISTOR ASSEMBLY 6323A30002C - 29 - REMARK Main PCB BLDC Motor 15A , 600V RETURN AIR SENSOR PIPE(EVA.OUT) TEMP. SENSOR PIPE(EVA. IN) TEMP. SENSOR Exploded View and Replacement Parts List 2. Outdoor Unit • Exploded View (AB-H1208VA0) 435312 559010 549610 546810 554032-2 554032-4 554032-1 554032-3 649950 566001 W0CZZ 668711 W6920 552201-1 548490 561410 552201-2 552116 566000 552204 561411-1 554160-2 561411-2 561411-3 552203-2 552203-1 263230-2 554160-1 263230-1 552200 263230-3 - 30 - Exploded View and Replacement Parts List • Replacement Parts List AB-H1208VA0 LOCATION No. 559010 435312 546810 549610 649950 668711 566001-2 W6920 W0CZZ 554032-1 554032-2 554032-3 554032-4 554032-1 554032-2 554032-3 554032-4 554160-1 554160-2 548490 552203-1 552203-2 552116 552200 552201-1 552201-2 552204 561410 561411-1 561411-2 561411-3 566000 263230-1 263230-2 263230-3 PART No. DESCRIPTION AB-H1208VA0 FAN ASSEMBLY, PROPELLER GRILLE ASSEMBLY, DISCHARGE MOTOR ASSEMBLY, OUTDOOR MOUNT ASSEMBLY, MOTOR CONTROL BOX ASSEMBLY PCB ASSEMBLY SWITCH, MAGNET RELAY CAPACITOR CONDENSER ASSEMBLY CONDENSER ASSEMBLY CONDENSER ASSEMBLY CONDENSER ASSEMBLY CONDENSER ASSEMBLY CONDENSER ASSEMBLY CONDENSER ASSEMBLY CONDENSER ASSEMBLY COMPRESSOR COMPRESSOR ACCUMULATOR VALVE, SERVICE VALVE, SERVICE TUBE ASSEMBLY, REVERSING VALVE, EXPANSION BODY VALVE, CHECK VALVE, CHECK VALVE,SOLENOID COIL ASSEMBLY,REVERSING VALVE COIL ASSEMBLY,EXPANSION COIL ASSEMBLY, SOLENOID COIL ASSEMBLY, SOLENOID SWITCH, PRESSURE THERMISTOR THERMISTOR THERMISTOR 5901A10029A 3531A20211F 4681A10014H 4960A10022A 4995A10163A 6871A20583W 6600B000041 3A00261C 3A00988G 5403A20160A 5403A20160B 5403A20159A 6711A20127B 5403A20160G 5403A20160H 5403A20159G 5403A20159H 2520UBBY2BA 2520UBDY2AB 4849A10038A MJX30447401 5220A20035A 5211A12308C 5220A90013A 3A01020H 3A01020L 5220A90002H 6141A20010R 6141A20011W 6141A20031L 6141A20031M 3A02524L 6323A20020P 6323A20020Q 6323A20020R - 31 - REMARK 10 µF, 450VAC PCM PCM PCM PCM GOLD GOLD GOLD GOLD AR081YAB AR073YAB Ø 28 Ø 15.88 HIGH PRESSURE CONDENSER, AMBIENT TEMP. COMP-A DISCHARGE,SUCTION COMP-B DISCHARGE P/No.: 3828A20845A June, 2006 Printed in Korea