* SECOP (Danfoss) compressor: auxiliary code B1 and later
240AWNE 240AWNE-23 240AWNE-21
No
Item
(50Hz)
(50Hz)
(50Hz)
1 Defrost completion temp
5
2 Integrated constant 1 (temp)
-17.5
3 Integrated constant 2 (time)
11
4 Ambient temp correction
30
Basic
operating temp for integrated
value
5 Ambient temp correction rate
95
for integrated value
6 Freeze backup timer
45
10 Defrosting water supply time,
95
water temp less than 13°C
11 Defrosting water supply time,
30
water temp 13°C or more
12 Icemaking water supply time,
30
partial drain flush
* Icemaking water supply
60
time, full drain flush
Water supply
13 Water temp measurement
10
correction value
14 * Full / partial drain flush
1
selection
15 Additional icemaking water
22
supply time, partial drain
flush
* Additional icemaking water
44
supply time, full drain flush
21 Double stack bin control
1
Other
22 Refrigeration unit operation
0
in bin control cycle
30 Type
Model
0
Defrost cycle low 34 Operating temp
45
temp control
36 Water regulator error
0
Water regulator
detecting temp
37 Compressor output selection
Compressor
1
50 Pump off time
0
Slush ice
51 Water supply time
0
60 Operating condition
10
Hard water
61 Water supply time
0
70 Operating temp
50
Ice left in water
71 Hot gas valve on time
2
pan
72 Hot gas valve off time
28
73 Hot gas valve off time
Ice bridge
0
Low temp in
74 Operating temp
0
defrost cycle
* When No. 14 is set to “0” (full drain flush), change Nos. 12 and 15 also to full drain flush
settings.
63