27 Microwave System The Encore oven employs left and right microwave systems. In the case of an over-current situation, the F3 fuse (20 amp) will blow, shutting off both systems immediately. This section contains information about the following components: - Capacitors - Filament transformers - High-voltage transformers - High-voltage diodes - Magnetrons - Magnetron cooling fans - Magnetron thermostats -Relay (K1 - Filament) -Relay (K2 - Anode) -Relay (K7 - Magnetron cooling fans) - Waveguides This section also contains procedures for: - Testing a capacitor (page 27) - Wiring the filament transformers (page 27) - Testing a filament or high-voltage transformer (page 27) - Wiring the high-voltage transformers (page 27) - Testing a high-voltage diode (page 29) - Testing a magnetron for an open/shorted filament (page 30) For information on accessing and removing parts, see the Appendix. Capacitors Filament Transformers For better operation and reliability, the oven utilizes separate transformers in order to preheat the magnetron filament. The filament transformers are energized for approximately five seconds prior to energizing the microwave circuit via the high-voltage transformers. When in operation, the filament transformers supply approximately 3.15 VAC at 10 amps to each magnetron filament. The filament transformers are controlled via the K1 relay. Wiring the Filament Transformers The installation of filament transformers is straightforward. Filament transformers are wired in-phase and in-line. Refer to the schematic on page 48, detailing the proper wiring. To verify correct wiring (North America), measure the voltages between terminals 1 & 2 and 1 & 3 on FT1 and FT2. The voltages must be 208 and 240 VAC respectively. See the table on page 29 for resistance values. Testing a Capacitor note: The orange wire always goes to terminal 3 on US models. To verify correct wiring (International), measure the voltage between the taps on FT1 and FT2. The voltage must be 230 VAC. See the table on page 29 for resistance values. danger: Never attempt any measurement of the capacitors while they are enabled. Lethal voltage will be present. Measure only in compliance with these procedures. oven systems - Capacitor rating is 0.91uF, 2500 VDC for all 60 Hz installations (except Japan). - Capacitor rating is 1.15uF, 2500 VDC for all 50 Hz installations. - Capacitor rating is 0.85uF, 2500 VDC for 60 Hz Japan installations. 1.Disconnect the oven from the power source. 2.Fully discharge the capacitor. 3.Isolate the capacitor from the circuit. 4.Check for an open or shorted capacitor by placing ohmmeter leads between the capacitor terminals: - Escalating ohm readings = capacitor OK - Constant infinite resistance = capacitor open - Constant very low resistance = capacitor shorted 5.If the capacitor is not open or shorted, set the meter to measure capacitance and again place the leads between the capacitor terminals. The meter reading should equal the label value, plus or minus 10%. If not, replace the capacitor.