F-9 F-9 TROUBLESHOOTING & REPAIR FAULT CODES 31 DESCRIPTION/ CORRECTIVE DEFINITION ACTION Main transformer primary over current Turn the machine off and back on to reset the machine. If condition persists, contact an authorized Lincoln Field Service Facility. SERVICE FACILITY CORRECTIVE ACTION Perform the Main Switch Board Test. Perform the Power Board Test. There may be a problem with the primary current sensors (CT) located on the main switch board. See the Wiring diagram The control board may be faulty. 32 Capacitor bank “A” (lower) is under voltage Make sure the reconnect switches are configured for the input voltage being applied to the machine. The machine is self clearing when condition ceases. There may be a problem with the V/F signals from the main switch board to the control board. Perform the Main Switch Board Test. Perform the Power Board Test. The control board may be faulty. NOTE: If more than one fault message is being displayed, perform all the checks for the faults before replacing the printed circuit board V350-PRO