Download AIR CONDITIONER

Transcript
FILE NO. SVM-06032
6-2. Operation Data
RAS-10GKV-E2 / RAS-10GAV-E2
RAS-10NKV-A2 / RAS-10NAV-A2
RAS-10NKVX-T / RAS-10NAX-T
<Cooling>
Temperature
condition (°C)
Indoor
Outdoor
Standard
pressure
P (MPa)
27/19
35/24
1.1
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
Indoor
fan
mode
13.5
49
High
Outdoor Compressor
fan
revolution
mode
(rps)
High
54
<Heating>
Temperature
condition (°C)
Indoor
Outdoor
Standard
pressure
P (MPa)
20/15
7/6
2.4
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
Indoor
fan
mode
40
0
High
Outdoor Compressor
revolution
fan
mode
(rps)
High
70
Outdoor
fan
mode
Compressor
revolution
(rps)
RAS-13GKV-E2 / RAS-13GAV-E2
RAS-13NKV-A2 / RAS-13NAV-A2
RAS-13NKVX-T / RAS-13NAVX-T
<Cooling>
Temperature
condition ( °C)
Indoor
Outdoor
Standard
pressure
P (MPa)
27/19
35/24
0.8 to 1.0
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
Indoor
fan
mode
9 to 11
49 to 45
High
High
77
Outdoor
fan
mode
Compressor
revolution
(rps)
High
80
<Heating>
Temperature
condition ( °C)
Indoor
Outdoor
Standard
pressure
P (MPa)
20/15
7/6
2.5 to 2.7
Heat exchanger
pipe temp.
T1 (°C)
T2 (°C)
Indoor
fan
mode
42 to 44
0 to 3
High
− 32 −