FDNY March 15, 1997 DCN: 4.06.08 FIREFIGHTING PROCEDURES LADDER COMPANY OPERATIONS: AERIAL LADDERS 3.2.4 Proper placement of the aerial ladder may be affected by the above conditions and also by the wind, or by heat or flame issuing from below the rescue effort. This could cause the laddermen to risk positioning the ladder in a manner that would only be used in a serious fire situation. (Fig. 2C) Good judgment by the officers and firefighter in ladder placement will require them to be cognizant of these conditions. Figure 2C Change in apparatus placement due to wind condition 3.3 People on the fire escape above the fire. (Figs. 3A and 3B) 3.3.1 Place the ladder alongside the fire escape and against the building (2" out) with the tip about one to three feet above the balcony railing. This affords easier access to the ladder. Note: Remember the loss in height engendered by retracting the ladder to apply ladder locks. 3.3.2 Whenever possible, place the ladder on the least exposed side of a building. (Figs. 3A and 3B) If interior conditions permit, take the people into the least exposed apartment or other area and use the safest means of egress for their removal. 5