Download LG TS-C122YDA0 User's Manual
Transcript
http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : TS-C122YDA0 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 1. Specification Models TS-C122YDA0 Cooling Capacity (Min∼Rating∼Max) kW 3.52 Btu/h 12,000 Heating Capacity (Min∼Rating∼Max) kW - Btu/h - Power Input Cooling/Heating W 1 150/- Running Current Cooling/Heating A 5.4/- Starting Current Cooling/Heating A 26/- W /W 3.05 Btu/h.W 10.43 EER COP W /W Power Supply Φ Power Factor Air Flow Rate / V / Hz Indoor,Max % ㎥/min(cfm) 99.3 8.83 Outdoor,Max ㎥/min(cfm) 18 1.46 Moisture Removal Sound Level l/h Indoor,H/M/L dB(A)+1 Outdoor,Max dB(A)+1 g(oz) Refrigerant & Charge(at 7.5m) g/m(oz/ft) Additional Refrigerant Charge Type Oil Type cc O.L.P Name Cross Flow Fan Motor Output W Type Circuit Breaker 400 cc - Type 46 Propeller AC Induction Motor Type * 20(0.22) SUNISO 4GSI Oil Charge Fan(outdoor) R22, 650(22.92) PH180X1C-3FTU2 PSC Motor Type Fan(Indoor) 41 51 Rotary(Non Tropical) Model Compressor 1/220/60 Motor Output Power Supply Cable W 89 A No.*㎟ 3*1.0 No.*㎟+No.*㎟ Power and Transmission Cable 29 6.35(1/4) Piping Connections Liquid Side mm(in) Gas Side mm(in) 12.7(1/2) Drain Hose O.D , I.D mm(in) Indoor(W *H*D) Dimension Operation Range Network Functions inch 30.31*21.26*9.65 kg(lbs) 9(19.8) Outdoor kg(lbs) o o C( F) 35(77.1) 21 ∼ 43 Cooling(Outdoor) o Heating(Outdoor) Max. Elevation Difference Functions 35.5*12.68*7.87 Indoor Max. Piping Length Tool Code(Chassis) inch 770*540*2450 Outdoor(W *H*D) Net W eight mm 21.5,16(0.85,0.63) 902*322*200 o C( F) 13 m(ft) 7.5 SY + UL Indoor + Outdoor Temperature Control Plasma Filter Prefilter(washable/anti-fungus) Auto Clean CHAOS W ind(Auto W ind) Steps, Fan/Cool/Heat Airflow Direction Control(up&down) Airflow Direction Control(left&right) Remocon Type Cooling Setting Temperature Range Heating Auto Operation (Micom Control) Auto Changeover (Micom Control) Self Diagnosis Timer Sleep Operation Soft Dry Operation Restart Delay(minute) Deice Control(Defrost) Hot Start Jet Cool Low Ambient Operation Special Function Dry Contact Network Solution(LGAP) PI485 - m(ft) Thermistor ○ ○ ○ 3/4/Auto Manual W ireless Simple 18 ∼ 30 ○ 7h, On/Off ○ ○ 3 ○ ○ - Note: Note: O : Applied, - : No relation * For circuit breaker rating, please conform to local standards wherever necessary. 2 Room Air Conditioner Some of functions are slightly different depending upon models. The specification may be subject to change without prior notice for purpose of improvement. 2. Piping Diagrams Indoor Unit Outdoor Unit Liquid Side Capillary Tube 2-Way Valve Th2 Th1 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Compressor Gas Side 3-Way Valve Accumulator High Pressure S/W Cooling LOC. Description Th1 Thermistor for indoor air temperature Th2 Thermistor for evaporating temperature PCB Connector CN-TH1 Service Manual 3 3. Wiring Diagrams BL GN/YL BR Indoor Unit GN/YL BL BR 1(L)2(N) 3 3854A23009 FUSE CN-N2 CN-N1 CN-MOTOR 4 Room Air Conditioner RY-COMP3 RY-COMP4 CN-U/D CN-HVB CN-DISP2 Outdoor Unit BLUE RED BLUE S R CAPACITOR H C F RED BLUE OVERLOAD PROTECT C YELLOW/GREEN BLUE BROWN YELLOW FAN BLUE BROWN TERMINAL BLOCK 1(L) 2(N) THE UNIT INDOOR OUTDOOR DIAGRAM WIRING EBY36312302 Capacitor Terminal Block Service Manual 5 Exploded View Exploded View 1. Indoor Unit 135316 135301 13 55 11 135314 152302 W3300 131410 359011 342800 354210 435301 147582-1 147582-2 147581-1 268711 346810 35211B 135516 354212 263230 352150 135311 249941 146811 264110 WOFZZ W6640 267110 249951 6 Room Air Conditioner 268711 W0CZZ Outdoor Unit Models: TS-C122YDA0 237202 437211 435301 437212 554032 435511 349600 559010 W0CZZ 546810 552111 567502 554160 447910 552117 W6640 430400 148000 W6631 649950 550140 552203-1 552203-2 430410 Service Manual 7 P/NO : MFL37322726 DECEMBER, 2008