Download MAINTENANCE INTERVALS - Safety

Transcript
132
Maintenance Section
Window Washer Reservoir - Fill
2. Install ferrule retainer (1).
3. Reel in the cable.
i01279658
Window Washer Reservoir - Fill
SMCS Code: 7306-544
NOTICE
When operating in freezing temperatures, use
Caterpillar or any commercially available nonfreezing
window washer solvent.
g00550538
Illustration 261
1. Install the ferrule end into the socket .
2. Reel in the cable.
57
The cable is attached to the drum on the winch with
a standard cable ferrule. The ferrule is placed into
a socket on the drum and the ferrule is secured
with a bolt-on retainer.
Ferrules are made in several diameters and lengths.
Use the following table to order the cable.
Illustration 263
g00103795
Table 22
Wire Cable
Wire Rope
Diameter
Recommended
Ferrule
Holding Capacity
25 mm (1 inch)
L-8
73 m (239 ft)
29 mm
(1.13 inch)
J-9
58 m (190 ft)
Window Washer – The washer fluid
bottle is on the left side of the operator’s
compartment. Open the access cover.
Remove the fluid bottle cap in order to fill the
washer fluid bottle.
i01279804
1. Put the cable in a straight line behind the tractor.
Window Wipers Inspect/Replace
SMCS Code: 7305-040; 7305-510
Illustration 262
g00392987
1. Remove ferrule retainer (1). Install the ferrule end
into socket (2).
Illustration 264
g00103881