Download cooling performance data
Transcript
TECHNICAL MANU AL MANUAL *PG15 Package Gas Units • Refer to Service Manual RS6300007 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3. • Select Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency** ® C US **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits. This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person. Copyright © 2007 - 2009-2010 Goodman Manufacturing Company, L.P. RT6313001r11 April 2010 PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. G/A P G BRAND: ® G: Goodman Brand or Distinctions ® A: Amana Brand 15 24 PRODUCT SERIES: SEER Rating * * MAJOR REVISION: HEATING INPUT 070: 69,000 BTUH 090: 92,000 BTUH 115: 115,000 BTUH 140: 138,000 BTUH VOLTAGE: 1: 208-230V/1ph/60Hz 3: 208-230v/3ph/60Hz 4: 460v/3ph/60Hz NOMINAL CAPACITY: 24: 24,000 BTUH 30: 30,000 BTUH 36: 36,000 BTUH 37: 36,000 BTUH 42: 42,000 BTUH 48: 48,000 BTUH 49: 48,000 BTUH 60: 60,000 BTUH HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Goodman will not be responsible for any injury or property damage arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment. 2 1 REFRIGERANT: 4: R-410A PRODUCT FAMILY: G: Gas/Electric WARNING 4 MINOR REVISION: PRODUCT TYPE: Single Package Cooling/Heating WARNING 070 Installation and repair of this unit should be performed ONLY by individuals meeting (at a minimum) the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death. WARNING PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. GPG152407041A* GPG153009041A* GPG153609041A* GPG153709041A* GPG154209041A* GPG154811541A* GPG154911541A* GPG156014041A* APG152407041A* APG153009041A* APG153609041A* APG153709041A* APG154209041A* APG154811541A* APG154911541A* APG156014041A* * Indicates minor revision & is not used for order entry or inventory management The models listed below qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency** APG152407041A* APG153007041A* APG153709041A* APG154209041A* APG154911541A* GPG152407041A* GPG153007041A* GPG153709041A* GPG154209041A* GPG154911541A* **Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits. WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. Do not connect or use any device that is not design certified by Goodman for use with this unit. Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices. WARNING To prevent the risk of property damage, personal injury, or death, do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance. WARNING 3 PRODUCT DESIGN *PG15 Package Gas Units are designed for outdoor installations only in either residential or light commercial applications and are available in 2, 2-1/2, 3, 3-1/2, 4 & 5 ton sizes. They are designed for 208/230 volt single phase applications. The connecting ductwork (Supply and Return) can be connected for either horizontal or vertical airflow. In the vertical application, a matching Roof Curb is recommended. A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible location within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Section. Under no circumstances should the unit be operated without return air filters. A 3/4" pipe is provided for removal of condensate water from the indoor coil. (Do not reduce the drain line size). Refrigerant flow control is achieved by use of a TXV or orifice. - These Scroll compressors use "POE" orpolyolester oil which is NOT compatible with mineral oilbased lubricants like 3GS. "POE" oil must be used if additional oil is required. - Compliant scroll compressors perform “quiet” shutdowns that allow the compressor to restart immediately without the need for a time delay. This compressor will restart even if the system has not equalized. - Operating pressures and amp draws may differ from standard reciprocating compressors. This information may be found in the “Cooling Performance Data” section. Some other models of the *PG15 series package units use a 2 stage scroll compressor. The basic scroll design has been modified with the addition of an internal unloading mechanism that opens a by-pass port in the first compression pocket, effectively reducing the displacement of the scroll. The opening and closing of the by-pass port is controlled by an internal electrically operated solenoid. *PG15 units use the FasTest Access Fitting System which consists of a saddle that is either soldered to the suction and liquid lines or is fastened with a locking nut to the access fitting box (core) and then screwed into the saddle. NOTE: The core must not be removed from the saddle until the refrigerant charge has been removed. Failure to do so could result in property damage or personal injury. The single phase units use permanent split capacitors (PSC) design compressors. Starting components are therefore not required. A low MFD run capacitor assists the compressor to start and remains in the circuit during operation. The *PG15*****41AA models are equipped with X-13 blower motors. X-13 motors are constant torque motors with very low power consumption and are energized by a 24V signal from the ignition control board. The X-13 features an integrated control module. Air for condensing (cooling cycle) is drawn through the outdoor coil by a propeller fan, and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction (ductwork) shall be applied. Conditioned air is drawn through the filter(s), field installed, across the coil and back into the conditioned space by the indoor blower. The *PG15 series package units use the Compliant Scroll compressor; there are a number of design characteristics which are different from the traditional reciprocating compressor. - Due to their design Scroll compressors are inherently more tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued flood back or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure. 4 The ZPS modulated scroll uses a single step of unloading to go from full capacity to approximately 67% capacity. A single speed, high efficiency motor continues to run while the scroll modulates between the two capacity steps. PRODUCT DESIGN Location and Clearances NOTE: To ensure proper condensate drainage, unit must be installed in a level position. NOTE: To ensure proper condensate drainage, unit must be installed in a level position. In installations where the unit is installed above ground level and not serviceable from the ground (Example: Roof Top installations) the installer must provide service platform for service person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the National Fuel Gas Code ANSIZ223.1. NOTE: Unit can also use roof curb (and platform for leveling, where necessary) to utilize bottom discharge. 48" MIN 12" MIN WARNING 36" MIN (FOR SERVICE) . 3" MIN 12" MIN 36" MIN (FOR SERVICE) Outside Slab Installation NOTE: Roof overhang should be no more than 36" and provisions made to deflect the warm discharge air out from the overhang. Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency. TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING IF A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING. IMPORTANT: If using bottom discharge with roof curb, ductwork should be attached to the curb prior to installing the unit. Refer to Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Rooftop Installation 5 PRODUCT DESIGN High Altitude Derate - U.S. Installations Only IMPORTANT NOTE: The gas/electric units naturally derate with altitude. Do not attempt to increase the firing rate by changing orifices or increasing the manifold pressure. This can cause poor combustion and equipment failure. At all altitudes, the manifold pressure must be within 0.3 inches W.C. of that listed on the nameplate for the fuel used. At all altitudes and with either fuel, the air temperature rise must be within the range listed on the unit nameplate. Refer to the Installation Manual provided with the LP kit for conversion from natural gas to propane gas and for altitude adjustments. When this package unit is installed at high altitude, the appropriate High Altitude orifice kit must be installed. As alti- tude increases, there is a natural reduction in the density of both the gas fuel and combustion air. This kit will provide the proper design certified input rate within the specified altitude range. High altitude kits are not approved for use in Canada. For installations above 2,000 feet, use kit HA-02. The HA-02 kit is used for both Natural and LP gas at high altitudes. Use LPM-06 propane conversion kit for propane conversions at altitudes below 2000 feet. Natural gas installations below 2000 feet do not require a kit. For propane conversions above 2000 feet, high altitude kit HA-02 is required in addtion to LPM-05 propane conversion kit. NATURAL GAS AND LP GAS INSTALLATIONS AT ALTITUDES > 2000 FT INPUT/BURNER 20,000 BTUH NAT/20,OOO BTUH/L.P. HIGH ALTITUDE KIT ELEVATION ABOVE SEA-LEVEL (FEET) 2000 U.S. BURNER ORIFICE CANADA BURNER ORIFICE INPUT/BURNER HA02 45/55 CANADA BURNER ORIFICE INPUT/BURNER CANADA BURNER ORIFICE 6 3000 4000 44/55 44/55 45/56 44/55 48/57 6000 7000 8000 47/56 48/57 48/58 49/58 - - - - - - 4500 47/57 5000 6000 7000 8000 45/56 46/57 47/58 47/58 - - - - 25,000 BTUH NAT/20,OOO BTUH/L.P. HIGH ALTITUDE KIT HA02 - - 5000 ELEVATION ABOVE SEA-LEVEL (FEET) ELEVATION ABOVE SEA-LEVEL (FEET) 2000 U.S. BURNER ORIFICE - 4500 22,500 BTUH NAT/20,OOO BTUH/L.P. HIGH ALTITUDE KIT HA02 4000 45/55 47/55 47/56 2000 U.S. BURNER ORIFICE 3000 3000 4000 43/55 43/55 44/56 43/55 - - 4500 46/57 5000 6000 7000 8000 44/56 44/56 45/57 45/57 - - - - PACKAGE GAS SPECIFICATIONS UNIT DIMENSIONS 47 51 FLUE EXHAUST HOOD 18 7/16 16 FLUE EXHAUST 1 3/8 C A 5 1/2 16 7 15/16 B SUCTION/LIQUID PRESSURE PORTS BEHIND COMPRESSOR ACCESS PANEL 2 3/4 COMBUSTION AIR INTAKE RETURN B HEAT EXCHANGE ACCESS PANEL 4 3/4 GAS SUPPLY ENTRANCE CONDENSATE DRAIN CONNECTION 3/4" NPT FEMALE SUPPLY 3 EVAPORATOR/CONTROL PANEL ACCESS PANEL 16 1/8 19 1/8 OF R TE ITY N V CE RA G 7 5/16 7 7/8 20 24 DIMENSION (INCHES) MEDIUM LARGE A B 32 16 40 18 C 9 1/2 14 POWER WIRE ENTRANCE CONTROL WIRE ENTRANCE 5 1/4 EXHAUST FLUE HOOD BLOWER ACCESS PANEL COMBUSTION AIR INTAKE 11 5 3/4 22 MEDIUM CHASSIS *PG15[24-37] 22 LARGE CHASSIS *PG15[42-60] 11 SUPPLY RETURN 7 PACKAGE GAS SPECIFICATIONS COOLING CAPACITY *PG152407041AA *PG153009041AA *PG153609041AA *PG153709041AA HIGH STAGE 23,200 29,000 35,400 35,000 LOW STAGE N/A N/A 24,400 N/A 15.0 / 12.0 14.5 / 12.0 15.0 / 11.0 14.5 / 12.0 COOLING CAPACITY, BTUH SEER / EER HEATING CAPACITY *PG15[24-37]***41AA BTUH INPUT (US) HIGH FIRE OUTPUT (US) HIGH FIRE (Natural Gas) OUTPUT (US) HIGH FIRE (LP) 69,000 92,000 92,000 92,000 55,000 73,500 73,500 73,500 50,000 69,000 69,000 69,000 52,000 69,000 69,000 69,000 OUPUT (US) LOW FIRE (Natural) 41,500 55,000 55,000 55,000 OUTPUT (US) LOW FIRE (LP) 37,000 50,000 50,000 50,000 80 80 80 80 RATED EXTERNAL STATIC (" w.c.) 0.50 0.50 0.50 0.50 TEMPERATURE RISE (°F) 35-65 45-75 45-75 45-75 PRESSURE SWITCH TRIP POINT (" w.c.) -.33" -.33" -.33" -.33" 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 BTUH INPUT (US) LOW FIRE A.F.U.E. UNIT VOLTAGE (NAMEPLATE) ELECTRICAL UNIT AMPS (TOTAL) 18.7 17.5 22.2 20.1 SPECIFICATION MINIMUM CIRCUIT AMPACITY 22.1 21 26.5 24.2 MAXIMUM OVERCURRENT PROTECTION(3) 30 35 40 40 HEATING NUMBER OF BURNERS 3 4 4 4 SECTION ORIFICE SIZE NATURAL 43 43 43 43 ORIFICE SIZE LP 55 55 55 55 TYPE Scroll Scroll Scroll Scroll RATED LOAD AMPS 13.5 14.1 16.7 16.7 LOCKED ROTOR AMPS 58.3 73 82 79 CONDENSER HORSEPOWER 1/6 1/4 1/4 1/4 FAN MOTOR RPM 815 830 1075 830 FULL LOAD AMPS 1.10 1.5 1.4 1.5 LOCKED ROTOR AMPS 1.7 3.0 2.9 3.0 BLADE DIAMETER (INCHES) 22 22 22 22 3 3 3 3 CFM 2400 2700 2700 2700 CONDENSER FACE AREA - SQ. FT. 12.3 12.3 12.3 12.3 COIL NUMBER OF ROWS 1 2 1 2 FINS PER INCH 22 16 22 16 COMPRESSOR CONDENSER FAN NUMBER OF BLADES EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - X-13 1/2 - X-13 1/2 - X-13 1/2 - X-13 BLOWER FULL LOAD AMPS 4.1 1.86 4.1 1.86 MOTOR LOCKED ROTOR AMPS N/A N/A N/A N/A MOTOR SPEED TAP - COOLING T4 T3, T4 T3, T4 T3, T4 724 / 1.21 960 / 3.06 640 / 0.98 960 / 3.06 960 / 3.06 RPM / AMPS EVAPORATOR DIAMETER X WIDTH (INCHES) 10 x 8 10 x 9 10 x 9 10 x 9 BLOWER RATED SCFM COOLING 845 1050 800 / 1225 1050 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 0.5 EVAPORATOR FACE AREA - SQ. FT. 4.33 4.33 4.33 4.33 COIL NUMBER OF ROWS 2 3 4 4 FINS PER INCH 14 14 14 14 4.2 FILTER SIZE - SQ. FT.(2) 2.7 4.2 4.2 DRAIN SIZE (INCHES) 3/4 3/4 3/4 3/4 HEATING PRIMARY LIMIT SETTING (°F) 160 160 160 160 LIMITS AUXILIARY LIMIT SETTING (°F) 150 150 150 150 ROLLOUT LIMIT SETTING (°F) 300 300 300 300 GENERAL EXPANSION DEVICE TXV 0.065 TXV TXV INFORMATION REFRIGERANT CHARGE R-410A (Oz.) 81 102 99 112 1 1/8 1 1/8 1 1/8 1 1/8 POWER SUPPLY ENTRANCE SIZE (INCHES) LOW VOLTAGE ENTRANCE SIZE (INCHES) 7/8 7/8 7/8 7/8 SHIPPING WEIGHT LBS. 439 475 480 480 OPERATING WEIGHT LBS. 417 453 458 458 (1) Units installed in Canada are certifed only to 4500 feet. (2) Calculated external filter size based on air velocity of 300 ft/min. and applies to disposable filters only. (3) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. 8 PACKAGE GAS SPECIFICATIONS *PG154211541AA *PG15[42-60]***41AA *PG154811541AA *PG154911541AA *PG156014041AA 56,500 COOLING CAPACITY, BTUH HIGH STAGE 40,000 47,500 47,000 LOW STAGE N/A 35,000 33,000 41,000 14.5 / 12.0 15.0 / 11.0 15.0 / 12.0 14.0 / 10.1 SEER/EER BTUH INPUT (US) HIGH FIRE 115,000 115,000 115,000 138,000 OUTPUT (US) HIGH FIRE (Natural Gas) 92,000 92,000 92,000 110,200 OUTPUT (US) HIGH FIRE (LP) 83,000 83,000 83,000 99,000 86,000 86,000 86,000 103,000 BTUH INPUT (US) LOW FIRE OUPUT (US) LOW FIRE (Natural) 69,000 69,000 69,000 83,000 OUTPUT (US) LOW FIRE (LP) 62,000 62,000 62,000 74,000 A.F.U.E. RATED EXTERNAL STATIC (" w.c.) TEMPERATURE RISE (°F) PRESSURE SWITCH TRIP POINT (" w.c.) VOLTAGE (NAMEPLATE) 80 80 80 80 0.50 0.50 0.50 0.50 45-75 45-75 45-75 45-75 -.33" -.33" -.33" -.33" 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 UNIT AMPS (TOTAL) 22.2 29.4 25.5 35.6 MINIMUM CIRCUIT AMPACITY 26.6 34.8 30.8 42.1 MAXIMUM OVERCURRENT PROTECTION(3) NUMBER OF BURNERS 40 50 50 60 5 5 5 6 ORIFICE SIZE NATURAL 43 43 43 43 ORIFICE SIZE LP 55 55 55 55 Scroll Scroll Scroll Scroll RATED LOAD AMPS 17.9 21.2 21.2 25.6 LOCKED ROTOR AMPS 112 96 96 118 HORSEPOWER 1/4 1/3 1/4 1/3 1075 1075 1075 1075 TYPE RPM FULL LOAD AMPS 1.4 2.5 1.4 2.5 LOCKED ROTOR AMPS 2.9 5.8 2.9 5.2 BLADE DIAMETER (INCHES) 22 22 22 22 3 4 3 4 CFM 3500 3500 3500 3500 FACE AREA - SQ. FT. 15.3 15.3 15.3 15.3 2 2 2 2 16 16 16 16 NUMBER OF BLADES NUMBER OF ROWS FINS PER INCH HORSEPOWER - NO. OF SPEEDS 3/4 - X-13 3/4 - X-13 3/4 - X-13 1 - X-13 FULL LOAD AMPS 2.87 6.00 2.87 7.60 LOCKED ROTOR AMPS N/A N/A N/A N/A T3, T4 T3, T4 T3, T4 T3,T4 RPM / AMPS 890 / 3.8 647 / 1.66 890 / 3.8 890 / 3.8 778 / 1.98 1030 / 5.7 DIAMETER X WIDTH (INCHES) 11 x 10 11 x 10 11 x 10 11 x 10 1200 1100 / 1510 1300 1300 / 1810 MOTOR SPEED TAP - COOLING RATED SCFM COOLING MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 0.5 FACE AREA - SQ. FT. 5.67 5.67 5.67 5.67 NUMBER OF ROWS 4 4 4 4 FINS PER INCH 14 14 14 14 6.3 FILTER SIZE - SQ. FT.( 2) 5.1 5.1 5.1 DRAIN SIZE (INCHES) 3/4 3/4 3/4 3/4 PRIMARY LIMIT SETTING (° F) 170 170 170 160 150 AUXILIARY LIMIT SETTING (°F) 150 150 150 ROLLOUT LIMIT SETTING (°F) 300 300 300 300 0.072 TXV TXV TXV EXPANSION DEVICE REFRIGERANT CHARGE R-410A (Oz.) POWER SUPPLY ENTRANCE SIZE (INCHES) 162 169 167 177 1 1/8 1 1/8 1 1/8 1 1/8 LOW VOLTAGE ENTRANCE SIZE (INCHES) 7/8 7/8 7/8 7/8 SHIPPING WEIGHT LBS. 560 560 560 565 OPERATING WEIGHT LBS. 538 538 538 543 (1) Units installed in Canada are certifed only to 4500 feet. (2) Calculated external filter size based on air velocity of 300 ft/min. and applies to disposable filters only. (3) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. 9 PACKAGE GAS SPECIFICATIONS COOLING CAPACITY *PG153609041AB * PG154811541AB *PG156014041AB HIGH STAGE 35,400 47,500 56,500 LOW STAGE 24,400 35,000 41,000 15.0 / 11.0 15.0 / 11.0 14.0 / 10.1 COOLING CAPACITY, BT UH SEER/EER HEATING CAPACITY *PG15[36-60]***41AB BTUH INPUT (US) HIGH FIRE 92,000 115,000 138,000 OUTPUT (US) HIGH FIRE (Natural Gas) 73,500 92,000 110,200 OUTPUT (US) HIGH FIRE (LP) 69,000 83,000 99,000 69,000 86,000 103,500 OUPUT (US) LOW FIRE (Natural) 55,000 69,000 83,000 OUTPUT (US) LOW FIRE (LP) 50,000 62,000 74,000 80 80 80 0.50 0.50 0.50 TEMPERATURE RISE (°F) 45-75 45-75 45-75 PRESSURE SWITCH TRIP POINT (" w.c.) -.33" -.33" -.33" 208-230/1/60 208-230/1/60 208-230/1/60 BTUH INPUT (US) LOW FIRE A.F.U.E. RATED EXTERNAL STATIC (" w.c.) UNIT VOLTAGE (NAMEPLATE) EL ECTRICAL UNIT AMPS (TOTAL) 22.3 20.1 34.6 26.5 34.8 42.1 MAXIMUM OVERCURRENT PROTECTION 40 50 60 HEATING NUMBER OF BURNERS 4 5 6 SECTION ORIFICE SIZE NATURAL 43 43 43 SPECIFICATION MINIMUM CIRCUIT AMPACITY ( 3) ORIFICE SIZE LP COMPRESSOR TYPE RATED LOAD AMPS 55 55 55 Scroll Scroll Scroll 16.7 21.2 25.8 LOCKED ROTOR AMPS 82 96 118 CONDENSER HORSEPOWER 1/4 1/4 1/4 FAN MOTOR RPM 830 1075 1075 FULL LOAD AMPS 1.5 1.4 1.4 LOCKED ROTOR AMPS 3.0 5.2 5.2 BLADE DIAMETER (INCHES) 22 22 22 3 3 3 CFM 2700 3500 3500 CONDENSER FACE AREA - SQ. FT. 12.3 15.3 15.3 COIL NUMBER OF ROWS 1 2 2 FINS PER INCH 22 16 16 1 - X-13 CONDENSER FAN NUMBER OF BLADES EVAPORATOR HORSEPOWER - NO. OF SPEEDS 1/2 - X-13 3/4 - X-13 BLOWER FULL LOAD AMPS 4.1 6 7.6 MOTOR LOCKED ROTOR AMPS N/A N/A N/A MOT OR SPEED TAP - COOLING RPM / AMPS EVAPORATOR DIAMETER X WIDT H (INCHES) BLOWER RATED SCFM COOLING T3, T4 T3, T4 T3,T 4 640 / 0.98 960 / 3.06 647 / 1.66 890 / 3.8 778 / 1.98 1030 / 5.7 10 x 9 11 x 10 11 x 10 800 / 1225 1100 / 1510 1300 / 1810 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 EVAPORATOR FACE AREA - SQ. FT. 4.33 5.67 5.67 COIL NUMBER OF ROWS 4 4 4 FINS PER INCH 14 14 14 (2) 4.2 5.1 6.3 DRAIN SIZE (INCHES) 3/4 3/4 3/4 HEATING PRIMARY LIMIT SETTING (°F) 160 170 160 LIMITS AUXILIARY LIMIT SETTING (°F) 150 150 150 FILTER SIZE - SQ. FT . ROLLOUT LIMIT SETTING (°F ) 300 300 300 GENERAL EXPANSION DEVICE TXV TXV TXV INFORMATION REFRIGERANT CHARGE R-410A (Oz.) 102 172 180 POWER SUPPLY ENTRANCE SIZ E (INCHES 1 1/8 1 1/8 1 1/8 LOW VOLTAGE ENTRANCE SIZE (INCHES) 7/8 7/8 7/8 SHIPPING WEIGHT LBS. 480 560 565 OPERATING WEIGHT LBS. 458 538 543 (1) Units installed in Canada are certifed only to 4500 feet. (2) Calculated external filter size based on air velocity of 300 ft/min. and applies to disposable filters only. (3) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers in accordance with the National Electrical Code and/or all local codes. 10 ACCESSORIES ACCESSORIES Part Number Description LPM-06 Propane Conversion Kit HA-02 High Altitude Kit PGC101/102/103 Roof Curb PGED101/102 Downflow Economizer, Small and Medium Chassis PGED103 Downflow Economizer, Large Chassis PGEH101/102 Horizontal Economizer, Small and Medium Chassis PGEH103 Horizontal Economizer, Large Chassis PGMDD101/102 Manual 25% Fresh Air Damper Downflow Application, Small and Medium Chassis PGMDD103 Manual 25% Fresh Air Damper Downflow Application, Large Chassis PGMDH101 Manual 25% Fresh Air Damper Horizontal Application, Small Chassis PGMDH102 Manual 25% Fresh Air Damper Horizontal Application, Medium Chassis PGMDH103 Manual 25% Fresh Air Damper Horizontal Application, Large Chassis PGMDMD101/102 Motorized 25% Fresh Air Damper Downflow Application,Small and Medium Chassis PGMDMD103 Motorized 25% Fresh Air Downflow Application, Large Chassis PGMDMH101 Motorized 25% Fresh Air Damper Horizontal Application, Small Chassis PGMDMH102 Motorized 25% Fresh Air Damper Horizontal Application, Medium Chassis PGMDMH103 Motorized 25% Fresh Air Damper Horizontal Application, Large Chassis SQRPG101/102 Square to Round Adapter w/ 16" Round Downflow Application, Small and Medium Chassis SQRPG103 Square to Round Adapter w/ 18" Round Downflow Application, Large Chassis SQRPGH101/102 Square to Round Adapter w/ 16" Round Horizontal Application, Small and Medium Chassis SQRPGH103 Square to Round Adapter w/ 18" Round Horizontal Application, Large Chassis PGFR101/102/103 Internal Filter Rack All Chassis GPGHFR101-103 External Horizontal Filter Rack for Goodman/Amana Gas/Electric & Multi-position Package Units All Chassis CDK36 Flush Mount Concentric Duct Kit CDK36515 Flush Mount Concentric Duct Kit w/ Filter CDK36530 Step Down Concentric Duct Kit CDK36535 Step Down Concentric Duct Kit w/ Filter CDK4872 Flush Mount Concentric Duct Kit CDK4872515 Flush Mount Concentric Duct Kit w/ Filter CDK4872530 Step Down Concentric Duct Kit CDK4872535 Step Down Concentric Duct Kit w/ Filter NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. 11 *PG15[24-36]***41A* BLOWER PERFORMANCE DATA *PG15240701A* - Rise Range: 35° - 65° Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 T1 - 1st Stage Heating Speed CFM WATTS AMPS RISE 742 84 0.75 52 677 89 0.82 57 631 97 0.90 62 575 101 0.92 X 526 111 1.01 X - T2 - 2nd Stage Heating Speed CFM WATTS AMPS RISE 907 134 1.18 57 857 140 1.24 61 814 149 1.32 64 761 154 1.33 X 727 165 1.41 X 678 169 1.47 X - T3 - Cooling Speed CFM WATTS AMPS 857 116 1.04 816 126 1.16 760 131 1.18 721 140 1.25 670 145 1.31 629 155 1.39 - T4 - Cooling Spped CFM WATTS AMPS 907 134 1.18 857 140 1.24 814 149 1.32 761 154 1.33 727 165 1.41 678 169 1.47 - T5 - Cooling Spped CFM WATTS AMPS 1,040 185 1.33 988 198 1.40 949 208 1.42 903 213 1.49 871 222 1.55 824 228 1.58 - *PG153009041A* - Rise Range: 45° -75° Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 T1 - 1st Stage Heating Speed CFM 1,065 1,003 961 913 855 814 749 713 WATTS 168 174 185 195 202 212 218 227 AMPS 1.42 1.48 1.55 1.62 1.69 1.76 1.82 1.87 RISE 49 52 54 57 60 63 69 72 T2 - 2nd Stage Heating Speed CFM 1,255 1,217 1,165 1,113 1,073 1,018 991 - WATTS 257 269 274 285 296 302 313 - AMPS 2.10 2.19 2.21 2.30 2.36 2.41 2.48 - RISE 55 57 59 62 64 68 70 - T3 Cooling Spped CFM WATTS 1,148 170 1,092 176 1,044 184 994 194 929 210 811 222 763 224 715 236 AMPS 1.55 1.66 1.72 1.77 1.89 1.99 2.03 2.07 T4 - Cooling Speed CFM 1,148 1,092 1,044 994 929 811 763 715 WATTS 170 176 184 194 210 222 224 236 AMPS 1.55 1.66 1.72 1.77 1.89 1.99 2.03 2.07 T5 - Cooling Speed CFM 1,333 1,293 1,237 1,193 1,158 1,101 - WATTS 304 314 321 333 341 345 - AMPS 2.41 2.48 2.54 2.71 2.77 2.78 - *PG153609041A* - Rise Range: 45° -75° Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 T1 - 1st Stage Heating Speed CFM WATTS AMPS RISE 1,065 168 1.42 49 1,003 174 1.48 52 961 185 1.55 54 913 195 1.62 57 855 202 1.69 60 814 212 1.76 63 749 218 1.82 69 713 227 1.87 72 T2 - 2nd Stage Heating Speed CFM WATTS AMPS RISE 1,255 257 2.10 55 1,217 269 2.19 57 1,165 274 2.21 59 1,113 285 2.30 62 1,073 296 2.36 64 1,018 302 2.41 68 991 313 2.48 70 - T3 - 1st Stage Cooling CFM WATTS AMPS 924 120 1.08 863 128 1.14 812 138 1.24 745 145 1.27 702 154 1.35 643 159 1.37 601 168 1.44 502 173 1.52 T4 - 2nd Stage Cooling CFM WATTS AMPS 1,333 304 2.41 1,293 314 2.48 1,237 321 2.54 1,193 333 2.71 1,158 341 2.77 1,101 345 2.78 - T5 - Cooling Speed CFM WATTS AMPS 1,418 360 2.92 1,375 371 3.00 1,316 376 3.05 1,279 387 3.13 1,245 392 3.19 1,193 400 3.22 - T2 - 2nd Stage Heating Speed T3 Cooling Spped T4 Cooling Speed T5 - Cooling Speed *PG153709041A* - Rise Range: 45° -75° T1 - 1st Stage Heating Speed Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 CFM 1,065 1,003 961 913 855 814 749 713 WATTS 168 174 185 195 202 212 218 227 AMPS 1.42 1.48 1.55 1.62 1.69 1.76 1.82 1.87 RISE 49 52 54 57 60 63 69 72 CFM 1,255 1,217 1,165 1,113 1,073 1,018 991 - WATTS 257 269 274 285 296 302 313 - AMPS 2.10 2.19 2.21 2.30 2.36 2.41 2.48 - RISE 55 57 59 62 64 68 70 - CFM WATTS 1,148 170 1,092 176 1,044 184 994 194 929 210 811 222 763 224 715 236 AMPS 1.55 1.66 1.72 1.77 1.89 1.99 2.03 2.07 CFM 1,148 1,092 1,044 994 929 811 763 715 WATTS 170 176 184 194 210 222 224 236 AMPS 1.55 1.66 1.72 1.77 1.89 1.99 2.03 2.07 CFM 1,418 1,375 1,316 1,279 1,245 1,193 - WATTS 360 371 376 387 392 400 - AMPS 2.92 3.00 3.05 3.13 3.19 3.22 - X = Outside of Temperature Rise Range - Not Recommended. NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, external static pressure should not exceed 0.5" w.c. 12 BLOWER PERFORMANCE DATA *PG15[42-60]***41A* *PG154211541A* - Rise Range: 45° -75° T1 - 1st Stage Heating Speed T2 - 2nd Stage Heating Speed T3 Cooling Spped T4 Cooling Speed T5 - Cooling Speed Unit Static CFM WATTS AMPS RISE CFM WATTS AMPS RISE CFM WATTS AMPS CFM WATTS AMPS CFM WATTS AMPS 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1,065 1,003 961 913 855 814 749 713 168 174 185 195 202 212 218 227 1.42 1.48 1.55 1.62 1.69 1.76 1.82 1.87 49 52 54 57 60 63 69 72 1,255 1,217 1,165 1,113 1,073 1,018 991 - 257 269 274 285 296 302 313 - 2.10 2.19 2.21 2.30 2.36 2.41 2.48 - 55 57 59 62 64 68 70 - 1,335 1,274 1,204 1,136 1,069 1,009 946 886 260 268 281 287 300 312 319 331 1.01 1.04 1.10 1.11 1.15 1.19 1.22 1.27 1,468 1,412 1,346 1,275 1,221 1,170 1,105 1,042 337 349 359 363 370 386 397 406 1.28 1.33 1.37 1.40 1.44 1.47 1.52 1.54 1,619 1,560 1,504 1,441 1,380 1,325 1,268 1,198 431 445 456 463 475 489 495 502 1.64 1.69 1.71 1.76 1.80 1.84 1.88 1.90 *PG154811541A* - Rise Range: 45° - 75° Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 T1 - 1st Stage Heating Speed CFM WATTS AMPS RISE 1140 178 1.52 56 1090 188 1.57 59 1038 199 1.67 62 980 212 1.76 65 914 220 1.79 70 852 231 1.9 75 806 242 1.97 X 741 248 2.01 X T2 - 2nd Stage Heating Speed CFM WATTS AMPS RISE 1417 305 2.46 61 1374 318 2.56 63 1322 327 2.68 65 1273 338 2.72 68 1224 352 2.82 70 1176 365 2.88 73 1121 379 2.93 X 1068 391 2.98 X T3 - 1st Stage Cooling CFM WATTS AMPS 1,140 178 1.52 1,090 188 1.57 1,038 199 1.67 980 212 1.76 914 220 1.79 852 231 1.90 806 242 1.97 741 248 2.01 T4 - 2nd Stage Cooling CFM WATTS AMPS 1,616 436 3.34 1,573 449 3.46 1,527 462 3.59 1,485 474 3.69 1,443 489 3.80 1,399 502 3.86 1,356 513 3.99 1,307 525 4.05 T5 - Cooling Spped CFM WATTS AMPS 1,696 503 4.04 1,650 517 4.15 1,608 530 4.25 1,566 543 4.39 1,523 556 4.43 1,480 569 4.55 1,441 580 4.65 - T2 - 2nd Stage Heating Speed CFM WATTS AMPS RISE 61 1417 305 2.46 1374 318 2.56 63 1322 327 2.68 65 1273 338 2.72 68 1224 352 2.82 70 1176 365 2.88 73 1121 379 2.93 X 1068 391 2.98 X T3 - 1st Stage Cooling CFM WATTS AMPS 1140 178 1.52 1090 188 1.57 1038 199 1.67 980 212 1.76 914 220 1.79 852 231 1.9 806 242 1.97 741 248 2.01 T4 - 2nd Stage Cooling CFM WATTS AMPS 1,468 1,412 1,346 1,275 1,221 1,170 1,105 1,042 T5 - Cooling Speed CFM WATTS AMPS 1,696 503 4.04 1,650 517 4.15 1,608 530 4.25 1,566 543 4.39 1,523 556 4.43 1,480 569 4.55 1,441 580 4.65 - T3 - 1st Stage Cooling CFM WATTS AMPS 1,379 246 1.95 1,322 258 2.03 1,268 266 2.10 1,187 280 2.19 1,133 287 2.23 1,068 294 2.29 1,026 307 2.38 - T4 - 2nd Stage Cooling CFM WATTS AMPS 1,919 700 4.81 1,862 714 4.94 1,810 720 5.01 1,755 734 5.07 1,705 743 5.09 1,647 748 5.16 - *PG154911541A* - Rise Range: 45° - 75° Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 T1 - 1st Stage Heating Speed CFM WATTS AMPS RISE 56 1140 178 1.52 1090 188 1.57 59 1038 199 1.67 62 980 212 1.76 65 914 220 1.79 70 852 231 1.9 75 806 242 1.97 X 741 248 2.01 X *PG156014041A* - Rise Range: 45° - 75° High Unit Static 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 T1 - 1st Stage Heating Speed CFM WATTS AMPS RISE 1773 488 3.64 43 1713 501 3.73 45 1693 509 3.78 45 1653 518 3.84 46 1597 529 3.91 48 1534 541 3.99 50 1485 552 4.09 52 - 337 349 359 363 370 386 397 406 1.28 1.33 1.37 1.40 1.44 1.47 1.52 1.54 30° - 60° Low T2 - 2nd Stage Heating Speed CFM WATTS AMPS RISE 1773 488 3.64 58 1713 501 3.73 61 1693 509 3.78 61 1653 518 3.84 63 1597 529 3.91 65 1534 541 3.99 68 1485 552 4.09 70 - T5 - Cooling Speed CFM WATTS AMPS 2,115 783 5.54 2,078 787 5.57 2,009 802 5.67 1,953 813 5.87 1,933 805 5.77 - X = Outside of Temperature Rise Range - Not Recommended. NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, external static pressure should not exceed 0.5" w.c. 13 14 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 BTU OUTPUT vs TEMPERATURE RISE CHART 150 BLOWER PERFORMANCE DATA TEMPERATURE RISE EXPANDED PERFORMANCE DATA 20.4 0.72 18 1.46 6.8 218 105 23.1 0.89 20 1.52 7.1 229 110 22.4 0.85 21 1.51 7.0 227 109 20.7 0.82 21 1.47 6.9 220 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 845 739 951 739 845 23.1 0.76 19 1.54 7.2 244 116 21.3 0.73 19 1.50 7.0 237 113 23.8 0.80 18 1.55 7.2 246 117 21.1 0.60 16 1.49 7.0 234 112 22.9 0.62 16 1.53 7.1 241 115 23.6 0.65 15 1.54 7.2 244 116 25.0 0.57 16 1.59 7.4 257 127 23.1 0.55 16 1.55 7.2 250 123 25.8 0.60 15 1.60 7.4 260 128 23.1 0.42 12 1.54 7.1 247 122 25.1 0.43 12 1.57 7.3 255 126 25.8 0.45 11 1.59 7.4 257 127 26.8 0.37 11 1.64 7.6 269 135 24.8 0.36 11 1.60 7.4 260 131 27.7 0.39 10 1.65 7.6 271 136 - - - 21.9 0.88 21 1.62 7.5 254 115 20.2 0.85 21 1.58 7.3 247 112 22.6 0.92 20 1.64 7.6 257 117 19.9 0.75 18 1.57 7.3 244 111 21.6 0.77 18 1.61 7.4 252 114 22.2 0.81 17 1.62 7.5 254 115 22.6 0.79 19 1.66 7.7 274 123 20.8 0.76 20 1.62 7.5 265 119 23.3 0.83 19 1.67 7.7 276 124 20.6 0.62 16 1.60 7.4 263 118 22.3 0.65 16 1.64 7.6 271 122 23.0 0.68 15 1.66 7.7 274 123 24.4 0.60 16 1.71 7.9 289 134 22.6 0.57 16 1.67 7.7 280 130 25.2 0.62 15 1.72 7.9 292 135 22.6 0.43 12 1.66 7.6 277 129 24.5 0.45 12 1.70 7.8 286 133 25.2 0.47 11 1.71 7.9 289 134 26.2 0.38 11 1.77 8.1 301 143 24.2 0.37 11 1.72 7.9 292 138 27.0 0.40 10 1.78 8.2 304 144 - - - 21.4 0.90 21 1.72 8.0 289 120 19.8 0.87 21 1.68 7.9 280 116 22.0 0.95 20 1.74 8.1 292 121 19.4 0.77 18 1.67 7.8 278 115 21.0 0.79 18 1.71 8.0 286 119 21.7 0.83 17 1.72 8.0 289 120 22.0 0.81 19 1.76 8.2 311 128 20.3 0.78 20 1.72 8.0 302 124 22.7 0.85 19 1.78 8.3 314 129 20.1 0.64 16 1.70 8.0 299 123 21.8 0.66 16 1.75 8.1 308 126 22.5 0.70 15 1.76 8.2 311 128 23.9 0.61 16 1.82 8.4 329 139 22.0 0.59 16 1.77 8.2 319 135 24.6 0.64 15 1.84 8.5 332 141 22.1 0.44 12 1.76 8.2 315 134 23.9 0.46 12 1.80 8.4 325 138 24.6 0.48 11 1.82 8.4 328 139 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 22.1 0.75 18 1.49 7.0 224 108 MBh S/T Delta T KW AMPS HI PR LO PR 951 22.7 0.78 17 1.51 7.0 227 109 MBh S/T Delta T KW AMPS HI PR LO PR 25.6 0.39 11 1.88 8.7 343 148 23.6 0.38 11 1.83 8.5 332 144 26.4 0.41 11 1.90 8.8 346 150 - - - 20.9 0.93 21 1.82 8.5 329 126 19.3 0.90 22 1.77 8.3 319 122 21.5 0.98 20 1.83 8.6 333 127 19.0 0.79 19 1.76 8.2 316 121 20.5 0.82 18 1.80 8.4 326 125 21.1 0.86 18 1.82 8.5 329 126 21.5 0.83 19 1.86 8.7 354 134 19.8 0.80 20 1.81 8.5 344 130 22.1 0.87 19 1.87 8.7 358 135 19.6 0.66 16 1.79 8.4 340 129 21.3 0.68 16 1.84 8.6 351 133 21.9 0.72 15 1.86 8.7 354 134 23.3 0.63 16 1.92 8.9 374 146 21.5 0.61 16 1.87 8.7 363 142 24.0 0.66 15 1.93 9.0 378 148 21.5 0.46 12 1.85 8.6 359 140 23.3 0.47 12 1.90 8.9 370 145 24.0 0.50 12 1.92 8.9 374 146 19.8 0.97 21 1.89 9.0 370 132 18.3 0.93 21 1.84 8.8 359 128 20.4 1.00 20 1.91 9.0 374 133 18.0 0.82 18 1.83 8.7 356 127 19.5 0.85 18 1.88 8.9 367 131 20.1 0.89 17 1.89 9.0 370 132 20.4 0.86 19 1.93 9.2 399 140 18.9 0.83 20 1.89 8.9 387 136 21.0 0.91 18 1.95 9.2 403 142 18.7 0.69 16 1.87 8.9 383 135 20.2 0.71 16 1.92 9.1 395 139 20.8 0.74 15 1.93 9.2 399 140 22.1 0.65 16 2.00 9.4 421 153 20.4 0.63 16 1.95 9.2 408 149 22.8 0.69 15 2.02 9.5 425 155 20.4 0.47 12 1.93 9.1 404 147 22.2 0.49 12 1.98 9.3 417 152 22.8 0.52 11 2.00 9.4 421 153 23.7 0.42 11 2.07 9.7 439 163 21.9 0.41 11 2.01 9.5 426 158 24.4 0.44 10 2.08 9.8 443 165 - - - 18.4 0.98 19 1.96 9.4 409 137 17.0 0.94 20 1.91 9.2 397 132 18.9 1.00 18 1.98 9.5 413 138 16.7 0.83 17 1.89 9.1 393 131 18.1 0.86 17 1.94 9.4 405 135 18.6 0.90 16 1.96 9.4 409 137 63 18.9 0.87 18 2.00 9.6 441 145 17.5 0.84 18 1.95 9.4 427 141 19.5 0.91 17 2.02 9.7 445 147 17.3 0.69 15 1.94 9.3 423 139 18.7 0.72 15 1.99 9.6 436 144 19.3 0.75 14 2.00 9.6 440 145 67 20.5 0.66 15 2.07 9.9 465 159 18.9 0.64 15 2.02 9.7 451 154 21.1 0.69 14 2.09 10.0 470 160 18.9 0.48 11 2.00 9.6 447 152 20.5 0.50 11 2.05 9.8 460 157 21.1 0.52 11 2.07 9.9 465 159 22.0 0.42 10 2.14 10.2 485 169 20.3 0.41 10 2.09 10.0 471 164 22.6 0.45 10 2.16 10.3 490 171 - - - 71 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 25.0 0.41 11 1.98 9.2 390 156 23.1 0.39 11 1.93 9.0 379 151 25.7 0.43 11 2.00 9.3 394 157 - - - 115 COOLING OPERATION Design Subcooling, 10 °F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 °F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 IDB* Airflow 59 63 MODEL: *PG1524***41A* COOLING PERFORMANCE DATA *PG1524***41A* 15 16 MODEL: *PG1524***41A* EXPANDED PERFORMANCE DATA 21.1 0.90 24 1.48 6.9 222 107 23.9 1.00 23 1.54 7.2 233 113 23.2 0.98 25 1.53 7.1 231 111 21.5 0.94 25 1.49 7.0 224 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 845 739 951 845 739 21.9 0.91 25 1.53 7.1 241 115 23.7 0.94 24 1.56 7.3 249 119 24.4 0.99 23 1.58 7.3 251 120 21.5 0.84 23 1.51 7.1 239 114 23.3 0.87 22 1.55 7.2 246 117 22.9 0.82 23 1.57 7.3 255 126 24.8 0.85 23 1.61 7.5 263 129 25.6 0.89 22 1.63 7.5 265 131 23.0 0.69 20 1.56 7.3 252 124 24.9 0.71 19 1.60 7.4 260 128 24.4 0.67 20 1.62 7.5 266 134 26.5 0.69 20 1.66 7.7 274 138 27.3 0.72 19 1.68 7.8 277 139 24.6 0.51 16 1.61 7.5 263 132 26.7 0.53 15 1.65 7.7 271 136 21.0 0.98 25 1.61 7.4 252 114 22.7 1.00 25 1.65 7.6 259 118 23.4 1.00 23 1.66 7.7 262 119 20.6 0.93 24 1.60 7.4 249 113 22.3 0.97 23 1.64 7.6 257 117 21.4 0.94 25 1.64 7.6 271 121 23.1 0.98 25 1.68 7.8 279 125 23.8 1.00 23 1.70 7.8 282 126 21.0 0.87 23 1.63 7.5 268 120 22.8 0.91 22 1.67 7.7 276 124 22.4 0.85 24 1.70 7.8 286 133 24.2 0.88 23 1.74 8.0 295 137 25.0 0.92 22 1.75 8.0 298 138 22.5 0.71 20 1.68 7.7 283 131 24.4 0.74 20 1.73 7.9 292 135 23.9 0.69 20 1.75 8.0 298 141 25.9 0.72 20 1.80 8.2 307 146 26.6 0.75 19 1.81 8.3 310 147 24.0 0.53 16 1.74 8.0 295 140 26.0 0.55 16 1.78 8.2 304 144 20.5 1.00 25 1.71 8.0 286 119 22.2 1.00 24 1.75 8.2 295 122 22.8 1.00 22 1.77 8.2 298 124 20.1 0.95 24 1.70 7.9 283 118 21.8 0.99 23 1.74 8.1 292 121 20.9 0.97 25 1.75 8.1 308 126 22.6 1.00 25 1.79 8.3 317 130 23.3 1.00 23 1.81 8.4 321 131 20.5 0.90 23 1.73 8.1 305 125 22.3 0.93 22 1.78 8.3 314 129 21.8 0.87 24 1.80 8.4 325 138 23.7 0.90 23 1.85 8.6 335 142 24.4 0.95 22 1.87 8.6 339 144 21.9 0.73 20 1.79 8.3 322 136 23.8 0.76 20 1.84 8.5 332 141 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 22.8 0.93 23 1.52 7.1 229 110 MBh S/T Delta T KW AMPS HI PR LO PR 23.3 0.71 20 1.86 8.6 339 147 25.2 0.73 20 1.91 8.8 350 151 26.0 0.77 19 1.93 8.9 353 153 23.5 0.54 16 1.85 8.6 336 145 25.4 0.56 16 1.90 8.8 346 150 20.0 1.00 25 1.80 8.4 326 125 21.6 1.00 24 1.85 8.6 336 129 22.3 1.00 22 1.86 8.7 339 130 19.6 0.99 24 1.78 8.4 323 123 21.3 1.00 23 1.83 8.6 333 127 20.3 1.00 25 1.84 8.6 351 133 22.0 1.00 24 1.89 8.8 362 137 22.7 1.00 22 1.90 8.9 365 138 20.0 0.92 23 1.82 8.5 347 131 21.7 0.96 23 1.87 8.8 358 135 21.3 0.90 24 1.90 8.9 370 145 23.1 0.93 23 1.95 9.1 382 149 23.8 0.98 22 1.97 9.1 386 151 21.4 0.75 20 1.88 8.8 367 143 23.2 0.78 20 1.93 9.0 378 148 19.0 1.00 24 1.88 8.9 367 131 20.5 1.00 22 1.92 9.1 378 135 21.2 1.00 20 1.94 9.2 382 136 18.6 1.02 24 1.86 8.8 363 129 20.2 1.00 22 1.91 9.0 374 133 19.3 1.00 24 1.92 9.1 395 139 20.9 1.00 23 1.97 9.3 407 143 21.6 1.00 21 1.98 9.4 411 145 19.0 0.96 23 1.90 9.0 391 138 20.6 0.99 22 1.95 9.2 403 142 20.2 0.93 23 1.98 9.3 417 152 21.9 0.97 23 2.03 9.6 430 156 22.6 1.00 22 2.05 9.7 434 158 20.3 0.78 20 1.96 9.3 412 150 22.0 0.81 19 2.02 9.5 425 155 21.6 0.76 20 2.05 9.7 435 162 23.4 0.79 20 2.10 9.9 448 167 24.1 0.82 19 2.12 10.0 452 168 21.7 0.58 16 2.03 9.6 430 160 23.6 0.61 16 2.08 9.8 444 165 17.6 1.00 22 1.94 9.3 405 135 19.0 1.00 21 1.99 9.6 418 139 19.6 1.00 19 2.01 9.7 422 141 17.3 1.03 22 1.93 9.3 401 134 18.7 1.00 20 1.98 9.5 413 138 17.9 1.00 22 1.99 9.5 436 144 19.4 1.00 21 2.04 9.8 449 148 20.0 1.00 19 2.05 9.9 454 150 17.6 0.97 21 1.97 9.5 432 142 19.1 1.00 21 2.02 9.7 445 147 18.7 0.94 22 2.05 9.8 460 157 20.3 0.98 22 2.11 10.1 475 162 20.9 1.00 20 2.12 10.2 479 163 18.8 0.79 18 2.03 9.7 456 155 20.4 0.82 18 2.09 10.0 470 160 67 21.0 0.86 17 2.11 10.1 475 162 20.0 0.76 19 2.12 10.2 480 167 21.7 0.79 19 2.18 10.4 495 172 22.3 0.83 18 2.20 10.5 500 174 20.1 0.59 15 2.10 10.1 475 165 21.8 0.61 14 2.16 10.3 490 171 71 22.5 0.64 14 2.18 10.4 495 172 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 22.7 0.73 21 1.96 9.1 386 154 24.6 0.76 20 2.01 9.4 398 159 25.4 0.79 19 2.03 9.4 402 161 22.9 0.56 16 1.95 9.1 382 153 24.8 0.58 16 2.00 9.3 394 157 63 19.7 1.00 19 2.04 9.8 449 148 115 COOLING OPERATION Design Subcooling, 10 °F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 °F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 23.5 24.0 25.7 27.5 23.0 23.5 25.1 26.8 22.4 22.9 24.5 26.2 21.9 22.4 23.9 25.5 20.8 21.2 22.7 24.3 19.3 S/T 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.79 0.59 1.00 1.00 0.82 0.61 1.00 1.00 0.85 0.63 1.00 Delta T 23 21 19 15 22 22 19 15 22 22 19 15 21 22 19 15 20 21 19 15 19 951 KW 1.53 1.56 1.61 1.66 1.65 1.68 1.74 1.80 1.75 1.79 1.85 1.91 1.85 1.89 1.95 2.01 1.92 1.97 2.03 2.10 1.99 AMPS 7.1 7.3 7.5 7.7 7.6 7.8 8.0 8.2 8.2 8.3 8.6 8.8 8.6 8.8 9.1 9.4 9.1 9.3 9.6 9.9 9.6 HI PR 231 249 263 274 259 279 295 307 295 317 335 350 336 362 382 398 378 407 430 448 418 LO PR 111 119 129 138 118 125 137 146 122 130 142 151 129 137 149 159 135 143 156 167 139 COOLING PERFORMANCE DATA *PG1524***41A* EXPANDED PERFORMANCE DATA 25.9 0.70 19 1.79 8.7 217 101 29.4 0.87 21 1.86 9.0 228 106 28.5 0.83 22 1.85 9.0 226 105 26.3 0.80 22 1.80 8.8 219 102 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1000 875 1125 875 1000 29.4 0.74 20 1.89 9.1 243 112 27.1 0.71 20 1.84 9.0 236 109 30.3 0.78 19 1.90 9.2 245 113 26.8 0.59 17 1.83 8.9 233 108 29.1 0.61 16 1.87 9.1 240 111 30.0 0.64 16 1.89 9.1 243 112 31.8 0.56 16 1.95 9.4 257 122 29.4 0.54 17 1.90 9.2 249 119 32.8 0.59 16 1.96 9.4 259 124 29.4 0.41 13 1.88 9.1 246 118 31.9 0.42 12 1.93 9.3 254 121 32.8 0.44 12 1.94 9.4 256 122 34.1 0.36 11 2.01 9.6 268 130 31.5 0.35 12 1.96 9.4 260 126 35.2 0.38 11 2.02 9.7 270 132 - - - 27.9 0.86 22 1.99 9.5 253 111 25.7 0.83 22 1.94 9.3 246 108 28.7 0.90 21 2.00 9.6 256 112 25.3 0.73 19 1.92 9.3 243 107 27.4 0.76 19 1.97 9.5 251 110 28.2 0.79 18 1.99 9.5 253 111 28.7 0.77 20 2.03 9.7 273 118 26.5 0.74 21 1.98 9.5 264 115 29.6 0.81 19 2.05 9.8 275 120 26.2 0.61 17 1.97 9.4 262 114 28.4 0.63 16 2.01 9.6 270 117 29.3 0.66 16 2.03 9.7 273 118 31.1 0.58 17 2.10 10.0 288 129 28.7 0.56 17 2.04 9.8 279 125 32.0 0.61 16 2.11 10.0 291 131 28.7 0.42 13 2.03 9.7 276 124 31.1 0.44 13 2.08 9.9 285 128 32.1 0.46 12 2.09 10.0 288 129 33.3 0.37 11 2.16 10.3 300 138 30.8 0.36 12 2.11 10.0 291 134 34.3 0.39 11 2.18 10.3 303 139 - - - 27.2 0.88 22 2.11 10.2 288 116 25.1 0.85 22 2.06 10.0 279 112 28.0 0.92 21 2.13 10.3 291 117 24.7 0.75 19 2.04 9.9 277 111 26.8 0.78 19 2.09 10.1 285 115 27.6 0.81 18 2.11 10.2 288 116 28.0 0.79 20 2.16 10.4 310 123 25.9 0.76 21 2.11 10.2 301 119 28.9 0.83 19 2.18 10.5 313 124 25.6 0.62 17 2.09 10.1 298 118 27.7 0.65 17 2.14 10.3 307 122 28.6 0.68 16 2.16 10.4 310 123 30.3 0.60 17 2.23 10.7 327 134 28.0 0.58 17 2.17 10.4 318 130 31.2 0.63 16 2.25 10.7 331 136 28.0 0.43 13 2.15 10.3 314 129 30.4 0.45 13 2.21 10.6 324 133 31.3 0.47 12 2.23 10.7 327 134 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 28.1 0.73 19 1.83 8.9 223 104 MBh S/T Delta T KW AMPS HI PR LO PR 1125 28.9 0.76 18 1.85 9.0 226 105 MBh S/T Delta T KW AMPS HI PR LO PR 32.6 0.38 11 2.30 11.0 341 143 30.0 0.37 12 2.24 10.7 331 139 33.5 0.40 11 2.32 11.1 345 145 - - - 26.6 0.91 22 2.22 10.7 328 122 24.5 0.88 23 2.17 10.5 318 118 27.3 0.95 21 2.24 10.8 331 123 24.1 0.77 20 2.15 10.4 315 117 26.1 0.80 19 2.20 10.7 325 120 26.9 0.84 18 2.22 10.7 328 122 27.3 0.81 20 2.27 11.0 353 129 25.2 0.78 21 2.21 10.7 343 125 28.2 0.85 20 2.29 11.0 357 131 25.0 0.64 17 2.20 10.6 339 124 27.1 0.67 17 2.25 10.9 350 128 27.9 0.70 16 2.27 11.0 353 129 29.6 0.62 17 2.34 11.2 373 141 27.3 0.59 17 2.29 11.0 362 137 30.5 0.65 16 2.36 11.3 377 143 27.4 0.45 13 2.27 10.9 358 136 29.6 0.46 13 2.32 11.2 369 140 30.5 0.49 12 2.34 11.2 373 141 25.2 0.94 22 2.31 11.3 369 127 23.3 0.91 22 2.26 11.0 358 124 26.0 0.99 21 2.33 11.4 373 129 22.9 0.80 19 2.24 11.0 354 122 24.8 0.83 19 2.30 11.2 365 126 25.5 0.87 18 2.31 11.3 369 127 26.0 0.84 20 2.37 11.5 397 136 24.0 0.81 21 2.31 11.3 385 132 26.7 0.89 19 2.39 11.6 401 137 23.7 0.67 17 2.29 11.2 381 130 25.7 0.69 16 2.35 11.4 393 134 26.5 0.73 16 2.37 11.5 397 136 28.1 0.64 17 2.44 11.8 419 148 25.9 0.62 17 2.38 11.6 407 144 29.0 0.67 16 2.46 11.9 424 149 26.0 0.46 13 2.36 11.5 403 142 28.2 0.48 12 2.42 11.8 415 147 29.0 0.50 12 2.44 11.8 419 148 30.2 0.41 11 2.53 12.2 438 158 27.8 0.40 12 2.46 11.9 424 153 31.1 0.43 11 2.55 12.3 442 159 - - - 71 59 23.4 0.95 20 2.39 11.8 408 132 21.6 0.92 21 2.34 11.6 396 128 24.1 1.00 20 2.41 11.9 412 133 21.2 0.81 18 2.32 11.5 392 127 23.0 0.84 18 2.37 11.8 404 130 23.7 0.88 17 2.39 11.8 408 132 63 24.1 0.85 19 2.45 12.1 439 140 22.2 0.82 19 2.39 11.8 426 136 24.8 0.89 18 2.47 12.2 443 142 22.0 0.67 16 2.37 11.7 421 135 23.8 0.70 15 2.43 12.0 434 139 24.5 0.73 15 2.45 12.1 439 140 67 26.0 0.64 15 2.53 12.4 463 153 24.0 0.62 16 2.47 12.1 450 148 26.8 0.68 15 2.55 12.5 468 155 24.1 0.47 12 2.44 12.0 445 147 26.1 0.48 12 2.51 12.3 459 152 26.9 0.51 11 2.53 12.4 463 153 115 27.9 0.41 11 2.61 12.8 483 163 25.8 0.40 11 2.55 12.5 469 158 28.8 0.43 10 2.64 12.9 488 165 - - - 71 COOLING OPERATION KW = Total system power AMPS: Unit amps (com p.+ evaporator + condenser fan motors) 31.8 0.40 12 2.42 11.6 389 150 29.3 0.38 12 2.36 11.3 377 146 32.7 0.42 11 2.44 11.7 393 152 - - - Design Subcooling, 7 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 IDB* Airflow MODEL: *PG153009041A* COOLING PERFORMANCE DATA *PG1530***41A* 17 18 MODEL: *PG153009041A* EXPANDED PERFORMANCE DATA 26.8 0.88 25 1.82 8.9 221 103 30.4 1.00 25 1.89 9.2 233 109 29.6 0.95 26 1.88 9.1 230 108 27.3 0.92 26 1.83 8.9 223 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1000 875 1125 1000 875 27.8 0.89 26 1.87 9.1 240 111 30.1 0.92 25 1.92 9.3 248 114 31.0 0.96 24 1.93 9.3 250 116 27.4 0.82 24 1.86 9.0 238 110 29.7 0.85 23 1.90 9.2 245 113 29.1 0.80 24 1.93 9.3 254 121 31.6 0.83 24 1.98 9.5 262 125 32.5 0.87 23 1.99 9.6 264 126 29.3 0.67 21 1.91 9.2 251 120 31.7 0.69 20 1.96 9.4 259 124 31.1 0.65 21 1.99 9.6 265 129 33.7 0.67 21 2.04 9.8 273 133 34.7 0.71 20 2.06 9.9 276 134 31.3 0.50 16 1.97 9.5 262 128 33.9 0.52 16 2.02 9.7 270 132 26.6 0.95 27 1.97 9.5 251 110 28.9 0.99 26 2.02 9.7 258 114 29.7 1.00 24 2.04 9.7 261 115 26.2 0.91 25 1.96 9.4 248 109 28.4 0.94 25 2.00 9.6 256 113 27.2 0.92 26 2.01 9.6 270 117 29.4 0.95 26 2.06 9.9 278 121 30.3 1.00 25 2.08 9.9 281 122 26.8 0.85 24 2.00 9.6 267 116 29.0 0.88 24 2.05 9.8 275 120 28.4 0.83 25 2.08 9.9 285 128 30.8 0.86 24 2.13 10.1 294 132 31.7 0.90 23 2.15 10.2 297 133 28.6 0.69 21 2.06 9.8 282 127 31.0 0.72 20 2.11 10.0 291 131 30.3 0.67 21 2.14 10.2 297 136 32.9 0.70 21 2.20 10.4 306 141 33.9 0.73 20 2.22 10.5 309 142 30.6 0.52 17 2.13 10.1 294 135 33.1 0.54 16 2.18 10.3 303 139 26.0 0.98 27 2.09 10.1 285 115 28.2 1.00 26 2.15 10.3 294 118 29.0 1.00 24 2.16 10.4 297 119 25.6 0.93 25 2.08 10.0 282 113 27.7 0.97 25 2.13 10.3 291 117 26.5 0.94 26 2.14 10.3 307 122 28.7 0.98 26 2.19 10.5 316 126 29.6 1.00 24 2.21 10.6 319 127 26.1 0.87 24 2.12 10.2 304 121 NOTE: 28.3 0.91 24 2.18 10.5 313 124 32.3 0.55 16 2.32 11.1 345 145 27.0 1.00 25 2.24 10.8 331 123 27.6 0.94 24 2.29 11.0 357 131 29.5 0.76 21 2.36 11.3 377 143 31.5 0.57 16 2.44 11.7 393 152 27.8 0.85 25 2.21 10.6 324 133 30.1 0.88 24 2.26 10.8 334 137 31.0 0.92 23 2.28 10.9 337 139 29.6 0.69 21 2.28 10.9 338 142 32.1 0.72 21 2.34 11.1 348 146 33.1 0.75 20 2.36 11.2 352 148 25.4 1.00 27 2.20 10.7 325 120 27.5 1.00 25 2.26 10.9 335 124 28.3 1.00 23 2.28 11.0 338 125 25.9 0.97 26 2.25 10.9 349 128 28.0 1.00 26 2.31 11.1 360 132 28.9 1.00 24 2.33 11.2 364 133 27.1 0.88 25 2.32 11.2 369 140 29.4 0.91 25 2.38 11.4 380 144 30.2 0.95 24 2.40 11.5 384 146 24.1 1.00 25 2.29 11.2 365 126 26.1 1.00 24 2.35 11.5 377 130 26.9 1.00 22 2.37 11.6 380 131 23.7 1.00 25 2.28 11.1 362 125 25.7 1.00 24 2.33 11.4 373 129 24.6 1.00 26 2.35 11.4 393 134 26.6 1.00 24 2.41 11.7 405 138 27.4 1.00 22 2.43 11.8 409 140 24.2 0.94 24 2.33 11.3 389 133 26.2 0.97 23 2.39 11.6 401 137 25.7 0.91 25 2.42 11.7 415 146 27.9 0.95 24 2.48 12.0 428 151 28.7 0.99 23 2.51 12.1 432 153 25.9 0.76 21 2.40 11.7 411 145 28.0 0.79 20 2.46 11.9 424 149 27.5 0.74 21 2.50 12.1 433 156 29.7 0.77 21 2.57 12.4 446 161 30.6 0.80 20 2.59 12.5 451 162 27.7 0.57 17 2.48 12.0 429 154 30.0 0.59 16 2.55 12.3 442 159 71 30.9 0.62 16 2.57 12.4 446 161 22.3 1.00 23 2.37 11.8 404 130 24.2 1.00 22 2.44 12.0 416 134 24.9 1.00 20 2.46 12.1 420 136 21.9 1.01 23 2.35 11.7 400 129 23.8 1.00 22 2.42 11.9 412 133 59 24.5 1.00 20 2.44 12.0 416 134 22.8 1.00 24 2.43 12.0 434 139 24.7 1.00 23 2.49 12.3 448 143 25.4 1.00 21 2.51 12.4 452 144 22.4 0.94 22 2.41 11.9 430 137 24.3 0.98 22 2.47 12.2 443 142 63 25.0 1.00 20 2.49 12.3 448 143 23.8 0.92 23 2.51 12.3 459 151 25.8 0.95 23 2.57 12.6 473 156 26.6 1.00 22 2.59 12.7 478 158 24.0 0.77 19 2.49 12.2 454 150 26.0 0.80 19 2.55 12.5 468 155 67 26.7 0.84 18 2.57 12.6 473 156 115 25.4 0.75 20 2.59 12.7 478 161 27.6 0.77 20 2.66 13.0 493 166 28.4 0.81 19 2.68 13.1 498 168 25.6 0.57 15 2.57 12.6 474 160 27.8 0.60 15 2.64 12.9 488 165 71 28.6 0.62 15 2.66 13.0 493 166 COOLING OPERATION KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 28.9 0.71 22 2.40 11.5 385 149 31.3 0.74 21 2.46 11.8 397 153 32.3 0.77 20 2.48 11.9 401 155 27.9 29.8 24.9 25.5 27.2 29.1 0.71 0.53 0.96 0.90 0.73 0.55 21 17 25 24 21 17 2.19 2.26 2.18 2.23 2.31 2.38 10.5 10.8 10.6 10.8 11.1 11.4 321 335 322 346 365 381 132 140 119 127 138 147 Shaded area reflects AHRI rating conditions 30.2 0.74 21 2.25 10.7 331 136 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 29.0 0.91 24 1.86 9.0 228 106 MBh S/T Delta T KW AMPS HI PR LO PR Design Subcooling, 7 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 MBh 29.9 30.6 32.7 34.9 29.2 29.9 31.9 34.1 28.5 29.2 31.1 33.3 27.8 28.4 30.4 32.5 26.4 27.0 28.9 S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 Delta T 23 22 19 16 24 23 20 16 23 23 20 16 23 23 20 16 22 22 20 1125 KW 1.88 1.92 1.98 2.04 2.02 2.06 2.13 2.20 2.15 2.19 2.26 2.34 2.26 2.31 2.38 2.46 2.35 2.41 2.48 AMPS 9.1 9.3 9.5 9.8 9.7 9.9 10.1 10.4 10.3 10.5 10.8 11.1 10.9 11.1 11.4 11.8 11.5 11.7 12.0 HI PR 230 248 262 273 258 278 294 306 294 316 334 348 335 360 380 397 377 405 428 LO PR 108 114 125 133 114 121 132 141 118 126 137 146 124 132 144 153 130 138 151 COOLING PERFORMANCE DATA *PG1530***41A* MODEL: *PG1536***41A* EXPANDED PERFORMANCE DATA 24.1 0.61 17 1.62 7.3 240 116 22.2 0.59 17 1.58 7.1 233 113 25.0 0.78 20 1.64 7.4 245 119 24.3 0.74 21 1.63 7.3 242 118 MBh 23.2 S/T 0.73 Delta T 19 KW 1.58 AMPS 7.1 HI PR 223 LO PR 109 MBh 21.4 S/T 0.70 Delta T 20 KW 1.55 AMPS 7.0 HI PR 216 LO PR 106 MBh 24.3 S/T 0.87 Delta T 22 KW 1.61 AMPS 7.2 HI PR 227 LO PR 112 MBh 23.6 S/T 0.83 Delta T 22 KW 1.60 AMPS 7.2 HI PR 225 LO PR 111 800 700 900 26.3 0.56 17 1.68 7.5 256 128 27.1 0.59 16 1.69 7.6 258 130 24.3 0.41 13 1.63 7.3 246 123 26.4 0.42 13 1.66 7.5 253 127 67 27.2 0.44 12 1.68 7.5 256 128 28.2 0.36 12 1.73 7.8 267 137 29.1 0.38 11 1.74 7.8 270 138 - - 71 - 23.1 0.86 23 1.71 7.7 253 117 23.7 0.90 22 1.73 7.7 255 118 20.9 0.73 20 1.66 7.4 243 112 22.7 0.75 20 1.70 7.6 250 116 59 23.4 0.79 19 1.71 7.7 253 117 23.7 0.77 21 1.75 7.8 272 124 24.5 0.80 20 1.76 7.9 275 126 21.7 0.61 17 1.70 7.6 261 119 23.5 0.63 17 1.74 7.8 269 123 63 24.2 0.66 16 1.75 7.8 272 124 25.7 0.58 17 1.80 8.1 287 136 26.5 0.61 16 1.82 8.1 290 137 23.8 0.42 13 1.75 7.8 276 130 25.7 0.44 13 1.79 8.0 284 134 67 26.5 0.46 12 1.80 8.1 287 136 27.6 0.37 12 1.86 8.3 299 145 28.4 0.39 11 1.88 8.4 302 146 - - 71 - 22.5 0.88 23 1.82 8.2 287 121 23.2 0.92 22 1.83 8.3 290 123 20.4 0.75 20 1.76 8.0 276 117 22.1 0.77 20 1.80 8.2 284 120 59 22.8 0.81 19 1.82 8.2 287 121 23.2 0.79 21 1.86 8.4 309 129 23.9 0.82 20 1.87 8.5 312 130 21.2 0.62 17 1.80 8.1 297 124 22.9 0.65 17 1.84 8.3 306 128 25.1 0.60 17 1.92 8.7 326 141 25.8 0.62 16 1.93 8.7 330 142 23.2 0.43 13 1.86 8.4 314 135 25.1 0.45 13 1.90 8.6 323 140 24.8 0.37 12 1.93 8.7 330 146 26.9 0.38 12 1.98 8.9 341 150 27.7 0.40 11 2.00 9.0 344 152 - - 20.3 0.88 23 1.87 8.5 317 124 22.0 0.91 23 1.91 8.7 327 128 22.6 0.95 22 1.93 8.8 331 129 19.9 0.77 20 1.85 8.4 314 122 21.6 0.80 20 1.90 8.7 324 126 23.3 0.85 20 1.97 9.0 356 137 22.6 0.81 21 1.95 8.9 352 136 20.9 0.78 21 1.91 8.7 342 132 20.7 0.64 17 1.89 8.6 338 130 22.4 0.67 17 1.94 8.8 349 134 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 23.6 25.9 22.2 23.1 0.68 0.47 0.84 0.70 16 12 19 16 1.86 1.92 1.91 1.95 8.4 8.7 8.7 8.9 309 326 327 352 129 141 128 136 MBh 21.8 22.4 24.3 26.1 21.3 21.9 23.7 25.5 20.8 21.4 23.2 S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 Delta T 23 21 17 12 23 21 17 12 23 21 17 700 KW 1.56 1.59 1.64 1.69 1.67 1.71 1.76 1.82 1.78 1.81 1.87 AMPS 7.0 7.2 7.4 7.6 7.5 7.7 7.9 8.1 8.0 8.2 8.4 HI PR 218 235 248 259 245 264 278 290 279 300 317 LO PR 107 114 125 133 113 121 132 140 118 125 137 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 800 900 63 24.8 0.64 16 1.63 7.3 242 118 59 MBh 23.9 S/T 0.76 Delta T 19 KW 1.59 AMPS 7.2 HI PR 225 LO PR 111 Airflow 75 22.6 0.59 18 1.97 8.9 361 144 24.5 0.61 17 2.02 9.2 372 148 25.2 0.64 17 2.03 9.2 376 150 22.6 0.45 13 1.95 8.9 357 142 24.5 0.46 13 2.00 9.1 368 147 67 25.3 0.48 13 2.02 9.2 372 148 20.9 0.94 23 1.99 9.2 368 134 21.5 0.99 22 2.01 9.3 372 135 18.9 0.80 20 1.93 8.9 353 128 20.5 0.83 20 1.97 9.1 364 132 59 21.1 0.87 19 1.99 9.2 368 134 21.5 0.84 21 2.03 9.4 396 142 22.1 0.88 20 2.05 9.5 400 144 19.6 0.67 17 1.97 9.1 380 137 21.3 0.69 17 2.02 9.3 392 141 63 21.9 0.73 16 2.03 9.4 396 142 23.2 0.64 17 2.10 9.7 418 155 23.9 0.67 16 2.12 9.8 423 157 21.5 0.46 13 2.03 9.4 402 149 23.3 0.48 13 2.08 9.6 414 154 67 24.0 0.50 12 2.10 9.7 418 155 25.0 0.41 12 2.17 10.0 436 165 25.7 0.43 11 2.19 10.1 441 167 - - 71 - 19.3 0.95 21 2.06 9.7 407 138 19.9 1.00 20 2.08 9.8 411 140 17.5 0.81 19 1.99 9.4 391 133 19.0 0.84 18 2.04 9.6 403 137 59 19.6 0.88 18 2.06 9.7 407 138 19.9 0.85 19 2.10 9.9 438 147 20.5 0.89 19 2.12 10.0 442 149 18.2 0.67 16 2.04 9.6 420 141 19.7 0.70 16 2.09 9.8 433 146 63 20.3 0.73 15 2.10 9.9 438 147 21.5 0.64 16 2.17 10.2 462 161 22.2 0.67 15 2.19 10.3 467 162 19.9 0.47 12 2.10 9.9 444 154 21.6 0.48 12 2.15 10.1 458 159 67 22.2 0.51 12 2.17 10.2 462 161 23.1 0.41 11 2.25 10.5 482 171 23.8 0.43 11 2.26 10.6 487 173 - - 71 - 24.2 19.3 19.8 21.5 23.0 17.8 18.4 19.9 21.3 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40 12 23 21 17 12 21 20 16 11 2.03 1.94 1.98 2.05 2.12 2.01 2.05 2.12 2.19 9.2 9.0 9.2 9.4 9.8 9.5 9.7 9.9 10.3 376 357 384 406 423 395 425 448 468 153 130 138 151 160 134 143 156 166 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 26.3 0.40 12 2.08 9.5 388 158 27.1 0.41 11 2.10 9.5 392 159 - - 71 - 105 1ST STAGE 75 70 IDB* 65 115 COOLING OPERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. COOLING PERFORMANCE DATA *PG1536***41A* 19 20 MODEL: *PG1536***41A* EXPANDED PERFORMANCE DATA 25.7 0.96 25 1.67 7.5 250 121 24.9 0.92 26 1.65 7.4 247 120 23.0 0.89 27 1.61 7.3 240 116 MBh 25.2 S/T 1.00 Delta T 26 KW 1.63 AMPS 7.4 HI PR 232 LO PR 114 MBh 24.4 S/T 0.95 Delta T 27 KW 1.62 AMPS 7.3 HI PR 230 LO PR 113 MBh 22.6 S/T 0.92 Delta T 27 KW 1.58 AMPS 7.1 HI PR 223 LO PR 109 700 900 800 700 24.1 0.80 25 1.66 7.5 253 127 26.1 0.83 25 1.70 7.7 261 131 26.9 0.87 24 1.72 7.7 264 132 24.2 0.67 21 1.65 7.4 251 126 25.7 0.65 22 1.72 7.7 264 135 27.8 0.67 22 1.76 7.9 272 140 28.7 0.70 21 1.77 8.0 275 141 25.9 0.50 17 1.70 7.7 261 134 28.0 0.52 17 1.74 7.8 270 138 22.0 0.95 28 1.70 7.6 250 116 23.9 0.99 27 1.74 7.8 258 119 24.6 1.00 25 1.76 7.9 260 120 21.7 0.91 26 1.69 7.6 248 114 23.5 0.94 25 1.73 7.7 255 118 22.5 0.92 27 1.74 7.8 269 123 24.3 0.95 27 1.78 8.0 277 127 25.1 1.00 26 1.79 8.0 280 128 22.1 0.85 25 1.72 7.7 266 122 24.0 0.88 24 1.76 7.9 275 126 23.5 0.83 26 1.79 8.0 284 134 25.5 0.86 25 1.83 8.2 293 138 26.3 0.90 24 1.85 8.2 296 140 23.6 0.69 22 1.78 7.9 281 133 25.6 0.72 21 1.82 8.1 290 137 25.1 0.67 22 1.85 8.2 296 143 27.2 0.70 22 1.89 8.4 305 147 28.0 0.73 21 1.91 8.5 309 149 25.3 0.52 17 1.83 8.2 293 142 27.4 0.54 17 1.88 8.4 302 146 21.5 0.98 28 1.80 8.2 284 120 23.3 1.00 27 1.85 8.4 293 124 24.0 1.00 25 1.86 8.4 296 125 21.1 0.93 26 1.79 8.1 282 119 22.9 0.96 25 1.83 8.3 290 123 21.9 0.94 27 1.84 8.3 306 128 23.8 0.98 27 1.89 8.5 315 132 24.5 1.00 25 1.90 8.6 319 133 21.6 0.87 25 1.83 8.3 303 127 23.4 0.90 24 1.87 8.5 312 130 23.0 0.85 26 1.90 8.6 323 140 24.9 0.88 25 1.95 8.8 333 144 25.6 0.92 24 1.96 8.9 336 145 23.1 0.71 22 1.89 8.5 320 138 25.0 0.74 21 1.93 8.7 330 142 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 22.7 0.82 24 1.60 7.2 237 115 MBh 22.2 S/T 0.88 Delta T 25 KW 1.57 AMPS 7.1 HI PR 221 LO PR 108 800 26.2 0.69 21 1.69 7.6 258 130 24.5 0.69 22 1.96 8.9 337 149 26.5 0.71 22 2.01 9.1 347 153 27.3 0.75 21 2.03 9.2 351 155 24.7 0.53 17 1.95 8.8 334 147 26.7 0.55 17 2.00 9.0 344 152 21.0 1.00 28 1.90 8.7 324 126 22.7 1.00 26 1.94 8.9 334 130 23.4 1.00 24 1.96 8.9 337 131 20.6 0.96 26 1.88 8.6 321 125 22.4 1.00 26 1.93 8.8 331 129 21.4 0.97 27 1.94 8.8 348 134 23.2 1.00 27 1.99 9.1 359 138 23.9 1.00 24 2.00 9.1 363 140 21.1 0.90 25 1.92 8.8 345 133 22.8 0.93 25 1.97 9.0 356 137 22.4 0.88 26 2.00 9.1 368 147 24.3 0.91 25 2.05 9.3 379 151 25.0 0.95 24 2.07 9.4 383 153 22.5 0.73 22 1.98 9.0 364 145 24.4 0.76 21 2.03 9.2 376 150 19.9 1.00 26 1.97 9.1 364 132 21.6 1.00 25 2.02 9.4 376 136 22.3 1.00 23 2.04 9.4 379 138 19.6 1.00 26 1.96 9.1 361 131 21.2 1.00 24 2.01 9.3 372 135 20.3 1.00 27 2.02 9.3 392 141 22.0 1.00 25 2.07 9.6 404 145 22.7 1.00 23 2.09 9.6 408 147 20.0 0.93 25 2.00 9.3 388 139 21.7 0.97 24 2.05 9.5 400 144 21.3 0.91 25 2.08 9.6 414 154 23.1 0.94 25 2.14 9.8 427 158 23.8 0.99 24 2.15 9.9 431 160 21.4 0.76 21 2.07 9.5 410 152 23.2 0.79 21 2.12 9.8 423 157 22.7 0.74 22 2.15 9.9 432 164 24.6 0.77 22 2.21 10.2 445 169 25.3 0.80 21 2.22 10.3 450 170 22.9 0.57 17 2.13 9.8 428 162 24.8 0.59 17 2.19 10.1 441 167 18.5 1.00 24 2.04 9.6 403 137 20.0 1.00 23 2.09 9.9 415 141 20.6 1.00 21 2.11 9.9 419 142 18.2 1.00 24 2.03 9.5 399 135 19.7 1.00 23 2.08 9.8 411 140 18.8 1.00 25 2.09 9.8 433 146 20.4 1.00 23 2.14 10.1 447 150 21.0 1.00 21 2.16 10.1 451 152 18.6 0.94 23 2.07 9.7 429 144 20.1 0.98 23 2.12 10.0 442 149 19.7 0.92 24 2.15 10.1 457 159 21.4 0.95 23 2.21 10.4 472 164 22.0 1.00 22 2.23 10.5 476 165 19.8 0.77 20 2.14 10.0 453 157 21.5 0.80 20 2.19 10.3 467 162 67 22.1 0.83 19 2.21 10.4 472 164 21.0 0.74 21 2.23 10.5 477 169 22.8 0.77 20 2.28 10.7 492 174 23.5 0.81 19 2.30 10.8 497 176 21.2 0.57 16 2.21 10.4 472 168 23.0 0.59 16 2.26 10.6 487 173 71 23.6 0.62 15 2.28 10.7 492 174 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 23.9 0.71 22 2.06 9.4 384 156 25.9 0.74 22 2.12 9.6 396 161 26.7 0.77 21 2.13 9.7 400 163 24.1 0.55 17 2.05 9.3 380 155 26.1 0.57 17 2.10 9.5 392 159 63 20.7 1.00 21 2.14 10.1 447 150 1ST STAGE 85 80 24.6 0.85 24 1.64 7.4 245 119 MBh 24.0 S/T 0.91 Delta T 25 KW 1.61 AMPS 7.2 HI PR 227 LO PR 112 59 20.3 1.00 21 2.09 9.9 415 141 115 COOLING OPERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 24.7 25.3 27.0 28.9 24.2 24.7 26.4 28.2 23.6 24.1 25.8 27.5 23.0 23.5 25.1 26.9 21.9 22.3 23.9 25.5 S/T 0.95 0.89 0.73 0.54 1.00 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.83 0.62 Delta T 24 23 20 16 25 23 20 16 24 23 20 16 24 24 20 16 22 23 20 16 900 KW 1.62 1.65 1.70 1.76 1.74 1.78 1.83 1.89 1.85 1.89 1.95 2.01 1.94 1.99 2.05 2.12 2.02 2.07 2.14 2.21 AMPS 7.3 7.4 7.7 7.9 7.8 8.0 8.2 8.4 8.4 8.5 8.8 9.1 8.9 9.1 9.3 9.6 9.4 9.6 9.8 10.2 HI PR 230 247 261 272 258 277 293 305 293 315 333 347 334 359 379 396 376 404 427 445 LO PR 113 120 131 140 119 127 138 147 124 132 144 153 130 138 151 161 136 145 158 169 COOLING PERFORMANCE DATA *PG1536***41A* MODEL: *PG1536***41A* EXPANDED PERFORMANCE DATA 35.3 0.88 21 2.54 12.7 254 111 34.2 0.84 22 2.52 12.7 252 110 31.6 0.81 22 2.46 12.4 244 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1072 1378 1225 1072 32.5 0.72 20 2.52 12.6 263 114 35.3 0.75 20 2.58 12.9 271 117 36.3 0.79 19 2.60 13.0 274 118 32.2 0.59 16 2.50 12.5 260 112 35.2 0.55 17 2.59 12.9 278 124 38.2 0.57 16 2.65 13.2 286 128 39.3 0.60 16 2.68 13.3 289 129 35.3 0.41 12 2.57 12.8 275 123 38.2 0.43 12 2.63 13.1 283 127 37.8 0.35 11 2.67 13.3 289 132 41.0 0.37 11 2.74 13.6 298 136 42.2 0.38 11 2.76 13.7 301 137 - - 30.9 0.84 22 2.65 13.2 274 113 33.5 0.87 22 2.71 13.4 283 116 34.5 0.91 21 2.73 13.5 285 117 30.4 0.74 19 2.63 13.1 271 112 32.9 0.76 19 2.69 13.3 280 115 31.8 0.75 20 2.70 13.4 295 120 34.4 0.78 20 2.77 13.7 304 124 35.5 0.81 19 2.79 13.8 307 125 31.5 0.62 17 2.68 13.3 292 119 34.1 0.64 16 2.75 13.6 301 122 34.4 0.57 17 2.79 13.7 311 131 37.3 0.59 16 2.86 14.0 321 135 38.4 0.62 16 2.88 14.1 324 136 34.5 0.43 13 2.77 13.6 308 130 37.4 0.44 12 2.83 13.9 318 134 36.9 0.36 12 2.88 14.1 325 140 40.0 0.38 11 2.95 14.4 335 144 41.2 0.40 11 2.97 14.5 338 145 - - 30.1 0.86 22 2.81 14.0 312 117 32.7 0.89 22 2.88 14.3 321 121 33.6 0.93 21 2.90 14.4 325 122 29.6 0.76 19 2.79 13.9 309 116 32.1 0.78 19 2.86 14.2 318 120 31.0 0.77 20 2.87 14.3 335 125 33.6 0.80 20 2.94 14.6 346 129 34.6 0.84 19 2.97 14.7 349 130 30.7 0.63 17 2.85 14.2 332 123 33.3 0.65 16 2.92 14.5 342 127 33.6 0.58 17 2.96 14.6 354 136 36.4 0.60 16 3.04 15.0 365 140 37.5 0.63 16 3.06 15.1 369 142 33.7 0.44 13 2.94 14.5 351 135 36.5 0.45 12 3.01 14.9 361 139 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 31.1 0.71 19 2.45 12.3 242 106 MBh S/T Delta T KW AMPS HI PR LO PR 1225 34.9 0.62 16 2.56 12.8 268 116 36.1 0.37 12 3.06 15.1 369 145 39.1 0.39 11 3.13 15.4 381 149 40.2 0.41 11 3.16 15.5 385 151 - - 29.4 0.89 22 2.95 14.8 355 123 31.9 0.92 22 3.03 15.1 366 127 32.8 0.96 21 3.05 15.2 370 128 28.9 0.78 19 2.93 14.6 351 122 31.3 0.81 19 3.00 15.0 362 126 30.3 0.79 21 3.02 15.0 382 131 32.8 0.60 17 3.11 15.4 403 143 35.5 0.62 17 3.19 15.8 416 147 36.6 0.65 16 3.22 15.9 420 149 33.8 0.86 19 3.12 15.5 398 136 32.8 0.82 20 3.09 15.4 394 135 32.8 0.45 13 3.09 15.3 399 142 35.6 0.47 12 3.17 15.7 412 146 30.0 0.65 17 2.99 14.9 378 130 32.5 0.68 16 3.07 15.3 390 134 27.9 0.92 22 3.08 15.5 399 129 30.3 0.95 22 3.15 15.8 412 133 31.2 1.00 21 3.18 16.0 416 134 27.5 0.81 19 3.05 15.4 395 128 29.8 0.84 19 3.13 15.7 408 132 28.8 0.82 20 3.14 15.8 430 137 31.2 0.85 20 3.22 16.2 443 142 32.1 0.90 19 3.25 16.3 447 143 28.5 0.68 17 3.12 15.7 425 136 30.8 0.70 16 3.19 16.0 439 140 31.1 0.62 17 3.24 16.2 454 150 33.7 0.65 16 3.33 16.6 468 155 34.7 0.68 16 3.35 16.7 473 156 31.2 0.47 13 3.22 16.1 449 148 33.8 0.49 12 3.30 16.5 463 153 33.4 0.40 11 3.35 16.7 473 160 36.2 0.42 11 3.44 17.1 488 165 37.3 0.44 11 3.47 17.2 493 166 - - 25.9 0.93 21 3.18 16.2 441 133 28.0 0.96 20 3.26 16.6 455 138 28.9 1.00 19 3.29 16.7 459 139 25.4 0.82 18 3.15 16.1 437 132 27.6 0.85 18 3.23 16.5 450 136 26.6 0.83 19 3.25 16.6 475 142 28.9 0.86 19 3.33 16.9 490 146 29.7 0.90 18 3.36 17.1 494 148 26.4 0.68 15 3.22 16.4 470 141 28.6 0.71 15 3.30 16.8 485 145 28.8 0.63 16 3.36 17.0 501 155 31.2 0.65 15 3.44 17.4 517 160 32.2 0.68 15 3.47 17.5 522 161 28.9 0.47 12 3.33 16.9 496 153 31.3 0.49 12 3.41 17.3 512 158 67 32.2 0.51 11 3.44 17.4 517 160 31.0 0.40 11 3.47 17.5 523 165 33.5 0.42 11 3.56 17.9 539 170 34.5 0.44 10 3.59 18.1 545 172 - - 71 - KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 35.2 0.39 12 3.22 15.9 421 152 38.1 0.40 11 3.30 16.3 434 157 39.3 0.42 11 3.32 16.4 438 159 - - 63 29.4 0.74 15 3.33 16.9 489 146 2ND STAGE 75 70 33.7 0.74 19 2.50 12.6 249 109 MBh S/T Delta T KW AMPS HI PR LO PR 59 28.4 0.89 17 3.26 16.6 455 138 115 COOLING OPERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 34.7 36.0 39.4 33.9 35.1 38.5 33.1 34.3 37.6 32.3 33.4 36.6 30.7 31.8 34.8 S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 Delta T 18 15 12 18 16 12 18 16 12 18 16 12 18 16 12 1378 KW 2.52 2.58 2.65 2.71 2.77 2.86 2.88 2.94 3.03 3.03 3.09 3.19 3.15 3.22 3.33 AMPS 12.7 12.9 13.2 13.4 13.7 14.0 14.3 14.6 15.0 15.1 15.4 15.8 15.8 16.2 16.6 HI PR 252 271 286 282 304 321 321 346 365 366 394 416 412 443 468 LO PR 110 117 128 116 124 135 121 129 140 127 135 147 133 142 154 - COOLING PERFORMANCE DATA *PG1536***41A* 21 22 MODEL: *PG1536***41A* EXPANDED PERFORMANCE DATA 36.5 1.00 24 2.58 12.9 259 113 35.5 0.96 26 2.56 12.8 257 112 32.7 0.93 26 2.50 12.6 249 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1072 1378 1225 1072 33.4 0.90 26 2.55 12.8 268 116 36.2 0.93 25 2.62 13.1 276 119 37.2 0.98 24 2.64 13.2 279 121 32.9 0.83 23 2.53 12.7 265 115 34.9 0.81 24 2.63 13.1 283 126 37.9 0.84 24 2.70 13.4 292 130 39.0 0.88 23 2.72 13.5 295 132 35.1 0.68 20 2.61 13.0 280 125 38.1 0.70 20 2.68 13.3 289 129 37.3 0.66 21 2.72 13.5 295 135 40.4 0.68 21 2.78 13.8 304 139 41.6 0.71 20 2.80 13.9 308 140 37.5 0.51 16 2.69 13.4 292 133 40.7 0.52 16 2.76 13.7 301 138 32.0 0.96 26 2.69 13.3 280 115 34.6 1.00 26 2.76 13.6 288 119 35.7 1.00 24 2.78 13.7 291 120 31.4 0.92 25 2.67 13.2 277 114 34.0 0.95 24 2.73 13.5 285 117 32.6 0.93 26 2.75 13.6 301 122 35.3 0.96 26 2.81 13.9 310 126 36.4 1.00 24 2.84 14.0 313 127 32.1 0.86 24 2.73 13.5 298 121 34.8 0.89 23 2.79 13.8 307 125 34.1 0.84 25 2.83 13.9 318 134 37.0 0.87 24 2.90 14.2 328 138 38.1 0.91 23 2.93 14.3 331 139 34.3 0.70 21 2.81 13.8 315 132 37.2 0.73 20 2.88 14.1 324 136 36.4 0.68 21 2.92 14.3 331 142 39.5 0.71 21 3.00 14.6 342 147 40.6 0.74 20 3.02 14.7 345 148 36.7 0.52 16 2.90 14.2 328 141 39.7 0.54 16 2.97 14.5 338 145 31.2 0.99 26 2.86 14.2 318 120 33.8 1.00 25 2.93 14.5 328 123 34.8 1.00 23 2.95 14.6 331 125 30.7 0.94 25 2.83 14.1 315 118 33.2 0.98 24 2.90 14.4 325 122 31.8 0.95 26 2.92 14.5 342 127 34.5 0.99 26 2.99 14.8 353 131 35.5 1.00 24 3.01 14.9 356 132 31.3 0.88 24 2.89 14.4 339 126 34.0 0.92 23 2.97 14.7 349 130 33.3 0.86 25 3.01 14.9 361 139 36.1 0.89 24 3.08 15.2 373 143 37.2 0.94 23 3.11 15.3 376 145 33.5 0.72 21 2.99 14.7 358 138 36.3 0.75 20 3.06 15.1 369 142 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 32.2 0.89 24 2.48 12.5 247 108 MBh S/T Delta T KW AMPS HI PR LO PR 1225 35.6 0.86 23 2.60 13.0 274 118 35.6 0.70 21 3.11 15.3 377 148 38.5 0.72 21 3.19 15.6 389 152 39.7 0.76 20 3.21 15.8 392 154 35.8 0.54 17 3.08 15.2 373 146 38.8 0.56 16 3.16 15.5 385 151 30.5 1.00 26 3.00 15.0 362 126 33.0 1.00 25 3.08 15.3 373 130 34.0 1.00 23 3.10 15.4 377 131 29.9 0.97 25 2.98 14.9 359 124 32.4 1.00 24 3.05 15.2 370 128 31.0 0.98 26 3.07 15.3 390 134 33.6 1.00 25 3.14 15.6 402 138 34.6 1.00 23 3.17 15.7 406 139 30.6 0.91 24 3.04 15.1 386 132 33.1 0.95 24 3.12 15.5 398 136 32.5 0.89 25 3.17 15.7 412 146 35.2 0.92 24 3.25 16.0 424 150 36.3 0.97 23 3.27 16.1 429 152 32.7 0.74 21 3.14 15.5 407 144 35.4 0.77 20 3.22 15.9 420 149 28.9 1.00 25 3.13 15.7 407 132 31.3 1.00 24 3.20 16.1 420 136 32.3 1.00 22 3.23 16.2 424 137 28.4 1.01 25 3.10 15.6 403 130 30.8 1.00 23 3.18 16.0 416 134 29.5 1.00 25 3.19 16.0 438 140 31.9 1.00 24 3.28 16.4 452 144 32.9 1.00 22 3.30 16.5 457 146 29.1 0.95 24 3.17 15.9 434 139 31.5 0.98 23 3.25 16.3 448 143 30.9 0.92 24 3.30 16.5 463 153 33.5 0.96 24 3.38 16.8 477 158 34.5 1.00 23 3.41 17.0 482 159 31.0 0.77 21 3.27 16.3 458 151 33.6 0.80 20 3.35 16.7 473 156 33.0 0.75 21 3.41 17.0 483 163 35.7 0.78 21 3.49 17.4 498 168 36.8 0.81 20 3.52 17.5 503 170 33.2 0.58 16 3.38 16.8 478 161 36.0 0.60 16 3.47 17.2 493 166 26.8 1.00 23 3.23 16.5 450 136 29.0 1.00 22 3.32 16.9 464 140 29.9 1.00 20 3.34 17.0 469 142 26.3 1.02 23 3.21 16.4 446 135 28.5 1.00 21 3.29 16.7 460 139 27.3 1.00 23 3.30 16.8 484 145 29.6 1.00 22 3.39 17.2 499 149 30.5 1.00 20 3.42 17.3 504 151 26.9 0.95 22 3.28 16.7 480 143 29.2 0.99 22 3.36 17.1 494 148 28.6 0.93 23 3.41 17.3 512 158 31.0 0.96 22 3.50 17.7 527 163 31.9 1.00 21 3.53 17.8 533 165 28.8 0.78 19 3.38 17.1 506 157 31.2 0.81 19 3.47 17.5 522 161 67 32.1 0.84 18 3.50 17.7 527 163 30.5 0.75 20 3.53 17.8 534 168 33.1 0.78 19 3.62 18.2 550 174 34.1 0.82 19 3.65 18.4 556 175 30.7 0.58 15 3.50 17.7 528 167 33.3 0.60 15 3.59 18.1 545 172 71 34.3 0.63 14 3.62 18.2 550 174 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 34.7 0.72 21 3.27 16.1 429 155 37.6 0.75 21 3.35 16.5 443 160 38.7 0.78 20 3.38 16.6 447 162 34.9 0.55 17 3.24 16.0 425 154 37.8 0.58 16 3.33 16.4 438 159 63 30.0 1.00 20 3.39 17.2 499 149 2ND STAGE 85 80 34.9 0.92 24 2.54 12.7 254 111 MBh S/T Delta T KW AMPS HI PR LO PR 59 29.4 1.00 20 3.32 16.9 464 140 115 COOLING OPERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 35.9 36.7 39.2 41.9 35.1 35.8 38.3 40.9 34.2 35.0 37.4 40.0 33.4 34.1 36.5 39.0 31.7 32.4 34.6 37.0 S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 Delta T 23 22 19 15 23 22 19 16 23 22 20 16 22 23 20 16 21 22 19 15 1378 KW 2.56 2.62 2.70 2.78 2.76 2.81 2.90 3.00 2.93 2.99 3.08 3.19 3.08 3.14 3.25 3.35 3.20 3.28 3.38 3.49 AMPS 12.8 13.1 13.4 13.8 13.6 13.9 14.2 14.6 14.5 14.8 15.2 15.6 15.3 15.6 16.0 16.5 16.1 16.4 16.8 17.4 HI PR 257 276 292 304 288 310 328 342 328 353 373 389 373 402 424 443 420 452 477 498 LO PR 112 119 130 139 119 126 138 147 123 131 143 152 130 138 150 160 136 144 158 168 COOLING PERFORMANCE DATA *PG1536***41A* EXPANDED PERFORMANCE DATA 31.4 0.67 22 2.23 10.7 228 101 35.0 0.80 23 2.31 11.0 238 106 34.6 0.79 24 2.30 11.0 237 105 32.0 0.76 26 2.24 10.8 230 102 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1055 875 1125 875 1055 35.7 0.71 22 2.35 11.2 255 112 32.9 0.68 24 2.29 11.0 247 109 36.0 0.72 21 2.36 11.3 256 112 32.6 0.56 19 2.27 10.9 245 107 35.3 0.58 18 2.33 11.2 253 111 35.7 0.59 17 2.34 11.2 253 111 38.6 0.53 18 2.43 11.5 269 122 35.6 0.51 19 2.37 11.3 261 119 39.0 0.54 17 2.43 11.6 270 123 35.7 0.39 15 2.35 11.2 259 117 38.7 0.40 14 2.41 11.5 267 121 39.1 0.41 13 2.41 11.5 267 121 41.4 0.34 12 2.51 11.9 281 130 38.2 0.33 13 2.44 11.6 273 126 41.8 0.35 12 2.51 11.9 282 131 - - - 33.8 0.82 24 2.48 11.8 266 111 31.2 0.79 26 2.42 11.5 258 108 34.2 0.83 23 2.49 11.8 267 111 30.7 0.69 22 2.40 11.4 255 107 33.3 0.72 21 2.46 11.7 263 110 33.6 0.73 20 2.47 11.7 264 110 34.8 0.73 22 2.54 12.0 286 118 32.2 0.71 24 2.47 11.7 278 115 35.2 0.75 21 2.54 12.0 287 119 31.8 0.58 19 2.45 11.6 275 114 34.5 0.60 18 2.51 11.9 283 117 34.8 0.61 17 2.52 11.9 284 117 37.7 0.55 18 2.62 12.3 302 129 34.8 0.53 20 2.55 12.0 293 125 38.1 0.56 18 2.63 12.4 303 129 34.9 0.40 15 2.53 11.9 290 124 37.8 0.42 14 2.60 12.2 299 128 38.2 0.42 13 2.60 12.3 300 128 40.5 0.36 13 2.71 12.7 315 137 37.3 0.34 13 2.64 12.4 306 133 40.9 0.36 12 2.71 12.7 316 138 - - - 33.0 0.84 24 2.64 12.6 303 116 30.5 0.81 26 2.57 12.3 293 112 33.4 0.85 23 2.65 12.6 303 116 30.0 0.71 22 2.55 12.2 290 111 32.5 0.74 21 2.62 12.5 299 114 32.8 0.75 20 2.63 12.5 300 115 34.0 0.75 22 2.70 12.9 326 123 31.4 0.72 24 2.63 12.6 316 119 34.3 0.76 21 2.71 12.9 327 123 31.1 0.59 19 2.61 12.5 313 118 33.7 0.62 18 2.68 12.8 322 122 34.0 0.63 17 2.68 12.8 323 122 36.8 0.57 18 2.79 13.2 344 134 34.0 0.55 20 2.72 12.9 333 130 37.2 0.58 18 2.80 13.3 345 135 34.0 0.41 15 2.70 12.8 330 129 36.9 0.43 14 2.77 13.1 340 133 37.2 0.44 13 2.77 13.2 341 133 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 34.1 0.69 21 2.28 10.9 235 104 MBh S/T Delta T KW AMPS HI PR LO PR 1125 34.4 0.71 20 2.29 11.0 235 104 MBh S/T Delta T KW AMPS HI PR LO PR 39.5 0.37 13 2.88 13.7 359 143 36.5 0.35 13 2.81 13.3 348 139 39.9 0.37 12 2.89 13.7 360 143 - - - 32.2 0.87 24 2.78 13.3 345 121 29.7 0.83 26 2.71 13.0 334 118 32.5 0.88 23 2.79 13.4 346 122 29.2 0.73 23 2.69 12.9 331 117 31.7 0.76 21 2.76 13.2 341 120 32.0 0.78 20 2.77 13.3 342 120 33.2 0.77 22 2.85 13.6 371 129 30.6 0.75 24 2.77 13.3 360 125 33.5 0.79 22 2.85 13.7 372 129 30.3 0.61 20 2.75 13.2 356 124 32.8 0.64 18 2.82 13.5 367 128 33.2 0.65 18 2.83 13.5 368 128 35.9 0.59 18 2.94 14.0 392 141 33.1 0.56 20 2.87 13.7 380 137 36.3 0.60 18 2.95 14.0 393 141 33.2 0.42 15 2.84 13.6 376 135 36.0 0.44 14 2.92 13.9 388 140 36.3 0.45 13 2.92 13.9 389 140 30.6 0.90 24 2.90 14.1 388 127 28.3 0.87 26 2.83 13.7 376 123 30.9 0.92 23 2.91 14.1 389 128 27.8 0.76 22 2.80 13.6 372 122 30.1 0.79 21 2.88 14.0 384 126 30.4 0.81 20 2.88 14.0 385 126 31.5 0.80 22 2.97 14.4 417 135 29.1 0.77 24 2.89 14.0 405 131 31.8 0.82 21 2.98 14.4 418 136 28.8 0.64 19 2.87 13.9 401 130 31.2 0.66 18 2.94 14.3 413 134 31.5 0.67 17 2.95 14.3 414 134 34.1 0.61 18 3.07 14.8 440 148 31.5 0.59 19 2.99 14.4 427 143 34.5 0.62 17 3.08 14.8 442 148 31.5 0.44 15 2.96 14.3 423 142 34.2 0.46 14 3.04 14.7 436 146 34.5 0.47 13 3.05 14.7 437 147 36.6 0.39 12 3.17 15.3 459 157 33.8 0.38 13 3.09 14.9 446 153 37.0 0.40 12 3.18 15.3 461 158 - - - 71 59 28.4 0.91 22 3.01 14.8 428 132 26.2 0.87 24 2.93 14.4 415 128 28.6 0.92 22 3.01 14.8 430 132 25.7 0.77 21 2.90 14.3 411 126 27.9 0.80 19 2.98 14.7 424 130 28.2 0.81 19 2.99 14.7 425 131 63 29.2 0.81 21 3.07 15.1 461 140 26.9 0.78 22 3.00 14.8 447 136 29.5 0.83 20 3.08 15.2 462 140 26.7 0.64 18 2.97 14.6 443 134 28.9 0.67 17 3.05 15.0 456 139 29.2 0.68 16 3.06 15.0 458 139 67 31.6 0.61 17 3.18 15.6 487 153 29.2 0.59 18 3.10 15.2 472 148 31.9 0.63 16 3.19 15.6 488 153 29.2 0.44 14 3.07 15.1 467 147 31.7 0.46 13 3.15 15.4 482 151 32.0 0.47 12 3.16 15.5 483 152 115 33.9 0.39 12 3.29 16.1 508 163 31.3 0.38 13 3.20 15.7 492 158 34.3 0.40 11 3.30 16.1 509 163 - - - 71 COOLING OPERATION KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 38.5 0.38 13 3.04 14.5 408 150 35.6 0.36 14 2.96 14.1 396 146 38.9 0.38 12 3.05 14.5 410 151 - - - Design Subcooling,10 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 6°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 IDB* Airflow MODEL: *PG153709041A* COOLING PERFORMANCE DATA *PG1537***41A* 23 24 MODEL: *PG153709041A* EXPANDED PERFORMANCE DATA 32.5 0.83 29 2.26 10.9 232 103 36.2 0.93 27 2.34 11.2 243 108 35.9 0.91 28 2.34 11.2 242 107 33.1 0.87 30 2.28 10.9 235 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1055 875 1125 1055 875 33.7 0.84 30 2.33 11.1 252 111 36.6 0.88 28 2.39 11.4 260 114 36.9 0.89 27 2.39 11.4 261 115 33.2 0.78 27 2.31 11.1 250 110 36.0 0.81 25 2.37 11.3 258 113 35.3 0.76 28 2.40 11.5 267 121 38.3 0.79 26 2.47 11.7 275 125 38.7 0.81 25 2.47 11.7 276 125 35.5 0.64 24 2.39 11.4 264 120 38.5 0.66 22 2.45 11.6 272 123 37.7 0.62 24 2.48 11.8 278 129 40.9 0.64 23 2.55 12.1 287 133 41.3 0.65 22 2.55 12.1 288 133 38.0 0.48 19 2.46 11.7 275 127 41.1 0.49 18 2.53 12.0 284 131 32.3 0.91 31 2.46 11.7 263 110 35.0 0.94 29 2.52 11.9 271 113 35.4 0.96 28 2.53 12.0 272 114 31.8 0.86 29 2.44 11.6 261 109 34.4 0.90 27 2.50 11.8 269 112 33.0 0.87 30 2.51 11.9 283 117 35.7 0.91 28 2.58 12.2 292 121 36.1 0.93 27 2.58 12.2 293 121 32.5 0.81 28 2.49 11.8 280 116 35.2 0.84 26 2.56 12.1 289 119 34.5 0.79 29 2.60 12.2 299 128 37.4 0.82 27 2.66 12.5 308 132 37.8 0.83 26 2.67 12.5 309 132 34.7 0.66 24 2.57 12.1 296 126 37.6 0.68 22 2.64 12.4 305 130 36.8 0.64 25 2.68 12.6 312 136 39.9 0.66 23 2.75 12.9 322 140 40.3 0.68 22 2.76 12.9 323 141 37.1 0.49 19 2.66 12.5 309 135 40.2 0.51 18 2.73 12.8 318 139 31.6 0.93 31 2.62 12.5 299 114 34.2 0.96 29 2.69 12.8 309 118 34.5 0.98 28 2.69 12.8 310 118 31.0 0.89 29 2.60 12.4 296 113 33.6 0.92 27 2.66 12.7 306 117 32.2 0.90 30 2.68 12.8 322 122 34.9 0.93 28 2.75 13.1 332 125 35.2 0.95 27 2.75 13.1 333 126 31.7 0.83 28 2.65 12.7 319 120 NOTE: 34.3 0.86 26 2.72 13.0 329 124 39.2 0.52 18 2.91 13.8 362 144 32.8 0.95 27 2.81 13.4 348 123 33.5 0.89 26 2.87 13.7 375 130 35.8 0.72 23 2.97 14.1 396 142 38.3 0.54 18 3.07 14.6 413 152 33.7 0.81 29 2.77 13.1 340 133 36.5 0.84 27 2.84 13.4 351 137 36.9 0.86 26 2.84 13.5 352 137 36.0 0.66 25 2.86 13.5 355 141 39.0 0.68 23 2.93 13.9 366 146 39.3 0.69 22 2.94 13.9 367 146 30.8 0.96 31 2.76 13.2 341 120 33.4 1.00 29 2.83 13.6 352 124 33.7 1.00 28 2.84 13.6 353 124 31.4 0.93 31 2.82 13.5 367 128 34.0 0.96 28 2.89 13.8 378 132 34.4 0.98 27 2.90 13.9 379 132 32.9 0.84 29 2.91 13.9 387 139 35.6 0.87 27 2.99 14.2 399 144 36.0 0.88 26 3.00 14.3 401 144 29.3 1.00 31 2.88 14.0 384 126 31.7 1.00 28 2.95 14.3 395 130 32.0 1.00 26 2.96 14.3 397 130 28.8 0.95 29 2.85 13.8 380 125 31.2 0.99 27 2.93 14.2 392 128 29.8 0.96 30 2.94 14.3 413 134 32.3 1.00 28 3.02 14.6 426 138 32.6 1.00 27 3.03 14.6 427 138 29.4 0.89 28 2.92 14.1 409 133 31.8 0.92 26 2.99 14.5 421 137 31.2 0.87 28 3.04 14.7 436 146 33.8 0.90 27 3.12 15.0 449 151 34.2 0.92 26 3.13 15.1 451 151 31.4 0.73 24 3.02 14.6 432 145 34.0 0.75 22 3.10 14.9 445 149 33.3 0.70 25 3.15 15.2 455 156 36.1 0.73 23 3.23 15.5 469 160 36.5 0.74 22 3.24 15.6 470 161 33.6 0.54 19 3.12 15.0 450 154 36.4 0.56 18 3.20 15.4 464 159 71 36.7 0.57 17 3.21 15.4 465 159 27.1 1.00 28 2.98 14.7 424 130 29.4 1.00 26 3.06 15.0 437 134 29.7 1.00 24 3.07 15.1 438 135 26.6 0.96 27 2.95 14.6 420 129 28.9 0.99 25 3.03 14.9 433 133 59 29.1 1.00 24 3.04 15.0 434 133 27.6 0.97 28 3.05 15.0 456 138 29.9 1.00 26 3.13 15.4 470 143 30.2 1.00 25 3.14 15.4 472 143 27.2 0.90 26 3.02 14.9 452 137 29.5 0.93 24 3.10 15.2 466 141 63 29.8 0.95 23 3.11 15.3 467 142 28.9 0.87 27 3.15 15.4 482 151 31.3 0.91 25 3.23 15.8 497 156 31.7 0.92 24 3.24 15.9 498 156 29.1 0.73 22 3.12 15.3 477 150 31.5 0.76 21 3.21 15.7 492 154 67 31.8 0.77 20 3.22 15.7 493 155 115 30.9 0.71 23 3.26 15.9 502 161 33.4 0.74 21 3.35 16.4 518 166 33.8 0.75 21 3.36 16.4 519 166 31.1 0.55 18 3.23 15.8 497 159 33.7 0.57 17 3.32 16.2 513 164 71 34.0 0.58 16 3.33 16.3 514 165 COOLING OPERATION KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 35.1 0.68 25 3.01 14.3 404 149 38.0 0.70 23 3.09 14.7 417 153 38.4 0.72 22 3.10 14.7 418 154 33.9 36.2 30.3 30.9 33.0 35.3 0.68 0.51 0.92 0.86 0.70 0.52 24 19 29 28 24 19 2.74 2.83 2.73 2.80 2.89 2.99 13.0 13.4 13.1 13.4 13.8 14.2 337 351 338 363 384 400 131 140 119 126 138 147 Shaded area reflects AHRI rating conditions 36.7 0.70 22 2.81 13.3 347 136 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 35.3 0.87 27 2.32 11.1 239 106 MBh S/T Delta T KW AMPS HI PR LO PR Design Subcooling,10 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 6°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 MBh 35.6 36.4 38.9 41.6 34.8 35.5 38.0 40.6 33.9 34.7 37.1 39.6 33.1 33.8 36.2 38.7 31.5 32.2 34.4 S/T 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.94 0.88 0.72 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.77 Delta T 26 25 21 17 26 25 22 17 26 25 22 17 26 25 22 17 26 25 22 1125 KW 2.32 2.37 2.45 2.53 2.51 2.56 2.65 2.74 2.67 2.73 2.82 2.92 2.81 2.88 2.97 3.08 2.93 3.00 3.10 AMPS 11.1 11.3 11.7 12.0 11.9 12.1 12.4 12.8 12.7 13.0 13.4 13.8 13.5 13.8 14.2 14.6 14.2 14.5 15.0 HI PR 240 258 273 285 269 290 306 319 306 330 348 363 349 376 397 414 393 423 446 LO PR 107 113 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 COOLING PERFORMANCE DATA *PG1537***41A* EXPANDED PERFORMANCE DATA 35.6 0.69 21 2.50 11.0 217 107 40.4 0.85 23 2.60 11.4 228 113 39.2 0.81 24 2.58 11.3 226 112 36.2 0.78 25 2.52 11.1 219 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1200 1050 1350 1050 1200 40.3 0.72 22 2.63 11.6 243 119 37.2 0.70 23 2.57 11.3 236 115 41.6 0.76 21 2.65 11.7 245 120 36.9 0.57 18 2.55 11.2 233 114 39.9 0.59 18 2.61 11.5 241 118 41.1 0.62 17 2.63 11.6 243 119 43.7 0.55 18 2.71 11.9 257 130 40.3 0.53 19 2.65 11.6 249 126 45.0 0.57 18 2.73 12.0 259 131 40.4 0.40 14 2.63 11.5 246 125 43.8 0.41 14 2.69 11.8 254 129 45.1 0.43 13 2.71 11.9 257 130 46.9 0.35 13 2.80 12.3 268 138 43.3 0.34 13 2.73 12.0 260 134 48.3 0.37 12 2.82 12.4 270 140 - - - 38.3 0.84 25 2.77 12.1 253 118 35.3 0.81 25 2.71 11.8 246 115 39.4 0.88 24 2.79 12.2 256 119 34.7 0.71 22 2.68 11.8 243 113 37.6 0.74 21 2.75 12.0 251 117 38.8 0.77 20 2.77 12.1 253 118 39.4 0.75 23 2.83 12.4 273 126 36.4 0.72 23 2.76 12.1 265 122 40.6 0.79 22 2.85 12.5 275 127 36.0 0.59 19 2.74 12.0 262 121 39.0 0.62 18 2.81 12.3 270 124 40.2 0.65 18 2.83 12.4 273 126 42.7 0.57 19 2.92 12.8 288 137 39.4 0.55 19 2.85 12.5 279 133 43.9 0.59 18 2.94 12.9 291 139 39.4 0.41 14 2.83 12.4 276 132 42.7 0.43 14 2.90 12.7 285 136 44.0 0.45 13 2.92 12.8 288 137 45.8 0.36 13 3.01 13.2 300 146 42.3 0.35 13 2.94 12.9 291 142 47.2 0.38 12 3.04 13.3 303 148 - - - 37.4 0.86 25 2.94 13.1 288 123 34.5 0.83 25 2.87 12.8 280 119 38.5 0.90 24 2.97 13.2 291 124 33.9 0.73 22 2.85 12.7 277 118 36.7 0.76 21 2.92 13.0 285 122 37.8 0.79 20 2.94 13.1 288 123 38.5 0.77 23 3.01 13.4 310 131 35.5 0.74 23 2.93 13.0 301 127 39.6 0.81 22 3.03 13.5 313 132 35.1 0.61 19 2.91 12.9 298 125 38.1 0.63 18 2.98 13.3 307 129 39.2 0.66 18 3.01 13.4 310 131 41.6 0.58 19 3.10 13.8 327 143 38.4 0.56 19 3.03 13.4 318 138 42.9 0.61 18 3.13 13.9 331 144 38.5 0.42 14 3.00 13.3 314 137 41.7 0.44 14 3.08 13.7 324 141 43.0 0.46 13 3.10 13.8 327 143 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 75 70 38.5 0.71 21 2.56 11.2 224 111 MBh S/T Delta T KW AMPS HI PR LO PR 1350 39.7 0.75 20 2.58 11.3 226 112 MBh S/T Delta T KW AMPS HI PR LO PR 44.7 0.37 13 3.20 14.2 342 152 41.2 0.36 13 3.12 13.9 331 147 46.0 0.39 12 3.23 14.4 345 153 - - - 36.5 0.89 25 3.09 13.9 328 129 33.6 0.85 25 3.02 13.5 318 125 37.5 0.93 24 3.12 14.0 332 130 33.1 0.75 22 2.99 13.4 315 124 35.8 0.78 21 3.07 13.8 325 128 36.9 0.82 21 3.09 13.9 328 129 37.5 0.79 23 3.16 14.2 353 137 34.6 0.76 23 3.08 13.8 343 133 38.7 0.83 22 3.19 14.3 357 139 34.3 0.63 19 3.06 13.7 339 132 37.1 0.65 19 3.14 14.1 350 136 38.3 0.68 18 3.16 14.2 353 137 40.6 0.60 19 3.26 14.6 373 150 37.5 0.58 19 3.18 14.3 362 145 41.8 0.63 18 3.29 14.8 377 151 37.6 0.44 14 3.16 14.1 358 144 40.7 0.45 14 3.24 14.5 369 148 41.9 0.47 14 3.26 14.6 373 150 34.6 0.92 24 3.22 14.7 369 135 32.0 0.89 25 3.14 14.3 358 131 35.7 0.96 23 3.25 14.8 373 137 31.4 0.78 21 3.12 14.2 355 130 34.1 0.81 21 3.20 14.6 366 134 35.1 0.85 20 3.22 14.7 369 135 35.7 0.82 22 3.29 15.0 397 144 32.9 0.79 23 3.21 14.6 385 140 36.7 0.86 22 3.32 15.2 401 145 32.6 0.65 19 3.19 14.5 382 138 35.3 0.68 18 3.27 14.9 393 142 36.4 0.71 18 3.29 15.0 397 144 38.6 0.62 18 3.40 15.5 420 157 35.6 0.60 19 3.32 15.1 407 152 39.7 0.65 18 3.43 15.6 424 159 35.7 0.45 14 3.29 15.0 403 151 38.7 0.47 14 3.37 15.4 415 155 39.8 0.49 13 3.40 15.5 420 157 41.4 0.40 13 3.51 16.0 438 167 38.2 0.39 13 3.43 15.6 425 162 42.7 0.42 12 3.54 16.2 442 169 - - - 71 59 32.1 0.93 23 3.33 15.5 408 140 29.6 0.89 23 3.25 15.1 396 136 33.0 0.97 22 3.36 15.6 412 141 29.1 0.79 20 3.22 15.0 392 134 31.5 0.82 20 3.31 15.4 404 138 32.5 0.86 19 3.33 15.5 408 140 63 33.0 0.83 21 3.41 15.9 439 149 30.5 0.80 21 3.32 15.4 426 144 34.0 0.87 20 3.44 16.0 443 150 30.2 0.66 17 3.29 15.3 422 143 32.7 0.68 17 3.38 15.7 435 147 33.7 0.71 16 3.41 15.8 439 149 67 35.7 0.63 17 3.52 16.3 464 162 33.0 0.61 17 3.43 15.9 450 158 36.8 0.66 17 3.55 16.5 468 164 33.1 0.46 13 3.40 15.8 445 156 35.8 0.47 13 3.49 16.2 459 161 36.9 0.50 12 3.52 16.3 464 162 115 38.4 0.40 12 3.64 16.9 484 173 35.4 0.39 12 3.55 16.5 469 168 39.5 0.42 11 3.67 17.1 488 175 - - - 71 COOLING OPERATION KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 43.6 0.39 13 3.37 15.1 389 160 40.2 0.37 13 3.29 14.8 377 155 44.9 0.40 12 3.40 15.3 393 161 - - - Design Subcooling,10 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 6°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 IDB* Airflow MODEL: *PG154211541A* COOLING PERFORMANCE DATA *PG1542***41A* 25 26 MODEL: *PG154211541A* EXPANDED PERFORMANCE DATA 36.8 0.85 28 2.54 11.1 221 110 41.8 0.97 28 2.64 11.6 233 115 40.6 0.93 29 2.62 11.5 230 114 37.5 0.90 29 2.56 11.2 223 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1200 1050 1350 1200 1050 38.2 0.86 29 2.61 11.5 240 118 41.4 0.90 28 2.67 11.8 248 121 42.6 0.94 27 2.69 11.9 250 123 37.6 0.80 26 2.59 11.4 238 117 40.8 0.83 26 2.65 11.7 245 120 40.0 0.78 27 2.69 11.8 254 129 43.3 0.81 27 2.76 12.1 262 133 44.6 0.85 26 2.78 12.2 264 134 40.2 0.65 23 2.67 11.7 251 127 43.5 0.68 23 2.73 12.0 259 131 42.7 0.63 24 2.77 12.2 265 137 46.2 0.66 23 2.84 12.5 273 141 47.6 0.69 22 2.87 12.6 276 143 43.0 0.49 18 2.75 12.1 262 136 46.5 0.51 18 2.82 12.4 270 140 36.6 0.93 30 2.75 12.0 251 117 39.6 0.96 29 2.82 12.3 259 121 40.8 1.00 28 2.84 12.4 261 122 36.0 0.89 28 2.73 11.9 248 116 39.0 0.92 27 2.79 12.2 256 119 37.3 0.90 29 2.81 12.3 270 124 40.4 0.93 29 2.88 12.6 278 128 41.6 0.97 28 2.90 12.7 281 130 36.7 0.83 27 2.78 12.2 267 123 39.8 0.86 26 2.85 12.5 275 127 39.1 0.81 28 2.89 12.7 285 136 42.3 0.84 27 2.97 13.0 294 140 43.6 0.88 26 2.99 13.1 297 141 39.3 0.68 23 2.87 12.6 282 134 42.5 0.70 23 2.94 12.9 291 139 41.7 0.66 24 2.99 13.1 297 145 45.1 0.68 24 3.06 13.4 306 149 46.5 0.71 23 3.09 13.5 309 151 42.0 0.51 19 2.96 13.0 294 143 45.5 0.52 18 3.04 13.3 303 148 35.7 0.95 30 2.92 13.0 285 122 38.7 0.99 29 2.99 13.3 294 125 39.9 1.00 27 3.02 13.4 297 127 35.1 0.91 28 2.90 12.9 282 120 38.0 0.94 27 2.97 13.2 291 124 36.4 0.92 29 2.98 13.3 307 129 39.4 0.95 29 3.06 13.6 316 133 40.6 1.00 28 3.08 13.7 320 135 35.9 0.85 27 2.96 13.1 304 128 NOTE: 38.9 0.88 26 3.03 13.5 313 132 44.4 0.54 18 3.23 14.4 345 153 37.1 0.97 28 3.12 14.0 332 130 37.9 0.91 26 3.19 14.3 357 139 40.5 0.74 23 3.29 14.8 377 151 43.3 0.55 18 3.40 15.3 393 161 38.1 0.83 28 3.08 13.6 324 141 41.3 0.86 27 3.15 14.0 334 146 42.5 0.90 26 3.18 14.1 337 147 40.7 0.67 24 3.18 14.1 338 150 44.1 0.70 24 3.26 14.5 348 155 45.4 0.73 23 3.28 14.6 352 157 34.8 0.98 30 3.07 13.8 325 128 37.7 1.00 29 3.15 14.1 335 132 38.9 1.00 26 3.17 14.2 338 133 35.5 0.95 29 3.13 14.1 350 136 38.5 0.98 29 3.21 14.4 360 140 39.6 1.00 27 3.24 14.6 364 141 37.2 0.86 28 3.24 14.5 369 148 40.3 0.89 27 3.32 14.9 381 153 41.5 0.93 26 3.35 15.0 384 154 33.1 1.00 29 3.20 14.6 365 134 35.9 1.00 27 3.28 15.0 377 138 36.9 1.00 25 3.30 15.1 380 139 32.5 0.97 28 3.17 14.5 362 132 35.2 1.00 27 3.25 14.8 373 137 33.7 0.98 29 3.27 14.9 393 142 36.6 1.00 28 3.35 15.3 405 147 37.6 1.00 26 3.38 15.4 409 148 33.2 0.91 27 3.24 14.8 389 141 36.0 0.95 26 3.32 15.2 401 145 35.3 0.89 27 3.37 15.4 415 155 38.3 0.92 27 3.46 15.8 428 160 39.4 0.97 26 3.49 15.9 432 162 35.5 0.74 23 3.34 15.2 411 154 38.5 0.77 23 3.43 15.6 424 159 37.7 0.72 24 3.48 15.9 433 165 40.8 0.75 23 3.57 16.3 446 171 42.1 0.78 22 3.60 16.5 451 172 38.0 0.56 18 3.45 15.8 429 164 41.1 0.58 18 3.54 16.2 442 169 71 42.4 0.60 17 3.57 16.3 446 171 30.7 1.00 27 3.31 15.4 404 138 33.2 1.00 25 3.39 15.8 416 143 34.2 1.00 23 3.42 15.9 420 144 30.1 0.98 26 3.28 15.2 400 137 32.6 1.00 25 3.36 15.6 412 141 59 33.6 1.00 23 3.39 15.8 416 143 31.3 0.99 27 3.38 15.7 434 147 33.9 1.00 26 3.46 16.1 448 152 34.9 1.00 24 3.49 16.3 452 153 30.8 0.92 25 3.35 15.6 430 146 33.4 0.95 24 3.44 16.0 443 150 63 34.4 1.00 23 3.46 16.1 448 152 32.7 0.90 26 3.49 16.2 459 161 35.5 0.93 25 3.58 16.6 473 166 36.5 0.97 24 3.61 16.8 478 167 32.9 0.75 22 3.46 16.1 454 159 35.6 0.78 21 3.55 16.5 468 164 67 36.7 0.81 20 3.58 16.6 473 166 115 34.9 0.73 22 3.61 16.8 479 171 37.8 0.75 22 3.70 17.2 493 176 39.0 0.79 21 3.73 17.4 498 178 35.2 0.56 17 3.58 16.6 474 169 38.1 0.58 17 3.67 17.1 488 175 71 39.2 0.61 16 3.70 17.2 493 176 COOLING OPERATION KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 39.7 0.69 24 3.34 15.0 385 158 43.0 0.72 24 3.43 15.4 397 163 44.3 0.76 23 3.46 15.5 401 164 38.3 41.0 34.2 35.0 37.4 40.0 0.69 0.52 0.94 0.88 0.72 0.53 23 19 28 27 23 19 3.05 3.15 3.04 3.11 3.21 3.31 13.5 14.0 13.7 14.0 14.4 14.9 321 335 322 346 365 381 140 149 126 134 147 156 Shaded area reflects AHRI rating conditions 41.5 0.72 23 3.13 13.9 331 144 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 85 80 39.9 0.89 27 2.60 11.4 228 113 MBh S/T Delta T KW AMPS HI PR LO PR Design Subcooling,10 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 6°F @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 MBh 41.1 42.0 44.8 47.9 40.1 41.0 43.8 46.8 39.2 40.0 42.8 45.7 38.2 39.0 41.7 44.6 36.3 37.1 39.6 S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.74 0.55 1.00 0.93 0.75 0.56 1.00 0.96 0.78 0.58 1.00 1.00 0.81 Delta T 26 25 22 17 26 25 22 18 27 25 22 18 26 25 22 18 25 25 22 1350 KW 2.62 2.67 2.76 2.84 2.82 2.88 2.97 3.06 2.99 3.06 3.15 3.26 3.15 3.21 3.32 3.43 3.28 3.35 3.46 AMPS 11.5 11.8 12.1 12.5 12.3 12.6 13.0 13.4 13.3 13.6 14.0 14.5 14.1 14.4 14.9 15.4 15.0 15.3 15.8 HI PR 230 248 262 273 259 278 294 306 294 316 334 348 335 360 381 397 377 405 428 LO PR 114 121 133 141 121 128 140 149 125 133 146 155 132 140 153 163 138 147 160 COOLING PERFORMANCE DATA *PG1542***41A* EXPANDED PERFORMANCE DATA 30.7 0.71 21 2.24 10.1 214 108 34.9 0.88 23 2.33 10.5 225 114 33.9 0.84 24 2.31 10.4 223 112 31.3 0.81 24 2.26 10.2 216 109 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1100 963 1238 1100 963 32.2 0.72 22 2.30 10.4 233 116 34.9 0.75 22 2.36 10.6 240 120 35.9 0.79 21 2.37 10.7 242 121 31.9 0.59 18 2.29 10.3 230 115 34.5 0.62 18 2.34 10.5 237 118 34.8 0.55 18 2.37 10.6 246 127 37.7 0.57 18 2.42 10.9 253 131 38.9 0.60 17 2.44 11.0 256 132 34.9 0.41 14 2.35 10.6 243 125 37.8 0.43 13 2.41 10.8 251 129 37.4 0.35 13 2.44 11.0 256 135 40.5 0.37 12 2.50 11.2 264 139 41.7 0.38 12 2.52 11.3 267 140 - - 30.5 0.84 24 2.42 10.8 243 115 33.1 0.87 24 2.47 11.1 250 119 34.1 0.91 23 2.49 11.2 253 120 30.0 0.74 21 2.40 10.8 240 114 32.5 0.76 21 2.46 11.0 248 118 31.4 0.75 22 2.47 11.0 261 123 34.1 0.78 22 2.52 11.3 269 126 35.1 0.81 21 2.54 11.4 272 128 31.1 0.62 18 2.45 11.0 258 121 33.7 0.64 18 2.51 11.2 266 125 34.0 0.57 18 2.54 11.3 276 134 36.9 0.59 18 2.60 11.6 284 138 38.0 0.62 17 2.62 11.7 287 139 34.1 0.43 14 2.52 11.3 273 132 36.9 0.44 14 2.58 11.5 281 137 36.5 0.36 13 2.62 11.7 288 143 39.6 0.38 13 2.68 12.0 296 147 40.7 0.40 12 2.70 12.0 299 148 - - 29.8 0.86 24 2.56 11.6 276 120 32.3 0.89 24 2.62 11.9 285 123 33.3 0.93 23 2.64 11.9 287 125 29.3 0.76 21 2.54 11.5 273 119 31.7 0.78 21 2.60 11.8 282 122 30.7 0.77 23 2.61 11.8 297 127 33.2 0.80 22 2.67 12.1 306 131 34.2 0.84 21 2.69 12.2 309 133 30.4 0.63 18 2.59 11.7 294 126 32.9 0.65 18 2.65 12.0 303 130 33.2 0.58 18 2.69 12.1 314 139 36.0 0.60 18 2.76 12.4 323 143 37.1 0.63 17 2.78 12.5 327 145 33.3 0.44 14 2.67 12.0 310 138 36.1 0.45 14 2.73 12.3 320 142 - - 35.6 0.37 13 2.77 12.5 327 148 38.6 0.39 13 2.84 12.8 337 153 39.8 0.41 12 2.86 12.9 341 154 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 33.3 0.74 21 2.29 10.3 221 111 MBh S/T Delta T KW AMPS HI PR LO PR 29.1 0.89 25 2.68 12.2 314 126 31.5 0.92 24 2.75 12.5 324 130 32.4 0.96 23 2.77 12.6 327 131 28.6 0.78 21 2.66 12.1 311 125 31.0 0.81 21 2.73 12.4 321 128 29.9 0.79 23 2.74 12.5 338 134 32.4 0.60 19 2.82 12.8 357 146 35.1 0.62 18 2.89 13.1 368 151 36.2 0.65 18 2.92 13.2 372 152 33.4 0.86 21 2.83 12.9 352 139 32.4 0.82 22 2.81 12.8 349 138 32.5 0.45 14 2.80 12.7 354 145 35.2 0.47 14 2.87 13.0 365 149 29.6 0.65 18 2.72 12.4 335 132 32.1 0.68 18 2.78 12.7 345 137 27.6 0.92 24 2.79 12.9 354 132 29.9 0.95 24 2.86 13.2 365 136 30.8 1.00 23 2.88 13.3 368 137 27.2 0.81 21 2.77 12.8 350 131 29.4 0.84 21 2.84 13.1 361 135 28.4 0.82 22 2.85 13.1 381 140 30.8 0.85 22 2.92 13.5 392 145 31.7 0.90 21 2.94 13.6 396 146 28.2 0.68 18 2.83 13.0 377 139 30.5 0.70 18 2.89 13.4 388 143 30.8 0.62 18 2.94 13.5 402 153 33.3 0.65 18 3.01 13.8 414 158 34.4 0.68 17 3.03 13.9 418 159 30.8 0.47 14 2.91 13.4 398 152 33.4 0.49 14 2.99 13.7 410 156 33.0 0.40 13 3.03 13.9 419 163 35.8 0.42 12 3.11 14.3 432 168 36.9 0.44 12 3.13 14.4 436 170 - - 25.6 0.93 23 2.88 13.5 391 136 27.7 0.96 22 2.95 13.8 403 141 28.6 1.00 21 2.98 14.0 407 142 25.2 0.82 20 2.86 13.4 387 135 27.3 0.85 19 2.93 13.7 399 139 26.3 0.83 21 2.94 13.8 420 145 28.5 0.86 21 3.01 14.1 433 150 29.4 0.90 20 3.04 14.2 438 151 26.1 0.68 17 2.92 13.7 416 144 28.3 0.71 17 2.99 14.0 429 148 28.5 0.63 17 3.03 14.2 444 158 30.9 0.65 17 3.11 14.5 458 163 31.8 0.68 16 3.14 14.7 462 165 28.6 0.47 13 3.01 14.1 439 157 31.0 0.49 13 3.08 14.4 453 162 30.6 0.40 12 3.13 14.7 463 169 33.2 0.42 12 3.21 15.0 477 174 34.2 0.44 11 3.24 15.1 482 176 - - KW = Total system power AMPS: Unit amps (com p.+ evaporator + condenser fan motors) 34.8 0.39 13 2.91 13.2 373 156 37.7 0.40 13 2.98 13.5 384 160 38.8 0.42 12 3.01 13.7 388 162 - - 71 - COO LING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Temperature Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 MBh 34.3 35.5 38.9 33.5 34.7 38.0 32.7 33.9 37.1 31.9 33.1 36.2 30.3 31.4 34.4 28.1 29.1 31.9 S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 0.74 0.51 Delta T 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 19 16 12 1238 KW 2.31 2.35 2.42 2.47 2.52 2.60 2.62 2.67 2.76 2.75 2.81 2.89 2.86 2.92 3.01 2.95 3.01 3.11 AMPS 10.4 10.6 10.9 11.1 11.3 11.6 11.9 12.1 12.4 12.5 12.8 13.1 13.2 13.5 13.8 13.8 14.1 14.5 HI PR 223 240 253 250 269 284 284 306 323 324 349 368 364 392 414 403 433 458 LO PR 112 120 131 119 126 138 123 131 143 130 138 151 136 145 158 141 150 163 MOD EL: *PG1548***41A* COOLING PERFORMANCE DATA 1ST STAGE *PG1548***41A* 27 28 EXPANDED PERFORMANCE DATA 31.8 0.89 27 2.28 10.3 218 110 36.1 1.00 27 2.36 10.6 230 116 35.1 0.96 28 2.34 10.6 227 115 32.4 0.93 29 2.29 10.3 221 111 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1100 963 1238 1100 963 33.0 0.90 28 2.34 10.5 237 118 35.7 0.93 28 2.39 10.8 245 122 36.8 0.98 27 2.41 10.8 247 123 32.5 0.83 26 2.32 10.5 235 117 35.2 0.86 25 2.37 10.7 242 121 34.6 0.81 27 2.41 10.8 251 129 37.4 0.84 26 2.46 11.0 258 133 38.6 0.88 25 2.48 11.1 261 135 34.7 0.68 22 2.39 10.7 248 128 37.6 0.70 22 2.44 11.0 256 132 36.9 0.66 23 2.48 11.1 261 138 39.9 0.68 23 2.54 11.4 270 142 41.1 0.71 22 2.55 11.5 272 143 37.1 0.51 18 2.46 11.0 259 136 40.2 0.52 18 2.52 11.3 267 140 31.6 0.96 29 2.46 11.0 248 118 34.3 1.00 29 2.51 11.2 255 121 35.3 1.00 26 2.53 11.3 258 122 31.1 0.92 27 2.44 10.9 245 116 33.7 0.95 27 2.49 11.2 253 120 32.2 0.93 29 2.50 11.2 266 125 34.9 0.96 28 2.56 11.5 275 129 36.0 1.00 27 2.58 11.5 277 130 31.7 0.86 26 2.49 11.1 264 124 34.4 0.89 26 2.54 11.4 272 128 33.8 0.84 27 2.58 11.5 281 137 36.6 0.87 27 2.64 11.8 290 141 37.7 0.91 26 2.66 11.9 293 142 33.9 0.70 23 2.56 11.4 279 135 36.8 0.73 22 2.62 11.7 287 139 36.0 0.68 23 2.66 11.9 293 145 39.0 0.71 23 2.72 12.1 302 150 40.2 0.74 22 2.74 12.2 306 151 36.3 0.52 18 2.64 11.8 291 144 39.3 0.54 18 2.70 12.0 299 148 30.9 0.99 29 2.60 11.8 282 122 33.4 1.00 28 2.66 12.0 290 126 34.4 1.00 26 2.68 12.1 293 127 30.3 0.94 27 2.58 11.7 279 121 32.9 0.98 27 2.64 11.9 287 125 31.5 0.95 29 2.65 12.0 303 130 34.1 0.99 28 2.72 12.3 312 134 35.1 1.00 26 2.74 12.4 315 135 31.0 0.88 26 2.63 11.9 300 129 33.6 0.92 26 2.69 12.2 309 133 32.9 0.86 27 2.73 12.3 320 142 35.7 0.89 27 2.80 12.6 330 146 36.8 0.94 26 2.82 12.7 333 148 33.1 0.72 23 2.71 12.2 317 141 35.9 0.75 22 2.78 12.5 327 145 35.1 0.70 23 2.82 12.7 334 151 38.1 0.72 23 2.89 13.0 344 156 39.2 0.76 22 2.91 13.1 347 157 35.4 0.54 18 2.80 12.6 330 150 38.4 0.56 18 2.86 12.9 341 154 Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 34.5 0.92 26 2.33 10.5 225 114 MBh S/T Delta T KW AMPS HI PR LO PR 30.1 1.00 29 2.73 12.4 321 128 32.6 1.00 27 2.79 12.7 331 132 33.6 1.00 25 2.81 12.8 334 134 29.6 0.97 27 2.71 12.3 317 127 32.1 1.00 27 2.77 12.6 327 131 30.7 0.98 29 2.78 12.7 345 137 33.3 1.00 28 2.85 13.0 356 141 34.2 1.00 25 2.87 13.1 359 142 30.2 0.91 26 2.76 12.6 342 135 32.8 0.95 26 2.83 12.9 352 139 32.1 0.89 27 2.87 13.0 364 149 34.8 0.92 27 2.94 13.3 376 154 35.9 0.97 26 2.96 13.4 379 155 32.3 0.74 23 2.85 12.9 361 148 35.0 0.77 23 2.92 13.2 372 152 28.6 1.00 27 2.83 13.1 361 135 31.0 1.00 26 2.90 13.4 372 139 31.9 1.00 24 2.93 13.5 376 140 28.1 1.01 27 2.81 13.0 357 133 30.5 1.00 25 2.88 13.3 368 137 29.2 1.00 28 2.89 13.4 388 143 31.6 1.00 26 2.96 13.7 400 148 32.5 1.00 24 2.99 13.8 404 149 28.7 0.95 26 2.87 13.2 384 142 31.1 0.98 26 2.94 13.6 396 146 30.5 0.92 27 2.98 13.7 410 156 33.1 0.96 26 3.06 14.1 423 161 34.1 1.00 25 3.08 14.2 427 163 30.7 0.77 23 2.96 13.6 406 155 33.3 0.80 22 3.03 14.0 418 159 32.6 0.75 23 3.08 14.2 428 166 35.3 0.78 23 3.16 14.5 441 172 36.4 0.81 22 3.18 14.6 445 173 32.8 0.58 18 3.06 14.1 423 165 35.5 0.60 18 3.13 14.4 436 170 26.5 1.00 25 2.93 13.7 399 139 28.7 1.00 24 3.00 14.1 411 143 29.6 1.00 22 3.02 14.2 415 145 26.0 1.02 25 2.90 13.6 395 138 28.2 1.00 24 2.98 14.0 407 142 27.0 1.00 26 2.99 14.0 429 148 29.3 1.00 24 3.06 14.4 442 153 30.1 1.00 22 3.09 14.5 447 154 26.6 0.95 24 2.97 13.9 425 147 28.8 0.99 24 3.04 14.2 438 151 63 29.7 1.00 22 3.06 14.4 442 153 28.3 0.93 25 3.08 14.4 453 162 30.6 0.96 25 3.16 14.8 467 167 31.6 1.00 23 3.19 14.9 472 168 28.4 0.78 21 3.06 14.3 448 160 30.8 0.81 21 3.14 14.7 462 165 67 31.7 0.84 20 3.16 14.8 467 167 115 30.2 0.75 22 3.18 14.9 472 172 32.7 0.78 21 3.26 15.3 487 177 33.7 0.82 21 3.29 15.4 492 179 30.4 0.58 17 3.16 14.8 468 170 32.9 0.60 17 3.24 15.1 482 176 71 33.9 0.63 16 3.26 15.3 487 177 KW = Total system power AMPS: Unit amps (com p.+ evaporator + condenser fan motors) 34.3 0.72 24 2.96 13.4 380 159 37.2 0.75 23 3.03 13.8 392 164 38.3 0.78 22 3.06 13.9 396 165 34.5 0.55 18 2.94 13.3 376 157 37.4 0.58 18 3.01 13.7 388 162 59 29.1 1.00 22 3.00 14.1 411 143 connection. COO LING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 35.5 36.3 38.8 41.4 34.7 35.4 37.9 40.5 33.8 34.6 37.0 39.5 33.0 33.7 36.1 38.5 31.4 32.1 34.2 36.6 S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 Delta T 25 24 21 17 26 25 21 17 25 25 21 17 25 25 22 17 23 24 21 17 1238 KW 2.34 2.39 2.46 2.54 2.51 2.56 2.64 2.72 2.66 2.72 2.80 2.89 2.79 2.85 2.94 3.03 2.90 2.96 3.06 3.16 AMPS 10.6 10.8 11.0 11.4 11.2 11.5 11.8 12.1 12.0 12.3 12.6 13.0 12.7 13.0 13.3 13.8 13.4 13.7 14.1 14.5 HI PR 227 245 258 270 255 275 290 302 290 312 330 344 331 356 376 392 372 400 423 441 LO PR 115 122 133 142 121 129 141 150 126 134 146 156 132 141 154 164 139 148 161 172 MOD EL: *PG1548***41A* COOLING PERFORMANCE DATA 1ST STAGE *PG1548***41A* EXPANDED PERFORMANCE DATA 47.3 0.88 23 3.46 16.0 246 112 46.0 0.84 23 3.43 15.9 244 111 42.4 0.81 24 3.36 15.6 236 107 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1321 1699 1510 1321 43.7 0.72 22 3.42 15.9 254 114 47.3 0.75 22 3.50 16.2 262 118 48.7 0.79 21 3.53 16.3 265 119 43.2 0.59 18 3.40 15.8 252 113 47.3 0.55 18 3.52 16.3 268 125 51.2 0.57 18 3.60 16.6 277 129 52.8 0.60 17 3.63 16.7 280 130 47.4 0.41 14 3.50 16.2 266 124 51.3 0.43 13 3.58 16.5 274 127 50.7 0.35 12 3.63 16.7 280 133 55.0 0.37 12 3.71 17.1 289 137 56.6 0.38 12 3.74 17.2 292 138 - - 41.4 0.84 24 3.59 16.6 265 114 44.9 0.87 24 3.68 16.9 273 117 46.2 0.91 23 3.70 17.0 276 118 40.7 0.74 21 3.57 16.4 262 112 44.1 0.76 21 3.65 16.8 271 116 42.7 0.75 22 3.66 16.9 285 121 46.2 0.78 22 3.75 17.2 294 125 47.6 0.81 21 3.78 17.3 297 126 42.2 0.62 18 3.64 16.7 282 120 45.7 0.64 18 3.72 17.1 291 123 46.2 0.57 18 3.77 17.3 301 132 50.0 0.59 18 3.86 17.7 311 136 51.5 0.62 17 3.89 17.8 314 137 46.3 0.43 14 3.74 17.2 298 131 50.1 0.44 13 3.83 17.5 307 135 49.6 0.36 13 3.88 17.8 314 140 53.7 0.38 12 3.97 18.2 324 145 55.3 0.40 12 4.01 18.3 327 146 - - 40.4 0.86 24 3.80 17.7 302 118 43.8 0.89 24 3.89 18.0 311 122 45.1 0.93 23 3.92 18.2 314 123 39.8 0.76 21 3.77 17.5 298 117 43.1 0.78 21 3.86 17.9 308 120 41.6 0.77 22 3.88 18.0 324 126 45.1 0.80 22 3.97 18.4 335 129 46.5 0.84 21 4.00 18.5 338 131 41.2 0.63 18 3.85 17.9 321 124 44.7 0.65 18 3.94 18.2 331 128 45.1 0.58 18 3.99 18.5 343 137 48.8 0.60 18 4.09 18.9 353 141 50.3 0.63 17 4.12 19.0 357 143 45.2 0.44 14 3.96 18.3 339 136 48.9 0.45 14 4.05 18.7 350 140 - - 48.4 0.37 13 4.11 19.0 357 146 52.4 0.39 12 4.21 19.4 368 150 54.0 0.41 12 4.24 19.6 372 152 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 41.7 0.71 21 3.34 15.5 234 106 MBh S/T Delta T KW AMPS HI PR LO PR 1510 46.8 0.62 18 3.48 16.1 259 117 39.5 0.89 24 3.98 18.6 343 124 42.8 0.92 24 4.08 19.0 354 128 44.0 0.96 23 4.11 19.2 358 129 38.8 0.78 21 3.95 18.5 340 123 42.0 0.81 21 4.04 18.9 350 126 40.6 0.79 22 4.06 19.0 370 132 44.0 0.60 18 4.19 19.5 390 144 47.6 0.62 18 4.29 19.9 402 148 49.1 0.65 17 4.32 20.0 406 150 45.3 0.86 21 4.19 19.5 385 137 44.0 0.82 22 4.16 19.4 381 136 44.1 0.45 14 4.15 19.3 386 143 47.7 0.47 14 4.25 19.8 398 147 40.2 0.65 18 4.03 18.8 366 131 43.6 0.68 18 4.13 19.2 377 135 37.5 0.92 24 4.14 19.5 386 130 40.6 0.95 24 4.23 20.0 398 134 41.8 1.00 23 4.27 20.1 402 135 36.9 0.81 21 4.10 19.4 382 129 39.9 0.84 20 4.20 19.8 394 133 38.6 0.82 22 4.22 19.9 416 138 41.8 0.85 22 4.32 20.4 429 142 43.1 0.90 21 4.36 20.5 433 144 38.2 0.68 18 4.19 19.8 412 137 41.4 0.70 18 4.29 20.2 424 141 41.8 0.62 18 4.35 20.5 439 151 45.3 0.65 18 4.46 20.9 453 156 46.6 0.68 17 4.49 21.1 457 157 41.9 0.47 14 4.32 20.3 435 149 45.4 0.49 13 4.42 20.8 448 154 44.8 0.40 13 4.49 21.1 458 161 48.6 0.42 12 4.60 21.6 472 166 50.0 0.44 12 4.63 21.7 477 167 - - 34.7 0.93 22 4.27 20.5 427 134 37.6 0.96 22 4.37 20.9 440 139 38.7 1.00 21 4.41 21.1 444 140 34.1 0.82 19 4.24 20.3 423 133 37.0 0.85 19 4.34 20.8 436 137 35.8 0.83 21 4.36 20.9 459 143 38.7 0.86 20 4.46 21.4 474 147 39.9 0.90 19 4.50 21.5 478 149 35.4 0.68 17 4.32 20.7 455 141 38.3 0.71 17 4.43 21.2 469 146 38.7 0.63 17 4.49 21.5 485 156 41.9 0.65 17 4.60 22.0 500 161 43.2 0.68 16 4.64 22.1 505 162 38.8 0.47 13 4.46 21.3 480 154 42.0 0.49 13 4.57 21.8 495 159 41.5 0.40 12 4.63 22.1 506 166 45.0 0.42 11 4.75 22.6 522 171 46.3 0.44 11 4.79 22.8 527 173 - - 71 - KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 47.2 0.39 13 4.31 20.0 407 153 51.1 0.40 12 4.42 20.5 420 158 52.7 0.42 12 4.45 20.7 424 160 - - 67 43.3 0.51 12 4.60 22.0 500 161 2ND STAGE 75 70 45.2 0.74 20 3.41 15.8 241 110 MBh S/T Delta T KW AMPS HI PR LO PR 63 39.5 0.74 16 4.46 21.4 473 147 115 CO OLING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 46.5 48.2 52.9 45.5 47.1 51.6 44.4 46.0 50.4 43.3 44.9 49.2 41.1 42.6 46.7 38.1 S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 Delta T 19 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 1699 KW 3.43 3.50 3.60 3.67 3.75 3.86 3.89 3.97 4.08 4.07 4.16 4.28 4.23 4.32 4.45 4.37 AMPS 15.9 16.2 16.6 16.9 17.2 17.7 18.0 18.4 18.9 19.0 19.4 19.9 20.0 20.4 20.9 20.9 HI PR 244 262 277 273 294 311 311 334 353 354 381 402 398 429 453 440 LO PR 111 118 129 117 124 136 122 129 141 128 136 148 134 142 156 138 MODEL: *PG1548***41A* COOLING PERFORMANCE DATA *PG1548***41A* 29 30 EXPANDED PERFORMANCE DATA 49.0 1.00 27 3.51 16.3 251 114 47.6 0.96 28 3.48 16.2 249 113 43.9 0.93 28 3.41 15.8 241 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1321 1699 1510 1321 44.8 0.90 28 3.47 16.1 259 117 48.5 0.93 27 3.55 16.5 267 120 50.0 0.98 26 3.58 16.6 270 121 44.1 0.83 26 3.45 16.0 257 115 46.9 0.81 26 3.57 16.5 274 127 50.8 0.84 26 3.66 16.9 282 131 52.3 0.88 25 3.68 17.0 285 133 47.1 0.68 22 3.55 16.4 271 126 51.1 0.70 22 3.63 16.7 280 130 50.0 0.66 23 3.68 17.0 286 136 54.2 0.68 22 3.76 17.3 295 140 55.8 0.71 22 3.79 17.5 297 141 50.4 0.51 18 3.65 16.9 283 134 54.6 0.52 17 3.74 17.2 292 138 42.9 0.96 29 3.65 16.8 270 116 46.5 1.00 28 3.73 17.2 279 119 47.9 1.00 26 3.76 17.3 282 121 42.2 0.92 27 3.62 16.7 268 115 45.7 0.95 27 3.70 17.0 276 118 43.7 0.93 28 3.72 17.1 291 123 47.4 0.96 28 3.80 17.5 300 127 48.8 1.00 26 3.83 17.6 303 128 43.1 0.86 26 3.69 17.0 288 122 46.7 0.89 25 3.78 17.3 297 126 45.8 0.84 27 3.83 17.5 307 135 49.6 0.87 26 3.92 17.9 317 139 51.1 0.91 25 3.95 18.0 320 140 46.0 0.70 22 3.80 17.4 304 133 49.9 0.73 22 3.89 17.8 314 137 48.9 0.68 23 3.94 18.0 321 143 52.9 0.71 23 4.04 18.4 330 148 54.5 0.74 22 4.07 18.6 334 149 49.2 0.52 18 3.91 17.9 317 142 53.3 0.54 18 4.01 18.3 327 146 41.9 0.99 29 3.86 17.9 308 120 45.4 1.00 28 3.95 18.3 317 124 46.7 1.00 25 3.98 18.4 320 125 41.2 0.94 27 3.83 17.8 305 119 44.6 0.98 27 3.92 18.2 314 123 42.7 0.95 28 3.93 18.2 331 128 46.3 0.99 28 4.03 18.7 341 132 47.6 1.00 26 4.06 18.8 345 133 42.1 0.88 26 3.91 18.1 328 127 45.6 0.92 25 4.00 18.5 338 131 44.7 0.86 27 4.05 18.7 350 140 48.4 0.89 26 4.15 19.1 360 144 49.9 0.94 25 4.18 19.3 364 146 44.9 0.72 22 4.02 18.6 346 138 48.7 0.75 22 4.12 19.0 357 143 47.7 0.70 23 4.18 19.3 365 149 51.7 0.72 23 4.28 19.7 376 154 53.2 0.76 22 4.31 19.9 380 155 48.0 0.54 18 4.14 19.1 361 147 52.0 0.56 18 4.24 19.6 372 152 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 43.2 0.89 27 3.38 15.7 239 109 MBh S/T Delta T KW AMPS HI PR LO PR 1510 47.8 0.86 25 3.53 16.3 265 119 40.9 1.00 28 4.04 18.9 350 126 44.3 1.00 27 4.14 19.3 361 130 45.6 1.00 25 4.17 19.4 365 132 40.2 0.97 27 4.01 18.7 347 125 43.5 1.00 26 4.11 19.2 358 129 41.7 0.98 29 4.13 19.2 377 135 45.1 1.00 27 4.22 19.7 389 139 46.5 1.00 25 4.26 19.8 393 140 41.0 0.91 26 4.09 19.1 373 133 44.5 0.95 26 4.19 19.5 385 137 43.6 0.89 27 4.25 19.7 398 147 47.3 0.92 26 4.35 20.2 410 151 48.7 0.97 25 4.39 20.3 415 153 43.8 0.74 23 4.22 19.6 394 145 47.5 0.77 22 4.32 20.0 406 150 38.8 1.00 27 4.20 19.8 394 133 42.1 1.00 26 4.30 20.3 406 137 43.3 1.00 23 4.33 20.4 410 138 38.2 1.01 27 4.17 19.7 390 131 41.3 1.00 25 4.27 20.1 402 135 39.6 1.00 28 4.29 20.2 424 141 42.9 1.00 26 4.39 20.7 437 145 44.2 1.00 24 4.42 20.8 442 147 39.0 0.95 26 4.25 20.1 420 140 42.2 0.98 25 4.36 20.5 433 144 41.4 0.92 27 4.42 20.8 448 154 44.9 0.96 26 4.53 21.3 462 159 46.2 1.00 25 4.56 21.4 466 160 41.7 0.77 22 4.38 20.6 443 152 45.1 0.80 22 4.49 21.1 457 157 44.2 0.75 23 4.56 21.4 467 164 47.9 0.78 23 4.67 21.9 482 169 49.3 0.81 22 4.71 22.1 486 171 44.5 0.58 18 4.52 21.3 463 162 48.2 0.60 18 4.63 21.8 477 167 36.0 1.00 25 4.34 20.8 436 137 39.0 1.00 24 4.44 21.3 449 141 40.1 1.00 22 4.48 21.4 453 143 35.3 1.02 25 4.30 20.6 431 136 38.3 1.00 23 4.41 21.1 445 140 36.7 1.00 26 4.43 21.2 469 146 39.7 1.00 24 4.53 21.7 483 150 40.9 1.00 22 4.57 21.9 488 152 36.1 0.95 24 4.39 21.0 464 144 39.1 0.99 24 4.50 21.5 478 149 38.4 0.93 25 4.56 21.8 495 159 41.6 0.96 24 4.68 22.3 510 164 42.8 1.00 23 4.71 22.5 515 166 38.6 0.78 21 4.53 21.6 490 158 41.8 0.81 21 4.64 22.1 505 163 41.0 0.75 21 4.71 22.5 516 170 44.4 0.78 21 4.82 23.0 532 175 45.7 0.82 20 4.86 23.2 537 177 41.2 0.58 17 4.67 22.3 511 168 44.7 0.60 16 4.79 22.8 527 173 71 46.0 0.63 16 4.82 23.0 532 175 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 46.5 0.72 23 4.38 20.3 415 156 50.4 0.75 23 4.49 20.8 428 161 51.9 0.78 22 4.52 21.0 432 163 46.9 0.55 18 4.35 20.2 411 155 50.8 0.58 18 4.45 20.7 424 160 67 43.1 0.84 20 4.68 22.3 510 164 2ND STAGE 85 80 46.8 0.92 26 3.46 16.0 246 112 MBh S/T Delta T KW AMPS HI PR LO PR 63 40.3 1.00 22 4.53 21.7 483 150 115 CO OLING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 48.2 49.2 52.6 56.2 47.1 48.1 51.4 54.9 45.9 46.9 50.1 53.6 44.8 45.8 48.9 52.3 42.6 43.5 46.5 49.7 39.4 S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 1.00 Delta T 25 24 21 17 25 24 21 17 25 24 21 17 24 25 21 17 23 24 21 17 21 1699 KW 3.48 3.55 3.66 3.76 3.73 3.80 3.92 4.04 3.95 4.03 4.15 4.28 4.14 4.22 4.35 4.49 4.30 4.39 4.53 4.67 4.44 AMPS 16.2 16.5 16.9 17.3 17.2 17.5 17.9 18.4 18.3 18.7 19.1 19.7 19.3 19.7 20.2 20.8 20.3 20.7 21.3 21.9 21.3 HI PR 249 267 282 295 279 300 317 330 317 341 360 376 361 389 410 428 406 437 462 482 449 LO PR 113 120 131 140 119 127 139 148 124 132 144 154 130 139 151 161 137 145 159 169 141 MODEL: *PG1548***41A* COOLING PERFORMANCE DATA *PG1548***41A* 32.8 0.73 21 2.15 10.8 217 114 32.5 0.72 21 2.13 10.7 214 113 34.5 0.88 21 2.20 11.0 224 118 33.4 0.83 24 2.17 10.9 219 115 33.0 0.82 24 2.15 10.8 217 114 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1065 1050 1350 63 34.4 0.74 22 2.21 11.1 236 123 34.0 0.73 22 2.19 11.0 233 121 35.6 0.79 19 2.24 11.2 241 125 33.7 0.60 18 2.17 10.9 231 120 34.0 0.61 18 2.19 11.0 234 121 35.2 0.65 15 2.23 11.1 238 124 67 37.2 0.56 18 2.27 11.3 249 134 36.8 0.55 18 2.25 11.2 246 132 38.5 0.60 16 2.31 11.5 254 137 36.9 0.42 13 2.24 11.2 244 131 37.3 0.42 14 2.26 11.3 247 133 38.6 0.45 12 2.29 11.4 252 135 39.9 0.36 12 2.34 11.6 260 143 39.5 0.36 12 2.32 11.5 257 141 41.3 0.38 11 2.38 11.8 265 145 - - - 71 59 32.6 0.86 24 2.32 11.5 246 122 32.3 0.85 24 2.30 11.4 243 120 33.7 0.91 21 2.36 11.7 251 124 31.7 0.75 21 2.28 11.3 241 119 32.1 0.75 21 2.30 11.4 244 121 33.2 0.80 18 2.34 11.6 249 123 63 33.6 0.77 22 2.37 11.7 265 130 33.2 0.76 22 2.35 11.6 261 128 34.7 0.82 19 2.41 11.9 270 132 32.9 0.62 18 2.33 11.5 259 127 33.2 0.63 18 2.35 11.6 262 128 34.4 0.67 16 2.39 11.8 267 131 67 36.3 0.58 18 2.44 12.0 280 141 36.0 0.57 18 2.42 11.9 276 140 37.6 0.62 16 2.48 12.1 285 144 36.0 0.43 14 2.40 11.8 273 138 36.4 0.44 14 2.42 11.9 277 140 37.7 0.46 12 2.46 12.1 282 143 39.0 0.37 13 2.52 12.3 292 151 38.6 0.37 12 2.49 12.2 288 149 40.4 0.40 11 2.56 12.5 298 154 - - - 71 59 31.8 0.88 24 2.46 12.2 280 127 31.5 0.87 24 2.44 12.1 276 125 32.9 0.93 21 2.50 12.4 286 129 31.0 0.77 21 2.42 12.0 274 124 31.3 0.77 21 2.44 12.1 277 125 32.4 0.82 18 2.48 12.3 283 128 32.8 0.79 22 2.51 12.4 301 135 32.4 0.78 22 2.49 12.3 297 133 33.9 0.84 19 2.55 12.6 307 137 32.1 0.64 18 2.47 12.2 294 132 32.4 0.65 18 2.49 12.4 298 133 33.6 0.69 16 2.53 12.5 304 136 35.5 0.60 18 2.59 12.7 318 147 35.1 0.59 18 2.56 12.6 314 145 36.7 0.63 16 2.63 12.9 324 150 35.2 0.44 14 2.54 12.5 311 144 35.5 0.45 14 2.57 12.7 315 146 36.8 0.48 12 2.61 12.8 321 148 38.1 0.38 13 2.67 13.1 332 157 37.7 0.38 13 2.64 13.0 328 155 39.4 0.41 11 2.71 13.3 338 160 - - - 31.1 0.91 24 2.58 12.8 319 133 30.7 0.90 24 2.56 12.7 315 131 32.1 0.96 21 2.62 13.0 325 136 30.2 0.79 21 2.54 12.6 312 130 30.5 0.80 21 2.56 12.8 316 132 31.6 0.85 18 2.60 12.9 322 134 32.0 0.81 22 2.64 13.1 343 141 31.6 0.80 22 2.61 13.0 339 140 33.1 0.86 19 2.68 13.3 350 144 31.3 0.66 18 2.59 12.9 335 138 31.6 0.67 18 2.61 13.0 340 140 32.8 0.71 16 2.66 13.2 346 143 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 1050 1065 1350 MBh S/T Delta T KW AMPS HI PR LO PR 59 34.0 0.77 18 2.18 11.0 222 116 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 75 67 34.6 0.61 18 2.72 13.4 362 154 34.3 0.61 18 2.69 13.3 358 152 35.8 0.65 16 2.76 13.6 370 158 34.3 0.46 14 2.67 13.2 354 151 34.7 0.46 14 2.70 13.3 359 153 35.9 0.49 12 2.74 13.5 366 156 59 29.5 0.94 24 2.69 13.5 359 139 29.2 0.93 24 2.66 13.3 354 138 30.5 1.00 21 2.73 13.6 366 142 28.7 0.82 21 2.64 13.2 350 136 29.0 0.83 21 2.66 13.4 355 138 30.0 0.88 18 2.71 13.6 362 141 63 30.4 0.84 22 2.74 13.7 386 148 30.1 0.83 22 2.71 13.6 381 146 31.4 0.90 19 2.79 13.9 394 151 29.8 0.69 18 2.69 13.5 377 145 30.1 0.69 18 2.72 13.6 382 147 31.1 0.74 16 2.76 13.8 390 150 67 32.9 0.64 18 2.83 14.1 408 162 32.5 0.63 18 2.80 13.9 402 160 34.0 0.68 16 2.87 14.3 416 165 32.6 0.47 14 2.78 13.8 398 158 32.9 0.48 14 2.81 14.0 404 160 34.1 0.51 12 2.85 14.2 412 163 35.3 0.41 12 2.92 14.5 425 172 34.9 0.41 12 2.89 14.3 420 170 36.5 0.44 11 2.97 14.7 434 176 - - - 71 59 27.3 0.95 22 2.77 14.1 396 144 27.1 0.94 22 2.75 13.9 391 142 28.3 1.00 19 2.82 14.3 404 147 26.6 0.83 19 2.72 13.8 387 141 26.9 0.84 19 2.75 14.0 392 143 27.8 0.89 17 2.80 14.2 400 146 63 28.1 0.85 21 2.83 14.3 427 153 27.9 0.84 21 2.80 14.2 421 151 29.1 0.90 18 2.88 14.5 435 156 27.6 0.69 17 2.78 14.1 417 150 27.8 0.70 17 2.81 14.2 422 152 28.8 0.74 15 2.86 14.4 431 155 67 30.5 0.64 17 2.92 14.7 450 167 30.1 0.64 17 2.89 14.6 445 165 31.5 0.68 15 2.97 14.9 459 171 30.2 0.48 13 2.87 14.5 440 164 30.5 0.48 13 2.90 14.6 446 166 31.6 0.51 11 2.95 14.8 455 169 115 32.7 0.41 12 3.02 15.2 470 178 32.4 0.41 12 2.99 15.0 464 176 33.8 0.44 10 3.07 15.4 479 182 - - - 71 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 37.1 0.40 13 2.80 13.8 378 164 36.8 0.39 13 2.78 13.7 373 162 38.4 0.42 11 2.85 14.0 385 168 - - - 71 105 1ST STAGE 75 70 IDB* 65 1st Stage COOLING OPERATION EXPANDED PERFORMANCE DATA MODEL: *PG154911541A* Design Subcooling, 12 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 12°F @ the compressor suction access fitting connection. COOLING PERFORMANCE DATA *PG1549***41A* 31 32 34.0 0.91 27 2.18 11.0 222 116 33.6 0.90 26 2.16 10.9 219 115 35.8 1.00 24 2.23 11.2 228 120 34.6 0.95 28 2.20 11.0 224 118 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1065 1050 1350 35.2 0.92 28 2.24 11.2 241 125 36.5 0.98 24 2.28 11.4 246 128 34.4 0.84 25 2.20 11.0 235 122 34.7 0.85 26 2.23 11.1 238 124 63 35.9 0.90 22 2.26 11.3 243 126 36.9 0.83 26 2.31 11.5 254 137 38.2 0.88 23 2.34 11.6 259 139 36.7 0.69 22 2.27 11.3 249 133 37.1 0.69 22 2.29 11.4 252 135 67 38.4 0.74 19 2.33 11.5 257 138 39.4 0.67 23 2.38 11.8 265 145 40.7 0.71 20 2.42 11.9 271 148 39.3 0.51 18 2.34 11.6 259 142 39.6 0.52 18 2.36 11.7 263 144 71 41.0 0.55 15 2.40 11.9 268 147 33.8 0.99 29 2.36 11.7 251 124 34.9 1.00 24 2.39 11.8 256 127 32.9 0.93 27 2.32 11.5 245 121 33.2 0.94 27 2.34 11.6 249 123 59 34.3 1.00 23 2.38 11.7 254 125 34.4 0.95 28 2.41 11.9 270 132 35.6 1.00 24 2.44 12.0 276 135 33.6 0.87 26 2.36 11.7 264 129 33.9 0.88 26 2.39 11.8 268 131 63 35.1 0.94 22 2.42 11.9 273 134 36.0 0.86 27 2.48 12.1 285 144 37.3 0.91 23 2.52 12.3 291 147 35.9 0.71 22 2.44 12.0 279 141 36.2 0.72 22 2.46 12.1 283 143 67 37.5 0.76 19 2.50 12.2 288 146 38.5 0.70 23 2.56 12.5 298 154 39.8 0.74 20 2.60 12.6 304 157 38.3 0.53 18 2.51 12.3 291 150 38.7 0.54 18 2.54 12.4 295 152 71 40.1 0.57 16 2.58 12.6 301 155 33.0 1.00 28 2.50 12.4 286 129 34.1 1.00 23 2.54 12.6 291 132 32.1 0.95 27 2.45 12.2 279 126 32.4 0.96 27 2.48 12.3 283 128 59 33.5 1.00 23 2.52 12.5 288 130 33.6 0.98 28 2.55 12.6 307 137 34.8 1.00 24 2.59 12.8 314 140 32.8 0.90 26 2.51 12.4 300 134 33.1 0.90 26 2.53 12.5 304 136 35.2 0.88 27 2.63 12.9 325 150 36.4 0.94 23 2.67 13.1 331 153 35.0 0.73 22 2.58 12.7 317 147 35.4 0.74 22 2.61 12.8 321 149 37.2 0.71 23 2.68 13.2 334 158 37.5 0.71 23 2.71 13.3 339 160 38.9 0.76 20 2.76 13.5 345 163 37.4 0.54 18 2.66 13.1 331 156 37.8 0.55 18 2.69 13.2 335 158 31.8 1.00 28 2.60 12.9 321 134 32.2 1.00 28 2.62 13.0 325 136 33.3 1.00 23 2.66 13.2 332 138 31.3 0.99 27 2.58 12.8 318 133 31.6 1.00 27 2.60 12.9 322 134 32.4 1.00 28 2.65 13.1 346 142 32.8 1.00 28 2.68 13.3 350 144 33.9 1.00 23 2.72 13.4 357 147 32.0 0.92 26 2.63 13.0 342 141 32.3 0.93 26 2.66 13.2 347 143 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 34.3 36.6 39.1 32.7 33.4 0.96 0.78 0.58 1.00 1.00 22 20 16 22 23 2.57 2.65 2.73 2.64 2.70 12.7 13.0 13.4 13.1 13.4 310 328 342 329 354 139 151 161 137 146 MBh 34.2 34.9 36.5 39.0 33.4 34.1 35.7 38.1 32.6 33.3 34.8 S/T 0.94 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.97 0.87 Delta T 28 28 26 23 29 28 27 23 29 28 27 1050 KW 2.18 2.22 2.29 2.36 2.33 2.38 2.45 2.53 2.47 2.52 2.60 AMPS 10.9 11.1 11.4 11.7 11.6 11.8 12.0 12.4 12.3 12.5 12.8 HI PR 221 238 251 262 248 267 282 294 282 303 320 LO PR 116 124 135 144 123 130 142 152 127 136 148 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 1065 1350 59 35.2 0.96 23 2.22 11.1 226 119 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 75 34.0 0.90 27 2.73 13.5 365 156 34.3 0.91 27 2.76 13.6 370 158 35.5 0.97 23 2.81 13.8 377 161 34.5 0.76 23 2.74 13.5 366 156 34.2 0.75 22 2.71 13.4 361 154 67 35.7 0.81 20 2.78 13.7 373 159 30.5 1.00 26 2.73 13.7 366 142 31.6 1.00 22 2.77 13.8 373 145 29.7 1.00 26 2.68 13.4 358 139 30.0 1.00 26 2.71 13.6 362 141 59 31.1 1.00 21 2.75 13.7 370 144 31.1 1.00 27 2.79 13.9 394 151 32.2 1.00 22 2.83 14.1 402 154 30.4 0.96 26 2.74 13.7 385 148 30.7 0.97 26 2.76 13.8 390 150 63 31.8 1.00 22 2.81 14.0 398 153 32.6 0.94 27 2.87 14.3 416 165 33.8 1.00 23 2.92 14.5 424 168 32.4 0.78 22 2.82 14.0 406 161 32.8 0.79 22 2.85 14.2 412 163 67 33.9 0.84 19 2.90 14.4 420 167 34.8 0.77 23 2.97 14.7 434 176 36.0 0.81 20 3.02 14.9 442 179 34.7 0.58 18 2.91 14.4 424 172 35.0 0.59 18 2.94 14.6 429 174 71 36.3 0.63 15 2.99 14.8 438 178 28.3 1.00 24 2.82 14.3 404 147 29.3 1.00 20 2.86 14.5 412 150 27.5 1.00 24 2.77 14.0 395 144 27.8 1.00 24 2.80 14.2 400 146 59 28.8 1.00 20 2.84 14.4 408 149 28.8 1.00 25 2.88 14.5 435 156 29.9 1.00 20 2.93 14.8 444 160 28.1 0.97 24 2.83 14.3 425 153 28.4 0.98 24 2.86 14.4 431 155 63 29.4 1.00 20 2.90 14.7 439 158 30.2 0.95 25 2.97 14.9 459 171 31.3 1.00 21 3.02 15.1 469 174 30.1 0.79 21 2.92 14.7 449 167 30.4 0.80 21 2.95 14.8 455 169 67 31.4 0.85 18 3.00 15.0 464 172 115 32.2 0.77 21 3.07 15.4 479 182 33.4 0.82 19 3.12 15.6 489 186 32.1 0.59 17 3.01 15.1 468 178 32.5 0.59 17 3.04 15.3 475 180 71 33.6 0.63 14 3.09 15.5 484 184 36.3 30.2 30.8 32.3 34.4 28.0 28.6 29.9 31.9 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76 23 26 27 26 23 25 25 25 21 2.82 2.70 2.76 2.84 2.94 2.79 2.85 2.94 3.04 13.9 13.5 13.8 14.1 14.5 14.1 14.4 14.8 15.2 381 361 389 410 428 399 429 454 473 166 140 149 163 174 145 154 169 180 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 36.6 0.74 23 2.85 14.0 386 168 37.9 0.78 20 2.90 14.2 393 171 36.5 0.56 18 2.80 13.8 377 164 36.9 0.57 18 2.83 13.9 382 166 71 38.2 0.60 16 2.87 14.1 389 169 105 1ST STAGE 85 80 IDB* 65 1st Stage COOLING OPERATION EXPANDED PERFORMANCE DATA MODEL: *PG154911541A* Design Subcooling, 12 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 12°F @ the compressor suction access fitting connection. COOLING PERFORMANCE DATA *PG1549***41A* EXPANDED PERFORMANCE DATA COOLING OPERATION 44.7 0.69 22 3.09 12.8 227 107 41.3 0.67 22 3.01 12.4 221 104 46.8 0.82 24 3.14 13.0 232 109 45.5 0.79 25 3.11 12.9 230 108 42.0 0.76 26 3.04 12.5 223 105 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1300 1125 1475 63 46.8 0.70 23 3.18 13.1 247 115 43.2 0.68 24 3.10 12.8 240 111 48.2 0.74 22 3.20 13.2 250 116 42.8 0.56 19 3.08 12.7 237 110 46.3 0.58 19 3.15 13.0 245 114 47.7 0.60 18 3.18 13.1 247 115 67 50.7 0.53 19 3.28 13.5 261 125 46.8 0.51 20 3.20 13.2 253 122 52.2 0.56 18 3.30 13.6 264 127 46.9 0.39 15 3.17 13.1 251 120 50.8 0.40 14 3.25 13.4 258 124 52.3 0.42 14 3.28 13.5 261 125 54.4 0.34 13 3.38 14.0 272 134 50.2 0.33 14 3.30 13.6 264 130 56.0 0.36 13 3.41 14.1 275 135 - - - 71 59 44.4 0.81 26 3.35 13.8 258 114 41.0 0.78 26 3.27 13.4 250 111 45.7 0.85 24 3.38 13.9 260 115 40.3 0.69 23 3.24 13.3 247 109 43.7 0.72 22 3.32 13.7 255 113 45.0 0.75 21 3.35 13.8 258 114 63 45.7 0.73 24 3.42 14.1 277 121 42.2 0.70 24 3.34 13.7 269 118 47.1 0.76 22 3.45 14.2 280 123 41.8 0.58 20 3.31 13.6 266 116 45.3 0.60 19 3.39 14.0 275 120 46.6 0.63 18 3.42 14.1 277 121 67 49.5 0.55 19 3.53 14.5 293 132 45.7 0.53 20 3.45 14.1 284 128 51.0 0.58 18 3.56 14.6 296 134 45.8 0.40 15 3.42 14.0 281 127 49.6 0.41 15 3.50 14.4 290 131 51.1 0.43 14 3.53 14.5 293 132 53.1 0.35 13 3.65 15.0 305 141 49.0 0.34 14 3.56 14.6 296 137 54.7 0.37 13 3.68 15.1 308 142 - - - 71 59 43.4 0.83 26 3.56 14.8 293 119 40.0 0.80 26 3.47 14.5 284 115 44.7 0.87 24 3.59 15.0 296 120 39.4 0.71 23 3.45 14.4 281 114 42.6 0.73 22 3.53 14.7 290 117 43.9 0.77 21 3.56 14.8 293 118 44.6 0.75 24 3.64 15.2 315 126 41.2 0.72 24 3.55 14.8 306 122 46.0 0.78 22 3.67 15.3 319 127 40.8 0.59 20 3.52 14.7 303 121 44.2 0.61 19 3.61 15.0 312 125 45.5 0.64 18 3.64 15.2 315 126 48.3 0.56 19 3.76 15.6 333 138 44.6 0.54 20 3.66 15.2 323 134 49.8 0.59 18 3.79 15.8 336 139 44.7 0.41 15 3.63 15.1 320 132 48.4 0.42 15 3.73 15.5 330 136 49.9 0.45 14 3.76 15.6 333 138 51.9 0.36 13 3.88 16.2 347 147 47.9 0.35 14 3.79 15.8 337 142 53.4 0.38 13 3.92 16.3 351 148 - - - 42.3 0.86 26 3.75 15.8 334 124 39.0 0.83 26 3.66 15.4 324 121 43.6 0.90 25 3.78 15.9 337 126 38.4 0.73 23 3.62 15.2 321 120 41.6 0.76 22 3.72 15.6 330 123 42.8 0.79 21 3.75 15.8 334 124 43.6 0.77 24 3.83 16.1 359 132 40.2 0.74 24 3.74 15.7 348 128 44.9 0.81 23 3.86 16.2 363 134 39.8 0.61 20 3.70 15.6 345 127 43.1 0.63 19 3.80 16.0 356 131 44.4 0.66 18 3.83 16.1 359 132 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 1125 1300 1475 MBh S/T Delta T KW AMPS HI PR LO PR 59 46.1 0.72 21 3.11 12.9 230 108 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 75 67 47.1 0.58 19 3.96 16.6 379 145 43.5 0.56 20 3.86 16.2 368 140 48.6 0.61 19 3.99 16.7 383 146 43.6 0.42 15 3.83 16.0 364 139 47.2 0.44 15 3.92 16.5 375 143 48.7 0.46 14 3.96 16.6 379 145 59 40.2 0.89 25 3.91 16.7 376 130 37.1 0.86 26 3.81 16.3 364 127 41.4 0.94 24 3.94 16.8 379 132 36.5 0.76 23 3.78 16.1 361 125 39.5 0.79 22 3.87 16.5 372 129 40.7 0.82 21 3.91 16.7 375 130 63 41.4 0.80 23 3.99 17.1 404 139 38.2 0.77 24 3.89 16.6 392 135 42.6 0.84 22 4.03 17.2 408 140 37.8 0.63 20 3.86 16.5 388 133 41.0 0.66 19 3.96 16.9 400 137 42.2 0.69 18 3.99 17.1 404 139 67 44.8 0.61 19 4.13 17.6 427 152 41.3 0.58 20 4.02 17.1 414 147 46.1 0.63 18 4.16 17.7 431 153 41.4 0.44 15 3.99 17.0 410 145 44.9 0.45 14 4.09 17.4 422 150 46.2 0.48 14 4.13 17.6 427 151 48.1 0.39 13 4.27 18.2 445 161 44.4 0.38 14 4.16 17.7 432 157 49.5 0.41 13 4.30 18.4 450 163 - - - 71 59 37.2 0.90 24 4.04 17.6 415 135 34.4 0.87 24 3.94 17.1 402 131 38.3 0.95 23 4.08 17.7 419 136 33.8 0.76 21 3.91 17.0 398 130 36.6 0.79 21 4.01 17.4 411 134 37.7 0.83 20 4.04 17.6 415 135 63 38.3 0.81 22 4.13 18.0 447 144 35.4 0.78 22 4.03 17.5 433 139 39.5 0.85 21 4.17 18.1 451 145 35.0 0.64 18 4.00 17.4 429 138 37.9 0.66 18 4.10 17.8 442 142 39.1 0.69 17 4.13 18.0 446 144 67 41.5 0.61 18 4.27 18.5 471 157 38.3 0.59 18 4.16 18.1 457 152 42.7 0.64 17 4.31 18.7 476 158 38.4 0.44 14 4.13 17.9 453 150 41.6 0.46 13 4.24 18.4 467 155 42.8 0.48 13 4.27 18.5 471 157 115 44.5 0.39 12 4.42 19.2 492 167 41.1 0.38 13 4.30 18.7 477 162 45.9 0.41 12 4.46 19.4 497 169 - - - 71 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 50.6 0.38 13 4.09 17.2 396 154 46.7 0.36 14 3.99 16.7 384 149 52.1 0.39 13 4.12 17.3 400 156 - - - 71 105 2ND STAGE 75 70 IDB* 65 MODEL: *PG154911541A* Design Subcooling, 12 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 12°F @ the compressor suction access fitting connection. 2nd Stage COOLING PERFORMANCE DATA *PG1549***41A* 33 34 46.3 0.86 28 3.14 13.0 232 109 42.7 0.83 29 3.06 12.6 225 106 48.5 0.95 29 3.19 13.2 237 111 47.1 0.90 30 3.16 13.1 234 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1300 1125 1475 48.0 0.87 30 3.23 13.3 252 117 49.4 0.91 28 3.25 13.4 255 118 43.6 0.78 28 3.13 12.9 242 113 47.3 0.81 27 3.20 13.2 250 116 63 48.7 0.85 26 3.23 13.3 252 117 50.3 0.79 28 3.33 13.7 266 128 51.8 0.82 27 3.36 13.8 269 129 46.6 0.63 24 3.22 13.3 256 123 50.5 0.66 23 3.30 13.6 264 127 67 52.0 0.69 22 3.33 13.7 266 128 53.6 0.64 24 3.44 14.2 278 136 55.2 0.67 23 3.47 14.3 280 138 49.9 0.47 19 3.33 13.7 267 131 54.0 0.49 19 3.41 14.1 275 135 71 55.6 0.52 18 3.44 14.2 278 136 46.0 0.94 30 3.41 14.0 263 116 47.4 0.98 29 3.43 14.1 266 118 41.7 0.86 29 3.30 13.6 252 112 45.2 0.89 29 3.38 13.9 260 115 59 46.6 0.94 27 3.41 14.0 263 116 46.9 0.90 30 3.48 14.3 283 124 48.3 0.95 28 3.51 14.4 286 125 42.6 0.81 28 3.37 13.8 272 119 46.2 0.84 27 3.45 14.2 280 123 63 47.6 0.88 26 3.48 14.3 283 124 49.1 0.81 28 3.59 14.7 299 135 50.6 0.85 27 3.62 14.9 302 136 45.6 0.66 24 3.47 14.2 287 130 49.4 0.68 24 3.56 14.6 296 134 67 50.8 0.71 23 3.59 14.7 299 135 52.4 0.66 24 3.71 15.2 312 144 54.0 0.69 23 3.74 15.4 315 145 48.7 0.49 20 3.59 14.7 299 138 52.8 0.51 19 3.68 15.1 309 142 71 54.3 0.53 18 3.71 15.2 312 144 44.9 0.96 30 3.62 15.1 299 121 46.2 1.00 29 3.65 15.2 302 122 40.7 0.88 29 3.50 14.6 287 116 44.1 0.92 29 3.59 15.0 296 120 59 45.5 0.96 27 3.62 15.1 299 121 45.8 0.93 30 3.70 15.4 322 129 47.9 0.84 28 3.82 15.9 340 140 47.2 0.65 25 3.85 16.0 344 145 51.1 0.68 25 3.95 16.4 354 150 40.4 0.95 32 3.72 15.6 330 123 43.8 0.99 31 3.81 16.0 341 127 41.2 0.92 31 3.80 16.0 355 131 44.7 0.96 30 3.90 16.4 366 135 40.6 0.85 28 3.77 15.8 352 130 44.0 0.89 28 3.86 16.3 363 134 47.0 0.72 24 3.99 16.7 383 146 43.4 0.70 25 3.89 16.3 372 142 43.2 0.83 29 3.92 16.5 375 143 46.8 0.86 29 4.02 16.9 387 148 41.6 1.00 29 3.97 17.0 383 133 42.9 1.00 27 4.01 17.1 387 134 37.8 0.95 29 3.84 16.4 368 128 40.9 0.98 28 3.94 16.8 379 132 59 42.1 1.00 26 3.97 17.0 383 133 42.4 0.99 30 4.06 17.4 412 142 43.7 1.00 27 4.10 17.5 416 143 38.6 0.89 28 3.93 16.8 396 136 41.8 0.92 27 4.03 17.2 408 140 63 43.0 0.96 26 4.06 17.4 412 142 44.4 0.90 28 4.20 17.9 435 155 45.8 0.94 27 4.23 18.0 440 156 41.2 0.72 24 4.06 17.3 418 148 44.7 0.75 24 4.16 17.7 431 153 67 46.0 0.78 22 4.20 17.9 435 155 105 47.4 0.73 24 4.34 18.5 454 165 48.8 0.76 23 4.38 18.7 459 166 44.1 0.54 19 4.19 17.9 436 158 47.7 0.56 19 4.30 18.4 450 163 71 49.2 0.59 18 4.34 18.5 454 165 38.5 1.00 27 4.11 17.9 423 138 39.7 1.00 25 4.15 18.0 428 139 35.0 0.95 27 3.98 17.3 407 132 37.9 0.99 26 4.08 17.7 419 136 59 39.0 1.00 24 4.11 17.9 423 138 39.3 1.00 28 4.21 18.3 456 146 40.5 1.00 25 4.24 18.5 460 148 35.7 0.89 26 4.06 17.7 437 141 38.7 0.93 25 4.17 18.1 451 145 63 39.9 1.00 25 4.21 18.3 456 146 41.2 0.90 26 4.35 18.9 481 160 42.4 0.95 25 4.38 19.0 486 162 38.2 0.73 23 4.20 18.2 462 154 41.4 0.75 22 4.31 18.7 476 158 67 42.6 0.79 21 4.35 18.9 481 160 115 43.9 0.73 23 4.49 19.5 502 170 45.2 0.77 22 4.53 19.7 507 172 40.8 0.54 18 4.34 18.9 482 164 44.2 0.56 18 4.46 19.4 497 169 71 45.5 0.59 17 4.49 19.5 502 170 46.0 38.4 39.2 41.0 43.7 35.6 36.3 38.0 40.5 0.67 0.99 0.96 0.86 0.70 1.00 0.96 0.87 0.71 25 31 31 29 25 29 29 27 23 4.05 3.87 3.96 4.09 4.23 4.01 4.10 4.23 4.38 17.0 16.5 16.9 17.4 18.0 17.4 17.8 18.4 19.0 392 372 400 422 440 411 442 467 487 152 129 137 150 160 134 142 155 165 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 49.9 0.70 25 4.16 17.5 404 157 46.4 0.52 20 4.02 16.9 388 151 50.2 0.54 19 4.13 17.3 400 156 Shaded area reflects AHRI rating conditions 49.4 52.7 45.1 46.0 48.2 51.4 0.88 0.71 1.00 1.00 0.90 0.73 27 23 28 29 27 23 3.85 3.98 3.84 3.93 4.06 4.20 16.0 16.6 16.2 16.5 17.0 17.6 343 358 344 370 391 408 142 151 128 136 149 159 39.7 0.91 30 3.69 15.5 327 122 43.1 0.94 29 3.78 15.9 337 126 NOTE: 47.1 0.97 29 3.73 15.6 325 130 47.5 0.50 20 3.82 15.9 340 144 51.5 0.52 19 3.92 16.3 351 148 71 51.8 0.57 18 4.16 17.5 404 157 44.5 0.67 24 3.70 15.4 326 135 48.2 0.70 24 3.79 15.8 336 139 67 48.4 0.76 23 4.02 16.9 387 148 41.6 0.83 28 3.58 14.9 309 124 45.1 0.86 27 3.67 15.3 319 127 Outdoor Ambient Temperature 85 95 Entering Indoor Wet Bulb Temperature 63 67 71 59 63 46.4 49.6 53.0 44.3 45.3 0.90 0.73 0.55 1.00 0.93 26 23 18 28 26 3.70 3.82 3.95 3.81 3.90 15.4 15.9 16.4 16.0 16.4 322 340 354 341 366 129 140 150 127 135 MBh 43.5 44.3 46.4 49.5 42.5 43.3 45.3 48.4 41.4 42.2 44.2 S/T 0.87 0.84 0.76 0.61 0.90 0.87 0.79 0.64 0.93 0.89 0.81 Delta T 31 30 29 25 31 31 29 25 31 31 29 1125 KW 3.09 3.15 3.25 3.35 3.32 3.39 3.50 3.62 3.53 3.61 3.73 AMPS 12.7 13.0 13.4 13.8 13.7 14.0 14.4 14.8 14.7 15.0 15.5 HI PR 227 245 258 269 255 274 290 302 290 312 330 LO PR 107 114 124 132 113 120 131 140 117 125 136 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 1300 1475 59 47.7 0.90 27 3.16 13.1 234 110 MBh S/T Delta T KW AMPS HI PR LO PR Airflow 75 2ND STAGE 85 80 IDB* 65 COOLING OPERATION EXPANDED PERFORMANCE DATA MODEL: *PG154911541A*Design Subcooling, 12 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 12°F @ the compressor suction access fitting connection. 2nd Stage COOLING PERFORMANCE DATA *PG1549***41A* EXPANDED PERFORMANCE DATA 40.9 0.88 23 2.90 13.7 233 112 39.7 0.84 24 2.88 13.6 231 111 36.6 0.81 24 2.81 13.3 224 108 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1138 1463 1300 1138 37.7 0.72 22 2.87 13.6 241 114 40.8 0.75 22 2.94 13.9 248 118 42.1 0.79 21 2.96 14.0 251 119 37.3 0.59 18 2.85 13.5 238 113 40.8 0.55 18 2.96 13.9 254 125 44.2 0.57 18 3.03 14.2 262 129 45.5 0.60 17 3.05 14.3 265 130 40.9 0.41 14 2.93 13.8 252 124 44.3 0.43 13 3.00 14.1 260 127 43.8 0.35 12 3.05 14.3 265 133 47.4 0.37 12 3.12 14.6 274 137 48.9 0.38 12 3.15 14.7 276 138 - - 35.8 0.84 24 3.02 14.2 251 114 38.7 0.87 24 3.09 14.5 259 117 39.9 0.91 23 3.12 14.6 262 118 35.2 0.74 21 3.00 14.1 249 112 38.1 0.76 21 3.07 14.4 256 116 36.8 0.75 22 3.08 14.4 270 121 39.9 0.78 22 3.16 14.7 279 125 41.1 0.81 21 3.18 14.8 281 126 36.4 0.62 18 3.06 14.3 268 120 39.5 0.64 18 3.13 14.6 276 123 39.9 0.57 18 3.18 14.8 285 132 43.2 0.59 18 3.25 15.1 294 136 44.5 0.62 17 3.28 15.2 297 137 39.9 0.43 14 3.15 14.7 283 131 43.3 0.44 14 3.23 15.0 291 135 42.8 0.36 13 3.28 15.2 298 141 46.3 0.38 12 3.36 15.6 307 145 47.7 0.40 12 3.38 15.7 310 146 - - 34.9 0.86 24 3.20 15.1 286 118 37.8 0.89 24 3.28 15.4 294 122 39.0 0.93 23 3.31 15.6 297 123 34.3 0.76 21 3.18 15.0 283 117 37.2 0.78 21 3.25 15.3 292 120 35.9 0.77 22 3.27 15.4 307 126 38.9 0.80 22 3.35 15.7 317 129 40.1 0.84 21 3.38 15.9 320 131 35.6 0.63 18 3.24 15.3 304 124 38.5 0.65 18 3.32 15.6 314 128 38.9 0.58 18 3.37 15.8 325 137 42.2 0.60 18 3.45 16.2 335 141 43.4 0.63 17 3.48 16.3 338 143 39.0 0.44 14 3.34 15.7 321 136 42.2 0.45 14 3.43 16.0 331 140 - - 41.8 0.37 13 3.48 16.3 339 146 45.2 0.39 12 3.57 16.6 349 151 46.6 0.41 12 3.59 16.8 353 152 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 36.0 0.71 21 2.79 13.2 222 106 MBh S/T Delta T KW AMPS HI PR LO PR 1300 40.4 0.62 18 2.92 13.8 246 117 34.1 0.89 24 3.36 15.9 325 124 36.9 0.92 24 3.45 16.3 335 128 38.0 0.96 23 3.47 16.4 339 129 33.5 0.78 21 3.34 15.8 322 123 36.3 0.81 21 3.42 16.2 332 127 35.1 0.79 22 3.43 16.2 350 132 38.0 0.60 18 3.54 16.7 370 144 41.1 0.62 18 3.63 17.1 381 149 42.4 0.65 17 3.66 17.2 385 150 39.1 0.86 21 3.55 16.7 365 137 38.0 0.82 22 3.52 16.6 361 136 38.0 0.45 14 3.51 16.5 366 143 41.2 0.47 14 3.60 16.9 377 147 34.7 0.65 18 3.41 16.1 347 131 37.6 0.68 18 3.49 16.5 357 135 32.4 0.92 24 3.50 16.7 366 130 35.1 0.95 24 3.59 17.1 377 134 36.1 1.00 23 3.62 17.3 381 135 31.8 0.81 21 3.47 16.6 362 129 34.5 0.84 20 3.56 17.0 374 133 33.3 0.82 22 3.57 17.1 394 138 36.1 0.85 22 3.66 17.5 406 143 37.2 0.90 21 3.69 17.6 410 144 33.0 0.68 18 3.55 17.0 390 137 35.7 0.70 18 3.63 17.3 402 141 36.1 0.62 18 3.69 17.5 416 151 39.1 0.65 18 3.78 18.0 429 156 40.2 0.68 17 3.81 18.1 433 157 36.1 0.47 14 3.66 17.4 412 149 39.1 0.49 13 3.75 17.8 424 154 38.7 0.40 13 3.81 18.1 434 161 41.9 0.42 12 3.91 18.5 447 166 43.2 0.44 12 3.94 18.7 452 167 - - 30.0 0.93 22 3.62 17.6 404 134 32.5 0.96 22 3.71 18.0 417 139 33.4 1.00 21 3.74 18.1 421 140 29.5 0.82 19 3.59 17.4 400 133 31.9 0.85 19 3.68 17.8 413 137 30.9 0.83 21 3.70 17.9 435 143 33.4 0.86 20 3.79 18.3 449 147 34.4 0.90 20 3.82 18.5 453 149 30.5 0.68 17 3.67 17.8 431 142 33.1 0.71 17 3.76 18.2 444 146 33.4 0.63 17 3.81 18.4 460 156 36.2 0.65 17 3.91 18.8 474 161 37.3 0.68 16 3.94 19.0 479 163 33.5 0.47 13 3.78 18.3 455 155 36.3 0.49 13 3.88 18.7 469 159 35.8 0.40 12 3.94 19.0 479 166 38.8 0.42 12 4.04 19.4 494 171 40.0 0.44 11 4.07 19.6 499 173 - - 71 - KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 40.7 0.39 13 3.66 17.2 386 153 44.1 0.40 13 3.75 17.6 398 158 45.5 0.42 12 3.78 17.7 402 160 - - 67 37.3 0.51 12 3.91 18.8 474 161 1ST STAGE 75 70 39.0 0.74 20 2.86 13.5 228 110 MBh S/T Delta T KW AMPS HI PR LO PR 63 34.1 0.74 16 3.79 18.3 449 147 115 CO OLING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 40.2 41.6 45.6 39.2 40.7 44.6 38.3 39.7 43.5 37.4 38.7 42.4 35.5 36.8 40.3 32.9 S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 Delta T 20 17 13 20 17 13 20 17 13 20 17 13 20 17 13 18 1463 KW 2.88 2.94 3.03 3.09 3.16 3.25 3.28 3.35 3.45 3.44 3.52 3.63 3.59 3.66 3.78 3.71 AMPS 13.6 13.9 14.2 14.5 14.7 15.1 15.4 15.7 16.2 16.3 16.6 17.1 17.1 17.5 18.0 18.0 HI PR 231 248 262 259 279 294 294 317 335 335 361 381 377 406 429 417 LO PR 111 118 129 117 125 136 122 129 141 128 136 148 134 143 156 139 MODEL: *PG1560***41A* COOLING PERFORMANCE DATA *PG1560***41A* 35 36 EXPANDED PERFORMANCE DATA 42.3 1.00 27 2.95 13.9 238 114 41.1 0.96 28 2.92 13.8 235 113 37.9 0.93 28 2.86 13.5 228 110 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1138 1463 1300 1138 38.6 0.90 28 2.91 13.8 246 117 41.9 0.93 28 2.98 14.1 253 120 43.1 0.98 26 3.01 14.2 256 122 38.1 0.83 26 2.89 13.7 243 116 40.5 0.81 26 3.00 14.1 260 127 43.9 0.84 26 3.07 14.4 268 131 45.2 0.88 25 3.10 14.5 270 133 40.7 0.68 22 2.98 14.0 257 126 44.1 0.70 22 3.05 14.3 265 130 43.2 0.66 23 3.10 14.5 271 136 46.8 0.68 23 3.17 14.8 279 140 48.2 0.71 22 3.19 14.9 282 141 43.5 0.51 18 3.07 14.4 268 134 47.1 0.52 17 3.15 14.7 276 139 37.0 0.96 29 3.07 14.4 256 116 40.1 1.00 28 3.14 14.7 264 119 41.3 1.00 26 3.17 14.8 267 121 36.4 0.92 27 3.04 14.3 254 115 39.4 0.95 27 3.12 14.6 262 118 37.7 0.93 28 3.13 14.6 276 123 40.9 0.96 28 3.21 14.9 284 127 42.1 1.00 26 3.23 15.1 287 128 37.2 0.86 26 3.11 14.5 273 122 40.3 0.89 25 3.18 14.8 281 126 39.5 0.84 27 3.23 15.0 291 135 42.8 0.87 26 3.31 15.3 300 139 44.1 0.91 25 3.33 15.4 303 140 39.7 0.70 23 3.20 14.9 288 133 43.1 0.73 22 3.28 15.2 297 137 42.2 0.68 23 3.33 15.4 304 143 45.7 0.71 23 3.41 15.8 313 148 47.1 0.74 22 3.44 15.9 316 149 42.5 0.52 18 3.30 15.3 301 142 46.0 0.54 18 3.38 15.7 310 146 36.2 0.99 29 3.25 15.3 291 120 39.2 1.00 28 3.33 15.7 300 124 40.3 1.00 25 3.36 15.8 303 125 35.5 0.94 27 3.23 15.2 289 119 38.5 0.98 27 3.31 15.6 297 123 36.9 0.95 28 3.32 15.6 314 128 39.9 0.99 28 3.40 16.0 323 132 41.1 1.00 26 3.43 16.1 327 133 36.3 0.88 26 3.30 15.5 311 127 39.3 0.92 25 3.38 15.9 320 131 38.6 0.86 27 3.43 16.0 331 140 41.8 0.89 26 3.51 16.4 341 144 43.1 0.94 25 3.54 16.5 345 146 38.8 0.72 23 3.40 15.9 328 139 42.0 0.75 22 3.48 16.3 338 143 41.2 0.70 23 3.54 16.5 345 149 44.6 0.72 23 3.62 16.9 356 154 45.9 0.76 22 3.65 17.0 360 155 41.5 0.54 18 3.51 16.4 342 148 44.9 0.56 18 3.59 16.8 353 152 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 37.3 0.89 27 2.84 13.4 226 109 MBh S/T Delta T KW AMPS HI PR LO PR 1300 41.3 0.86 25 2.96 14.0 251 119 35.3 1.00 29 3.42 16.2 332 127 38.2 1.00 27 3.50 16.5 342 130 39.4 1.00 25 3.53 16.7 346 132 34.7 0.97 27 3.39 16.0 329 125 37.6 1.00 27 3.47 16.4 339 129 36.0 0.98 29 3.49 16.5 357 135 39.0 1.00 28 3.58 16.9 368 139 40.1 1.00 25 3.61 17.0 372 140 35.4 0.91 26 3.46 16.4 354 133 38.4 0.95 26 3.55 16.7 365 137 37.7 0.89 27 3.60 16.9 377 147 40.8 0.92 27 3.69 17.3 389 152 42.0 0.97 26 3.72 17.5 393 153 37.8 0.74 23 3.57 16.8 373 146 41.0 0.77 22 3.66 17.2 385 150 33.5 1.00 27 3.56 17.0 373 133 36.3 1.00 26 3.65 17.4 385 137 37.4 1.00 24 3.67 17.5 389 138 32.9 1.01 27 3.53 16.9 370 131 35.7 1.00 25 3.62 17.3 381 135 34.2 1.00 28 3.63 17.3 402 141 37.0 1.00 26 3.72 17.7 414 145 38.1 1.00 24 3.75 17.9 418 147 33.6 0.95 26 3.60 17.2 398 140 36.5 0.98 25 3.69 17.6 410 144 35.8 0.92 27 3.75 17.8 424 154 38.8 0.96 26 3.84 18.2 437 159 39.9 1.00 25 3.88 18.4 442 160 36.0 0.77 22 3.72 17.7 420 152 39.0 0.80 22 3.81 18.1 433 157 38.2 0.75 23 3.87 18.4 443 164 41.3 0.78 23 3.97 18.8 456 169 42.6 0.81 22 4.00 19.0 461 171 38.4 0.58 18 3.84 18.2 438 162 41.6 0.60 18 3.94 18.7 452 167 31.0 1.00 25 3.68 17.8 413 137 33.6 1.00 24 3.77 18.2 425 141 34.6 1.00 22 3.80 18.4 430 143 30.5 1.02 25 3.65 17.7 408 136 33.0 1.00 23 3.74 18.1 421 140 31.6 1.00 26 3.76 18.2 444 146 34.3 1.00 24 3.85 18.6 458 150 35.3 1.00 22 3.88 18.8 462 152 31.2 0.95 24 3.73 18.1 440 144 33.8 0.99 24 3.82 18.5 453 149 33.1 0.93 25 3.88 18.7 469 159 35.9 0.96 24 3.98 19.1 483 164 37.0 1.00 23 4.01 19.3 488 166 33.3 0.78 21 3.85 18.6 464 158 36.1 0.81 21 3.94 19.0 479 163 35.4 0.75 22 4.01 19.3 489 170 38.3 0.78 21 4.11 19.8 504 175 39.4 0.82 20 4.14 19.9 509 177 35.6 0.58 17 3.97 19.1 484 168 38.6 0.60 16 4.07 19.6 499 173 71 39.7 0.63 16 4.11 19.8 504 175 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 40.2 0.72 23 3.72 17.4 393 157 43.5 0.75 23 3.81 17.9 406 161 44.8 0.78 22 3.84 18.0 410 163 40.5 0.55 18 3.69 17.3 390 155 43.8 0.58 18 3.78 17.7 402 160 67 37.2 0.84 20 3.98 19.1 483 164 1ST STAGE 85 80 40.4 0.92 26 2.90 13.7 233 112 MBh S/T Delta T KW AMPS HI PR LO PR 63 34.8 1.00 22 3.85 18.6 458 150 115 CO OLING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 41.6 42.5 45.4 48.5 40.6 41.5 44.3 47.4 39.6 40.5 43.3 46.3 38.7 39.5 42.2 45.1 36.7 37.6 40.1 42.9 34.0 S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 1.00 Delta T 25 24 21 17 26 24 21 17 25 24 21 17 24 25 21 17 23 24 21 17 21 1463 KW 2.92 2.98 3.07 3.17 3.14 3.21 3.31 3.41 3.33 3.40 3.51 3.62 3.50 3.58 3.69 3.81 3.65 3.72 3.84 3.97 3.77 AMPS 13.8 14.1 14.4 14.8 14.7 14.9 15.3 15.8 15.7 16.0 16.4 16.9 16.5 16.9 17.3 17.9 17.4 17.7 18.2 18.8 18.2 HI PR 235 253 268 279 264 284 300 313 300 323 341 356 342 368 389 406 385 414 437 456 425 LO PR 113 120 131 140 119 127 139 148 124 132 144 154 130 139 152 161 137 145 159 169 141 MODEL: *PG1560***41A* COOLING PERFORMANCE DATA *PG1560***41A* EXPANDED PERFORMANCE DATA 56.3 0.88 22 4.45 21.6 259 108 54.7 0.84 23 4.41 21.5 257 107 50.5 0.81 24 4.32 21.0 249 104 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1584 2036 1810 1584 51.9 0.72 22 4.40 21.4 268 111 56.3 0.75 21 4.50 21.8 276 114 58.0 0.79 21 4.54 22.0 279 115 51.4 0.59 18 4.37 21.3 265 109 56.2 0.55 18 4.53 21.9 283 121 60.9 0.57 18 4.64 22.4 292 124 62.7 0.60 17 4.67 22.5 294 126 56.3 0.41 13 4.50 21.8 280 120 61.0 0.43 13 4.60 22.2 289 123 60.3 0.35 12 4.67 22.5 295 129 65.4 0.37 12 4.78 23.0 304 133 67.3 0.38 12 4.81 23.1 307 134 - - 49.3 0.84 24 4.63 22.3 279 110 53.4 0.87 24 4.73 22.7 288 113 55.0 0.91 23 4.77 22.9 291 114 48.5 0.74 21 4.59 22.1 276 109 52.5 0.76 20 4.70 22.6 285 112 50.7 0.75 22 4.72 22.7 300 117 55.0 0.78 22 4.83 23.1 310 120 56.6 0.81 21 4.87 23.3 313 122 50.2 0.62 18 4.68 22.5 297 116 54.4 0.64 18 4.79 23.0 307 119 54.9 0.57 18 4.86 23.2 317 128 59.5 0.59 18 4.98 23.7 327 131 61.3 0.62 17 5.02 23.9 330 133 55.0 0.43 14 4.82 23.1 314 126 59.6 0.44 13 4.94 23.5 324 130 58.9 0.36 12 5.01 23.9 331 136 63.9 0.38 12 5.13 24.4 341 140 65.8 0.40 12 5.17 24.5 345 141 - - 48.1 0.86 24 4.90 23.7 318 114 52.1 0.89 24 5.02 24.2 327 118 53.7 0.93 23 5.06 24.4 331 119 47.3 0.76 21 4.86 23.5 314 113 51.3 0.78 20 4.98 24.0 324 116 49.5 0.77 22 5.00 24.1 342 121 53.7 0.80 22 5.12 24.6 352 125 55.3 0.84 21 5.16 24.8 356 126 49.0 0.63 18 4.96 24.0 338 120 53.1 0.65 18 5.08 24.5 349 124 53.6 0.58 18 5.16 24.7 361 133 58.1 0.60 18 5.28 25.3 372 137 59.8 0.63 17 5.32 25.4 376 138 53.7 0.44 14 5.11 24.6 357 131 58.2 0.45 13 5.24 25.1 368 135 - - 57.5 0.37 12 5.32 25.4 376 141 62.3 0.39 12 5.45 26.0 388 146 64.2 0.41 12 5.49 26.2 392 147 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access fittings. 49.6 0.71 20 4.28 20.9 246 103 MBh S/T Delta T KW AMPS HI PR LO PR 1810 55.7 0.62 17 4.47 21.7 273 113 46.9 0.89 24 5.14 24.9 362 120 50.9 0.92 24 5.27 25.5 373 124 52.4 0.96 23 5.31 25.6 377 125 46.2 0.78 21 5.10 24.7 358 119 50.0 0.81 21 5.23 25.3 369 122 48.3 0.79 22 5.25 25.4 389 128 52.3 0.60 18 5.41 26.0 411 139 56.7 0.62 18 5.55 26.6 424 144 58.4 0.65 17 5.59 26.8 428 145 53.9 0.86 21 5.42 26.1 405 133 52.4 0.82 22 5.38 25.9 401 131 52.4 0.45 14 5.37 25.8 407 138 56.8 0.47 14 5.50 26.4 419 142 47.8 0.65 18 5.21 25.2 385 126 51.8 0.68 18 5.34 25.7 397 130 44.6 0.92 24 5.35 26.1 407 126 48.3 0.95 23 5.48 26.7 419 130 49.8 1.00 22 5.52 26.9 424 131 43.8 0.81 21 5.31 25.9 403 124 47.5 0.84 20 5.44 26.5 415 128 45.9 0.82 22 5.46 26.6 438 134 49.7 0.85 22 5.60 27.2 451 138 51.2 0.90 21 5.64 27.4 456 139 45.4 0.68 18 5.42 26.4 433 132 49.2 0.70 18 5.55 27.0 447 136 49.7 0.62 18 5.63 27.3 462 146 53.8 0.65 18 5.77 28.0 477 150 55.5 0.68 17 5.82 28.2 481 152 49.8 0.47 14 5.59 27.1 458 144 53.9 0.49 13 5.73 27.7 472 149 53.3 0.40 12 5.81 28.2 482 155 57.8 0.42 12 5.96 28.8 497 160 59.5 0.44 12 6.01 29.0 502 162 - - 41.3 0.93 22 5.53 27.3 450 130 44.7 0.96 22 5.66 28.0 463 134 46.1 1.00 21 5.71 28.2 468 135 40.6 0.82 19 5.48 27.1 445 129 44.0 0.85 19 5.62 27.8 459 133 42.5 0.83 20 5.64 27.9 484 138 46.1 0.86 20 5.78 28.5 499 143 47.5 0.90 19 5.83 28.7 504 144 42.1 0.68 17 5.60 27.7 479 137 45.6 0.71 16 5.74 28.3 494 141 46.0 0.63 17 5.82 28.6 511 151 49.9 0.65 17 5.97 29.3 527 156 51.4 0.68 16 6.02 29.5 532 157 46.1 0.47 13 5.78 28.4 506 149 50.0 0.49 12 5.92 29.1 521 154 49.4 0.40 12 6.01 29.5 533 161 53.5 0.42 11 6.16 30.2 549 166 55.1 0.44 11 6.21 30.4 555 167 - - 71 - KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 56.1 0.39 13 5.59 26.8 429 148 60.8 0.40 12 5.72 27.4 442 153 62.6 0.42 12 5.77 27.6 446 154 - - 67 51.5 0.51 12 5.97 29.3 527 156 2ND STAGE 75 70 53.8 0.74 20 4.38 21.3 254 106 MBh S/T Delta T KW AMPS HI PR LO PR 63 47.0 0.74 16 5.78 28.5 499 143 115 CO OLING O PERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 55.4 57.4 62.9 54.1 56.1 61.4 52.8 54.7 59.9 51.5 53.4 58.5 48.9 50.7 55.6 45.3 S/T 0.77 0.65 0.45 0.80 0.67 0.46 0.82 0.69 0.48 0.85 0.71 0.49 0.88 0.74 0.51 0.89 Delta T 19 17 13 20 17 13 20 17 13 20 17 13 19 17 13 18 2036 KW 4.41 4.50 4.64 4.73 4.83 4.98 5.02 5.12 5.28 5.27 5.38 5.55 5.48 5.60 5.77 5.66 AMPS 21.5 21.8 22.4 22.7 23.1 23.7 24.2 24.6 25.3 25.4 25.9 26.6 26.7 27.2 27.9 28.0 HI PR 256 276 291 288 310 327 327 352 372 373 401 424 419 451 477 463 LO PR 107 114 124 113 120 131 118 125 137 124 131 144 130 138 150 134 MODEL: *PG1560***41A* COOLING PERFORMANCE DATA *PG1560***41A* 37 38 EXPANDED PERFORMANCE DATA 58.3 1.00 26 4.52 21.9 264 110 56.6 0.96 28 4.48 21.7 262 109 52.2 0.93 28 4.38 21.3 254 106 MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR MBh S/T Delta T KW AMPS HI PR LO PR 1584 2036 1810 1584 53.3 0.90 28 4.47 21.7 273 113 57.7 0.93 27 4.57 22.1 282 116 59.4 0.98 26 4.61 22.3 284 117 52.5 0.83 25 4.43 21.5 270 112 55.8 0.81 26 4.60 22.2 288 123 60.4 0.84 26 4.71 22.7 297 127 62.2 0.88 25 4.74 22.8 300 128 56.1 0.68 22 4.57 22.1 286 122 60.7 0.70 22 4.67 22.5 294 126 59.5 0.66 23 4.74 22.8 301 131 64.5 0.68 22 4.85 23.3 310 135 66.4 0.71 21 4.89 23.4 313 137 59.9 0.51 18 4.70 22.7 298 130 64.9 0.52 17 4.82 23.1 307 134 51.0 0.96 29 4.70 22.6 285 112 55.3 1.00 28 4.81 23.0 294 116 56.9 1.00 26 4.85 23.2 297 117 50.2 0.92 27 4.66 22.4 282 111 54.3 0.95 26 4.77 22.9 291 114 52.0 0.93 28 4.79 23.0 307 119 56.4 0.96 28 4.91 23.5 316 123 58.1 1.00 26 4.94 23.6 319 124 51.3 0.86 26 4.76 22.8 304 118 55.5 0.89 25 4.87 23.3 313 122 54.5 0.84 27 4.94 23.5 324 130 59.0 0.87 26 5.06 24.0 334 134 60.8 0.91 25 5.10 24.2 337 135 54.8 0.70 22 4.90 23.4 321 129 59.3 0.73 22 5.02 23.9 330 133 58.1 0.68 23 5.09 24.2 338 139 63.0 0.71 23 5.22 24.7 348 143 64.9 0.74 22 5.26 24.9 352 144 58.5 0.52 18 5.05 24.0 334 137 63.4 0.54 18 5.17 24.5 345 141 49.8 0.99 29 4.98 24.0 324 116 54.0 1.00 27 5.10 24.5 334 120 55.6 1.00 25 5.14 24.7 337 121 49.0 0.94 27 4.94 23.9 321 115 53.0 0.98 26 5.06 24.4 331 119 50.8 0.95 28 5.08 24.5 349 124 55.0 0.99 28 5.20 25.0 359 128 56.7 1.00 26 5.24 25.2 363 129 50.0 0.88 26 5.04 24.3 345 123 54.2 0.92 25 5.16 24.8 356 126 53.2 0.86 27 5.24 25.1 368 135 57.6 0.89 26 5.37 25.6 380 139 59.4 0.94 25 5.41 25.8 383 141 53.5 0.72 22 5.20 24.9 365 134 57.9 0.75 22 5.32 25.4 376 138 56.7 0.70 23 5.40 25.8 384 144 61.5 0.72 23 5.54 26.4 396 148 63.3 0.76 22 5.58 26.6 400 150 57.1 0.54 18 5.36 25.6 380 143 61.9 0.56 18 5.49 26.2 392 147 * Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions High and low pressures are measured at the liquid and suction access fittings. 51.4 0.89 26 4.35 21.2 251 105 MBh S/T Delta T KW AMPS HI PR LO PR 1810 56.9 0.86 25 4.54 22.0 279 115 48.6 1.00 28 5.22 25.3 369 122 52.7 1.00 27 5.35 25.8 380 126 54.2 1.00 24 5.39 26.0 384 127 47.8 0.97 27 5.18 25.1 365 121 51.8 1.00 26 5.31 25.6 377 125 49.5 0.98 28 5.33 25.7 397 130 53.7 1.00 27 5.46 26.3 409 134 55.3 1.00 25 5.51 26.5 413 135 48.8 0.91 26 5.29 25.6 393 129 52.9 0.95 25 5.42 26.1 405 133 51.9 0.89 27 5.50 26.4 419 142 56.2 0.92 26 5.64 27.0 432 146 57.9 0.97 25 5.68 27.2 437 148 52.1 0.74 22 5.46 26.2 415 141 56.5 0.77 22 5.59 26.8 428 145 46.2 1.00 27 5.43 26.5 415 128 50.0 1.00 25 5.57 27.1 428 132 51.5 1.00 23 5.61 27.3 432 133 45.4 1.01 27 5.39 26.3 411 127 49.2 1.00 25 5.52 26.9 424 131 47.1 1.00 27 5.55 27.0 447 136 51.0 1.00 26 5.69 27.6 461 141 52.5 1.00 24 5.73 27.8 465 142 46.4 0.95 25 5.51 26.8 442 135 50.2 0.98 25 5.64 27.4 456 139 49.3 0.92 26 5.73 27.7 472 149 53.4 0.96 26 5.87 28.4 486 153 55.0 1.00 25 5.92 28.6 491 155 49.5 0.77 22 5.68 27.5 467 147 53.7 0.80 22 5.82 28.2 482 152 52.6 0.75 23 5.91 28.6 492 159 57.0 0.78 22 6.06 29.2 507 163 58.7 0.81 22 6.11 29.4 512 165 53.0 0.58 18 5.86 28.4 487 157 57.4 0.60 17 6.01 29.0 502 162 42.8 1.00 25 5.62 27.7 459 133 46.3 1.00 24 5.75 28.4 473 137 47.7 1.00 22 5.80 28.6 478 138 42.0 1.02 25 5.57 27.5 454 131 45.5 1.00 23 5.71 28.2 468 135 43.6 1.00 25 5.74 28.3 494 141 47.2 1.00 24 5.88 28.9 509 145 48.7 1.00 22 5.93 29.2 514 147 43.0 0.95 24 5.69 28.1 489 140 46.5 0.99 23 5.83 28.7 504 144 45.7 0.93 25 5.92 29.0 521 154 49.5 0.96 24 6.07 29.7 537 159 51.0 1.00 23 6.12 29.9 543 160 45.9 0.78 21 5.87 28.8 516 152 49.7 0.81 20 6.02 29.5 532 157 48.7 0.75 21 6.11 29.9 544 164 52.8 0.78 21 6.27 30.6 560 169 54.4 0.82 20 6.32 30.9 566 171 49.1 0.58 17 6.06 29.7 538 162 53.2 0.60 16 6.21 30.4 555 167 71 54.7 0.63 16 6.27 30.6 560 169 KW = Total system power AMPS: Unit amps (comp.+ evaporator + condenser fan motors) 55.4 0.72 23 5.68 27.2 437 151 60.0 0.75 23 5.82 27.8 451 156 61.8 0.78 22 5.87 28.0 455 158 55.7 0.55 18 5.63 27.0 433 150 60.4 0.58 18 5.77 27.6 446 154 67 51.2 0.84 20 6.07 29.7 537 159 2ND STAGE 85 80 55.6 0.92 26 4.45 21.6 259 108 MBh S/T Delta T KW AMPS HI PR LO PR 63 47.9 1.00 22 5.88 28.9 509 145 115 COOLING OPERATION Design Subcooling, 15°F + 3 @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 9°F + 3 @ the compressor suction access fitting connection. Outdoor Ambient Temperature 65 75 85 95 105 Entering Indoor Wet Bulb Temperature IDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 MBh 57.3 58.6 62.6 66.9 56.0 57.2 61.1 65.3 54.6 55.8 59.6 63.8 53.3 54.5 58.2 62.2 50.6 51.7 55.3 59.1 46.9 S/T 0.96 0.90 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.58 1.00 1.00 0.81 0.60 1.00 1.00 0.84 0.63 1.00 Delta T 25 24 21 17 25 24 21 17 25 24 21 17 24 25 21 17 23 23 21 17 21 2036 KW 4.48 4.57 4.71 4.85 4.81 4.91 5.06 5.22 5.10 5.20 5.37 5.54 5.35 5.46 5.64 5.82 5.57 5.69 5.87 6.06 5.75 AMPS 21.7 22.1 22.7 23.3 23.0 23.5 24.0 24.7 24.5 25.0 25.6 26.4 25.8 26.3 27.0 27.8 27.1 27.6 28.4 29.2 28.4 HI PR 262 282 297 310 294 316 334 348 334 359 380 396 380 409 432 451 428 461 486 507 473 LO PR 109 116 127 135 116 123 134 143 120 128 139 148 126 134 146 156 132 141 153 163 137 MODEL: *PG1560***41A* COOLING PERFORMANCE DATA *PG1560***41A* COOLING PERFORMANCE DATA PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change. 2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power. A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown. A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown. A properly operating unit should be within plus or minus 3 Amps of the typical value shown. 39 WIRING DIAGRAMS [A/G]PG15[24-60]***41** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. WARNING YL/BK YL/BK BL/PK YL LPS RD BK S R C T1 BL T2 GND PU COMP SOL YL L1 L2 CC HPS YL/BK BL PU BK POWER SUPPLY 208-230/1/60 SEE NOTE 3 BR BK CM GR BL/PK BL/PK RD PU SEE NOTE 6 BL PU 1 C BK 3 240 2 208 BK YL TR PU BL 6 2 5 1 4 PU PU 24V GR 3 PU RD RD BL YL C L G N EM PU PU WH PU YL LS OR OR PS YL RD PU YL YL YL PU RS BL OR 6 5 LO COOL BR OR WH PU 1 YL 180 150 120 90 NONE 5 MIN 10 MIN BLOWER STAGE OFF DELAY DELAY YL BL BL 1 LO HEAT OR W. R. GAS VALVE 2 4 SEE NOTE 7 2 HI HEAT YL OR YL 3 5 4 24VAC COM 3 HI COOL YL M H C BK T1 FS FS GV BK L2 LOW HIGH L1 LOW HI ODF PARK INDUCER OR PU RD BL IGN ALS BR BK BK PU PU BR 1 4 7 2 5 8 3 6 9 BR PU YL F ECON R C W1 W2 G Y1 Y2 BR BL VM BL BK RD PU RD PU BK F YL BL H C RD PU BR BR RCCF YL 0140G00533 REV A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 40 WIRING DIAGRAMS [A/G]PG15[24-60]***41** HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. WARNING L1 L2 SUPPLY VOLTAG E 208-230/1/60 CC T1 CC T2 COMPONENT LEGEND R C H INTEGRATED IGNITION CONTROL S C LO L2 F CM HI L2 LO VM L2 EM L2 HI L1 L1 L2 SEE NOTE 2 P1 TR F TH 2 ALS 3 W1 6 RS HLO 1 R LS HLI PS W2 PSW MVL 9 Y2 C HI MVC 5 P2 M MVH 7 Y1 FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RD RED WH WHITE YL YELLOW 1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY). 2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK W IRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER. C 4 INTERGRATED IGNITIO N CONTROL LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE NOTES GV COM 1 3. USE COPPER CONDUCTORS ONLY. HPS 4. FOR 208V OPERATION, REMOVE BLUE LEAD FROM INDUCER LOW TERMINAL. MOVE BLACK LEAD FROM PARK TERMINAL ONTO INDUCER LOW TERMINAL. PLACE BLUE LEAD ON PARK TERMINAL. 5. USE NEC CLASS 2 WIRE FOR THERMOSTAT FIELD WIRING. 6. COMPRESSOR 2ND STAGE SOLENOID NOT PRESENT ON ALL MODELS. 7. OPTIONAL REFRIGERANT SWITCHES 8. FOR ECONOMIZER, REMOVE PLUG FROM ECONOMIZER HARNESS. CONNECT PLUG FROM ECONOMIZER TO HARNESS. 5 LPS 3 SEE NOTE 7 SEE NOTE 8 6 1 ECON 5 2 2 ECON 5 CC SOL ECON G FACTORY WIRING AUXILLARY LIMIT SWITCH COMPRESSOR CONDENSER MOTOR CONTACTOR ECONOMIZER EVAPORATOR MOTOR FUSE FLAME SENSOR EQUIPMENT GROUND GAS VALVE INTEGRATED IGNITION CONTROL IGNITOR LIMIT SW ITCH PRESSURE SWITCH RUN CAPACITOR FOR COMPRESSOR/FAN ROLLOUT SWITCH SOLENOID (2ND STAGE COOL) TRANSFORMER VENT MOTOR PSW 8 TO MICRO INTEGRATED IGNITION CONTROL L1 ALS COMP CM CC ECON EM F FS GND GV IIC IGN LS PS RCCF RS SOL TR VM TO MICRO DIAGNOSTIC LED - RED ON OFF 3 ECON 4 LO HEAT HI HEAT LO COOL HI COOL EM C STATUS NORMAL OPERATION NO POWER OR INTERNAL CONTROL FAULT CHECK CHECK INPUT POWER CHECK FUSE(S) 1 FLASH IGNITION FAILURE GAS FLOW GAS PRESSURE GAS VALVE FLAME SENSOR 2 FLASHES PRESSURE SWITCH OPEN CHECK PRESSURE SWITCH CHECK TUBING CHECK VENT MOTOR 3 FLASHES PRESSURE SWITCH CLOSED WITHOUT INDUCER ON CHECK PRESSURE SWITCH CHECK WIRING FOR SHORTS 4 FLASHES OPEN LIMIT SWITCH CHECK MAIN LIMIT SWITCH CHECK AUXILIARY LIMIT SW. CHECK ROLLOUT LIMIT SW. 5 FLASHES 6 FLASHES FALSE FLAME DETECTED COMPR. SHORT CYCLE DELAY CHECK GAS VALVE CHECK FOR SHORTS IN FLAME SENSOR WIRING DIAGNOSTIC LED - RED 7 FLASHES STATUS LIMIT OPEN 5 TIMES IN SAME CALL FOR HEAT 8 FLASHES IDT/ODT OPEN 9 FLASHES PSW/LOC OPEN DIAGNOSTIC LED - AMBER OFF ON 1 FLASH 3 MIN COMP. SHORT CYCLE DELAY 2 FLASHES STATUS NO FLAME PRESENT NORMAL FLAME PRESENT LOW FLAME SIGNAL FALSE FLAME DETECTED CHECK CHECK MAIN LIMIT SWITCH CHECK AUXILIARY LIMIT SW. CHECK JUMPER BETW EEN 1 AND 4 ON 6-CIRCUIT CONNECTOR CHECK OPTIONAL REFRIGERANT SWITCHES CHECK REFRIGERANT SWITCHES FOR LOSS OF CHARGE OR HIGH HEAD PRESSURE CHECK GAS FLOW GAS PRESSURE GAS VALVE FLAME SENSOR CHECK GAS VALVE CHECK FOR SHORTS IN FLAME SENSOR WIRING 0140G00533 REV A Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 41