Download TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR
Transcript
9-3. Some part of air conditioner does not operate. 9-3-1. Only indoor fan does not run. • Check fan rotation. Turn fan gently once or twice by hand. • Check fan casing foreign matter on inside. Fan cannot be turned. Remove foreign matter or repair. Fan motor burnout or foreign matter in bearings. • Measure resistance of indoor fan motor winding. Repair or replace. • When fan speed is changed, does applied voltage between lead wires BRN and WHT change as well ? OK NO • Check fan motor capacitor. • PCB Ass'y is defective. 9-3-2. Only flap motor does not run. • Measure resistance of flap motor winding. 9-3-3. Function of outdoor fan speed control does not work properly. (For C121 models) • Check thermostat in outdoor unit. (23S) Refer to "8-8 Outdoor Fan Speed Control ". 42