Code
C6020
C6050
C6120
C6150
Contents
Abnormally high fuser thermistor
center temperature
Fuser thermistor 2 is detected 230°C/
446°F or more for 40 ms.
Abnormally low fuser thermistor center temperature
Fuser thermistor 1 is detected 100°C/
212°F less then 1 s continuously during
copying.
Abnormally high fuser thermistor
edge temperature
Fuser thermistor 1 is detected 240°C/
464°F or more for 40 ms.
Abnormally low fuser thermistor edge
temperature
Fuser thermistor 1 is detected 80°C/
176°F less than 1 s continuously during
copying.
Causes
Check procedures/corrective measures
Installation defectiveness on fuser
thermistor 2.
Check the mounting state of the fuser thermistor 2. If any problem is found, repair it.
Defective fuser
thermistor 2.
Replace the fuser thermistor 2.
Defective engine
PWB.
Replace the engine PWB and check for correct operation.
Defective fuser
heater 1 or 2.
Replace the fuser heater 1 or 2.
Installation defectiveness on fuser
thermistor 2.
Check the mounting state of the fuser thermistor 2. If any problem is found, repair it.
Defective PWB.
Replace the power source PWB or engine
PWB and check for correct operation.
Installation defectiveness on fuser
thermistor 1.
Check the mounting state of the fuser thermistor 1. If any problem is found, repair it.
Defective fuser
thermistor 1.
Replace the fuser thermistor 1.
Defective engine
PWB.
Replace the engine PWB and check for correct operation.
Defective fuser
heater 1 or 2.
Replace the fuser heater 1 or 2.
Installation defectiveness on fuser
thermistor 1.
Check the mounting state of the fuser thermistor 1. If any problem is found, repair it.
Defective PWB.
Replace the power source PWB or engine
PWB and check for correct operation.
C6400
Zero-cross signal error
While fuser heater ON/OFF control is
performed, the zero-cross signal is not
input within 3 s.
Defective PWB.
Replace the power source PWB or engine
PWB and check for correct operation.
C6420
Fuser unit fuse cut problem
The fuse cannot be cut, When replacing
the fuser unit, the fuse cannot be cut in
3 s after the fuse cut signal is turned on.
Poor contact in the
connector terminals.
Check the connection of connector YC1 on
the engine PWB and the continuity across
the connector terminals. Repair or replace if
necessary.
Fuser unit connector inserted incorrectly.
Reinsert the fuser unit connector if necessary.
1-4-27