FILE NO. SVM-06032
RAS-10NKVX-T / RAS-10NAVX-T
Unit model
RAS-10NKVX-T / RAS-10NAVX-T
Cooling capacity
Cooling capacity range
Heating capacity
Heating capacity range
Power supply
Indoor
Electric
characteristics
Outdoor
(kW)
(kW)
(kW)
(kW)
Operation mode
Running current
Power consumption
Power factor
Operation mode
Running current
Power consumption
Power factor
(A)
(W)
(%)
(A)
(W)
(%)
2.5
0.9 − 3.0
3.2
0.9 − 4.0
220− 1Ph− 50Hz
Cooling
0.15
30
91
Cooling
3.64
760
95
COP (Cooling / Heating)
Operation noise
Indoor
Heating
0.15
30
91
Heating
4.02
840
95
3.29/3.81
High
(Cooling / Heating) (dB• A)
38/39
Medium (Cooling / Heating) (dB• A)
34/35
Low
(Cooling / Heating) (dB• A)
27/29
Outdoor (Cooling / Heating)
(dB• A)
46/47
Indoor unit
Unit model
RAS-10NKVX-T
Dimension
Height
275
(mm)
Width
790
(mm)
Depth
218
(mm)
Net weight
(kg)
10
Fan motor output
(W)
20
Air flow rate (Cooling / Heating)
540/610
(m3/h)
Outdoor unit
Unit model
RAS-10NAVX-T
Dimension
Height
(mm)
530
Width
(mm)
660
Depth
(mm)
240
Net weight
(kg)
30
Compressor Motor output
(W)
750
Type
Single rotary type with DC-inverter variable speed control
Model
DA89X1F-23FZ
Fan motor output
(W)
20
Air flow rate (Cooling / Heating)
(m3/h)
1320/1320
Piping connection Type
Flare connection
Indoor unit
Liquid side
∅6.35
Gas side
∅9.52
Outdoor unit Liquid side
∅6.35
Gas side
∅9.52
Maximum length (Per unit)
10
(m)
Maximum chargeless length
(m)
10
Maximum height difference
(m)
8
Refrigerant
Name of refrigerant
R410A
Weight
(kg)
0.64
Wiring connection
Power supply
3 Wires:includes earth (Outdoor)
Interconnection
4 Wires:includes earth
Usable temperature range
Indoor
(Cooling / Heating)
(°C)
21 − 32 / Up to 27 °C
Outdoor (Cooling / Heating)
(°C)
15 − 43 / − 10 − 24
• The specification may be subject to change without nitice for purpose of improvement.